Velodyne Acoustics SC-602 User Manual 2

SC-602 Amplifier
SubContractor™Series
USER’S
MANUAL
SC-602 Amplifier, SC-600 IW, SC-600 IF/IC Subwoofers
Caution!
IMPORTANT SAFETY INSTRUCTIONS
Caution
To reduce the risk of electric shock, do not remove cover (or back). No user-serviceable parts inside. Refer servicing to qualified service personnel.
The lightning flash with arrowhead symbol is intended to alert the user to the presence of uninsulated “dangerous voltage” within the product’s enclosure that may be of sufficient magnitude to constitute a risk o
f electric shock to persons.
The exclamation point symbol is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the subwoofer.
1. Read Instructions — All safety and operating instructions should be read before the product is operated.
2. Retain Instructions — The safety and operating instructions should be retained for future reference.
3. Heed Warnings — All warnings on the product and in the operating instructions should be adhered to.
4. Follow Instructions — All operating and use instructions should be followed.
5. Water and Moisture — The product should not be used near water — for example, near a bathtub, washbowl, kitchen sink, laundry tub, in a wet basement, near a swimming pool or the like.
6. Carts and Stands — The product should be used only with a cart or stand recommended by the manufacturer.
7. Wall or Ceiling Mounting — The product should be mounted to a wall or ceiling only as recommended by the manufacturer.
8. Ventilation — The product should be situated so that its location or position does not interfere with its proper ventilation. For example, the product should not be situated on a bed, sofa, rug, or similar surface that may block the ventilation openings; or placed in a built-in installation such as a bookcase or cabinet that may impede the flow of air through the ventilation openings.
9. Heat — The product should be situated away from heat sources such as radiators, heat registers, stoves, or other products that produce heat.
10. Power Sources — The product should be connected to a power supply only of the type described in the operating instructions or as marked on the product.
11. Grounding or Polarization — This product may be equipped with a polarized alternating-current line plug (a plug having one blade wider than the other). This plug will fit into the power outlet only one way. This is a safety feature. If you are unable to insert the plug fully into the outlet, try reversing the plug. If the plug should still fail to fit, contact your electrician to replace your obsolete outlet. Do not defeat the safety purpose of the polarized plug.
12. Power-Cord Protection — Power-supply cords should be routed so that they are not likely to be walked on or pinched by items placed upon or against them, paying particular attention to cords at plugs, convenience receptacles, and the point at which they exit from the product.
13. Cleaning — The product should be cleaned only as recommended by the manufacturer.
14. Nonuse Periods — The power cord of the product should be unplugged from the outlet when left unused for a long period of time.
15. Object and Liquid Entry — Care should be taken so that objects do not fall and liquids are not spilled onto the enclosure.
16. Damage Requiring Service — The product should be serviced by qualified service personnel when: a. The power-supply cord or plug has been damaged. b. Objects have fallen or liquid has been spilled into the product. c. The product has been exposed to rain. d. The product does not appear to operate normally or exhibits a marked change in performance. e. The product has been dropped or damaged.
17. Servicing — The user should not attempt to service the product beyond what is described in the operating instructions. All other servicing should be referred to qualified service personnel.
18. Lightning — For added protection for the product during a lightning storm or when it is left unattended and unused for long periods of time, unplug it from the wall outlet.
19. Overloading — Do not overload wall outlets, extension cords or integral convenience receptacles as this can result in a risk of fire or electric shock.
20. Attachments — Only use attachments and accessories specified by the manufacturer.
21. Voltage — Insure that the subwoofer is only connected to the rated source voltage. Do not connect the 120-volt version to 230-volts or vice-versa. This will result in damage to the subwoofer and possible injury to the user.
CAUTION: To prevent electrical shock, match wide blade of plug to wide slot, fully inserted.
.
www.velodyne.com
SC-602 Amplifier User’s Manual
Table of Contents
C
ongratulations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
Product Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
SC-602 Subwoofer Amplifier . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
SC-600 IW, SC-600 IF/IC Subwoofers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Setup Checklist . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Front Panel Controls and Displays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Rear Panel Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Rear Panel Connections - Detailed Explanation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
About Low-Pass Crossovers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
A Word About Your Receiver’s Crossover and the SC-602 Amplifier Crossover . . . . . .9
A Word About Interconnect Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
A Word About Subwoofer Placement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
Selecting the Subwoofer to be Controlled . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
Usage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
Restore Defaults . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15
Care of Your Amplifier . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15
Troubleshooting and Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17
Appendix A: RS
Velodyne Products . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20
Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21
-232 Serial Over
view and Commands . . . . . . . . . . . . . . . . . . . . . . . . .18
.
www.velodyne.com
SC-602 Amplifier User’s Manual
ii
Congratulations
C
ongratulations on your purchase of a Velodyne SubContractor Series (SC) 602 amplifier and associated subwoofer. This system represents the state-of-the-art in low frequency reproduction. Read and follow the instructions below to ensure safe and proper system operation.
Warning!
To prevent fire or shock hazard, do not expose this equipment to rain or moisture. To avoid electrical shock, do not open the speaker enclosure or the amp chassis cover. Please observe all warnings on the equipment itself. There are no user serviceable parts inside. Please refer all service questions to your authorized Velodyne dealer.
Prior to Installation
Please unpack the system carefully. Please save the carton and all packaging materials for future use. Record the serial number in the space provided on the warranty card and page 21 of this manual for future reference.
Product Features
SC-602 SUBWOOFER AMPLIFIER
• Amplifier: 400 (x2) watts dynamic/200 (x2) watts RMS high efficiency, Class D
• Twin-amplifier configuration easily drives two SC-600 Series subwoofers
• DSP-contr
• Four selectable presets for customized listening mode
• Automatic 5-band room equalizer (microphone included)
• Night-mode setting
• Mute contr
• Line-level (RCA) inputs and outputs
• Speaker-level inputs with five way binding post connections
• Signal sensing auto turn on/off (defeatable)
• Variable volume control
• Selectable phase contr
• Built-in adjustable (30-160 Hz) digital low-pass crossover with 24 dB/octave slope
• Driver Displacement Control software to prevent over excursion and amp clipping
• Blue power indicator LED
• RS-232 Serial Interface
• 12 Volt trigger
• Universal IR r
• Model-specific subsonic filter
olled
ol
epeater mini-jack
ol (0, 90, 180 or 270 degr
ees)
.
www.velodyne.com
SC-602 Amplifier User’s Manual
1
SC-600 IW, SC-600 IF/IC SUBWOOFERS
SC-600 IW (In-Wall):
- Two high excursion 6.5” active drivers, two 12.5” x 3” oval passive radiators with ribbed rubber surround
- High-excursion rubber surround
- 2” dual layer voice coil
- Frequency Response: 37 - 120 Hz (+/- 3 dB)
- 4 ohm impedance
SC-600 IF/IC (In-Floor/In-Ceiling):
- 12” (9.7” piston diameter) subwoofer
- 2.5” dual layer voice coil
- Oversized spider for linearity at high excursion
- High-excursion rubber surround
- Frequency Response: 25 - 120 Hz (+/- 3 dB)
- 4 ohm impedance
Setup Checklist
Be sure to do the following to ensure the best performance from your subwoofer:
If possible, optimize the placement of the subwoofer(s) in the listening area.
See page 10 of the User’s Manual.
Install and wire the subwoofer per the instructions on pages 3 - 8.Set the amp to the proper subwoofer model per the instructions on page 11.Select the proper volume level. See page 4.Select the prEqualize the subwoofer using the microphone and Auto-EQ feature. See page 12. Adjust the phase contrSelect the cor
Your new Velodyne amplifier provides for a number of installation options. Read all the installation information below in order to determine which installation option is best for your system. Remember to per
oper low-pass cr
ol on the remote to the correct setting. See page 12.
rect preset for the source material. See page 13 - 14.
m all installation pr
for
ossover frequency. See pages 9 - 10.
ocedur
es with system power tur
ned of
f.
.
www.velodyne.com
SC-602 Amplifier User’s Manual
2
Installation
FRONT PANEL CONTROLS AND DISPLAYS
FRONT PANEL CONTROLS AND DISPLAYS
602
Figure 1: Front Panel Connections of the SC-602 amplifier.
Following are brief descriptions of the controls described in Figure 1. More detail on these controls can be found in the next section.
(1) Power Switch
This button forces your SC-602 amplifier into standby mode. The power LED turns amber, the numeric LED shuts off, and the amplifier puts out no power. The unit will remain in this mode until the POWER button is pr use the main power switch on the back panel.
(2) Power LED
This LED illuminates when the power is on. Blue is normal operation. It tur the unit is in standby mode or the remote has been used to deactivate the unit, and dims when the unit is in night mode.
Mic Input
(3)
Connect the supplied microphone for the Auto-EQ feature to this mini-jack input.
Remote Eye
(4)
This is the eye that receives infrared commands from the supplied remote control.
(5) Crossover
Use the UP and DOWN buttons to select the low-pass crossover frequency. All information above this frequency is reproduced by your speakers. Information below this frequency is handled by your subwoofer display reverts to showing the subwoofer’s volume level. The slope is fixed at 24 dB/octave.
o deactivate the cr
T indicate the crossover is deactivated and the woofer plays all frequencies presented to it. Please see page 9 for a more detailed discussion on crossovers.
ossover, press the up crossover button until two dashes on the display
. The fr
essed again. To fully deactivate (i.e. power down) the unit,
ns amber when
equency is briefly indicated on the LED display
, then the
.
www.velodyne.com
SC-602 Amplifier User’s Manual
3
-
-
-
ALWAYS ON STANDBY MODE
115V
FUSE LOCATION
9
10 11
12
16
17 18
13
14 15
19
20
22
21
(
6) LED Numeric Indicator
This LED supplies information on volume, crossover, woofer type, and other information. The l
ight button on the remote deactivates this display. Upon startup, the display shows the
model of subwoofer the SC-602 amp is set to, then reverts to the volume indicator.
(7) Volume Control
These buttons allow you to balance the output from the subwoofer with the output of the main speakers in your system. The volume should be set to achieve similar volume level of both the main speakers and subwoofer. The default volume is 30.
Note: Volume can also be controlled by using the supplied remote.
WARNING: Some manufacturers preset their receivers with the Sub-Out (A.K.A. LFE) channel signal at a minimum level. It is very important to verify that your receiver Sub-Out channel is set to the same output level as your front right and left channels. Refer to your receiver manual for the individual channel level adjustment procedure. If your receiver Sub-Out channel is set too low, the subwoofer may appear to have a weak output, it may sound noisy or distorted, and the Auto On/Off feature may not operate properly.
(8) Optional Rack Mount Ears (Included)
These ears can be attached to the SC-602 amp to allow standard 19” rack mounting.
REAR PANEL CONNECTIONS
Following are brief descriptions described in Figure 2. More detail on these controls can be found in the next section.
Figure 2: Rear Panel Connections of the SC-602 amplifier.
(9) Thru Jacks
These RCA connectors are for passing along the same signal that goes into your subwoofer to a second “daisy-chained” system. The signal fr the input signal.
om these RCA connectors is the same as
(10) Line Input / LFE Input
Connect these jacks to the LINE OUT pr of your receiver/processor. If using the LFE output from your receiver or processor, plug the single cable into the jack labeled LFE input or, for more signal, use a “Y” connector (optional) and feed the signal into both “R” and “L” inputs. Examples of these types of connections can be found in Figures 2A and 2B.
.
www.velodyne.com
eamp output, LFE output, or subwoofer output jacks
SC-602 Amplifier User’s Manual
4
O
-
-
-
A
LWAYS ON STANDBY MODE
115V
FUSE LOCATION
9
10 11
12
16
17 18
13
1
4
15
19
20
22
21
-
-
-
ALWAYS ON STANDBY MODE
115V
F
USE LOCATION
9
10 11
12
16
17 18
13
14
15
19
20
22
21
ption 1
ine-Level
L Subwoofer Signal from Source (LFE)
Note: A “Y” connector can
e used as an option.
b
Figure 2A: Mono (LFE) Line-Level Connection.
C-600
S
ubwoofer
S
C-600
S
ubwoofer
S
Option 2
Stereo Line-Level Output to Another System, e.g. a second SC-600 or SC-602 amplifier
Stereo Line-Level Input from Source
e 2B: Stereo Line-Level Connection.
Figur
SC-600
Subw
oof
N10533
SC-600
Subw
oof
er
er
.
www.velodyne.com
SC-602 Amplifier User’s Manual
5
Loading...
+ 17 hidden pages