USER MANUAL 3
GEBRUIKERSHANDLEIDING 6
NOTICE D‟EMPLOI10
MANUAL DEL USUARIO 13
BEDIENUNGSANLEITUNG 17
VDP1500SSM2
2
terminator
eindweerstand
résistance de
terminaison
terminación
Terminierung
How to turn the controller line from 3-pins into 5-pins (plug and socket).
Controller line van 3-pin naar 5-pin aanpassen (stekker en contact).
Modifier la ligne du contrôleur de 3 broches en 5 broches (fiche et contact).
Modificar la línea del controlador de 3 polos y 5 polos (conector y contacto).
Die Controller-Linie von 3-Pin nach 5-Pin anzupassen (Stecker und Kontakt).
Keep the device away from children and unauthorised users.
Indoor use only.
Protect the smoke machine and remote control from rain, moisture, splashing and
dripping liquids, extreme heat and dust. Never put objects filled with liquid on top.
Protect the smoke machine and remote control from shocks and abuse. Avoid brute force
when operating.
Risk of electroshock when opening!
Do not disassemble or open the cover(s).
Keep this device away from dust and extreme temperatures. Make sure the ventilation
openings are clear at all times. For sufficient air circulation, leave at least 1” (±2.5 cm)
in front of the openings.
USER MANUAL
1. Introduction
To all residents of the European Union
Important environmental information about this product
Thank you for choosing HQPower™! Please read the manual thoroughly before bringing this device into
service. If the device was damaged in transit, don't install or use it and contact your dealer.
2. Safety Instructions
3. General Guidelines
Refer to the Velleman® Service and Quality Warranty on the final pages of this manual.
This symbol on the device or the package indicates that disposal of the device after its lifecycle
could harm the environment. Do not dispose of the unit (or batteries) as unsorted municipal
waste; it should be taken to a specialized company for recycling. This device should be returned
to your distributor or to a local recycling service. Respect the local environmental rules.
If in doubt, contact your local waste disposal authorities.
Damage caused by disregard of certain guidelines in this manual is not covered by the warranty and
the dealer will not accept responsibility for any ensuing defects or problems.
All modifications to the smoke machine or remote control are forbidden for safety reasons. Note that
damage caused by user modifications to the smoke machine or remote control is not covered by the
warranty.
Only use the smoke machine for its intended purpose. Using the smoke machine in an unauthorised way
will void the warranty.
Familiarise yourself with the functions of the smoke machine before actually using it.
Never aim the smoke output directly at humans or animals. Keep the spray nozzle at a minimum distance
of 5 m from humans, animals and objects.
Do not touch the smoke machine when in use as the housing may reach a temperature of up to 80°C. Let
the smoke machine cool down sufficiently after switching off before handling.
Never cover the smoke machine and do not install it on a carpet or wooden floor.
A duty cycle of 30 % is advisable.
4. Features
new design allows for horizontal or upwards use
easy to attach to a wall
very fast heating time for continuous output
DMX controlled
remote controller included
optional (not incl.): high-density smoke liquid (VDLSLH5), pro high-density smoke liquid (VDLSLHT5),
Install the smoke machine in a well-ventilated place, at a minimum
distance of 3 m from any inflammable and explosive substance, and at a
minimum height of 0.5 m.
Switch off the smoke machine and disconnect from the mains before
proceeding.
Never run the smoke machine without liquid.
5. Overview
Refer to the illustrations on page 2 of this manual.
6. Installation
Ideally, the smoke machine should be installed on a sturdy and level surface. If the smoke machine
must be hung up, please consider following guidelines:
o Have the smoke machine installed by a qualified person, respecting EN 60598-2-17 and all other
applicable norms.
o The carrying construction must be able to support 10 times the weight of the smoke machine for 1
hour without deforming.
o The installation must always be secured with a secondary attachment e.g. a safety cable.
o Never stand directly below the smoke machine when it is being mounted, removed or serviced.
Have a qualified technician check the smoke machine once a year and once before you bring it into
service.
o Install the smoke machine in a location with few passers-by that is inaccessible to unauthorised
persons.
o Overhead mounting requires extensive experience: calculating workload limits, determining the
installation material to be used… Have the material and the smoke machine itself checked regularly.
Do not attempt to install the smoke machine yourself if you lack these qualifications as improper
installation may result in injuries.
o The installation has to be approved by an expert before the smoke machine is taken into service.
7. Use
Unscrew the filler cap to open the tank. Fill half of the tank with a quality smoke liquid. We
recommend using the HQPower™ High-Density or the Pro High-Density smoke liquid. Make sure not to
spill any liquid so as not to damage the internal circuit of the smoke machine. Close the tank with the
filler cap.
Connect the remote control to the smoke machine. Insert the 5-pin XLR connector of the remote
control into the 5-pin remote control connection [4].
Insert the power cord into the mains.
Choose whether to run the smoke machine as a stand-alone device or in a DMX512 configuration.
a) Stand-Alone Use
Switch on the smoke machine [1]. The green LED [10] will light as soon as the smoke machine is
ready-for-use.
How to burst out smoke:
o Simple smoke burst: Hold the green button [10] pressed to emit a smoke burst.
o Continuous smoke burst: Press the red button [9] for a continuous smoke burst.
o Timer: Press the yellow timer button [8] and adjust the interval between two bursts with the
interval/output time adjustment knob [6].
Adjust the smoke output with the smoke output adjustment button [7].
Switch off the smoke machine and disconnect from the mains after use.
b) DMX-Control
DMX connection:
Multiple VDP1500SSM2 smoke machines can be linked through serial linking. Connect the 3-pin XLR
Switch off the smoke machine and disconnect from the mains before
performing any maintenance or cleaning operation.
Problem
Possible solution
The smoke machine does not
work when switched on [1].
Check if the power cord is correctly inserted into the mains.
Check the mains power circuit.
There is no smoke output
when the green [10] or red
[9] switch is pressed.
Check if the remote control connector is correctly inserted into the
connection [4].
The smoke machine hasn‟t reached operating temperature yet. Wait
until the green LED [10] lights.
Check the liquid level inside the tank and refill if necessary.
Residue may have clogged up the output nozzle. Clean the nozzle by
gently poking the inside with a needle.
The nozzle keeps emitting
smoke even after releasing
the green [10] or red [9]
switch.
Occasionally, a little smoke escapes from the nozzle after a smoke
burst. This is absolutely normal.
Immediately switch off the smoke machine and disconnect from the
mains if the smoke burst does not stop after releasing the green [10]
or red [9] switch.
output [5] of the smoke machine to the 3-pin XLR input [5] of the next smoke machine in the series
using a high-quality, two-core, screened cable (not included).
DMX chain with terminator:
A DMX terminator is recommended for installations where the DMX cable has to run a long distance or
used in an electrically noisy environment (e.g. discos). The terminator prevents corruption of the
digital control signal by electrical noise. The DMX terminator is simply an XLR plug with a 120 Ω
resistor between pins 2 and 3, which is then plugged into the XLR output socket of the last device in
the chain (see illustration on page 2).
DMX start address selection:
All DMX-controlled devices need a digital start address so that the correct device responds to the
signals. This digital start address is the channel number from which the device starts to “listen” to the
DMX controller.
You can use the same starting address for a whole group of smoke machines or enter an individual one
for every smoke machine.
When all smoke machines have the same address, all the units will “listen” to the control signal on one
particular channel. In other words: changing the settings of one channel will affect all smoke machines
simultaneously. If you set different addresses, each smoke machine will “listen” to a separate channel
number. Changing the settings of one channel will only affect the smoke machine in question.
In the case of the 1-channel VDP1500SSM2, you will have to set the start address of the first smoke
machine to 1, the second smoke machine to 2 (1 + 1), the third to 3 (2 + 1), and so on.
Use the smoke machine as described in 7. a) Stand-Alone Use. Note that the series of smoke
machines can be controlled using only one remote control connected to any of the units in the series.
Switch off the smoke machine and disconnect from the mains after use.
8. Maintenance
The smoke machine must be cleaned after every 40 hours of use. We recommend using the
HQPower™ VDLCL liquid to thoroughly clean the tank, feeding tube and spray nozzle. Remove or use
up all the smoke liquid inside the tank and fill half of the tank with the cleaning liquid. Reconnect the
smoke machine to the mains and switch on [1]. Let the smoke machine run in automatic mode (red
button [9]) until all cleaning liquid is used. Switch off [1] the smoke machine and let it cool down.
Clean the housing of your smoke machine and remote control on a regular basis. Use a moist, lint-free
cloth. Avoid using alcohol or solvents.
Store the smoke machine and remote control in a cool, dry and clean location.
There are no user-serviceable parts inside. Refer to an authorized dealer for service and/or spare
parts.
9. Troubleshooting
Remember to contact your HQPower™ service agent in case problems persist.
Houd buiten het bereik van kinderen en onbevoegden.
Enkel voor gebruik binnenshuis.
Bescherm de rookmachine en afstandsbediening tegen regen, vochtigheid en opspattende
vloeistoffen, extreme temperaturen en stof. Plaats geen objecten gevuld met vloeistof op
het toestel.
Bescherm de rookmachine en afstandsbediening tegen schokken en vermijd brute kracht
tijdens de bediening.
Elektrocutiegevaar bij het openen van de behuizing!
U mag de behuizing niet openen.
10. Technical Specifications
Use this device with original accessories only. Velleman nv cannot be held responsible in the
event of damage or injury resulted from (incorrect) use of this device. For more info
concerning this product and the latest version of this manual, please visit our website
www.hqpower.eu. The information in this manual is subject to change without prior notice.
No part of this manual or may be copied, reproduced, translated or reduced to any electronic medium or
otherwise without the prior written consent of the copyright holder.
GEBRUIKERSHANDLEIDING
1. Inleiding
Aan alle ingezetenen van de Europese Unie
Belangrijke milieu-informatie betreffende dit product
Hebt u vragen, contacteer dan de plaatselijke autoriteiten betreffende de verwijdering.
Dank u voor uw aankoop! Lees deze handleiding grondig voor u het toestel in gebruik neemt. Werd het
toestel beschadigd tijdens het transport, installeer het dan niet en raadpleeg uw dealer.
2. Veiligheidsinstructies
Dit symbool op het toestel of de verpakking geeft aan dat, als het na zijn levenscyclus wordt
weggeworpen, dit toestel schade kan toebrengen aan het milieu. Gooi dit toestel (en eventuele
batterijen) niet bij het gewone huishoudelijke afval; het moet bij een gespecialiseerd bedrijf
terechtkomen voor recyclage. U moet dit toestel naar uw verdeler of naar een lokaal
recyclagepunt brengen. Respecteer de plaatselijke milieuwetgeving.
3. Algemene richtlijnen
Raadpleeg de Velleman® service- en kwaliteitsgarantie achteraan deze handleiding.
Bescherm tegen stof en extreme temperaturen. Zorg dat de verluchtingsopeningen niet
verstopt geraken. Voorzie een ruimte van minstens 2,5 cm tussen het toestel en elk
ander object.
1
aan-uitschakelaar
6 instelknop interval
2
DIP-schakelaars
7 instelknop debiet
3
voedingskabel
8 timerfunctie + led
4
5-pin aansluiting voor afstandsbediening
9 schakelaar + led automatische rookuitstoot
5
3-pin XLR-aansluiting
10
schakelaar + led handmatige rookuitstoot
Installeer de rookmachine op een goed geventileerde plaats, op een
minimumafstand van 3 m van alle brandbaar en explosief materiaal, en
op een minimumhoogte van 0,5 m.
De garantie geldt niet voor schade door het negeren van bepaalde richtlijnen in deze handleiding en
uw dealer zal de verantwoordelijkheid afwijzen voor defecten of problemen die hier rechtstreeks
verband mee houden.
Om veiligheidsredenen mag de gebruiker geen wijzigingen aanbrengen aan de rookmachine of
afstandsbediening. Schade door wijzigingen die de gebruiker heeft aangebracht aan de rookmachine of
afstandsbediening vallen niet onder de garantie.
Gebruik de rookmachine enkel waarvoor ze gemaakt is. Bij onoordeelkundig gebruik vervalt de
garantie.
Leer eerst de functies van de rookmachine kennen voor u ze gaat gebruiken.
Richt de rookpluim nooit naar mensen of dieren. Houd de straalbuis op een minimumafstand van 5 m van
mensen, dieren en voorwerpen.
Raak een ingeschakelde rookmachine niet aan; de temperatuur van de behuizing kan oplopen tot 80°C.
Laat de rookmachine na gebruik voldoende afkoelen alvorens ze met de blote hand aan te raken.
U mag een ingeschakelde rookmachine nooit bedekken. Installeer de rookmachine niet op een tapijt of
houten vloer.
Een werkcyclus van 30 % is aanbevolen.
4. Eigenschappen
nieuw design: geschikt voor gebruik liggend als rechtstaand
gemakkelijk te bevestigen aan de muur
korte opwarmtijd
DMX-gestuurd
geleverd met afstandsbediening
in optie (niet meegelev.): high-density rookvloeistof (VDLSLH5), high-density rookvloeistof 'pro'
(VDLSLHT5), reinigingsvloeistof (VDLCL)
5. Omschrijving
Raadpleeg de afbeeldingen op pagina 2 van deze handleiding.
6. Installatie
Plaats de rookmachine bij voorkeur op een stabiel en horizontaal oppervlak. Volg volgende richtlijnen
zorgvuldig na indien de rookmachine wenst op te hangen:
o Laat een geschoolde technicus dit toestel installeren conform EN 60598-2-17 en andere
toepasselijke normen.
o De constructie waaraan het toestel wordt bevestigd, moet gedurende 1 uur 10 keer het gewicht van
dit toestel kunnen dragen zonder te vervormen.
o Maak het toestel ook vast met een veiligheidskabel.
o Sta nooit recht onder het toestel wanneer u het monteert, verwijdert of schoonveegt. Laat het
toestel controleren door een geschoolde technicus voor u het in gebruik neemt en laat het 1 x per
jaar volledig nakijken.
o Installeer dit toestel op een plaats waar niemand langs moet lopen, kan neerzitten of het toestel
kan aanraken.
o Een degelijke praktijkervaring is vereist voor de plaatsing van dit toestel. U moet de
maximumbelasting van de draagconstructie kunnen berekenen, weten welk constructiemateriaal u
kunt gebruiken en u moet het gebruikte materiaal en het toestel af en toe laten nakijken. Monteer
het toestel niet zelf indien u er geen ervaring mee heeft. Een slechte montage kan leiden tot
verwondingen.
o Een geschoolde elektricien moet het toestel aansluiten.