Veilux SVEX-171 User Manual

Ex-mark
:
ExdⅡBT6 / DIP A21 TA, T6
License
CNEx06.1580
:
:
XK06-123-00251
Veilux SVEX-171 Explosion Proof
Monitor
SVEX-171 Monitor
Ver: 1.1
2
www.veilux.net
Safety Notes
1. Installation
Please install under required environment
Ensure stable and reliable mounting in case camera be damaged
Ensure supply power same as nameplate marked before equipment being powered
Do not open the flameproof joint and enclosure under humid atmosphere. Because of
Connect the cables correctly under the demand of manual book, and press tighten nut.
2. Maintenance
Please shut off before maintenance and repair
Pay attention to the flameproof joint while disassembly and assembly
3. Environmental protection
excellent tightness of the equipment, framing member may rusts after humid air enters
flameproof, humidity could not go outside
The products contain spare parts which may pollute the environment, for example: PCB,
electric component, plastic goods, lubricating grease and so on. Please collect and control
the pollution sources when the equipment is maintained and scrapped. Don’t discard it but
pass it to environmental department, in case it will influence the environment.
SVEX-171 Monitor
Ver: 1.1
3
www.veilux.net
1. Brief ............................................................................................ 4
2. Technical data .......................................................................... 4
2.1 Type Code ......................................................................... 4
2.2 Certificate .......................................................................... 5
2.3 Electrical ............................................................................ 5
2.4 Technical data.................................................................... 5
2.5 Mechanical ........................................................................ 6
2.6 Environmental ................................................................... 6
2.7 Dimension.......................................................................... 6
2.8 Installation Size ................................................................. 7
3. Installation.................................................................................. 7
3.1 Desktop installation ........................................................... 7
3.2 Wall Mount Installation..................................................... 8
3.3 Hoisting ............................................................................. 8
3.4 Cable Treatment ................................................................ 9
3.4.1 Use Ex-proof Flexibility Tube ............................ 9
3.4.2 Connect power cable........................................ 10
3.4.3 Connect signal cable ........................................ 11
4. Application ............................................................................... 12
4.1 System Connection .......................................................... 12
4.2 Power on .......................................................................... 12
5. Flameproof structure .............................................................. 13
6. Trouble shooting ..................................................................... 14
7. Shipment and storage............................................................ 14
8. Guarantee ................................................................................ 14
9. Statement ................................................................................ 14
SVEX-171 Monitor
Ver: 1.1
4
www.veilux.net
1. Brief
YHJ-171Ex-proof displayer is new generation ex-proof monitor equipment. It changes the condition of terminal display equipment only be set in the control room. It can offer the
customers the clear monitor picture in the dangerous ex-proof area. At the same time, it can enhance the flexibility of the system setting. SVEX-151 adapts advanced manufacturing process. With the help of mature quality, the quality and function of products are leading position. SVEX-151 Ex-proof monitor has the characters of small in size, light in weight, convenient in shipment. The various connections will make flexible application.
Strictly according to European Directive EC/94/9 and EN50014, Standards of GB3836.1­2000 GB3836.12000 Electrical apparatus for explosive atmosphere: General requirements, GB3836.2-2000 Electrical apparatus for explosive atmosphere: Flameproof ‘d’ and GB12476.1-2000 Electrical apparatus for explosive dust: Using enclosure and limiting surface temperature for protecting electrical apparatus Chapter 1: Technical requirements. The housing is made of stainless steel, Ip65.
High quality LCD panel is installed inner monitor, it can offer 1280 x1024 resolution ratio and display picture. Quick response displays walking Graphic well. TCO'03 keeps the highest safety and human engineering standards.
2. Technical data
2.1 Type Code
S V EX 171
( E x
)
Ex-mark Design No Monitor
Veilux
SVEX-171 Monitor
Ver: 1.1
5
www.veilux.net
2.2 Certificate
2.3 Electrical
2.4 Technical data
Ex-marking ExdBT6 / DIP A21 TA, T6 Ex Certificate CNEx06.1580 ATEX Certificate XK06-123-00251
Input Voltage 100~240VAC, 50/60Hz
Consumed power 30 Wtypical value
Electric connection
Power 3-core power cable Signal input Support only one when two methods appear
RGB imitate input 15 needles D-SUB Video input BNC pin
Panel type area
TFT LCD Display
17 inch diagonal
Pixel density 0.264 x 0.264 mm
Best resolution ratio Available area
1280 x 1024 @ 60Hz
337.9 x 270.3 mm Color 16,770,000 Tilt refresh rate 56Hz ~ 76Hz Pan refresh rate 30KHz ~ 83KHz Bandwidth 140MHz Input impedance
Video 75
sync signal 2200
Input signal level 700mVp-p Synchronization input signal Separate synchronization signal / Compose synchronization
signal / Green signal Synchronization signal pole Plus-minus pole Contrast corner peak value 180°
SVEX-171 Monitor
Ver: 1.1
6
www.veilux.net
2.5 Mechanical
2.6 Environmental
2.7 Dimension
Protection IP65 Material 304 Weight 25Kg Dimension 395(H) x 424(W) x 200(D) mm Len size 384 x 316 mm Glass thickness 12mm Inner cubage 3L Outlet hole quantity 2 Outlet hole screw thread size G-3/4”
Air Pressure 86106KPa Environment Temperature
Working 0~+40
Storage -20~+60
Relative Humidity
U
95%RH(+25)
1. SVEX-171 Ex-proof displayer dimension
SVEX-171ExEX Monitor
Ver: 1.1
www.veilux.net
2.8 Installation Size
2. Displayer fixed hole
3. Installation
3.1 Desktop installation
SVEX-171Ex-proof displayer can be used corresponding to YHIC ex-proof IPC. It also can
be used as a monitor to watch video signal. It usually is set on the table directly. Lamp stand
is also fixed with bolt.
3. Displayer can be set on the table directly. 4. Fix the lamp stand with bolt.
Adjust screen angel according watching angel. Screen can be adjusted Tilt ±18°
18°
18°
7
SVEX-171ExEX Monitor
Ver: 1.1
8
www.veilux.net
5. Loosen two bolts to adjust 6. Adjust angel on tilt direction
3.2 Wall Mount Installation
In some occasions, we can use wall mount installation to save room. If we adjust the
combination of lamp stand, we can achieve the aim. Screen can be adjusted Tilt ±18° when
wall mount installation.
7. Wall mount installation 8. Lamp stand is fixed to the wall with bolt
3.3 Hoisting
We can fix monitor bottom to the ceiling. With the help of software, overturn the
picture with main engine. Then hoisting is achieved.
SVEX-171ExEX Monitor
Ver: 1.1
9
www.veilux.net
3.4 Cable Treatment
(or a coaxial cable). Ensure the corresponding ex-proof flexibility tube reach the demand of ex-proof before leave factory.
3.4.1 Use Ex-proof Flexibility Tube
a. As Picture 11, turn on the tighten nut behind the back of the displayer. Turn on the screw thread connector corresponding to ex-proof flexibility tube.
9. Lamp stand is fixed to the ceiling with bolt 10. Adjust screen angel when
hoisting
SVEX-171 Ex-proof displayer is attached a power cable and a VGA signal cable
11.
b. As picture 12, take down press tighten nut, keep standard configuration gasket and rubber ring (or use the spare parts). Sheathe screw thread connector and ex-proof flexibility tube.
SVEX-171ExEX Monitor
Ver: 1.1
10
www.veilux.net
c. As Picture 13, firstly turn tight the screw connection head and then tight the Ex-proof Flexibility Tube.
12.
d. As picture 14, the design sketch after installation.
13.
14. The design sketch after install ex-proof flexibility
3.4.2 Connect power cable
Power cable is a 3-core cable; it must be attached ex-proof junction box when application. Connect cable in the junction box. The color of the cable is defined as following:
SVEX-171ExEX Monitor
Ver: 1.1
11
www.veilux.net
Name
Power cable
Function
Live line
Null line
Earth line
Color
Brown
Blue
Color
Foot
No
Function definition
Corresponding cable
color
1
Red video input
Pinkscreening
thick
2
Green video input/SOG
Darkscreening
thick
3
Blue video input
Cambridge blue
screeningthick
4
SENSElanding
Black
5
Signal line testlanding
White
6
Red video live line
Metal wire
screening
7
Green video live line
Metal wire
screening
8
Blue video live line
Metal wire
screening
9
+5V
Brown
10
Logic live line
Red
11
Landing
Yellow
12
In tandem data lineSDA
Orange
13
Pan synchronization /Tilt and pan synchronization
Light green
14
VCLK for DDC
Blue
15
SCL
Purple
3.4.3 Connect signal cable
video input, the product lead in a coaxial line. It needs to avoid BNC pin. When use VGA input, SVEX-171lead in a VGA cable.
is easy to be influenced. It is not suit to transfer foe a long distance. A VGA pin will be made with the method of welding when application. Please pay attention to the operational tools.
Professional soldering station is recommended to use. Power off soldering iron when welding.
1. Power cable definition
SVEX-171has two input ways, and only one is supported when leave factory. When use
Standard VGA cable is 15-core screening cable. Because of output RGB signal is weak, it
15. 15 contact pin D connector
2.VGAcable definition
SVEX-171ExEX Monitor
Ver: 1.1
seal ring inner hole diameter
mm
Cable minimum diameter
mm
Φ6
Φ5.5
Φ8
Φ7.5
Notice
The above color definition is limited to the attached cable when leave factory. If user set
himself, check color definition again to avoid breakdown.
Cable external diameter should match to seal rubber inner diameter. Ensure, seal rubber
ring and cable, seal rubber ring and lead in equipment interval reaches the demand of ex-proof after tighten nut. The demand of cable external diameter as following:
3. The demand of cable external diameter size
4. Application
4.1 System Connection
VGA
SVEX-2028E
SVEX-171(Ex)
4.2 Power on
Press the switch lightly and the displayer enters the working condition. The switch can be auto locked press it if half upspring condition is power on, If whole upspring condition is power off.
12
SVEX-171ExEX Monitor
Ver: 1.1
13
17. Power On/Off switch position
5. Flameproof structure
Completely consider the explosive air getting into ex-proof structure, which may lead to
explosion because of some reason and to confirm and ensure camera explosion proof performance based on its structure gap, length and max temperature it will get to.
Enclosure shall burden water pressure testing for 1.0Mpa for 10~12 seconds without
leakage as pass, which is ordered in GB3836.2-2000.
Camera surface temperature max shall not over 80 while it is working.
The lead to equipment is with the method of turn tight the screw.
Window glass adopts steel glass to burden Impact and Heat change testing.
Window glass adopts steel glass to burden Impact and Heat change testing.
17” LCD screen Front Panel
Tempered Glass
Base
Flameproof Interface
Housing
18. Flameproof joint position picture
SVEX-171ExEX Monitor
Ver: 1.1
14
Problems
Reason
Method
Remarks
No image
Power off
Replace fuse
Do it oneself
Check power line
Do it oneself
Signal line off
Check signal line and pin
Do it oneself
Interference,
double image
Signal line broken
Check signal line
Do it oneself
Interference
appears in the line
Look up interference source
Do it oneself
Transfer distance is
too long
Signal transfer is less than
15 meters
Do it oneself
Display color is
unusual
Pin connection is
not good.
Check pin and receptacle
Do it oneself
Software set wrong
Start software to adjust
display effect
Do it oneself
Picture overturn
Resolution ratio
is too low
Resolution ratio set
wrong
Adjust Resolution ratio again
Do it oneself
6. Trouble shooting
7. Shipment and storage
After package, without rain or snow fall directly to product, shipment could do by air or sea and store for one year under the environment of -20~+60, humidity >90%.
8. Guarantee
For any camera produced by Veilux, we promise a one year to repair warranty. During Guarantee period, we supply free service except following situations:
User does not operate as manual book requires
User un-install the whole product by themselves
If there are additional agreements between Veilux and buyer, then agreements shall be strictly done.
Lightning or Act of God
9. Statement
Veilux owns the final design changing and final specification rights and no
SVEX-171ExEX Monitor
Ver: 1.1
15
responsibility to inform user
This manual book belongs to Veilux rights, without permits or any book inform, any
company or private copy of whole or part of the book shall be prohibited.
802 GREENVIEW DR STE 200
GRAND PRAIRIE, TX. 75050
Website: www.veilux.net
E-mail: Sales@veilux.net
Phone # 1-800-510-6528
Loading...