Veilux SVEX-151 User Manual

常州裕 硬件手册
Ex-marking:
ExdBT6
Ex-certificate: Sira 07ATEX1106X
SVEX-151 EXPLOSION PROOF MONITOR
SVEX-151 EX Monitor User’s Manual
Ver: 1.0
2
BEFORE INSTALLATION, PLEASE DO CAREFULLY READ THIS MANUALBOOK..
Please install under manual required atmosphere.
To make sure the installation position is stable and safe in case any damage to camera.
To make sure all powers same as the requirements on the nameplates before camera power on.
Do not open camera body under too much humidity, otherwise the humid air getting into camera inside
cannot easily vaporize because of good sealing of camera flameproof, and this humidity may damage
camera spare parts and damage picture quality of camera.
Please connect cables correctly according to the Manual book.
Please shut off the power before repair maintenance camera.
Pay attention to protecting the flameproof surface of camera while install or un-install camera.
Welcome to call VEILUX for any help
TEL: 214-635-4855
The Art of Surveillance
SVEX-151 EX Monitor User’s Manual
Ver: 1.0
3
Content
1. INTRODUCTION............................................................................... 4
2. TECHNICAL DATA............................................................................ 4
2.1 Type Code ......................................................................... 4
2.2 Certificate .......................................................................... 5
2.3 Electrical............................................................................ 5
2.4 Technical specification...................................................... 5
2.5 Mechanical ........................................................................ 5
2.6 Environmental ................................................................... 6
2.7 Dimensions ........................................................................ 6
2.8 Installation Dimensions ..................................................... 7
3. MOUNTING..................................................................................... 7
3.1 Desktop Mounting ............................................................. 7
3.2 Ceiling Mounting............................................................... 8
3.3 Cable Treatment ................................................................ 8
3.3.1 Ex-Proof Flexible Tube ...................................... 8
3.3.2 Power Cable Connection................................... 9
4. APPLICATION ............................................................................... 10
4.1 Power On/Off .................................................................. 10
5. FLAMEPROOF STRUCTURE............................................................. 10
6. TROUBLE SHOOTING ..................................................................... 11
7. SHIPMENT AND STORAGE .............................................................. 11
8. GUARANTEE.................................................................................. 11
9. STATEMENT.................................................................................. 12
The Art of Surveillance
SVEX-151 EX Monitor User’s Manual
Ver: 1.0
4
1. INTRODUCTION
This SVEX-151 Explosion-proof Monitor as a new monitoring equipment has changed the situation that terminal
monitor could only be put in control room, it also can be used in flammable and explosive environment, supplying
a much clearer monitoring picture for customers, which advances the flexibility of system collocation greatly.
SVEX-151 adopts advanced production techniques and matured quality management system to make its quality,
performance and appearance a leading position in explosion proof monitor
ing products. This monitor owns
advantage of small volume, light weight and easy installation features,
SVEX-151 is strictly according to European Directive EC/94/9 and EN50014, Standards of GB3836.1-2000
GB3836.1—2000 Electrical apparatus for explosive atmosphere: General requirements, GB3836.2-2000
Electrical apparatus for explosive atmosphere: Flameproof ‘d’ and GB12476.1-2000 Electrical apparatus for
explosive dust: Using enclosure and limiting surface temperature for protecting elec
trical apparatus Chapter 1:
Technical requirements, the monitor housing is made of stainless steel,IP65 enclosure rating and this monitor
could be widely used in petroleum, chemical industry, jetty, port, mine, space, army and foodstuff area.
High performance LCD screen is installed inside, supplying the resolution of 1024 x 768 which could show the
picture sharply; the quick response time could show the moving picture excellently; TCO'03 guarantees the
maximal security and human engineering standard.
2. TECHNICAL DATA
2.1
Type Code
SVEX — 151 ( E x )
Ex-mark
Design number
Veilux
The Art of Surveillance
SVEX-151 EX Monitor User’s Manual
Ver: 1.0
5
2.2 Certificate
Ex-marking ExdBT6
Certificate Number Sira 07ATEX1106X
2.3 Electrical
Input Voltage 100~240VAC, 50/60Hz
Power Consumption 24 W
Electric Connection
Power 3-core cable for power
Video Input : VGA, BNC or both
2.4 Technical specification
Screen 15.1inches 38.1cm),TFT
Color 16,770,000
Point distance 0.297mm
View Distance 304.1mm (w) x 228.1mm (h)
Contrast 500: 1
Brightness 300cd / m2
Pan Horizon 140°CR5
Tilt Horizon 140°CR5
Response Time 16ms
Pan refreshing rate 38~60
KHz
Tilt refreshing rate 56~75Hz
Bandwidth 80MHz
Optimum Resolution 1024 x 768
2.5 Mechanical
Protection IP65
Construction Stainless Steel 1Cr18Ni9Ti
Weight 25Kg
The Art of Surveillance
SVEX-151 EX Monitor User’s Manual
Ver: 1.0
6
Dimensions 351(H) x 426(W) x 200(D) mm
Lens Dimensions 305 x 230 mm
Glass Thickness 12mm
Inner Dimension 3L
Cable Outlet 2
Outlet Type G-3/4”
2.6 Environmental
Air Pressure 86106KPa
Environment Temperature
Working 0~+50
Storage -20~+60
Relative Humidity
95%RH(+25)
2.7 Dimensions
P1. SVEX-151 External Size
The Art of Surveillance
SVEX-151 EX Monitor User’s Manual
Ver: 1.0
7
2.8 Installation Dimensions
P2. Fixed holes in the bottom
3. MOUNTING
3.1 Desktop Mounting
SVEX-151(Ex)monitor can be put on the desktop or fixed with screws.
P3. Desktop Installation P4. Fixed By Screws
±18° view angle is adjustable
18°18°
Fixed Holes
The Art of Surveillance
SVEX-151 EX Monitor User’s Manual
Ver: 1.0
8
P5. Adjustable Screws P6. Angle Adjustment
3.2 Ceiling Mounting
The base can be moumted on theceiling and reverse the video by the software.
P7. Ceiling Mounting P8. Angle Adjustment
3.3 Cable Treatment
While monitor leaves factory, we supply a power cable and a VGA signal cable (BNC cable). Before using, a
Ex-proof Flexible Tube should be prepared in order to make it explosion proof.
3.3.1 Ex-Proof Flexible Tube
a. As picture 9remove the Tighten Nut at the back of screen. Loose the screw connection head of Ex-proof
flexible tube for standby.
Adjustable
Joint
The Art of Surveillance
SVEX-151 EX Monitor User’s Manual
Ver: 1.0
9
P9.
b. As P10tighten the screw joint and tighten the EX tube.
P10.
3.3.2 Power Cable Connection
The power cable is 3-core. While using, an ex-proof junction box should be equipped. Connect the cables
inside of the junction box. The color definition of cables is as follows:
Table1. Cable Definition
Name Power cable
Function Live wire Neutral wire
Color Red Black
EX Tube
joint
Rubber
Ring
Washer
Cable
Outlet
OutletEX Tube
The Art of Surveillance
SVEX-151 EX Monitor User’s Manual
Ver: 1.0
10
4. APPLICATION
4.1 Power On/Off
P11. Location of Power Button
5. FLAMEPROOF STRUCTURE
Completely consider the explosive air getting into ex-proof structure, which may lead to explosion because
of some reason and to confirm and ensure camera explosion proof performance based on its structure gap,
length and max temperature it will get to.
Enclosure shall burden water pressure testing for 1.0Mpa for 10~12 seconds without leakage as pass,
which is ordered in GB3836.2-2000.
Camera surface temperature max shall not over 80 while it is working .
Cable for Monitor uses inlaid device to tighten its screw and nut.
Monitor window glass adopts steel glass to burden Impact and Heat change testing.
Push this button to turn on/off the monitor.
The Art of Surveillance
SVEX-151 EX Monitor User’s Manual
Ver: 1.0
11
P12. Flameproof Joint interface
6. TROUBLE SHOOTING
krameR dohteM nosaeR smelborP
Change fuse
Self-done
Power off
Check power cable Self-done
No image
Signal off Check signal cable and plug Self-done
Signal wire broke Check signal cable Self-done
Interfere for picture
Interfere of wire Search for interfere Self-done
Color error Bad connection of plug Check plug and socket Self-done
7. SHIPMENT AND STORAGE
After package, without rain or snow fall directly to product, shipment could do by air or sea and store for one year
under the environment of -20 ~+60  , humidity >90%.
8. GUARANTEE
For any camera produced by VEILUX, we promise half-year to change and one year to repair.
During Guarantee period, we supply free service except following situations:
User does not operate as manual book requires
User un-install the whole product by themselves
Lightning or Act of God
15 inch LCD Monito
r
Flameproo
f
Interface
Housing
Front Panel
Tempered Glass
Base
The Art of Surveillance
SVEX-151 EX Monitor User’s Manual
Ver: 1.0
12
If there are additional agreements between VEILUX and buyer, then agreements shall be strictly done
9. STATEMENT
VEILUX owns the final design changing and final specification rights and no responsibility to inform user
This manual book belongs to VEILUX rights, without permits or any book inform, any company or
private copy of whole or part of the book shall be prohibited.
Fax: 214-988-2858
Toll Free: 1 (800) 510-6528
Tel: 214-635-4855
Grand Prairie, TX 75050
802 Greenview Dr. Ste 200
Loading...