This operating instructions manual provides all the information you
need for installation and setup. Please read this information before
setting up the instrument and keep this manual accessible in the
immediate vicinity of the device.
1.2 Target group
This operating instructions manual is directed to trained qualified
personnel. The contents of this manual should be made available to
these personnel and put into practice by them.
1.3 Symbolism used
Inform
ation, tip, note
This symbol indicates helpful additional information.
Cauti
on: If this warning is ignored, faults or malfunctions can
result.
Warning: If this warning is ignored, injury to persons and/or serious
damage to the instrument can result.
Danger: If this warning is ignored, serious injury to persons and/or
destruction of the instrument can result.
applications
Ex
This symbol indicates special instructions for Ex applications.
35069-EN-081201
WEB-VV
lList
The dot set in front indicates a list with no implied sequence.
àAction
Th
is arrow indicates a single action.
1Sequence
Numbers set in front indicate successive steps in a procedure.
VH • Configuration, first steps3
2 For
your safety
or your safety
2 F
2.1 Authorised personnel
All operations described in this operating instructions manual must be
carried out only by trained specialist personnel authorised by the plant
operator.
2.2 Appropriate use
WEB-VV is a WEB portal for simple recording, presentation and
transmission of measured values. Measured values can be transmitted
via Internet, telephone lines or GSM network to the WEB-VV server.
2.3 Warning about misuse
Improper or unconventional use can lead to application-specific
dangers. The displayed measured values must only be used for
visualisation and inventory monitoring. Automatic monitoring for overfill
(overfill protection), for example, is not allowed.
2.4 General safety instructions
Installation and use of the software are carried out at your own risk. We
do not accept liability for consequential damage.
2.5 Environmental instructions
Protection of the environment is one of our most important duties. That
is why we have introduced an environment management system with
the goal of continuously improving company environmental protection.
The environment management system is ce rtified according to DIN
EN ISO 14001.
Please help us fulfil this obligation by observing any environmental
instructions that may be in this manual.
4WEB-VV
35069-EN-081201
VH • Configuration, first steps
3 Produc
t description
Scope of delivery
VMI
WEB-VV
3 Produc
t description
3.1 Scope of delivery
l WEB-VV contact data
l WEB-VV license agreement
3.2 What is VMI/WEB-VV?
VMI stands for Vendor Managed Inventory (supplier-controlled
inventory). The supplier is responsible for the inventory of his products
at the customer's location. He takes over inventory monitoring via
remote enquiry and autonomously controls the delivery of replenishments.
WEB-VV stands for simple remote enquiry, user-friendly visualisation
and long-term data archiving. Thanks to its interfaces to standard
inventory control systems (ERP systems) as well as its comprehensive
notification functions, WEB-VV is the ideal basis for all VMI solutions.
WEB-VV is based on modern Web technologies, visualisation is
carried out via any standard browser such as e.g. the Internet Explorer.
This is possible in the local network as well as world-wide via Internet.
A local installation of application software for measured value
indication is hence not necessary. The transmission of measured
values is either carried out via LAN, Internet, GSM/GPRS or telephone
line. The protected area for measured value indication is only
accessible with an individual password, the connection is established
via the secure https protocol.
The measured values are provided by on-site sensors and collected
and further processed by appropriate VEGA signal conditioning
instruments. These signal conditioning instruments transmit (timecontrolled) the measured values to the defined WEB-VV server. The
indication of the measured values can be a bar graph or a table. Apart
from the current measured values, history data are also available. The
current measured values can be sent cyclically at any time also via email/SMS/fax. Event-controlled notification can also be configured.
WEB-VV is available in two versions, centrally hosted at VEGA or
locally installed a t the customer's location.
Hosting at VEGA
35069-EN-081201
WEB-VV
At its own computer centre VEGA provides the server for adminstra-
tion of the inventory data. Through interruption-free power supply,
redundant hardware and automatic backup, 24-hour availablility is
guaranteed 365 days per year. Installation, administration and future
software updates are included in the one-time installation fee.
VH • Configuration, first steps5
3 Produc
t description
Hosting locally
VEGA pr
setup and adminstration are carried out by the customer. Operation as
well as maintenance, backup and software update also lie within the
customer's responsibility. The precondition is that the customer must
have his own IT infrastructure with appropriately qualified personnel.
ovides the instrument technology and software. Installation,
6WEB-VV
35069-EN-081201
VH • Configuration, first steps
4 Operati
on
WEB-VV contact data
WEB-VV license agree-
ment
Setup device network
4 Operati
on
4.1 Prerequisites
The following prerequisites must be fulfilled in order to use WEB-VV:
You receive this document with the order confirmation. Enter your
company data, including an appropriate contact person. A contact for
the user account of the supervisor is also required. Please send the
contact data to the fax number given in the form.
After sending in the contact data, you receive the license agreement.
This agreement includes the services, the duties and the liabilities ofboth parties. The access data for the first login are also included.
A device network consists of a signal conditioning instrument
VEGAMET/VEGASCAN/PLICSRADIO with connected sensors and
the respective measurement loops. If signal conditioning instruments
are integrated via Ethernet interface into a company network with
internet access, the measured values can be transmitted directly via
http (Port 80) to the WEB-VV server. If the measured values should be
transmitted via modem (analogue/ISDN/GSM/GPRS), an appropriate
communication device is also required. In addition, the access data of
a provider are required in order for the signal conditioning instrument
to gain access to the Internet.
Set up the signal conditioning instrument with PACTware according to
the respective instructions manual as well as the online help available
in PACTware and start a test transmission of the measured values.
35069-EN-081201
WEB-VV
Fig. 1: Test
VH • Configuration, first steps7
transmission WEB-VV measured values
4 Operati
on
ct the WEB-VV administrator after setting up the device network.
Conta
The administrator then assigns the new device network accordingly
and releases the measured values for indication.
4.2 Start WEB-VV the first time
WEB-VV registration
Adjustment system
Start your web browser and enter the URL:
Enter the access data from the User Agreement in the entry screen. As
an alternative, you can visit a demo plant to get acquainted with the
program - for this you do not need a password.
Fig. 2: WEB-VV registration
e WEB-VV user interface is divided into different sections. These
Th
sections fulfil the functions described below:
https://we
b-vv.vega.com.
8WEB-VV
35069-EN-081201
VH • Configuration, first steps
Loading...
+ 16 hidden pages