Vector Controls B2235765 User Manual

TCY-MT-U
Technical Specifications
Item Name
Item code
Control Type
Key-data
TCY-MT2-U-W01
40-10 0044-01
Cooling only
Compact PI controller with: 2 TI, 1 AO
TCY-MT2-U-W02
40-10 0044-02
Heating only
TCY-MT2-U
40-10 0044
2-Pipe system
TCY-MT4-U
40-10 0046
4-Pipe system
1 TI, 2 AO
Accessories
S-Tn10-2 SD-Tn10-12-2 SD-Tn10-20-2 SDB-Tn10-12-1 SDB-Tn10-20-1 SOA-Tn10
40-20 0001 40-20 0002 40-20 0003 40-20 0124 40-20 0133 40-20 0006
Flying lead sensor with 6 ft cable Flying lead duct sensor 4.7 inch immersion depth, 6 ft. cable Flying lead duct sensor 7.8 inch immersion depth, 6 ft. cable Duct sensor with housing, 4.7 inch immersion depth Duct sensor with housing, 7.8 inch immersion depth Outdoor sensor
Housing: U = Vertical (2x4”) housing, Standard is square housing Function: 2 = 2 = 2-Pipe, 4 = 4-Pipe Input: T = Temperature, H = Humidity Output: M = Modulating, B = Binary Series: TCY
T C Y
T - M - U
(
)
2

Features

Temperature PI control for HVAC systems. Up to 2 modulating outputs for DC 0–10V with 10mV resolution. 1 internal temperature sensor and up to 2 external sensor inputs Multiple remote control functions on external input Password protected programmable user and control parameters Blue backlight

Applications

Various temperature control applications Stand-alone VAV control for pressure independent actuators Water-only systems: Radiator, floor heating or chilled ceilings Individual room control for offices, residential, hotel rooms, meeting rooms,

General description

The TCY-MT-U is a stand-alone electronic temperature controller with one control loop. It may use up to 2 PI-sequences. The TCY-MT-U features one internal NTC temperature sensor, up to two external sensor inputs and up to two analog outputs. The configuration has been reduced to a minimum to allow for simple and off-the­shelve usage. For more advanced features and current inputs and outputs the TCI product range is recommended. The TCY-MT-U can be configured using the standard operation terminal. No special tool or software is required.
etc.

Name

Ordering

Selection of actuators and sensors

Temperature sensors:

Use only our approved NTC sensors to achieve maximum accuracy. Recommended is SDB-Tn10-20 as Duct sensor, SRA­Tn10 as Room sensor and SDB-Tn10-20 with AMI-S10 as immersion sensor.

Modulating actuators:

Choose actuators with an input signal type of 0–10V DC or 2–10V DC.
Doc: 70-07-0176 V1.2, 20161208 © Vector Controls GmbH, Switzerland Page 1 Subject to alteration www.vectorcontrols.com
TCY-MT-U

Technical Specifications

Power Supply
Operating Voltage
24 V AC/DC ± 10 %, 50/60 Hz, Class 2 48VA max
Power Consumption
Max. 1.5 VA
Electrical Connection
Terminal Connectors, wire 0.34-2.5 mm2 (AWG 24…12)
Signal inputs
Temperature Input
Range
0-50 °C (32-122 °F)
Accuracy
0.5 K
Signal outputs
Analog Outputs Output Signal Resolution Maximum Load
AO1, For TCY-MT4-U AO2 DC 0-10 V
9.76 mV (10 bit) 10 mA
Environment
Operation Climatic Conditions Temperature Humidity
To IEC 721-3-3 class 3 K5 0-50 °C (32-122 °F) <95 % r.H. non-condensing
Transport & Storage Climatic Conditions Temperature Humidity Mechanical Conditions
To IEC 721-3-2 and IEC 721-3-1 class 3 K3 and class 1 K3
-25-70 °C (-13-158 °F) <95 % r.H. non-condensing class 2MT2
Standards
conform according to EMC Standard 89/336/EEC EMEI Standard 73/23/EEC
EN 61 000-6-1/ EN 61 000-6-3
Product standards Automatic electrical controls for household and similar use Special requirement on temperature dependent controls
EN 60 730 –1
EN 60 730 – 2 – 9 Degree of Protection
IP30 to EN 60529
Safety Class
III (IEC 60536)
Cover, back part Mounting Plate
Fire proof ABS plastic (UL94 class V-0) Galvanized Steel
General
Dimensions (H x W x D)
Front part: 112 x 73 x 15 mm (4.4” x 2.9” x 0.6”) Power case: ø 58 x 32 mm (ø 2.3” x 1.3”)
Weight (including package)
270 g (9.5 oz)
58 (2.3)
112 (4.4)
73 (2.9)
32 (1.2)
15
(0.6)
Technical specifications

Dimensions [mm] (inch)

Doc: 70-07-0176 V1.2, 20161208 © Vector Controls GmbH, Switzerland Page 2 Subject to alteration www.vectorcontrols.com
TCY-MT-U
Technical Specifications
X
T INT
0V (COM)
24V AC/DC
2
G
TCY-MT4-U
1
G0
3
G0
Signal
COM
4
U1
Heat OUT
7 M
Signal
COM
8
X1
X
T EXT
IN
5
G0
Signal
COM
6
U2
Cool OUT
X
T INT
0V (COM)
24V AC/DC
2
G
TCY-MT2-U
1
G0
3
G0
COM
4
U1
H/C
OUT
X
T CO
IN
6
X2
COM
5 M 8 X1
X
T EXT
IN
7 M
COM

Installation and safety advice

Caution! This device is intended to be used for comfort applications. Where a device failure endangers human life and/or
property, it is the responsibility of the owner, designer and installer to add additional safety devices to prevent or detect a system failure caused by such a device failure. Vector Controls or its affiliates cannot be held liable for any damage caused by such a failure. Failure to follow specifications and local regulations may endanger life, cause equipment damage and void warranty.

Connection diagram

Description:
G0 Power supply: 0V, -24VDC, internally connected to signal common G Power supply: 24VAC, +24VDC M Signal common: Common 0 potential for analog inputs and analog outputs. X1 External temperature input: NTC 10kΩ @ 25°C (77°F)
TCY-MT2-U: X2 Changeover input: NTC 10kΩ @ 25°C (77°F) U1 Analog output: 0…10 V DC
TCY-MT4-U: U1 Analog heating output: 0…10 V DC U2 Analog cooling output: 0…10 V DC

Installation

The unit consists of two parts: (a) The power case with attached mounting plate and (b) the front part.

Mounting location

On an easy accessible interior wall, approx. 1.5 m (4.5’) above the floor in an area of average temperature. Avoid exposure to direct sunlight or other heat sources, e.g. the area above radiators and heat emitting electrical
equipment.
Avoid locations behind doors, outside walls and below or above air discharge grills and diffusers. Location of mounting is less critical if external temperature sensors are used

Installation

1. Connect the wires to be connected to the terminals of the power case according to wiring diagram
2. Install the mounting plate to the flush mounting box. Make sure that the nipple with the front holding screw is
facing to the ground. Make sure the mounting screw heads do not stand out more than 5 mm (0.2”) off the surface of the mounting plate.
3. Ensure that the jumpers are set correctly.
4. Slide the two latches located on the top of the front part into the hooks at the upper side of the mounting plate.
5. Carefully lower the front part until the interconnector reaches the mounting-plate. Continue pressing in a gentle
way until the front part is fully connected. While inserting the connectors, a slight resistance can be felt. This is normal. Do not use excessive force!
6. With a Philips-type screw driver of size #2, carefully tighten the front holding screw to secure the front part to
the mounting plate. This screw is located on the front lower side of the unit. There is no need to tighten the screw too much.
Doc: 70-07-0176 V1.2, 20161208 © Vector Controls GmbH, Switzerland Page 3 Subject to alteration www.vectorcontrols.com
Loading...
+ 5 hidden pages