Vector VEC022 User Manual

1
Jump-Start System
12 VOLT DC POWER SUPPLY
VEC022
IF YOU SHOULD EXPERIENCE A PROBLEM WITH YOUR
PURCHASE CALL TOLL FREE 866-584-5504. IN MOST
CASES A SERVICE REPRESENTATIVE CAN RESOLVE
OWNER’S MANUAL AND
W
ARRANTY INFORMA
TION
KEY INFORMATION YOU SHOULD
KNOW:
• Jump-start any engine system with a standard 12 volt DC battery
• Easy-to-read series of LED charge indicators
• Jump-Start System can be recharged from any standard 110/120 volt AC power source
• Built-in Emergency Area Light
BEFORE RETURNING THIS PRODUCT FOR ANY REASON,
PLEASE CALL TOLL FREE 866-584-5504
THIS MANUAL CONTAINS IMPORTANT INFORMATION REGARDING SAFETY,
OPERATION, MAINTENANCE AND STORAGE OF THIS PRODUCT. READ
CAREFULL
Y BEFORE USE, AND RETAIN FOR FUTURE REFERENCE.
4140 S.W
. 30th Ave., Ft. Lauderdale, FL 33312
Toll Free: 866-584-5504
VEC022 Manual_Final_073106.qxp 7/31/06 6:36 PM Page 1
2
CONTENTS
1. INTRODUCTION ..........................................................................................5
2. SAFETY WARNINGS ....................................................................................7
2.1 Jump-starting Instructions ....................................................................8
3. CHARGING/RECHARGING ............................................................................9
3.1 110/120 Volt AC Charging....................................................................10
3.2 12 Volt DC Charging ............................................................................10
3.3 Replace Fuse........................................................................................10
3.4 Estimated Battery Life ..........................................................................11
4. OPERATING AS A PORTABLE POWER SUPPLY..............................................11
5. EMERGENCY/AREA LIGHT ..........................................................................11
6. REPLACEMENT PARTS ..............................................................................11
6.1 Battery Replacement ............................................................................11
6.2 Battery Disposal ..................................................................................12
7. SPECIFICATIONS........................................................................................12
WARRANTY ....................................................................................................13
VEC022 Manual_Final_073106.qxp 7/31/06 6:36 PM Page 2
3
SAFETY INFORMATION
WARNING: W
arning statements identify conditions or practices that may result in
personal injury or loss of life
1. When working with lead acid batteries, always make sure immediate assistance is available in case of accident or emergency.
2. Always use protective eyewear when using this product: contact with battery acid may cause blindness and/or severe burns, be aware of first aid procedures in case of accidental contact with battery acid.
3. There is a risk of explosive gases being released when lead acid batteries are being charged or discharged. Failure to follow instructions may cause property damage, explosive hazard, and/or personal injury.
4. When connecting the battery clamps to a discharged battery, and an alarm sounds - the polarity is reversed.
5. When charging unit from a 110/120 volt AC electrical outlet in any wet or damp area, make sure that the outlet used is protected by a ground fault interrupt (GFI) Switch.
6. When charging the unit near water, do not allow the electrical cords and outlets to get wet or come near water–electrical shock could result.
7. Jump-start procedures should only be performed in a safe, dry, well­ventilated area.
8. Always store battery clamps on clamp tabs when not in use. Never touch battery clamps together, this can cause dangerous sparks, power arcing and/or explosion.
9. When using this unit in proximity to the vehicle’s battery and engine, stand the unit on a flat, stable surface, and be sure to keep all clamps, cords, clothing and body parts away from moving vehicle components.
10. Do not wear vinyl clothing when jump-starting a vehicle, friction can cause dangerous static-electricity sparks. Remove all jewelry or metal objects that could cause short circuits or react with battery acid.
11. Always disconnect the negative (Black) jumper cable first: followed by the positive (Red) jumper cable, except for positive ground systems.
12.
Never allow red and black clamps to touch each other or another common metal conductor–this could cause damage to the unit and/or create sparking/explosion hazard. Always store battery clamps on built-in clamp tabs when not in use.
13. Do not expose battery to fire or intense heat as it may explode. Before disposing of the battery, protect exposed terminals with heavy-duty electrical tape to prevent shorting (shorting can result in injury or fire).
14. Do not smoke or use inflammable items (matches, cigarette lighters, etc.) while working on a vehicle’s battery system.
15. Keep unit out of reach of children (whether stored, or in use)!
FIRST AID: SKIN: If battery acid comes in contact with skin, rinse immediately
with water, then wash thoroughly with soap and water. If redness, pain, or irritation occurs, seek immediate medical attention. EYES: If battery acid comes in contact with eyes, flush eyes immediately, for a minimum of 15 minutes and seek immediate medical attention.
VEC022 Manual_Final_073106.qxp 7/31/06 6:36 PM Page 3
4
CAUTION: Caution statements advise against certain conditions and practices
that may result in damage to vehicles, appliances and/or the Jump­Starter.
IMPORTANT:
Although this unit is delivered in a partially charged state, you must fully charge it with the supplied 110/120 volt AC charger for a full 48 hours before using it for the first time. You cannot overcharge the unit using the AC charger method.
1. Use only the supplied cords/adapters for recharging this unit. Do not recharge for more than 3-4 hours maximum using 12 volt DC method. Recharge unit after each use.
2. All On/Off switches should be in the OFF position when the unit is charging or not in use. Make sure all switches are in the OFF position before connection to a power source or load.
3. Never insert anything other than the supplied power/recharging cords or recommended appliance power/recharging cords into the 12 volt DC charging/power outlet on this unit. Do not use any accessory that is not recommended or provided by the manufacturer.
4. Do not use this unit to operate appliances that draw more than 5 amps.
5. This system is designed to be used only on vehicles with 12 volt DC battery systems. Do not connect to a 6 volt or 24 volt battery system.
6. This system is not designed to be used as a replacement for a vehicular battery. Do not attempt to operate a vehicle that does not have a battery installed.
7. Vehicles that have on-board computerized systems may be damaged if vehicle battery is jump-started. Before jump-starting, read the vehicle’s owners manual to confirm that external-starting assistance is advised.
8. Excessive engine cranking can damage a vehicle’s starter motor. If the engine fails to start after the recommended number of attempts, discontinue jump-start procedures and look for other problems that may need to be corrected.
9. Although this unit contains a non-spillable battery, it is recommended that unit be kept upright during storage, use and recharging. To avoid possible damage that may shorten the unit’s working life, protect it from direct sunlight, direct heat and/or moisture.
10. Check unit periodically for wear and tear. Replace worn or defective parts immediately. Contact Vector Customer Service department toll-free 866-584-5504.
11. Do not attempt to jump-start a frozen battery.
12. Never submerge this unit in water.
VEC022 Manual_Final_073106.qxp 7/31/06 6:36 PM Page 4
5
1. INTRODUCTION
Congratulations on selecting the VECTOR®JUMP-STARTER, and 12 VOLT DC POWER SUPPLY. This compact jump-starter is unique in the amount of energy it can supply for its size. The internal battery is a high density sealed, lead-acid battery that stores and delivers energy comparable to full sized ordinary jump­starters. Please read this guide carefully before use to ensure optimum performance and avoid damage to the unit or items that you are using it with.
The VECTOR
®
JUMP-STARTER & 12 VOLT DC POWER SUPPLY is a compact, durable and portable jump-start system for vehicles and boats that have a standard 12 volt battery system. This self-contained, rechargeable system will start most vehicles and boats without the need for a host vehicle or 110/120 volt AC power supply. It can also be used as a safe, portable source of 12 volt DC electric power in remote locations and/or emergency situations. It is ideal for use with Vector 12 volt DC cordless, portable, rechargeable products and MAXXSST DC/AC Power Inverters.
Use the VECTOR JUMP-START SYSTEM to:
• Jump-start any engine system with a standard 12 volt DC battery: boat;
truck; car; airplane; RV; personal watercraft; snowmobile; garden tractor; gasoline engine generator, etc.
• Operate: 12 volt DC fans, fluorescent worklights, cellular phones (can quick-
charge a cellular phone by using the phone’s 12 volt DC adapter cord), spotlights, TVs, portable radios, cassette or CD players, and more. Operate: Certain 110/120 volt AC accessories (requires a Vector 12 volt power inverter, sold separately).
The JUMP-START SYSTEM has an easy-to-read series of LED (Light Emitting Diode) charge indicators that show the level of charge in the battery. Charge level can be viewed when the Battery Level Status pushbutton is pressed. A 12 volt DC accessory outlet is provided for use with appliances that can operate from a vehicle 12VDC accessory outlet. This allows maximum portability and utility when the Jump-Start System is used in remote locations.
The Jump-Start System can be recharged from any standard 110/120 volt AC power source using the supplied AC Recharge Adapter. The adapter barrel connector attaches to the Recharge Port on the front right of the jump-starter.
A built-in 12 volt DC appliance outlet and the appropriate DC/DC charging/adapter cord is used to recharge the battery from another 12 volt DC source. When pressed, the Battery Level Status pushbutton will show the battery level status (from LOW to HIGH). The green LED (HIGH) indicator illuminates when the unit is fully charged and recharging can be discontinued. An ON/OFF pushbutton operates the built-in work/emergency light.
VEC022 Manual_Final_073106.qxp 7/31/06 6:36 PM Page 5
Loading...
+ 10 hidden pages