Vector VEC012B User Manual

OWNER’S MANUAL AND
WARRANTY INFORMATION
THIS MANUAL CONTAINS IMPORTANT INFORMATION REGARDING SAFETY,
OPERATION, MAINTENANCE AND STORAGE OF THIS PRODUCT. READ
CAREFULLY BEFORE USE, AND RETAIN FOR FUTURE REFERENCE.
4140 S.W. 28th Way, Ft. Lauderdale, FL 33312
Toll Free: (866) 584-5504
IF YOU SHOULD EXPERIENCE A PROBLEM WITH YOUR VECTOR
VECTOR SERVICE REPRESENTATIVE CAN RESOLVE YOUR PROBLEM
OVER THE PHONE.
BEFORE RETURNING THIS PRODUCT FOR ANY REASON,
PLEASE CALL TOLL FREE (866) 584-5504
KEY INFORMATION YOU SHOULD KNOW:
• BUILT-IN 12V BATTERY CHARGER
• PORTABLE, CORDLESS, RECHARGEABLE
• SAFETY WARNING ALARM SYSTEM
• ULTRA BRIGHT LED AREA LIGHT
Jump ‘n Charge
12V Battery Charger and Jump Start System
VEC012B
1
IMPORTANT SAFETY INSTRUCTIONS
WARNING - RISK OF EXPLOSIVE GASES
1. WORKING IN VICINITY OF A LEAD-ACID BATTERY IS DANGEROUS. BATTERIES
GENERATE EXPLOSIVE GASES DURING NORMAL BATTERY OPERATION. FOR THIS REASON, IT IS OF UTMOST IMPORTANCE THAT EACH TIME BEFORE USING YOUR CHARGER, YOU READ THIS MANUAL AND FOLLOW THE INSTRUCTIONS EXACTLY.
2. To reduce risk of battery explosion, follow these instructions and those published by the battery manufacturer and manufacturer of any equip­ment you intend to use in vicinity of battery. Review cautionary markings on these products and on engine.
GENERAL BATTERY SAFETY
1. Use the charger for charging a 12 V LEAD-ACID battery only. It is not
intended to supply power to a low voltage electrical system other than in automotive applications. Do not use this battery charger for other types of batteries, these may burst and cause injury to persons and damage to property.
2. Use of an attachment not recommended or sold by the battery charger
manufacturer may result in a risk of fire, electric shock, or injury to per­sons and will void warranty.
3. To reduce risk of damage to electric plug and cord, pull by plug rather
than cord when disconnecting charger.
4. Use of an improper extension cord could result in a risk of fire and elec-
tric shock.
When using an extension cord make sure:
a. Pins on plug of extension cord are the same number, size, and
shape as those of plug on charger.
b. Extension cord is properly wired and in good electrical condition.
Use of an improper extension cord could result in a risk of fire and electric shock.
c. The wire size is AWG #16 (16 gauge) up to 100 feet and AWG
#14 for distances over 100 feet.
d. Pull extension cord by plug rather than cord when disconnecting
from the charger.
5. Do not operate charger with damaged cord or plug - replace immedi-
ately.
6. Do not operate charger if it has received a sharp blow, been dropped,
or otherwise damaged in any way; take it to a qualified service techni­cian.
SAVE THESE INSTRUCTIONS
2
7. Do not disassemble charger; take it to a qualified service technician when serv­ice or repair is required. Incorrect reassembly may result in a risk of electric shock or fire and will void warranty.
8. To reduce risk of electric shock, unplug charger from outlet before attempting any maintenance or cleaning. Turning off controls will not reduce this risk.
9. Do not expose charger to rain, snow or use when wet.
10. Never charge a frozen battery.
PERSONAL PRECAUTIONS AND SAFETY
1. Another person should be within range of your voice or close enough to come to
your aid when you work near a lead-acid battery.
2. Fresh water and soap should be nearby in case battery acid contacts skin,
clothing or eyes.
3. Wear complete eye protection and clothing protection. Avoid touching eyes while
working with a battery. Acid, acid particles or corrosion may get into eyes. Immediately flood eye with cold water (Eye Wash Station) for at least 10 minutes and seek medical attention immediately.
4. If battery acid contacts skin or clothing, wash immediately with soap and water.
5. NEVER smoke or allow a spark or flame in vicinity of battery or engine.
CAUTION: Dropping a metal tool onto battery might spark or short-circuit the battery
or other electrical part that may cause explosion.
6. Remove personal metal items such as rings, bracelets, necklaces, and watches
when working with a lead acid battery. A lead-acid battery can produce a short­circuit current high enough to cause a severe burn.
CAUTION:
Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits for a Class
B digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instruc­tions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installa­tion. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the fol­lowing measures:
- Reorient or relocate the receiving antenna
- Increase the separation between the equipment and receiver
- Connect the equipment to an outlet on a circuit different from that to which the receiver is connected
- Consult the dealer or an experienced radio/TV technician for help
AC POWER CORD CONNECTION
This charger is equipped for use with an extension cord. The extension cord must be first connected to the charger’s polarized plug. Only then should the extension cord be plugged into a properly installed 110/120VAC outlet in accordance with all local codes and ordinances. This battery charger plug is for use with 110/120VAC ONLY.
DANGER: NEVER alter the extension cord or plug – if it will not fit an outlet, have a
proper outlet installed by a qualified electrician. An improper connection may result in electric shock and will void warranty.
INTRODUCTION AND FEATURES
Use the Jump-Start/12 Volt DC Battery Charger System:
To jump-start any engine system with a standard 12 volt DC battery: boat; truck; car; air-
plane; RV; personal watercraft; snowmobile; garden tractor; gasoline engine gener­ator, etc.
As a 12 Volt DC Power Supply: Operate 12 volt DC fans, inflators, fluorescent worklights,
cellular phones (can quick-charge a cellular phone by using the phone’s 12 volt DC adapter cord), spotlights, TVs, portable radios, cassette or CD players, and more.
As a 12 Volt DC Battery Charger: The Jump ‘n Charge system has an easy-to-read series of
LED (Light Emitting Diode) charge indicators that show when the unit is fully charged, or the level of charge in the battery. Charge level can be viewed when the charge status pushbutton is pressed. A 12 volt DC power accessory outlet is provided for use with appli­ances that can operate from a vehicle 12 volt DC accessory outlet. This allows maxi­mum portability and utility when the Jump-Start System is used in remote locations.
The Jump ‘n Charge system can be recharged from any standard 110/120 volt AC power source using a household extension cord.
A built-in 12 volt DC appliance outlet and the appropriate DC/DC charging/adapter cord is used to recharge the battery from another 12 volt DC source. When pressed, the CHARGE STATUS button will show the battery power level status (from LOW to HIGH). The green LED full indicator illuminates when the unit is fully recharged and charging can be discontinued. An ON/OFF switch operates the built-in work/emergency light.
FEATURES
• Exclusive automatic ON/OFF power control ensures safety and resists sparking
• Reverse polarity warning alarm sounds to alert a reverse polarity connection
• Ultra bright LED emergency area light
• 12 volt DC charging cord for charging from vehicle
• High-density, 19Ah, sealed, non-spillable battery
• 12 volt DC power outlet for accessories and appliances
• Heavy duty welder-type cable and clamps
• Clamps power-on only with proper polarity connection
• Digital display shows charge rate, operating mode, fault codes and FUL when charged
• Instant Start capability
• Three-stage automatic rapid charging
• Compensate for low AC from extension cord use
3
SMART BATTERY CHARGER
The charger portion of the system is microprocessor-based and has three charge rate set­tings, controlled by one switch. (See Figure 1).
1. Stage One- Rapid Start Charge
- delivers maximum charging amperage to “wake up” any serviceable 12 volt battery. When battery reaches a maximum safe prede­termined voltage, the charger will automatically move into Stage 2 of the charging process.
2. Stage Two- Absorption Charge
maintains the maximum possible charge at a con­stant, safe, predetermined voltage. During the phase, voltage absorption regula­tion charge, the charging voltage remains constant, while the actual charging cur­rent is reduced to allow for the maximum proper internal chemical energy transfer.
3. Stage Three- T
op-Off Charge voltage is automatically maintained and reduced to a predetermined level while current is adjusted for a safe, effective 100% battery charge (step-down regulation mode). This is ideal for topping off batteries that have been in storage.
Stage One
BEEP
BEEP
OFF
Stage Two
Stage Three
CHARGING COMPLETE
Amps Size
2 amps
smaller batteries as in lawn mowers, snowmobiles, motorcycles, etc.
4 amps mid sized batteries as in watercraft and motorcycles
6 amps automobile batteries
4
BATTERY STATUS DISPLAY
To check the battery status press the PUSH button ‘For Battery Low Level Battery Status’.
1. If all 4 indicators light (1 green light and 3 red lights) the battery is fully charged.
2. If 3 red indicators light, the battery is useable.
3. If 2 red indicators light, the battery is 1/2 discharged. Recharging is recommended.
4. If 1 red indicator lights, the battery needs a full recharge.
Figure 1
Loading...
+ 11 hidden pages