Vector VEC012APC User Manual

Cut here
VEC012APC
OWNER’S MANUAL &
WARRANTY INFORMATION
THIS MANUAL CONTAINS IMPORTANT INFORMATION REGARDING SAFETY, OPERA TION, MAINTENANCE AND STORAGE OF THIS PRODUCT. BEFORE USING, READ AND UNDERSTAND ALL CAUTIONS, WARNINGS, INSTRUCTIONS AND PRODUCT LABELS, PLUS YOUR VEHICLE’S BATTERY MANUFACTURER GUIDELINES. FAILURE TO DO SO COULD RESULT IN INJURY AND/OR PROPERTY DAMAGE.
4140 SW 28TH WAY, FT. LAUDERDALE, FL 33312
TEL: 954-584-4446 • FAX: 954-584-5556 • TOLL-FREE 866-584-5504
www.vectormfg.com
TWO YEAR LIMITED WARRANTY PROGRAM
This limited warranty program is the only one that applies to this product, and it sets forth all the responsibilities of Vector Manufacturing, Ltd., regarding this product. There is no other warranty, other than those described herein.
This Vector Manufacturing, Ltd. product is warranted, to the original purchaser only, to be free of defects in materials and workmanship for two years from the date of purchase without additional charge. The warranty does not extend to subsequent purchasers or users. Vector Manufacturing, Ltd. will not be responsible for any amount of damage in excess of the retail purchase price of the product under any circumstances. Incidental and consequential damages are specifically excluded from coverage under this warranty.
This product is not intended for commercial use. This warranty does not apply to accessories or damage to units from misuse or incorrect installation. Misuse includes wiring or connecting to improper polarity power sources.
RETURN/REPAIR POLICY: Defective products, other than accessories, may be returned postage prepaid to Vector Manufacturing. Any defective product, other than accessories, that is returned to Vector Manufacturing within 30 days of the date of purchase will be replaced free of charge. If such a product is returned more than 30 days but less than two years from the purchase date, Vector Manufacturing will repair the unit or, at its option, replace it free of charge.
If the unit is repaired, new or reconditioned replacement parts may be used, at Vector Manufacturing’s option. A unit may be replaced with a new or reconditioned unit of the same or comparable design. The repaired or replaced unit will then be warranted under the terms of the remainder of the warranty period. The customer is responsible for the shipping charges on all returned items after 30 days. During the warranty period, Vector Manufacturing, Ltd. will be responsible for the return shipping charges.
LIMITATIONS: This warranty does not cover accessories, bulbs, fuses and batteries, defects resulting from normal wear and tear (including chips, scratches, abrasions, discoloration or fading due to usage or exposure to sunlight), accidents, damage during shipping to our service facility, alterations, unau­thorized use or repair, neglect, misuse, abuse, failure to follow instructions for care and maintenance, fire, flood and Acts of God.
If your problem is not covered by this warranty, call our Technical Support Department at (954) 584-4446 or toll free at 866-584-5504 for general repair information and charges if applicable. You may also contact us through our website at www.vectormfg.com.
STATE LAW RIGHTS: This warranty gives you specific legal rights. Some states do not allow limitations on how long an implied warranty lasts or the exclusion or limitation of incidental or consequential damages, so the exclusions or limitations stated herein may not apply. This warranty gives the purchaser specific legal rights; other rights, which vary from state to state, may apply.
TO REQUEST WARRANTY SERVICE FOR THIS PRODUCT: Contact Vector Manufacturing Technical Support by telephone, fax or mail. We suggest that you keep the original packaging in case you need to ship the unit. When returning a product, include your name, address, phone number, dated sales receipt (or copy) and a description of the reason for return and product serial number. After repairing or replacing the unit, we will make every effort to return it to you within four weeks.
WARRANTY ACTIVATION: Please complete Warranty Activation Card and mail to Vector Manufacturing. Enter “VEC012APC” as Model and Jump-starter /12V DC power supply as “Product Type”. All Vector Manufacturing, Ltd. products must be registered within 10 days of purchase to activate this warranty. Mail the completed registration form, along with a copy of the original sales receipt to:
ATTN.: CUSTOMER SERVICE / VECTOR MANUFACTURING, Ltd.
4140 SW 28th Way, Ft. Lauderdale, FL 33312
PH: 954-584-4446 • TOLL FREE: 866-584-5504 • Fax: 954-584-5556.
You may also contact us at our web site www.vectormfg.com.
WARRANTY MUST BE PURCHASED WITHIN 10 DAYS OF PRODUCT PURCHASE DATE.
WARRANTY IS NON-TRANSFERABLE AND NON-REFUNDABLE.
Jump-Start System
With 260 PSI Air Compressor
With 260 PSI Air Compressor
21
SAFETY INFORMA
TION
WARNINGS:
(Warning statements identify conditions or practices that may result in personal injury or loss of life)
1) When working with lead acid batteries, always make sure immediate assis­tance is available in case of accident or emergency.
2) Always use protective eyewear when using this product: contact with battery acid may cause blindness and/or severe burns, be aware of first aid proce­dures in case of accidental contact with battery acid. Compressor use may cause dust or debris to create eye hazards.
3) There is a risk of explosive gases being released when lead acid batteries are being charged or discharged. Failure to follow instructions may cause property damage, explosive hazard, and/or personal injury.
4) When connecting the battery clamps to a discharged batter y, and an alarm sounds - the polarity is reversed.
5) When charging unit from a 120 Volt AC electrical outlet in any wet or damp area, make sure that the outlet used is protected by a ground fault interrupt (GFCI) outlet.
6) When charging the unit near water, do not allow the electrical cords and outlets to get wet or come near water–electrical shock could result.
7) Jump-start procedures should only be performed in a safe, dr y, well-ventilat­ed area.
8) When using this unit in proximity to the vehicle’s battery and engine, stand the unit on a flat, stable surface, and be sure to keep all clamps, cords, clothing and body parts away from moving vehicle components.
9) Do not wear vinyl clothing when jump-starting a vehicle, friction can cause dangerous static-electricity sparks. Remove all jewelry or metal objects that could cause short circuits or react with battery acid.
10) Always disconnect the negative (Black) jumper cable first: followed by the
positive (Red) jumper cable, except for positive ground systems.
11) Never allow red and black clamps to touch each other or another common
metal conductor this could cause damage to the unit and/or create spark­ing/explosion hazard. Always store battery clamps in built-in holsters when not in use.
12) Do not expose battery to fire or intense heat as it may explode. Before dis-
posing of the battery, protect exposed terminals with heavy-duty electrical tape to prevent shorting (shorting can result in injur y or fire).
13) Do not smoke or use inflammable items (matches, cigarette lighters, etc.)
while working on a vehicle’s battery system.
14) Keep unit out of reach of children (whether stored, or in use)
FIRST AID
SKIN: If battery acid comes in contact with skin, rinse immediately with water, then wash thoroughly with soap and water. If redness, pain, or irritation occurs, seek immediate medical attention. EYES: If battery acid comes in contact with eyes, flush eyes immediately, for a minimum of 15 minutes and seek immediate medical attention.
CONTENTS
1. INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-5
2. USING VECTOR JUMPER AS A JUMP-START SYSTEM . . . . . . . . . 6
2.1 Easy, Step-by-Step Jump-starting Instructions . . . . . . . . . . . . . 7
3. CHARGING/RECHARGING . . . . . . . . . . . . . . . . . . . . . . . . . . 8-9
3.1 120 Volt AC Charging . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
3.2 12 Volt DC Charging . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
3.3 Estimated Battery Life . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
4. OPERATING AS A PORTABLE POWER SUPPLY . . . . . . . . . . . . . . 9
5. EMERGENCY/WORKLIGHT . . . . . . . . . . . . . . . . . . . . . . . . . . 10
6. COMPRESSOR/TIRE INFLATOR . . . . . . . . . . . . . . . . . . . . . . . . 10
6.1 Warnings for Compressor Use . . . . . . . . . . . . . . . . . . . . . 10
6.2 Tire Inflation or Products (w/ Valve Stem) . . . . . . . . . . . . . 10
6.3 Inflate other Articles (w/out Valve Stem) . . . . . . . . . . . . . . 10
6.4 Typical Inflation Times . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
7. REPLACEMENT PARTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
7.1 Battery Replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
7.2 Battery Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
8. SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
9. WARRANTY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4
INTRODUCTION
Congratulations on selecting the VECTOR® JUMP-STARTER, AIR COMPRESSOR and 12 VOLT DC POWER SUPPLY. This compact jump-starter is unique in the amount of energy it can supply for its size. The internal battery is a high densi­ty sealed, lead-acid battery that stores and delivers energy comparable to full sized ordinary jump-starters. Please read this guide carefully before use to ensure optimum performance and avoid damage to the unit or items that you are using it with.
A standard feature of this model is a high pressure, self-contained tire compres­sor with lighted gauge. This compressor allows quick inflation of vehicle tires to 260 PSI and with supplied adapter nozzles, inflates beach balls, rafts and virtu­ally any low-pressure inflatables. Three different sized nozzles allow for easy connection to all popular inflatables.
The VECTOR® JUMP-STARTER & 12 VOLT DC POWER SUPPLY is a compact, durable and portable jump-start system for vehicles and boats that have a stan­dard 12 Volt battery system. This self-contained, rechargeable system will star t most vehicles and boats without the need for a host vehicle or 120 Volt AC power supply. It can also be used as a safe, portable source of 12 Volt DC electric power in remote locations and/or emergency situations. It is ideal for use with Vector 12 Volt DC cordless, portable, rechargeable products and MAXXSST DC/AC Power Inverters.
Use the VECTOR JUMP-START SYSTEM to:
Jump-start any engine system with a standard 12 Volt DC battery: boat; truck; car; air-
plane; RV; personal watercraft; snowmobile; garden tractor; gasoline engine generator, etc.
Operate: 12 Volt DC fans, inflators, fluorescent worklights, cellular phones (can
quick-charge a cellular phone by using the phone’s 12 Volt DC adapter cord), spotlights, TVs, portable radios, cassette or CD players, and more.
Operate: Certain 120 Volt AC Accessories (requires a Vector 12 volt power
inverter, sold separately).
Inflate: Truck and auto tires, sports equipment, beach inflatables. Three different
adapter nozzles allows for inflation of items without a standard tire valve stem. The easy-to-read lighted pressure gauge assures accurate inflation pressures day or night.
The JUMP-START SYSTEM has an easy-to-read series of LED (Light Emitting Diode) charge indicators that show when the unit is fully charged, or the level of charge in the battery. Charge level can be viewed when the Charge Status pushbutton is pressed. A 12 Volt DC accessory socket is provided for use with appliances that can operate from a vehicle 12VDC accessory outlet. This allows maximum portability and utility when the Jump-Start System is used in remote locations.
The Jump-Start System can be recharged from any standard 120 Volt AC power source using the supplied AC Recharge Adapter. The adapter barrel connector attaches to the Recharge Port on the top panel of the jump-starter. A built-in 12 Volt appliance socket and the appropriate DC/DC charging/adapter cord is used to recharge the battery from another 12 volt DC source. When pressed, the CHARGE STATUS pushbutton will show the battery power level status on the Battery Status display (from Low to Full). The green LED full indicator illuminates when the unit is fully recharged and charging can be discontinued. An ON/OFF switch operates the built-in work/emergency light.
3
CAUTION:
Caution statements advise against certain conditions and practices that may result in damage to vehicles, appliances and/or the jump-starter.
IMPORTANT:
Although this unit is delivered in a partially charged state, you must fully charge it with the supplied 120 V olt AC charger for a full 24 hours before using it for the first time. You cannot overcharge the unit using the AC charger method.
1) Use only the supplied cords/adapters for recharging this unit. Do not recharge for more than 3-4 hours maximum using 12 Volt DC method. Recharge unit after each use.
2) All On/Off switches should be in the OFF position when the unit is charging or not in use. Make sure all switches are in the OFF position before connec­tion to a power source or load.
3) Never insert anything other than the supplied power/recharging cords or recommended appliance power/recharging cords into the 12 Volt DC charging/power socket on this unit. Do not use any accessory that is not recommended or provided by the manufacturer.
4) Do not use this unit to operate appliances that draw more than 20 amps.
5) This system is designed to be used only on vehicles with 12 Volt DC battery systems. Do not connect to a 6 Volt or 24 Volt battery system.
6) This system is not designed to be used as a replacement for a vehicular bat­tery.
7) This system has an automatic switch that only powers the jumper cables when the proper polarity and voltage are sensed. The vehicle battery must have at least two volts for this feature to operate.
8) Do not attempt to operate a vehicle that does not have a battery installed.
9) Vehicles that have on-board computerized systems may be damaged if vehi­cle battery is jump-started. Before jump-star ting, read the vehicle owner’s manual to confirm that external-starting assistance is advised.
10) Excessive engine cranking can damage a vehicle’s starter motor. If the
engine fails to start after the recommended number of attempts, discontinue jump-start procedures and look for other problems that may need to be cor­rected.
11) Although this unit contains a non-spillable battery, it is recommended that
unit be kept upright during storage, use and recharging. To avoid possible damage that may shorten the unit’s working life, protect it from direct sun­light, direct heat and/or moisture.
12) Check unit periodically for wear and tear. Replace worn or defective parts
immediately. Contact Vector Customer Service depar tment toll-free 866­584-5504.
13) Do not attempt to jump-start a frozen battery.
14) Never submerge this unit in water.
15) DO NOT over-inflate tires or other inflatables.
Loading...
+ 4 hidden pages