Vectaire ELIX 1003 Installation And Operating Instructions Manual

IPX4
ELIX 1003
3 speed continuous running
SAP Appendix Q Eligible
3 models:
- standard
- humidity control
for all domestic wet rooms
for walls or ceilings
Energy Efficient Centrifugal Fan with EC Motor
Installation and Operating Instructions
"Elix 1003” - CENTRIFUGAL FANS WITH EC MOTOR INSTALLATION and OPERATING INSTRUCTIONS
THIS LEAFLET MUST BE AVAILABLE TO THE USER
The product you have purchased is an extractor fan for exhausting directly outside or through longer lengths of ducting (up to 15m) and is suitable for wall or ceiling installation. To ensure optimum operation and guarantee a long life, please read this manual carefully. It explains how to install correctly, use and maintain the product properly. Following these instructions will ensure the reliability of the product and extend its working life.
The manufacturer will not be held responsible and will not accept any responsibility for damage caused to persons or things due to improper use with refer­ence to the precautions outlined in this leaflet.
The product, constructed using state of the art tech­nology, complies with current standards regarding electrical equipment. It conforms with the EMC 2014/30/EU European Directive regarding radio interference suppression and electro-magnetic com­patibility.
WARNING: Serious injury or death could result if these instructions are not carefully followed
Do not use this product for any purpose other than
that for which it was designed.
Remove the product from its packaging and make
sure that it has not been damaged. If in doubt, contact the supplier, authorised dealer, service centre or manufacturer to check that the product will still operate correctly. Do not attempt to use or repair the product before doing this.
Do not leave packing material within the reach of
children or unskilled people. To dispose of the pack­aging and the appliance at the end of its useful life refer to current recycling rules.
The use of any electrical product requires compli-
ance with some basic rules which are listed below:
- do not touch it with wet or damp parts of the body (e.g hands, feet).
- this appliance can be used by children aged 8 years and over, and people with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance should not be carried out by children without supervision.
• The product should be connected to the mains electricity supply or electrical outlet only if:
- the electrical voltage and frequency correspond
to those shown on the rating label.
- the capacity of the electricity supply is sufficient
to operate the product at its maximum power.
- suitable electrical protection is provided for the
product to be installed.
• The electrical supply to which the fan is connected must comply with all existing regulations. All instal­lations must comply with current IEE wiring regula­tions.
• Before maintenance or cleaning is carried out, the product must be switched off and disconnected from the mains electricity supply.
• If a fault, malfunction or anomaly of any type occurs, the fan should be isolated (switching it off and dis­connecting it from the mains electricity supply) and advice sought from qualified personnel.
• Always request original spare parts for repairs
• If the product needs to be removed, turn off the mains supply circuit-breaker and then disconnect the fan.
• The fan MUST BE installed as detailed in this leaflet
3
WARNING: Damage could be caused to the product if the installation instructions are not followed.
• The product should not be used in an ambient
temperature higher than 40°C (104°F).
• The product should not be exposed to atmospheric
agents (rain, sun, snow, etc.).
• The product or its parts should not be placed in
water or other liquids.
• Routine maintenance as described below should be carried out to check the condition of the fan.
• The air or fumes being extracted must be clean and free from greasy particles, soot, chemical and corrosive agents, flammable or explosive mixtures.
The product must be installed by professionally
qualified personnel. Incorrect installation can cause damage to people, animals or property, for which the manufacturer cannot be held liable.
• The product must be connected to the electricity supply via a double pole switch of a suitable size, with contact openings of at least 3 mm.
• If the electrical supply board (or switching device) is located some distance from the fan a means of local isolation must be provided.
• To ensure optimum operation, do not block the air intake and exit vents.
• Any ducting used must be free of blockages, and should be insulated if in an unheated area.
• The room where the product is operating must have adequate air replacement to ensure maxi­mum effectiveness.
• If the product is sited in a room containing a fuel burning appliance which is not of the balanced flue type, the installer must ensure that air replace ment is adequate both for the fan and the fuel burning appliance
• The product must not be used as an activator for water heaters, stoves, etc.
• The product must not exhaust into ducts
designed to evacuate fumes from combustion in stoves or other combustion-powered devices.
RANGE
Trickle Speed 1 - 8 lt/sec - 28.8 m³/h Trickle Speed 2 - 14 lt/sec - 50.4 m³/h ELX1003 - this fan combines the latest technology
with energy saving and efficiency. It is a quiet run­ning, 3 speed fan designed to run continuously at a pre-selectable choice of 2 trickle speeds (see jumper
switch settings). The user can boost the fan speed to its maximum performance when required by means of the cord or remove the cord and use a remote switch, light switch, PIR sensor or humidistat.
If the fan is to be ceiling mounted, the pull-cord switch should be put in the “off” position and the cord removed. A remote switch will be necessary for changing the fan speed. See wiring diagrams.
The ELX1003 is SAP Appendix Q Listed
ELX1003DT - 3 speed, continuous running fan with
delay-on timer and pull cord. The delay-on timer ver­sion will run at low speed until the boost speed (speed 2) is activated by means of the cord or, if the cord is removed, by means of a remote switch, light switch, PIR sensor or humidistat. There is a 2 minute delay before the fan starts to run at its high speed - if the boost speed is deactivated before that time lapse, the fan will continue to run at low speed. If the boost speed is activated, the fan will operate at high speed until the boost switch is turned off. After this, the fan will continue at high speed for the length of time set on the timer overrun adjustment, between 0 and 30 mins (see Trimmer Adjustment diagram). After the overrun time has elapsed, the fan will return to the slower speed.
4
ELX1003HDT - 3 speed, continuous running fan. The fan runs continuously at the pre-selected lower speed, and the boost (speed 2) will start to operate automatically when the relative humidity (adjustable between 40% and 90% +/-5% tolerance) reaches the pre-set level and will continue to operate at this speed until the humidity has been dispersed and the adjustable over-run timer (adjustable from 0 to 30 minutes) has completed its cycle. The boost speed can also be activated by as described for model ELX1003DT
ELX1003DL - 3 speed, continuous running fan with Data Logger. For operation and monitoring of the Data Logger, please refer to separate Data Logger instructions enclosed. (Contact Vectaire Ltd for any further clarification.)
5
INSTALLATION
1. Check there is nothing missing in box and
remove front cover.
2. Drill hole in wall - allow extra width if using
ducting - it is the installer's responsibility to use the appropriate core cutter to obtain the correct hole diameter.
3. Remove circuit board cover.
4. Use fan assembly as template to mark drill holes.
5. Drill 4 x 6mm dia holes.
6. Fit wall plugs.
7/8 Decide whether to have cable access from
rear (recessed) or top (surface) of fan - if from top ensure that included grommet is properly fixed. (See dia 8). If cable is to come through rear of fan, fit rubber ring (included) .
9. Screw fan to wall.
10. Connect cable using cable clamp -
SEE WIRING DIAGRAMS FOR SPECIFIC MODELS
NB this fan is double insulated and does not need to be earthed
11. Before replacing circuit board cover choose speed of fan and set delay-on timer (if applica­ble) SEE JUMPER SWITCH SETTINGS BELOW
12. Replace front cover.
N.B This fan is NOT suitable for use with a Gravity Grille. It should be installed using either a Cowl or Fixed Grille.
IMPORTANT
If the fan is installed in a ceiling with a vertical duct passing through an unheated space, a condensation trap MUST be fitted. Any ducting in an unheated space should also be insulated according to the lat­est Building Regulations recommendations in the Domestic Ventilation Compliance Guide. Failure to do this could result in condensation affecting the opera­tion of the fan and cause damage to the ceiling.
If the fan is to be ceiling mounted, the pull-cord switch should be put in the “off” position and the cord removed. A remote switch will be necessary for changing the fan speed. See wiring diagrams.
INSTALLATION
1
2
4
5
3
6
6
7
8
9
10
7
INSTALLATION
11
12
8
INSTALLATION
ELXs - 3 Speed with Cord
WIR
ING
D
IAGR
AM
S
ELXs - 3 Speed via remote switch
N.B When installing fans via a remote switch, pullcord switch must be left in "off" position and the cord removed.
9
JUMPER SWITCH
These fans are designed to run continuously at one of 2 lower speeds fixed at installation using the jumper switch.
12
14
13
15
ELX1003 Minimum Speed Jumper 1
ELX1003 Speed 2 Jumper 2
ELX1003DT ELX1003HDT Minimum Speed Jumpers 1 and 3.
To DISABLE delay-on timer remove Jumper 3
ELX1003DT ELX1003HDT Speed 2 Jumpers 2 and 3.
To DISABLE delay-on timer remove Jumper 3
TRIMMER ADJUSTMENT
To adjust the humidistat and timer trimmers, remove the front cover and cir­cuit board cover of the fan to access the trimmers.
The humidistat (HY) can be adjusted between 40% and 90% relative humidity. Turn clockwise to decrease sensitivity and set at a higher level of relative humidity.
The timer (TM) is adjustable between 0 and 30 minutes. Turn the trimmer clockwise to increase the overrun time, or anti-clockwise to decrease it.
DISMANTLING & RECYCLING
This product has been designed and constructed using high-quality materials and components that can be recycled or re-used.
MAINTENANCE
Before any maintenance or cleaning operation, switch off the fan and disconnect it from the main power supply. The filter can be easily removed and carefully washed. The front cover can be cleaned with a dry cloth or soft brush. The fan must not come into contact with any kind of liquid or solvent. If this should occur, contact a qualified technician before reassembling the fan.
NOTE: The motor does not require lubrication as it is maintenance free "sealed for life" type.
10
Cod. 5F12245: Rev.1