Vantec EZ SWAP MRK-M3501T, EZ SWAP MRK-M3505T, EZ SWAP MRK-M3504T, EZ SWAP MRK-M3503T Installation Manual

Page 1
Verify the package contents
1.
Remove all carrier trays
2.
Install storage unit into an open 5.25” drive bay and secure the unit using the correct mounting screws shown on both sides of the storage unit
3.
Connect power and SATA/SAS* data cable on the back of the storage unit
4.
Install HDDs/SSDs on to the carrier trays using the 3/4 correct mounting screws shown on the underside of the tray
5.
Carefully slide the tray with the mounted hard drive into the storage bay, close the securing arm and lock the tray
6.
Compruebe el contenido del paquete Vericare i contenuti della confezione Lieferumfang prüfen Vériez le contenu de l'emballage
梱包内容を確認します 确认包装内容
Quite toda las bandejas portadoras Rimuovere tutti i cassetti Alle Trägereinsätze entfernen Retirez tous les plateaux de support
キャリアトレーをすべて取り除きます 移除所有拖盘
Instale la unidad de almacenamiento en una bahía de unidades de 5,25” y je la unidad utilizando los tornillos de instalación correctos mostrados a ambos lados de la unidad almacenamiento Installare l’unità d’archiviazione in un alloggio unità 5,25” e ssarla su entrambi i lati utilizzando le viti appropriate Installieren Speichereinheit in einem oenen 5,25 Speichergerät in einem freien 5,25-Zoll-Laufwerkseinschub installieren und das Gerät mit Hilfe der richtigen Montageschrauben an beiden Seiten des Speichergerätes befestigen Installez l'unité de stockage dans un logement de lecteur 5,25" ouvert et xez l'appareil à l'aide des vis de montage adéquates, comme indiqué sur les deux côtés de l'unité de stockage
空いている5.25インチドライブベイにストレージユニッ トを配置し、ユニットの両側に表示されている適切なマ ウントねじを使用して固定します 将本装置安装至5.25”硬盘架上,并注意使用正确的螺丝 来固定此装置
Conecte el cable de datos SATA/SAS* y el de alimentación en la parte posterior de la unidad de almacenamiento
* La unidad SATA tiene que conectarse a la controladora SATA y las unidades SAS a la controladora SAS
Collegare il cavo d’alimentazione ed il cavo dati SATA/SAS* sulla parte posteriore dell’unità d’archiviazione
* L’unità SATA DEVE essere collegata al controller SATA e le unità SAS DEVONO essere collegate al controller SAS
Netz- und SATA/SAS*-Datenkabel an der Rückseite des Speichergerätes anschließen
* SATA-Festplatten MÜSSEN mit dem SATA-Controller und SAS-Festplatten MÜSSEN mit dem SAS-Controller verbunden werden
Branchez l'alimentation et le câble de données SATA / SAS* à l'arrière de l'unité de stockage
* Le lecteur SATA DOIT être connecté au contrôleur SATA et les lecteurs SAS DOIVENT être connectés au contrôleur SAS
電源およびSATA/SAS*データケーブルをストレージユニ ットの背面に接続します
* SATAドライブはSATAコントローラに接続し、SASドライブは SASコントローラに接続する必要があります
连接背面的电源线与SATA/SAS*缆线
* SATA/ SAS需连接至各自相对应的插槽
Instale las unidades de disco duro y de estado sólido en las bandejas portadoras utilizando 3/4 tornillos de instalación correctos mostrados en la parte inferior de la bandeja Installare le unità HDD/SSD nei cassetti utilizzando le 3/4 viti appropriate come mostrato sulla parte inferiore del cassetto HDDs/SSDs an den Trägereinsätzen installieren; dazu die 3/4 richtigen Montageschrauben an der Unterseite des Einsatzes verwenden Installez les disques durs / SSD sur les plateaux de support en utilisant les vis de xation de 3/4 adéquates, comme indiqué sur la face inférieure du plateau
キャリアトレーの下部に示されているとおりに、 HDD/SSDを3/4サイズの適切なマウントねじで設置しま す 将HSS/SSD安装到托盘上,并于拖盘下方使用3/4个螺丝 固定
Deslice con cuidado la bandeja con la unidad de disco duro montada en la bahía de almacenamiento, cierre el brazo de seguridad y bloquee la bandeja Fare scorrere delicatamente il cassetto con il disco rigido installato nell’alloggio, chiudere il braccio di ssaggio e bloccare il cassetto Einsatz mit der montierten Festplatte vorsichtig in den Speichereinschub schieben, Sicherungsarm schließen und Einsatz verriegeln Faites glisser délicatement le plateau avec le disque dur monté dans le logement du lecteur, refermez le bras de xation et verrouillez le plateau
ハードドライブをマウントしたトレーをゆっくりとスト レージベイにスライドして入れ、固定アームを閉じてト レーをロックします 小心的将锁上硬碟的拖盘滑入插槽,关闭门板并上锁
Mounting 2.5” HDD/SSD Secure using 3 Screws
Mounting 3.5” HDD/SSD Secure using 4 Screws
x1
Key x2
Mounting Screws
SATA/SAS Cable Power Cable
Mounting 2.5” HDD/SSD Secure using 3 Screws
Mounting 3.5” HDD/SSD Secure using 4 Screws
x3
Key x2
Mounting Screws
Mounting 2.5” HDD/SSD Secure using 3 Screws
Mounting 3.5” HDD/SSD Secure using 4 Screws
x4
Key x2
Mounting Screws
Mounting 2.5” HDD/SSD Secure using 3 Screws
Mounting 3.5” HDD/SSD Secure using 4 Screws
x5
Key x2
Mounting Screws
Page 2
v 1.01
www.vantecusa.com
Model: MRK-M3501T/MRK-M3503T/MRK-M3504T/MRK-M3505T
LED Indicators (L01)
GREEN - Power ON GREEN with ORANGE Blink - Disk Activity RED - Drive Powered, but no data connection on Back No LED - No power to the Drive Bay, No drive in the Tray
Power Connector (P01)
Power Connection for the single Bay
Drive Bay – LED – DATA Connectors
Drive Bay 1(B01) – L01 – D01
[Corresponding Drive Bay, LED and DATA Connectors (on Back)]
Note:
1) You can mix SATA and SAS drives in the same storage unit, but SATA drives HAVE to be connected to SATA controller and SAS drive HAVE to be connected to SAS controller SAS drive only support Primary Channel
HDD Activity LED Switch (SW1)
ON - Show Disk Activity OFF - Show Green Power LED (If Drive(s) is in the tray)
LED Indicators (L01-L05)
GREEN - Power ON GREEN with ORANGE Blink - Disk Activity RED - Drive Powered, but no data connection on Back No LED - No power to the Drive Bay, No drive in the Tray
LED Temperature (T01)
Normal - Green LED Exceeding Set Temperature - Red LED
FAN1
- Fan pull air from the front of the Storage Bays
- Fan Size: 80 x 80 mm Fan
- Fan Status (F01) - will show Red LED if fan Fails
LED Fan Status (F01)
Normal - Green LED Fan Failure - Red LED
Drive Bay – LED – DATA Connectors
Drive Bay 1(B01) – L01 – D01 Drive Bay 2(B02) – L02 – D02 Drive Bay 3(B03) – L03 – D03 Drive Bay 4(B04) – L04 – D04 Drive Bay 5(B05) – L05 – D05
[Corresponding Drive Bay, LED and DATA Connectors (on Back)]
Note:
1) You can mix SATA and SAS drives in the same storage unit, but SATA drives HAVE to be connected to SATA controller and SAS drive HAVE to be connected to SAS controller
2) SAS drive only support Primary Channel
Fan Speed Switch (SW1)
LOW - 2400 rpm HIGH- 3000 rpm
HDD Activity LED Switch (SW2)
ON - Show Disk Activity OFF - Show Green Power LED (If Drive(s) is in the tray)
Default Internal Storage Unit Temperature set to 60°C, you can change the jumper to either 55°C, 60°C or 65°C Fan Status LED, Set via FR, F+, FG Temperature Status LED, set via TR, T+, TG Hard Drive Activity LED set via +HDD, 1;+HDD, 2;+HDD, 3; +HDD, 4; +HDD, 5
Power Connector (P01, P02)
Dual Power Connection for all 5 Bays
Note:
1) Two Power Connectors must be connected from the system power supply
2) Power load balance by all attached drives
LED Indicators (L01-L04)
GREEN - Power ON GREEN with ORANGE Blink - Disk Activity RED - Drive Powered, but no data connection on Back No LED - No power to the Drive Bay, No drive in the Tray
LED Temperature (T01)
Normal - Green LED Exceeding Set Temperature - Red LED
Drive Bay – LED – DATA Connectors
Drive Bay 1(B01) – L01 – D01 Drive Bay 2(B02) – L02 – D02 Drive Bay 3(B03) – L03 – D03 Drive Bay 4(B04) – L04 – D04
[Corresponding Drive Bay, LED and DATA Connectors (on Back)]
Note:
1) You can mix SATA and SAS drives in the same storage unit, but SATA drives HAVE to be connected to SATA controller and SAS drive HAVE to be connected to SAS controller
2) SAS drive only support Primary Channel
Fan Speed Switch (SW1)
LOW - 2400 rpm HIGH- 3000 rpm
HDD Activity LED Switch (SW2)
ON - Show Disk Activity OFF - Show Green Power LED (If Drive(s) is in the tray)
Default Internal Storage Unit Temperature set to 60°C, you can change the jumper to either 55°C, 60°C or 65°C Fan Status LED, Set via FR, F+, FG Temperature Status LED, set via TR, T+, TG Hard Drive Activity LED set via +HDD, 4;+HDD, 3; +HDD, 2; +HDD, 1
FAN1
- Fan pull air from the front of the Storage Bays
- Fan Size: 80 x 80 mm Fan
- Fan Status (F01) - will show Red LED if fan Fails
LED Fan Status (F01)
Normal - Green LED Fan Failure - Red LED
Power Connector (P01, P02)
Dual Power Connection for all 4 Bays
Note:
1) Two Power Connectors must be connected from the system power supply
2) Power load balance by all attached drives
LED Indicators (L01-L03)
GREEN - Power ON GREEN with ORANGE Blink - Disk Activity RED - Drive Powered, but no data connection on Back No LED - No power to the Drive Bay, No drive in the Tray
LED Temperature (T01)
Normal - Green LED Exceeding Set Temperature - Red LED
Drive Bay – LED – DATA Connectors
Drive Bay 1(B01) – L01 – D01 Drive Bay 2(B02) – L02 – D02 Drive Bay 3(B03) – L03 – D03
[Corresponding Drive Bay, LED and DATA Connectors (on Back)]
Note:
1) You can mix SATA and SAS drives in the same storage unit, but SATA drives HAVE to be connected to SATA controller and SAS drive HAVE to be connected to SAS controller
2) SAS drive only support Primary Channel
Fan Speed Switch (SW1)
LOW - 2400 rpm HIGH- 3000 rpm
HDD Activity LED Switch (SW2)
ON - Show Disk Activity OFF - Show Green Power LED (If Drive(s)
is in the tray)
Default Internal Storage Unit Temperature set to 60°C, you can change the jumper to either 55°C, 60° C or 65°C Fan Status LED, Set via FR, F+, FG Temperature Status LED, set via TR, T+, TG Hard Drive Activity LED set via +HDD, 3; +HDD, 2; +HDD, 1
FAN1
- Fan pull air from the front of the Storage Bays
- Fan Size: 70 x 70 mm Fan
- Fan Status (F01) - will show Red LED if fan Fails
LED Fan Status (F01)
Normal - Green LED Fan Failure - Red LED
Power Connector (P01, P02)
Dual Power Connection for all 3 Bays
Note:
1) Two Power Connectors must be connected from the system power supply
2) Power load balance by all attached drives
D01P01
FAN1
FAN1
FAN1
L01
L03
L02
L01
L03
L04
L02
L01
L03 L04 L04L02L01
B01
B03
T01
F01
T01
F01
F01
D05 D04 D03 D02 D01
T01
B02
B01
B03
B04
B02
B01
B01 B02 B03 B04 B05
SW1
SW1
D01
D02
D03
D01
D02
D03
D04
P01
P01
P02
P02
P02
SW2
P01
SW1
SW2
SW1
SW2
Loading...