Job __________________________
Item No ______________________
PowerMax200x2TM Gas Booster Heater
` Model: PM200x2N
Temperature Rise
Gallons per Minute
Gallons per Hour
FEATURES AND BENEFITS
• Single point water, gas and electrical connections
• Factory-provided pressure and temperature relief
valve
• Can be installed in a remote location up to 150
feet from the scullery
• All waterways constructed of stainless steel,
copper and brass for corrosion protection and
clean operation
• Simple, easy maintenance through front panel
• All stainless steel cabinet and frame
• Instant 1850F water provided consistently to
dishwasher rinse cycle
• Welded stainless steel accumulator (limited
lifetime warranty) maintains rinse water at 1850F
• Woven Fiber Power Burners
Printed in USA R06/15
400 Rise 500 Rise 600 Rise 700 Rise 1400 Rise
17.4 14 11 10 5
1040 840 660 600 300
• Radial solid copper fin-tube heat exchanger for
3600 heat transfer
• Cleanable intake air filters
• Burners activated by water flow & temperature
• Advanced microprocessor controls
• Natural Gas or Liquid Propane (199,900
BTUH per Burner)
• Can provide 100% of hot water requirement for
many restaurants
• Stainless Steel Seismic Legs are standard
ACCESSORIES AND OPTIONS
(available at additional cost)
□ EZ-Vent Kit for Venting through dishwasher
ventilation system
□ Factory Authorized StartUp
□ Re-circulating Kit required if booster is located
more than 5 ft from dishwasher rinse valve
□ ¾;1” for remote installations and/or single tank hot
water coil tank heat (also requires a CT-1 module)
□ 1-¼” for long distance remote installations and/or 2
tank hot water coil tank heat and/or 2 dishwasher
rinse service (also requires CT-2 module)
□ Water Hammer Arrester
□ Water Pressure Gauge
□ Water Temperature Gauge
□ Water Pressure/Temperature Gauge
□ High Pressure water pressure reducing valve
(needed if water supply pressure exceeds
80psi)
□ Low Pressure water pressure reducing valve
(for dishwasher rinse; installed after booster &
before D/W rinse)
□ Auxiliary PowerVent required for extended
flue lengths. Call factory
□ EZ Install Kit
□ Expansion Tank
TM
or PM200x2L
TM
PowerMax200x2TM – High Output Gas Booster Heater
Model: PM200x2NTM or PM200x2L
TM
Model Number
PM200x2
Natural Gas
Pressure
WC @ Inlet
Min M ax Min Max Nat LP Min Max
7” 10.5” 10” 14”
Temperature Rise 40oF 50oF 60oF 70oF 140oF
Gallons Per Minute 17.4 14 11 10 5
Gallons Per Hour 1040 840 660 600 300
*Contact factory if booster will be supplying dishwasher fill valves or tank heat.
BtuH per burner
Natural or Propane
TM
WC @ Inlet
2 @ 199,900
LP Gas
Pressure
Manifold
Pressure
WC
2.75”
-
3.5”
Gas
Connection
6.5”
-
8”
2ea-3/4"
NPT
Water
Pressure
(Flow)
40
80
psi
psi
Water
Supply
1 ¼" cu
Dishwasher Rinse
Re-circulating
3/4", 1" or 1 ¼” NPT *
Required if outlet is
more than 5 feet from
rinse valve of
dishwasher
Electrical
Connection
120V 1ph
12.4 amps
Loop
Gas Pressure
Regulators
Two Supplied 875 lbs
Clearance From
Combustible
Surface
Side Top Rear
6” L
1” R
1”
6”**
Shipping
Weight
Vent Per
Local Code
Auxiliary
Power Vent
Required for
extended flue
lengths Call
factory
**1” from back of exhaust vent
Note: May be vented through the dishwasher canopy or pant-leg exhaust system per 1991
Uniform Mechanical Code Sec 916. & 917. Check with local authority