Job __________________________
Item No ______________________
PowerMax125TM Gas Booster Heater
` Model: PM125N
Temperature Rise
Gallons per Minute
Gallons per Hour
FEATURES AND BENEFITS
• Single point water, gas and electrical connections
• Factory-provided pressure and temperature relief
valve
• Space saving design installs below dishtables
• Can be installed in a remote location up to 150
feet from the scullery
• All waterways constructed of stainless steel,
copper and brass for corrosion protection and
clean operation
• Simple, easy maintenance through front panel
• All stainless steel cabinet and frame
• Instant 1850F water provided consistently to
dishwasher rinse cycle
• Welded stainless steel accumulator (limited
lifetime warranty) maintains rinse water at 1850F
• Woven Ceramic Fiber Infrared Power Burner
Printed in USA R6/05
400 Rise 500 Rise 600 Rise 700 Rise 1400 Rise
5.40 4.38 3.44 3.10
325 262 206 188
7.5 gpm for 15 sec.
out of every 75 sec.
• Radial solid copper fin-tube heat exchanger for
3600 heat transfer
• Burners activated by water flow & temperature
• Advanced microprocessor controls
• Natural Gas or Liquid Propane 125,000 BTUH
ACCESSORIES AND OPTIONS
(available at extra cost)
□ EZ-Vent Kit for Venting through dishwasher
ventilation system
□ Factory Authorized StartUp-(highly
recommended)
□ Re-circulating kit
□ ¾;1” for remote installations and/or single tank hot
water coil tank heat (also requires a CT-1 module)
□ 1-¼” for long distance remote installations and/or 2
tank hot water coil tank heat and/or 2 dishwasher
rinse service (also requires CT-2 module)
□ Wall Mount Kit
□ Water Hammer Arrester
□ Water Pressure Gauge
□ Water Pressure/Temperature Gauge
□ Water pressure reducing valve (if water supply
pressure exceeds 80psi)
□ Low Pressure water pressure reducing valve
(for dishwasher rinse)
□ Auxiliary PowerVent required for extended
flue lengths. Call factory
□ EZ Install Kit
□ Seismic Legs
TM
or PM125L
TM
PowerMax125TM – High Output Gas Booster Heater
Model: PM125NTM or PM125L
Model Number
PM125
Natural Gas
Pressure
WC @ Inlet
Min Max Min Max Nat LP Min Max
7” 10.5” 10” 14” 3.5” 7.5”
Gallons Per Minute 5.40 4.38 3.44 3.10
*Contact factory if booster will be supplying dishwasher fill valves or tank heat.
TM
Temperature Rise 40oF 50oF 60oF 70oF 140oF
Gallons Per Hour 325 262 206 188
BtuH per burner
Natural or Propane
125,000 3/4" NPT 1" NPT
LP Gas
Pressure
WC @ Inlet
Manifold
Pressure
WC
**1” from back of exhaust vent
Note: May be vented through the dishwasher canopy or pant-leg exhaust system per 1991
Uniform Mechanical Code Sec 916. & 917. Check with local authority
Gas
Connection
Water
Pressure
(Flow)
40
psi
80
psi
Water
Supply
Dishwasher Rinse
Re-circulating
3/4" or 1" NPT*
Required if outlet is
more than 5 feet from
rinse valve of
dishwasher
Electrical
Connection
120V 1ph 6.2
amps
Loop
TM
Gas Pressure
Regulators
One each
Supplied
Clearance From
Combustible
Surface
Side Top Rear
6” L
1” R
1”
6”**
Shipping
Weight
Vent Per
Local Code
Auxiliary
Power Vent
Required for
extended flue
lengths Call
factory
7.5 gpm for
15 sec. out of
every 75 sec.
lbs
Printed in USA R6/05