Valor Retrofire RF24JB, Retrofire RA24JBNK, Retrofire RA24JBPK Installation & Owner's Manual

INSTALLATION & OWNER’S MANUAL
Retro re
Gas Conversion Kits RA24JBNK / RA24JBPK
Use with Valor Retrofi re Heater Models RF24JB ONLY
This appliance is certifi ed for use from 0-4500ft. For altitudes above 4500ft see local codes.
Kit Contents
• 1 Pilot injector (see chart below)
• 1 Burner
• 1 Main burner injector (see chart below)
• 1 Minimum rate by-pass screw (see chart below)
• 1 Set of air shutters
Tools Required
• Wrenches, to disconnect gas line
• Phillips (+) screwdriver, to remove burner module
• Small jewelers size fl at blade screwdriver, to set pressure
• Small fl at blade screwdriver, to release pressure tap on valve
• Needle Nose Pliers, to remove by-pass screw
• Hex Allen wrench, 4 mm or 5/32”, to remove pilot injector
• Special 2-pin screwdriver tip, supplied with kit, to remove valve cover
• Manometer, to set pressure
Specifi cations
WARNING
This conversion kit shall be installed by a qualifi ed service agency in accordance with the manufacturer’s instructions and all appli­cable codes and requirements of the authority having jurisdiction. If the information in these instructions is not followed exactly, a fi re, ex­plosion or production of carbon monoxide may result causing property damage, personal in­jury or loss of life. The qualifi ed service agency is responsible for the proper installation of this kit. The installation is not proper and complete until the operation of the converted appliance is checked as specifi ed in the manufacturer’s instructions supplied with the kit.
Use this manual in conjunction with the instal­lation manual supplied with the appliance.
Natural Gas Burner: Has two interlaced rows of slots
Fireplace Models RF24JBN RF24JBP
Gas Natural Propane Altitude (Ft) 0–4,500 Feet Input Max. (Btu/h) 20,000 18,000 Input Min. (Btu/h) 12,500 12,500 Manifold pressure (in w.c.) 3.2 9.5 Min. Supply pressure
(in w.c.) Max. Supply pressure
(in w.c.) Main Burner Injector 82-580 92-200 Pilot Injector 35 27 By-Pass Screw 185 125
4006630-01
© 2018 Miles Industries Ltd. All rights reserved.
5.0 11.0
10.0 14.0
Propane Gas Burner: marked “LPG” Has single row of slots and two rows of small holes
Conversion Procedure
1. If the fi replace is already installed, remove window
cover with barrier screen, window, and fuel bed.
2. Disconnect the gas inlet pipe from the inlet elbow
fi tting on the valve.
3. Remove the rear log support (4 screws).
4. Remove the burner module (4 screws).
7. Detach the two burner support brackets from the burner by removing two nuts, using a 5/16” (8 mm) wrench.
8. Replace the main burner with the burner assembly supplied with the conversion kit and reassemble the module.
9. Accessing the pilot assembly from the underside of the module, disconnect the pilot pipe, using a 7/16” (11 mm) wrench.
10. Remove the pilot injector. Replace with the appropriate gas injector.
Note - The pilot injector should be slipped onto the end of the pipe from the side. The pilot pipe, with injector attached, should be inserted into the assembly.
5. Disconnect the burner elbow injector from the pipe, using a 11/16” (17 mm) wrench.
6. Remove the 6 screws (2 underside of bracket) securing the burner brackets to the burner tray.
11. Remove and replace the minimum rate by-pass screw from the valve with the appropriately labelled by-pass screw—see Speci cations table on page
1. The screw has a rubber o-ring holding it into the valve body and may require prying out or removing the screw with needle nose pliers.
RF24BV or RF24XB
Fixing screws
Burner fixing nuts
Fixing screws underside of brackets
2