General safety considerations
Warning! Ifthisdeviceisusedagainstmanufacturer’sinstructions,usersafetymaybe compromised.
Warranty
For standard warranty terms and conditions, see www.vaisala.com/warranty.
Please observe that any such warranty may not be valid in case of damage due to normalwearandtear,exceptionaloperatingconditions,negligenthandlingorinstallation, orunauthorizedmodifications. PleaseseetheapplicablesupplycontractorConditions of Sale for details of the warranty for each product.
Technical support
Contact Vaisala technical support at helpdesk@vaisala.com. Provide at least the following supporting information:
•Product name, model, and serial number
•Name and location of the installation site
•Nameandcontactinformationofatechnicalpersonwhocanprovidefurtherinformation of the problem
For more information, see www.vaisala.com/support.
Document/Revision No. IM-EN-CI/2.00 |
Effective: September 2, 2019 |
Disposal
When wishing to dispose of an obsolete instrument or any parts of an instrument, please observe local and national regulations and requirements for the disposal of electrical and electronic equipment.
Symbols and terms used in this manual:
This indicates a warning. It provides safety precaution information needed to avoid injury while operating the refractometer system.
Thisindicatesthatsomethingis importantfortheoperationoftherefractometer system.
Note. Notes contain additional information and hints.
Compact user interface instruction manual
Table of contents
1 |
Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . |
1 |
|
2 |
Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . |
2 |
|
|
2.1 |
Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . |
6 |
|
2.1.1 |
Refractometer cable connection . . . . . . . . . . . . . . . . . . . . . . . . . . . |
7 |
|
2.1.2 |
Ethernet cable connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . |
7 |
3 |
Use . |
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . |
8 |
|
3.1 |
Refractometer connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . |
9 |
|
3.2 |
Activating and removing apps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . |
9 |
|
3.3 |
Configuring mA output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . |
13 |
|
3.4 |
Managing users . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . |
15 |
|
3.5 |
Ethernet connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . |
15 |
4 |
Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . |
17 |
|
|
4.1 |
Battery replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . |
17 |
5 |
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . |
20 |
|
|
5.1 |
Connector specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . |
22 |
A EU declaration of conformity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . |
25 |
||
B |
Software licence . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . |
27 |
Document/Revision No. IM-EN-CI/2.00 |
Effective: September 2, 2019 |
1 Description |
1 |
1 Description
The Compact user interface CI is a compact, light-weight display for monitoring and operating a Vaisala K-PATENTS® refractometer. It is ideal for applications where prism wash and additional inputs/outputs are not needed. CI is is operated by the touchscreendisplay. Itismainlyintendedforcontrolroomenvironment. Thereisaprotective cover available for industrial environment. CI has IP66 rating. An epoxy coated version of the CI is recommended for field installations.
Figure 1.1 Compact user interface CI
© Copyright Vaisala 2019. All rights reserved.
2 |
Compact user interface instruction manual |
2 Mounting
TheCompactuserinterfaceCIcanbemountedonawallwithawallmountingadapter or on a VESA 200x100 wall mounting arm, or on a table with a table stand. It also has a panel mounting option. The mounting location should be easily accessible.
Figure 2.1 Table stand
If the Compact user interface is installed in an industrial environment instead of a control room, a protective display shield is recommended. To mount the display shield, first screw two M5x 12 DIN912 A2 screws in upper two holes of the CI frame. Then install the hinges and shield to lower M5 holes with M5x12 ISO 14581 TX A2 screws.
Document/Revision No. IM-EN-CI/2.00 |
Effective: September 2, 2019 |
2 Mounting |
3 |
Figure 2.2 VESA wall mounting adapter
© Copyright Vaisala 2019. All rights reserved.
4 |
Compact user interface instruction manual |
296mm
152mm
275mm
226mm 142mm 195mm |
Dia. 5.2 mm |
Panel mounting dimensions.
Figure 2.3 Panel mounting option
Document/Revision No. IM-EN-CI/2.00 |
Effective: September 2, 2019 |
2 Mounting |
5 |
CI-004
Figure 2.4 Display shield installation
1
|
|
2 |
1 |
Slide cover upwards to unslot |
|
upper screw. |
|
|
2 |
Then cover is free to swing forwards |
CI-005 |
to max. rotation of 180°. |
|
Figure 2.5 Opening the display shield
© Copyright Vaisala 2019. All rights reserved.
<![endif]>00./2CI-EN-IM .No Document/Revision
<![if ! IE]><![endif]>2019 2, September Effective:
Refractometer with CI
<![if ! IE]> <![endif]>Figure |
|
PR-43 |
|
|
REFRACTOMETER |
|
|
|
|
M-12-8 pin, A code, M |
|
|
|
Unclassified area |
|
<![if ! IE]> <![endif]>6.2 |
|
PR-8430-____ |
|
|
F |
|
|
<![if ! IE]> <![endif]>CI |
Platform 4 cable |
|
|
|
M12-8 pin, A-code, F+M |
|
|
<![if ! IE]> <![endif]>connections |
|
|
|
|
Ethernet, mA, 24V |
|
|
|
|
max. 90m (295ft) |
M |
Compact User Interface, CI
1 x M12-4 pin, D-code, F (External Ethernet) 1 x M12-8 pin, A-code, F (System)
1 x M12-4 pin, A-code, M (24VDC, mA)
|
PR-8440-___ |
|
|
Ethernet cable for interfaces |
|
|
M12-4 pin, D-code, M+M |
|
|
Ethernet |
|
M |
max. 90m (295ft) |
M |
<![endif]>6
<![if ! IE]><![endif]>Connections 1.2
OR
|
PR-8330-___ |
|
|
Ethernet cable for interfaces |
|
|
M12-4 pin, D-code, M+RJ45 |
<![if ! IE]> <![endif]>userCompact |
|
Ethernet |
|
M |
max. 90m (295ft) |
|
|
PR-8350-010 |
<![if ! IE]> <![endif]>interface |
|
Power-mA cable M12 |
|
|
M12- 4 pin, A-code, F |
|
|
mA, 24V |
|
F |
10m (33ft) |
|
|
|
<![if ! IE]> <![endif]>manual instruction |