Vaisala Air Quality Monitoring System AQM60
Benefits
Site-specific air quality
monitoring
Air quality, weather and trac
data collected at one site
Safer traveling environment for
motorists
Provides data for mitigation
and control of pollutant levels
Alert the public about poor air
quality
Cost-eective
Features
Configure the system with up
to six sensors to meet your needs
Optional noise sensor
Rapid real-time data sampling
(2-minute)
Overview
Air pollutants can be harmful to public health and the environment, especially near roadways where vehicles emit gases continually in a localized area. Monitoring air quality data near roadways can assist with pollution mapping and control; detecting emissions from trafc ow, in tunnels, and near construction projects; environmental impact assessments, urban land use planning and community health programs (alerting the public about poor air quality). The Vaisala Air Quality Monitoring System AQM60 is a complete air quality monitoring system designed to measure a wide range of air quality parameters in a cost-effective, compact package.
The Vaisala Air Quality Monitoring System AQM60 system measures many of the pollutants considered harmful by the EPA (Environmental Protection Agency) including: Nitrogen Dioxide (NO2); Ozone (O3); Carbon Monoxide (CO); Carbon Dioxide (CO2); and Particulate Matter (PM
and PM10). The Vaisala Air
2.5
Quality Monitoring System AQM60 integrates with RWIS (Road Weather Information System), advisory radio systems, and ITS software platforms to provide weather, trafc and air quality data on one system. This allows customers to not only mitigate and control pollutant levels, but also save costs by combining their weather and trafc monitoring with the air quality system.
Large data storage capacity
(>15 years)
Data available in Vaisala
software
Modular design enables easy
maintenance
Remote diagnostic capabilities
Weatherproof and compact
enclosures
Technical data
Sensors (most common)
NO2; O3; CO; CO2; VOC; PM
and PM
2.5
Other Sensor Options
Noise and SO
Environmental Operating Range
-20 °C to 60 °C (-4 °F to 140 °F)
with appropriate Thermal Management System (TMS)*
10 to 90 %RH (non condensing)
Power Requirements
12 VDC (power subject to configuration)
AC power module 100 - 240 VAC
Maintenance Checks Routine
3, 6 or 12 months (site dependent)
Approvals
Electrical Safety and Conformity: CE; UL E215312 Gas Sensors: EN50082-1:1997; EN50081-1:1992; Part 15 FCC Rules; IPCA 610D Class 2 Particle Monitor: Class 1 laser; IEC 60825-1:1998
Environmental Operating Range
-40 °C to 60 °C (-4 °F to 140 °F)
with appropriate Thermal Management System (TMS)*
10 to 90 %RH (non condensing)
Applications
10
2
Urban and remote roadways
Trac flow control
Identification of air quality trouble spots
Tunnel monitoring
Airports (noise detection can be included)
Before /after road construction or mitigation
strategies
Long term air quality trend analysis
Short term environmental impact assessments
Local community exposures: residential, schools,
pedestrians, shopping centers
Sensor Modules**
GAS RANGE ACCURACY
Nitrogen Dioxide (NO2) 0 - 0.2 ppm <± 0.010 ppm Ozone (O3) 0 - 0.15 ppm <± 0.005 ppm Carbon Monoxide (CO) 0 - 25 ppm <± 1 ppm Carbon Dioxide (CO2) 0 - 2000 ppm < 40 ppm + 3 % Volatile Organic Compounds (VOC) Particulate Matter (PM and PM10)
0 - 25 ppm <± 10 %
0 - 2000 µg/m38 % of NIOSH 0600
2.5
For more information, visit www.vaisala.com or contact us at sales@vaisala.com
* TMS is customized for the sensor configuration and the environmental conditions at each location. ** Other sensor modules available upon request.
Ref. B211062EN-A ©Vaisala 2010
This material is subject to copyright protection, with all copyrights retained by Vaisala and its individual partners. All rights reserved. Any logos and/or product names are trademarks of Vaisala or its individual partners. The reproduction, transfer, distribution or storage of information contained in this brochure in any form without the prior written consent of Vaisala is strictly prohibited. All specifications — technical included — are subject to change without notice.