Technical specification
9
System reference
Outdoor units
VA6 - 050 MXNHO VA6 - 085 MXNHO VA6 - 105 MXNHO
Nominal cooling capacity
1
kW
(Min-max) kW
5.55 8.20 10.27
1.80-6.3 1.5-10.25 1.5-11.0
Nominal heating capacity
1
kW
(Min-max) kW
6.65 9.86 11.11
1.8-7.5 1.8-11.5 1.8-11.5
Nominal power input cooling/heating
1
kW 1.72/1.76 2.47/2.69 3.27/3.14
Operating current cooling/heating A 8.60/9.34 12.30/11.90 16.37/14.00
EER/COP 3.23/3.78 3.31/3.67 3.14/3.53
Nominal energy label cooling/heating
1
A/A A/A B/B
Compressor type Inverter DC twin rotary Inverter DC twin rotary Inverter DC twin rotary
Max. power input kW 2.30 3.80 4.00
Air flow volume high/med/low m3/h 3200/2300/1600 4000/3200/2300 4300/3500/2600
Sound pressure level (max)
3
dB(A) 53 53 55
Dimensions HxLxD mm 928x288x680 840x1068x340 840x1068x340
Net weight Kg 54 74 75
Installation
Power supply V/ph/Hz 230/1/50 230/1/50 230/1/50
Maximum operating current A 10.20 16.60 18.10
Power to: Outdoor + indoor Outdoor + indoor Outdoor + indoor
Interconnecting wiring 2 core sheathed data 2 core sheathed data 2 core sheathed data
Recommended fuse rating (type D) A 16 20 20
Pipe connection liq/gas in 1/4-3/8 1/4-3/8 1/4-3/8
Max. piping length (longest single pipe circuit) m 25 25 25
Max. total pipe length of all circuits added together m 45 60 60
Max. height IU under OU m 10 10 10
Max. height OU under IU m 15 15 15
Chargless length (total for all circuits) m 30 40 40
Additional charge per meter gr 20 20 20
System reference
Indoor units
VA10-020 VA10-025 VA10-035 VA6-035 VA6-050 VA6-035 VA6-050
MXNHI MXNHI MXNHI MXNHKI MXNHKI MXNHDI MXNHDI
Cooling capacity kW 2.00 2.50 3.50 3.24 5.03 3.61 5.15
Heating capacity kW 2.30 2.90 3.80 3.45 5.47 3.85 5.65
Net dimensions
HxLxD mm
285x760x182 285x760x182 285x760x182 260x570x570 260x580x580 290x610x550 290x1090x500
Power supply V/Ph/Hz 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50
Air flow volume
high/med/low m
3
/h
450/400/370 500/450/400 600/550/500 63 0/530/450 670/600/550
[550/]500/
450/400
[1270/]1160/
1020/900
Sound pressure
level min/max
2
dB(A)
32/43 32/43 32/43 37/44 37/44 35/40 38/44
Pipe connection
liq/gas in
1/4-3/8 1/4-3/8 1/4-3/8 1/4-3/8 1/4-1/2* 1/4-3/8 1/4-1/2*
Net weight Kg 8.6 8.6 8.6 17.0 19.0 14.0 25.0
Recommended MCB
size (type D) A
10.0 10.0 10.0 10.0 10.0 10.0 10.0
1
Actual ratings dependent on system components.
2
Sound pressure level indoor unit: directivity 3 dB(A) distance 2.2m.
3
Sound pressure level external unit: directivity 3 dB(A) distance 1.8m.
Nominal cooling capacities based on indoor temperatures of 27ºCDB/19ºCWB -- outdoor temperatures 35ºCDB/24ºCWB
* adaptor supplied.