Vaillant multi twin split range, V-multi range Overview

climaVAIR air conditioning
multi systems
multi twin split range V-multi range
climaVAIR
multi split systems
Take air conditioning for example. In an enclosed environment, air conditioning can improve the ambient by controlling the temperature and humidity. As well as cooling the air, our heat pump systems can efficiently heat the room during colder periods. This means you can enjoy a climate controlled environment all year round. Advanced filter solutions also bring good news for allergy sufferers with the air conditioning system cleaning the air as it circulates in the room. And, due to it’s high efficiency in heating mode, it’s more environmentally friendly than a conventional heating system.
When it comes to creating the ideal living environment, Vaillant has it all under control. For more than 130 years, we have been setting the standards in the heating market, developing products that have revolutionised the industry. Today we are still Europe’s No. 1 boiler manufacturer with an enviable reputation for performance, efficiency, quality and reliability. But staying on top requires constant innovation. So we continually invest in developing new energy efficient technologies for even better solutions – all designed to create the perfect climate at home and at work.
2 |3
For over 10 years, Vaillant air conditioning systems have been the preferred choice for discerning domestic and commercial customers across mainland Europe. Now available in the UK, they have been tried, tested and proven in a huge variety of applications – and because all Vaillant systems incorporate heat pump technology to heat as well as cool, our systems offer genuine year round climate control. Furthermore, each unit has plenty of built-in convenience features representing unbeatable value.
All climaVAIR air conditioning units have high efficiency ratings and utilize zero ozone depleting potential (ODP) refrigerants.
For more information contact:
Vaillant Air Conditioning sales
Vaillant Ltd., Unit D1, Lowfields Business Park, Elland, West Yorkshire HX5 9DG Telephone 01422 376070 Fax 01422 311986 E-mail airconditioning@vaillant.co.uk
Technical, design, commissioning and service support
Telephone 0870 8503071 Fax 01773 525946 E-mail aftersales@vaillant.co.uk
Training
Telephone 01634 292370 Fax 01634 292354 E-mail training@vaillant.co.uk
Vaillant Head Office
Vaillant Ltd.,Vaillant House, Trident Close, Rochester, Kent ME2 4EZ Telephone 01634 292300 E-mail info@vaillant.co.uk
Website
www.vaillant.co.uk
climaVAIR performance
wall mount multi twin split system
High wall inverter multi twin split systems
Vaillant’s climaVAIR performance multi heat pump range is ideal when more than one area requires air conditioning and there is limited room for the outdoor units. The range consists of 2 energy efficient inverter models of 5.0kW & 6kW. Each of these system consists of one outdoor unit which is connected to two individual indoor wall mounted units.
The multi twin split systems have all the features of the performance range such as DC inverter speed control compressors, high efficiency non-ozone depleting R410a refrigerant, three stage filtration, remote setting of horizontal and vertical louvres and simple to use multi-function infra red remote control as standard, which includes remote setting of: – Temperature and operating mode – Fan speed – Louvre position – Timer and sleep function – Air quality settings
climaVAIR performance high wall multi-split system models
Mono inverter units: A range of two models from 5.0kW to 6.0kW
Outdoor unit
Remote control
Indoor unit
4 |5
Dimensions and features
Indoor unit dimensions
Outdoor unit dimensions
All climaVAIR performance high wall twin units have the following features
4 Modes
Cooling, heating, fan and dry mode.
Auto operation
Automatic activation in the appropriate mode (COOL - HEAT - DRY), by adjusting its operation to the ambient temperature. The user can also remotely select the desired airflow.
Ionizer
Negative ion generator which as well as being beneficial for well-being and the environment, also neutralises odours, provides freshness and reduces contamination.
Infra-red remote control
All functions controlled by infra-red remote control.
Hot start function
Only starts the internal fan when the heating coil is hot to prevent cool air discharge.
Auto restart function
After power cut this function ensures the system restarts with the same settings (as those in force prior to power supply interruption).
Silent operation
Lowers the internal fan speed to provide reduced noise levels.
Turbo
Increases the air conditioning speed when faster room cooling/heating is required.
Horizontal air swing
Enables the air direction to be adjusted horizontally for improved distribution.
Vertical air swing
Enables the air direction to be adjusted vertically for improved distribution.
Sleep function
Function which adapts the ambient temperature during sleep.
24hr programmer
Programs the units so that they start or stop at user defined times.
Outdoor valve protector
Protects the valves on the outdoor unit from exposure to the elements.
Defrost
Prevents the outdoor unit from freezing in the winter months.
Anti-rust outdoor
Outdoor unit made of galvanised steel and anti-rust materials. Even resistant in environments with high saline content.
DC inverter technology
Technology which significant reduces energy and CO
2
output by matching compressor
speed to cooling/heating requirement.
R410a
Energy efficient zero ozone depleting potential (ODP) refrigerant.
Scroll compressor
Scroll compressor technology for higher efficiency.
Anti dust filter
Removes small particles of dust and debris from the circulated air.
Anti-germ
Filter with special coating to neutralise bacteria and germs.
Activated carbon filter
Filter with special coating to provide anti­odour and sterilisation of the circulated air to remove harmful smells and odours.
Model H L D Kg
V10-025 MNHI 285 760 185 8.6
V10-035 MNHI 285 760 185 8.6
Model H L D Kg
V10-050 M2NHO 915 699 325 42
V10-060 M2NHO 915 699 325 42
climaVAIR
performance V-Multi split system
V-Multi-split systems
Vaillant’s versatile climaVAIR V-Multi heat pump range is ideal when there is a need to cool or heat a number of rooms. Each outdoor unit can connect to up to four indoor units which can be a combination of wall mount, cassette or ducted type units.
The range consists of 3 energy efficient inverter outdoor units ranging of 5.0kW & 10.5kW.
Each of the indoor units has all the features of the mono performance range. Infra red remote control is standard for the wall mount and cassette units with the ducted unit having a wired remote controller.
Functions include remote setting of: – Temperature and operating mode – Fan speed – Louvres (wall and cassette only) – Timer and sleep function – Air quality settings (wall mount only)
climaVAIR V-Multi-split system models
Mono inverter units: A range of three outdoor units models from 5.0kW 10.5kW
- Three wall mounted units from 2.0 to 3.5kW
- Two cassette units of 3.5kW and 5.0kW
- Two ducted units of 3.5 and 5.0kW
Outdoor unit
Remote control Cassette unit
Dimensions and features
Indoor unit dimensions
Model H L D Kg
VA6-020 MXNHI 285 760 182 8.5
VA6-025 MXNHI 285 760 182 8.5
VA6-035 MXNHI 285 760 182 8.5
Model H L D Kg
VA6 – 035 MXNHKI 260 570 570 17
VA6 – 050 MXNHKI 260 580 580 17
Model H L D Kg
VA6 – 035 MXNHDI 290 610 550 14
VA6 – 050 MXNHDI 290 1090 500 25
Model H L D Kg
VA6 – 050 MXNHO 928 680 288 54
VA6 – 085 MXNHO 840 1068 340 74
VA6 – 105 MXNHO 840 1068 340 74
Outdoor unit dimensions
All climaVAIR V-Multi units have the following features
Auto restart function
After power cut this function ensures the system restarts with the same settings (as those in force prior to power supply interruption).
Silent operation
Lowers the internal fan speed to provide reduced noise levels.
Turbo
Increases the air conditioning speed when faster room cooling/heating is required.
Horizontal air swing
(Cassette and high wall only) Enables the air direction to be adjusted horizontally for improved distribution.
Vertical air swing
(High wall units only) Enables the air direction to be adjusted vertically for improved distribution.
Sleep function
Function which adapts the ambient temperature during sleep.
24hr programmer
Programs the units so that they start or stop at user defined times.
Outdoor valve protector
Protects the valves on the outdoor unit from exposure to the elements.
Energy class ‘A’
Many unit combinations achieve ‘A’ rated energy efficiency.
Defrost
Prevents the outdoor unit from freezing in the winter months.
Anti-rust outdoor
Outdoor unit made of galvanised steel and anti-rust materials. Even resistant in environments with high saline content.
DC inverter technology
Technology which provides energy saving in comparison to conventional on/off systems.
R410a
Energy efficient zero ozone depleting potential (ODP) refrigerant.
Twin rotary
Twin rotating cylinders provide improved efficiency and reduced vibration in comparison with single types.
4 Modes
Cooling, heating, fan and dry mode.
Auto operation
Automatic activation in the appropriate mode (COOL - HEAT - DRY), by adjusting its operation to the ambient temperature. The user can also select the desired airflow.
Ionizer (wall mount only)
Negative ion generator which as well as being beneficial for well-being and the environment, also neutralises odours, provides freshness and reduces contamination.
Infra-red remote control
All functions controlled by infra-red remote control.
Hot start function
Only starts the internal fan when the heating coil is hot to prevent cool air discharge.
Single phase supply
All climaVAIR multi units operate on a single phase supply.
LR
Technical specification
climaVAIR performance multi inverter heat pump
System reference V10-050 M2N V10-060 M2N
Cooling capacity kW 5.42 5.47
Min ~ max kW 1.25 - 6.00 1.3 - 6.1
Heating capacity kW 6.32 6.44
Min ~ max kW 1.62 - 6.8 1.72 - 6.96
Power input cooling/heating kW 1.63/1.63 1.64/1.77
Operating current cooling/heating A 7.5/8.8 7.8/7.4
EER/COP 3.33/3.87 3.33/3.64
Energy level class A/A A/A
Annual consumption
1
kWh 813 821
Indoor unit (1) V10-025 MNHI + V10-025 MNHI + Indoor unit (2) V10-025 MNHI V10-035 MNHI
Air flow volume (unit 1) low/med/high m3/h 500/440/380 500/440/380
Air flow volume (unit 2) low/med/high m3/h 500/440/380 500/440/380
Remote control Infra red Infra red
Sound pressure level (unit 1 - unit 2) min/max2dB(A) 26/38 - 26/38 26/38 - 28/40
Dimensions HxLxD (unit 1) mm 285x760x185 285x760x185
Dimensions HxLxD (unit 1) mm 285x760x185 285x760x185
Weight Kg 8.6 8.6
Outdoor unit V10-050 M2NHO V10-060 M2NHO
Air flow volume m3/h 2800 2800
Sound pressure level
3
dB(A) 52 52
Refrigerant R410a R410a
Refrigerant charge heat pump gr 1800 1800
Compressor type DC scroll DC scroll
Dimensions HxLxD mm 915x699x325 915x699x325
Weight Kg 42 42
Installation
Power supply V.Ph.Hz 230/1/50 230/1/50
Max operating current A 10.3 10.4
Recommended fuse size (Type D) A 16 16
Interconnecting cores (indoor to outdoor) 3 core + Earth (to each indoor) 3 core + Earth (to each indoor)
Supply to Outdoor Outdoor
Pipe connection liq/gas (Units 1&2) inches 1/4-3/8 1/4-3/8
Max. Piping length (each circuit) m 15 15
Max. height differential indoor to outdoor m 10 10
Chargeless length m 10 10
Additional charge per metre gr 20g 20g
1
Based on 500 hours operating at maximum load
2
Sound pressure level IU: directivity 3 dB(A) distance 2.2 m.
3
Sound pressure level OU: directivity 3 dB(A) distance 1.8 m.
4
Minimum operating temperature cooling/heating 18ºC/-7ºC
Nominal cooling capacities based on indoor temperatures of 27ºCDB/19ºCWB -- outdoor temperatures 35ºCDB/24ºCWB.
6 |7 |8
Technical specification
9
System reference
Outdoor units VA6 - 050 MXNHO VA6 - 085 MXNHO VA6 - 105 MXNHO
Nominal cooling capacity
1
kW
(Min-max) kW
5.55 8.20 10.27
1.80-6.3 1.5-10.25 1.5-11.0
Nominal heating capacity
1
kW
(Min-max) kW
6.65 9.86 11.11
1.8-7.5 1.8-11.5 1.8-11.5
Nominal power input cooling/heating
1
kW 1.72/1.76 2.47/2.69 3.27/3.14
Operating current cooling/heating A 8.60/9.34 12.30/11.90 16.37/14.00
EER/COP 3.23/3.78 3.31/3.67 3.14/3.53
Nominal energy label cooling/heating
1
A/A A/A B/B
Compressor type Inverter DC twin rotary Inverter DC twin rotary Inverter DC twin rotary
Max. power input kW 2.30 3.80 4.00
Air flow volume high/med/low m3/h 3200/2300/1600 4000/3200/2300 4300/3500/2600
Sound pressure level (max)
3
dB(A) 53 53 55
Dimensions HxLxD mm 928x288x680 840x1068x340 840x1068x340
Net weight Kg 54 74 75
Installation
Power supply V/ph/Hz 230/1/50 230/1/50 230/1/50
Maximum operating current A 10.20 16.60 18.10
Power to: Outdoor + indoor Outdoor + indoor Outdoor + indoor
Interconnecting wiring 2 core sheathed data 2 core sheathed data 2 core sheathed data
Recommended fuse rating (type D) A 16 20 20
Pipe connection liq/gas in 1/4-3/8 1/4-3/8 1/4-3/8
Max. piping length (longest single pipe circuit) m 25 25 25
Max. total pipe length of all circuits added together m 45 60 60
Max. height IU under OU m 10 10 10
Max. height OU under IU m 15 15 15
Chargless length (total for all circuits) m 30 40 40
Additional charge per meter gr 20 20 20
System reference
Indoor units VA10-020 VA10-025 VA10-035 VA6-035 VA6-050 VA6-035 VA6-050 MXNHI MXNHI MXNHI MXNHKI MXNHKI MXNHDI MXNHDI
Cooling capacity kW 2.00 2.50 3.50 3.24 5.03 3.61 5.15
Heating capacity kW 2.30 2.90 3.80 3.45 5.47 3.85 5.65
Net dimensions HxLxD mm
285x760x182 285x760x182 285x760x182 260x570x570 260x580x580 290x610x550 290x1090x500
Power supply V/Ph/Hz 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50
Air flow volume high/med/low m
3
/h
450/400/370 500/450/400 600/550/500 63 0/530/450 670/600/550
[550/]500/ 450/400
[1270/]1160/ 1020/900
Sound pressure level min/max
2
dB(A)
32/43 32/43 32/43 37/44 37/44 35/40 38/44
Pipe connection liq/gas in
1/4-3/8 1/4-3/8 1/4-3/8 1/4-3/8 1/4-1/2* 1/4-3/8 1/4-1/2*
Net weight Kg 8.6 8.6 8.6 17.0 19.0 14.0 25.0
Recommended MCB size (type D) A
10.0 10.0 10.0 10.0 10.0 10.0 10.0
1
Actual ratings dependent on system components.
2
Sound pressure level indoor unit: directivity 3 dB(A) distance 2.2m.
3
Sound pressure level external unit: directivity 3 dB(A) distance 1.8m. Nominal cooling capacities based on indoor temperatures of 27ºCDB/19ºCWB -- outdoor temperatures 35ºCDB/24ºCWB * adaptor supplied.
02.08 climaVAIR multi split range brochure.
Vaillant Ltd.
Vaillant House Medway City Estate Trident Close Rochester Kent ME2 4EZ Telephone 01634 292300 Fax 01634 290166 www.vaillant.co.uk info@vaillant.co.uk
Loading...