- Date 05/2015
System diagrams
Online training multiMATIC 700
No responsibility is taken for the correctness and completeness of this information

System diagram 1
System with boiler: DHW regulation by boiler (except in solar systems)
(System diagram = 1, VR 70 configuration = 3)
- Date 05/2015
No responsibility is taken for the correctness and completeness of this information
2

System diagram 2
System with boiler: DHW regulation by VRC 700
(System diagram = 2, VR 70 configuration = 1)
- Date 05/2015
No responsibility is taken for the correctness and completeness of this information
3

System diagram 6
3 kW hybrid system (alternative operation mode): DHW only by boiler
(System diagram = 6, no VR 70)
- Date 05/2015
No responsibility is taken for the correctness and completeness of this information
4

System diagram 7
3 kW hybrid system (parallel operation mode with 2 circuits / zones): DHW only by boiler
(System diagram = 7, VR 70 configuration = 1)
- Date 05/2015
No responsibility is taken for the correctness and completeness of this information
5

System diagram 8
Standard heat pump system, auxiliary heater requires pump of heat pump, monoenergy (DHW by heat
pump and auxiliary heater or simple hybrid system (DHW by boiler only)
(System diagram = 8, no VR 70)
- Date 05/2015
No responsibility is taken for the correctness and completeness of this information
6

System diagram 9
Simple hybrid system, auxiliary heater does not require pump of heat pump, DHW by boiler only
(System diagram = 9, VR 70 configuration = 5)
- Date 05/2015
No responsibility is taken for the correctness and completeness of this information
7

System diagram 10
Heat pump system with heat exchanger, auxiliary heater requires heat exchanger pump, monoenergy
(DHW only by heat pump) (System diagram = 10, no VR 70)
- Date 05/2015
No responsibility is taken for the correctness and completeness of this information
8

System diagram 11
Standard heat pump system with heat exchanger, auxiliary heater requires pump of heat pump, mono-
energy (DHW by heat pump and auxiliary heater) (System diagram = 11, no VR 70)
- Date 05/2015
No responsibility is taken for the correctness and completeness of this information
9

System diagram 12
Complete hybrid system, auxiliary heater does not require pump of heat pump (DHW by heat pump and
boiler) (System diagram = 12, VR 70 configuration = 5)
- Date 05/2015
No responsibility is taken for the correctness and completeness of this information
10

System diagram 13
Complete hybrid system with heat exchanger, auxiliary heater does not require pump of heat pump
(DHW by heat pump and boiler) (System diagram = 13, VR 70 configuration = 1)
- Date 05/2015
No responsibility is taken for the correctness and completeness of this information
11

Swimming pool circulation pump
CHP system circulation pump
Thermal discharge safety device
Domestic hot water cylinder
DHW cylinder with pipe heat exchanger
Mixer for increase in return flow
Thermostatic radiator valve
Diverter valve (inside unit)
Heat generator control system
Hot water charging controller
Diaphragm expansion vessel for drinking water
Safety group for drinking water connection
Outside temperature sensor/DCF receiver
Outside temperature sensor
Individual room control valve
Drinking water station (DWS)
Hot water charging sensor
Cylinder temp. sensor for DHW gener.
Heat pump brine filling unit
Filling and draining valve
Solar automatic air vent with lock
Legend for system diagrams
Item Description Item Description
1
2
2a
2b
2c
3
3a
4
5
5b
5c
6
- Date 05/2015
No responsibility is taken for the correctness and completeness of this information
7
8
9
10
12
13
13a
13b
13d
13e
13f
13g
13h
14
15
16
16a
17
18a
18b
19
20
21
22
24
-off relay 60
29
31
-functional cylinder 33a
34
36
42a
45
63
25
26a
26b
27
28
30
32
33
34a
35
37
38
39
40
42b
42c
43
48
49
50
51
52
53
53a
56
57
58
59
-return valve
12

Cylinder/solar temperature sensor/
Cylinder/solar temperature sensor/
Cylinder/solar temperature sensor/
Legend for system diagrams
Item Description
63a
64
65
66
67
67a
67b
68
69
70
71
- Date 05/2015
72
84
93
R1
R2
R3/R4
R5/R6
S1
S2
S3
S4
S5
S6
S7
-line vessel
-way mixer
-way mixer, cooling
-way mixer, passive cooling assembly
DJ-sensor
DJ-sensor
DJ-sensor
DJ-sensor
DJ-sensor
DJ-sensor
No responsibility is taken for the correctness and completeness of this information
13