8.2 Vaillant service ........................................................8
1 Notes on the documentation
The following information is intended to help you
throughout the entire documentation.
Further documents apply in combination with this installation manual.
We accept no liability for any damage caused by failure to observe these instructions.
Other applicable documents
Observe the individual operating and installation manuals of the various components of the plant when installing, commissioning and starting up.
Storage of the documents
Pass on this installation manual to the owner of the system in order for him/her to store it so that it is available
whenever it is required.
Symbols used
Please observe the safety instructions in this installation
manual for the installation of the appliance.
The symbols used in the manual are explained below:
Danger!
d
Immediate risk of serious injury or death
Danger!
e
Danger of death by electric shock!
Caution!
a
Potentially dangerous situation for the product
and environment.
Note!
h
Useful information and instructions
• Symbol for a necessary task
Applicability of the instructions
These installation instructions apply exclusively to units
with the following part numbers:
– 306782
– 0020076591
The part number of the unit can be found on the identification plate.
2 Description of the device
The VR 60 mixer module is used for system expansion
of the auroMATIC 620 or VRC 630 controllers and
Vaillant geoTHERM VW.. .../2 heat pumps.
Up to a maximum of six mixer modules can be connected. Two additional mixer circuits can be controlled per
VR 60 mixer module.
These mixer circuits can be programmed via the
auroMATIC 620 or VRC 630 controllers,
or the operating section of the Vaillant geoTHERM
VW.. .../2 heat pumps or, if required, via a separate
VR 80 or VR 90 remote control unit.
Each mixer circuit can, as required, be switched between:
– Heating circuit (radiator circuit, floor circuit, etc.)
– Fixed value control
– Return flow boost
– Hot water circuit (storage tank charging circuit, in ad-
dition to integrated hot water circuit).
The "Return flow boost" and "Hot water circuit" options
are not available with the Vaillant geoTHERM VW.. .../2
heat pumps.
With the telephone remote contact connection (floating
contact) on the auroMATIC 620 or VRC 630, the controller’s operating mode can be changed by telephone
by means of the teleSWITCH telephone remote switch.
2.1 Identification plate
The identification plate for the VR 60 mixer module is
located on the outside on the left hand side of the casing.
2.2 CE-mark/conformity
The CE label documents that the mixer module VR 60,
in connection with Vaillant boilers, fulfils the basic requirements of the following directives:
– Directive relating to electrical equipment designed for
use within certain voltage limits (2006/95/EWG)
– Directive relating to electromagnetic compatibility
(2004/108/EWG)
2.3 Intended use
The mixer module VR 60 is a state-of-the-art appliance
which has been constructed in accordance with recognised safety regulations. Nevertheless, there is still a
risk of death or serious injury to the user or others or of
damage to the device and other property in the event of
improper use or use for which it is not intended.
3 Safety instructions and regulations
The mixer module VR 60 must be installed by a qualified
engineer, who is responsible for adhering to the existing
standards and regulations.
We accept no liability for any damage caused by failure
to observe these instructions.
3.1 Safety instructions
Danger of death by electric shock!
e
Before carrying out work on the controller,
switch off the power supply and secure it
against being switched on again. Operating the
mains switch on the VR 60, auroMATIC 620 or
VRC 630 or the Vaillant geoTHERM VW.. .../2
heat pumps is not in itself sufficient to ensure
that all the terminals on the system are voltage free.
3.2 Regulations
All wiring must be in accordance with Building Regulations Part P and BS 7671 (IEE Wiring Regulations), and
must be carried out by a suitably qualified person.
Standard cable must be used for wiring.
Minimum cross-section of the cable:
– 230 V connecting cable
(pump or mixer connection cable) 1.5 mm
solid conductor
– Low-voltage leads
(sensor or Bus leads) 0.75 mm
Do not exceed following maximum wire lengths:
– Sensor connection 50 m
– Bus lead 300 m
If sensor and eBus leads run parallel to 230 V leads over
a distance greater than 10 m, they must be laid separately at a spacing of at least 25 mm.
230 V connection leads must be implemented with
2
1.5 mm
cable clamps supplied.
solid cable and fastened in the casing using the
2
2
The VR 60 mixer module is a system component in the
auroMATIC 620 or VRC 630 modular bus control systems for controlling hot water central heating installations with integrated hot water generation. The VR 60
mixer module can also be used as a system component
with the Vaillant geoTHERM VW.. .../2 heat pumps for
controlling hot water central heating installations. Any
other use or extended use is considered to be improper.
The manufacturer or supplier is not liable for any resulting damage. The owner alone bears the risk. Intended
use includes the observance of the installation manual.
Do not use free terminals of the appliances as support
terminals for other wiring.
The unit must be installed in a dry room.
The VR 60 mixer module should be mounted on the wall
in a suitable position close to the mixer circuits to be
controlled. Using the VR 60 mixer module, extension of
the heating installation by two mixer circuits is possible.
Up to a maximum of six mixer modules can be connected.
A unique bus address is set on the VR 60 mixer module
using the rotary switch. Setting the heating programmes
and all the required parameters is done via the
auroMATIC 620 or VRC 630 controller using the eBus or
the operating section of the Vaillant geoTHERM VW...2
heat pump. All heating circuit specific connections (sensors, pumps) are made directly on the mixer module via
ProE connectors.
4.1 Scope of delivery
Before starting the installation, check the scope of delivery for completeness and lack of damage.
Pos.AmountComponent
11Mixer module VR 60
22VR 10 standard sensor
31eBus lead, 3 m long
Table 4.1 Scope of delivery of the mixer module VR 60
4.2 Accessories
VR 90 remote control device
For the first eight heating circuits (HK 1 ... HK 8) its own
remote control unit can be connected. It permits the adjustment of the method of operation and the target
room temperature and takes account of the room temperature using the integrated room sensor.
It is also possible to adjust the parameters for the associated heating circuit (time programme, heating curve
etc.) and to select the special functions (party etc.). In
addition, it is possible to call up the displays of heating
circuit and maintenance and faults on the boiler. Communication with the heating control unit is via the eBus.
VR 80 remote control device
The VR 80 is a remote control unit for controlling a
heating circuit within a control system with an
auroMATIC 620 or VRC 630 controller or the Vaillant
geoTHERM VW.. .../2 heat pump. Regardless of whether
this remote control unit is used, all the settings for this
heating circuit are possible using the
auroMATIC 620 or VRC 630 controllers, or the operat-
ing section of the Vaillant geoTHERM VW.. .../2 heat
pump.
Fig. 4.1 Opening the casing
• Release the screw on the top of the casing.
• Tilt the casing cover forwards slightly and remove.
230 V~
230 V~
HKaHKa-PHKb-PAF
PE N L PE N LPE N LPE N Auf ZuPE N L AF 0
HKb
PE N Auf Zu
VFb
BUS
VFa
2 1
+ -
2 1
1
2
Fig. 4.2 Fitting the mixer module VR 60
• Mark the two fixing points at a suitable position in ac-
cordance with the fixing openings (1).
• Drill two holes for the suitable plugs and screw the
casing securely in position.
• The electrical installation is carried out as described in
Chapter 5.
• Insert the casing cover back into the hinges and hinge
the casing cover back up into position.
• Screw the casing cover in position in accordance with
Fig. 4.1.
4.3 Assembling VR 60 mixer module
The connection rails of the mixer module VR 60 are of
the type System ProETechnik. All onsite connections
must be made using these rails.
The electrical connection must be done by a suitably
qualified heating engineer who is responsible for complying with the existing standards and guidelines.
Danger of death by electric shock!
e
Before carrying out work on the controller,
switch off the power supply and secure it
against being switched on again.
Operating the mains switches on the VR 60
mixer module and on the auroMATIC 620 or
VRC 630 controllers or the Vaillant
geoTHERM VW.. .../2 heat pumps is not in itself
sufficient to ensure that all the terminals on
the system are voltage free.
If the casing of the VR 60 mixer module is closed, open
it as described in Chapter 4.3.
5.1 Connecting the mixer module to the building
• Wire up the VR 60 mixer module as shown in Fig. 5.1.
• Use the supplied eBus connection cable to incorporate
the mixer module VR 60 in the communication system. The eBUS can be branched at any part of the
system.
Electrical installation 5
In the entire system the mains infeed should be provided by the building works on one component.
Note!
h
Please make sure that the VR 60 mixer module
has a mains switch with which you can switch
off the internal electronics as well as all connected actuators (pumps, mixers) for the purposes of tests and maintenance.
Communication within the system takes place via an
eBus. To ensure flawless communication between all the
components it is necessary to allocate a unique address
to the individual mixer circuit. To do this set the value 4,
6, 8, 10, 12 or 14 on the address switch (Fig. 5.3 (3)) depending upon whether the VR 60 mixer module has already been integrated in the system.
Addresses 0 to 3 are used by the system circuits in the
auroMATIC 620 and VRC 630 controllers or the Vaillant
geoTHERM VW.. .../2 heat pump and are not therefore
Starting up the VR 60 mixer module is carried out in
conjunction with starting up the auroMATIC 620 or
VRC 630 controller or the Vaillant geoTHERM VW.. .../2
heat pump. To do this, proceed in accordance with the
instructions in the manual for the
auroMATIC 620 or VRC 630 controller or the Vaillant
geoTHERM VW.. .../2 heat pump.
7 Technical data
UnitVR 60
Operating voltage
Power consumption
Contact load of the output relays (max.)
Maximum total current
Maximum permissible ambient temperature °C40
Operating voltage sensorV5
Minimum cross-section of the sensor cables,
eBUS cables
Minimum cross-section of power cable
(rigid cable, NYM)
Dimensions of wall mounting base
Height
Width
Depth
Level of protection
Protection rating for regulator
Table 7.1 Technical data
V
VA
A
A
mm2
mm
mm
mm
mm
230
2
2
4
0.75
2
1.5
174
272
52
IP 20
II
VFb
AF
2 1
AF 0
Fig. 5.3 Setting the bus address
After connecting the electrical installation:
• Fix all cables with the accompanying cable clamps
(Fig. 4.2 (2)).
• Insert the casing cover back into the hinges and hinge
the casing cover back up into position.
• Screw the casing cover in position in accordance with
Fig. 4.1.
We only grant a Vaillant manufacturer's warranty if a
suitably qualified engineer has installed the system in
accordance with Vaillant instructions. The system
owner will be granted a warranty in accordance with the
Vaillant terms and conditions. All requests for work during the guarantee period must be made to Vaillant
Service Solutions (0870 6060 777).
8.2 Vaillant service
To ensure regular servicing, it is strongly recommended
that arrangements are made for a Maintenance
Agreement. Please contact Vaillant Service Solutions
(0870 6060 777) for further details.