Vaillant flexoTHERM VWF 5x, flexoTHERM VWF 19x/4 Operating Instructions Manual

For the operator
Operating instructions
flexoTHERM
VWF 5x - 19x/4
GB, IE
Operating instructions
Publisher/manufacturer
Berghauser Str. 40   D-42859 Remscheid Tel. +49 21 91 18‑0   Fax +49 21 91 18‑28 10 info@vaillant.de   www.vaillant.de
Contents
2 Operating instructions flexoTHERM 0020213396_00
Contents
1 Safety ............................................ 3
1.1 Action-related warnings ................. 3
1.2 General safety information............. 3
2 Notes on the documentation ...... 7
2.1 Observing other applicable
documents ..................................... 7
2.2 Storing documents......................... 7
2.3 Applicability of the instructions....... 7
3 System overview.......................... 7
3.1 Heat pump system design ............. 7
4 Product description..................... 8
4.1 CE label ......................................... 8
4.2 Safety devices ............................... 8
4.3 Serial number ................................ 9
4.4 Product design............................... 9
4.5 Opening the front flap .................... 9
4.6 Operator control panel................. 10
4.7 Basic display................................ 10
4.8 Operating concept ....................... 11
4.9 Menu display................................ 11
4.10 Operating levels........................... 12
5 Operating.................................... 12
5.1 Starting up the product ................ 12
5.2 Adjusting the target cylinder
temperature ................................. 12
5.3 Yield indicator .............................. 12
5.4 Displaying the Live Monitor.......... 12
5.5 Displaying the building circuit
pressure....................................... 12
5.6 Displaying the environment
circuit pressure ............................ 12
5.7 Reading the operating
statistics ....................................... 12
5.8 Setting the language.................... 13
6 Maintenance and care ............... 13
6.1 Checking and maintaining ........... 13
7 Troubleshooting ........................ 13
7.1 Fault message ............................. 13
8 Decommissioning...................... 14
8.1 Switching off the heat pump ........ 14
8.2 Permanently decommissioning
the product................................... 14
8.3 Recycling and disposal................ 14
9 Guarantee and customer
service ........................................ 14
9.1 Guarantee.................................... 14
9.2 Customer service......................... 15
Appendix ............................................... 16
A Overview of the operator's
operating level ........................... 16
Safety 1
0020213396_00 flexoTHERM Operating instructions 3
1 Safety
1.1 Action-related warnings Classification of action-re-
lated warnings
The action-related warnings are classified in accordance with the severity of the pos­sible danger using the following warning signs and signal words:
Warning symbols and signal words
Danger!
Imminent danger to life or risk of severe personal injury
Danger!
Risk of death from electric shock
Warning.
Risk of minor personal injury
Caution.
Risk of material or envir­onmental damage
1.2 General safety information
1.2.1 Intended use
There is a risk of injury or death to the user or others, or of dam­age to the product and other property in the event of im­proper use or use for which it is not intended.
The system is intended exclus­ively for domestic use.
The system is intended as a heat generator with cooling function for closed central heat­ing installations and for hot wa­ter generation. Operation of the pump outside the applic­ation limits results in the heat pump being switched off by the internal control and safety devices.
Cooling mode with radiator heating systems is not permit­ted since radiators do not have an adequate heat transfer sur­face area.
Intended use includes the fol­lowing:
– observance of the operating
instructions included for the product and any other system components
– compliance with all inspection
and maintenance conditions listed in the instructions.
This product can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervi­sion or instruction concerning use of the product in a safe way and understand the hazards in-
1 Safety
4 Operating instructions flexoTHERM 0020213396_00
volved. Children shall not play with the product. Cleaning and user maintenance shall not be made by children without super­vision. Children must not play with the product. Cleaning and user maintenance work must not be carried out by children unless they are supervised.
Any other use that is not spe­cified in these instructions, or use beyond that specified in this document shall be considered improper use. Any direct com­mercial or industrial use is also deemed to be improper.
Caution.
Improper use of any kind is prohibited.
1.2.2 Danger caused by improper operation
Improper operation may present a danger to you and others, and cause material damage.
Carefully read the enclosed
instructions and all other ap­plicable documents, particu­larly the "Safety" section and the warnings.
1.2.3 Risk of death due to explosive and flammable materials
Do not use or store explosive
or flammable materials (e.g.
petrol, paper, paint) in the in­stallation room of the product.
1.2.4 Risk of death due to changes to the product or the product environment
Never remove, bridge or
block the safety devices.
Do not tamper with any of the
safety devices.
Do not damage or remove
any seals on components. Only authorised competent persons or customer services may modify sealed compon­ents.
Do not make any changes to:
The product itselfThe product environmentThe brine fluid, air and elec-
tricity supply lines
– The drain line and expan-
sion relief valve for the heat source circuit
– The constructional condi-
tions that may affect the operational reliability of the product
1.2.5 Risk of injury due to chemical burns caused by brine fluid
The brine fluid ethylene glycol is harmful to health.
Avoid contact with the skin
and eyes.
Safety 1
0020213396_00 flexoTHERM Operating instructions 5
Always wear gloves and pro-
tective goggles.
Do not inhale or swallow.Observe the safety data sheet
that accompanies the brine fluid.
1.2.6 Preventing the risk of injury from freezing as a result of touching coolant
The product is supplied with an operational filling of R 410 A refrigerant. Escaping coolant may cause freezing if the exit point is touched.
If coolant escapes, do not
touch any components of the product.
Do not inhale any vapours or
gases that escape from the refrigerant circuit as a result of leaks.
Avoid skin or eye contact with
the coolant.
In the event of skin or eye
contact with the coolant, seek medical advice.
1.2.7 Risk of injury and material damage due to maintenance and repairs carried out incorrectly or not carried out at all
Never attempt to carry out
maintenance work or repairs on your product yourself.
Faults and damage should
be immediately rectified by a competent person.
Adhere to the maintenance
intervals specified.
1.2.8 Risk of material damage caused by frost
Ensure that the heating in-
stallation always remains in operation during freezing con­ditions and that all rooms are sufficiently heated.
If you cannot ensure the op-
eration, have a competent person drain the heating in­stallation.
1.2.9 Avoid environmental damage caused by escaping coolant
The product contains R 410 A refrigerant. The coolant must not be allowed to escape into the atmosphere. R410A is a fluorinated greenhouse gas covered by the Kyoto Protocol, with a GWP of 2088 (GWP = global warming potential). If this gas escapes into the atmo­sphere, its impact is 2088 times greater than the natural green­house gas CO2.
Before the product is disposed of, the coolant that is contained in it must be completely drained into a suitable vessel so that
1 Safety
6 Operating instructions flexoTHERM 0020213396_00
it can then be recycled or dis­posed of in accordance with regulations.
Ensure that only officially cer-
tified competent persons with appropriate protective equip­ment carry out maintenance work on the refrigerant circuit or access it.
Arrange for the refriger-
ant that is contained in the product to be recycled or disposed of by a certified competent person in accord­ance with the regulations.
Notes on the documentation 2
0020213396_00 flexoTHERM Operating instructions 7
2 Notes on the
documentation
2.1 Observing other applicable documents
You must observe all operating instruc-
tions enclosed with the system compon­ents.
2.2 Storing documents
Keep this manual and all other applic-
able documents safe for future use.
2.3 Applicability of the instructions
These instructions apply only to:
Applicability: Great Britain
OR Ireland
Product
VWF 57/4
VWF 87/4
VWF 117/4
VWF 157/4
VWF 197/4
Applicability: Great Britain
OR Ireland
Product
VWF 57/4 230 V
VWF 87/4 230 V
VWF 117/4 230 V
3 System overview
3.1 Heat pump system design
A
B
A
B
The heat pump system consists of the following components:
Heat pumpSystem controller (from VRC 700)Outside temperature sensor with DCF
receiver
System sensor, if requiredWith ground heat source: Ground
sensor
4 Product description
8 Operating instructions flexoTHERM 0020213396_00
– With air heat source: Air/brine col-
lector(s)
– With well water heat source: Groundwa-
ter module
There is an opportunity for active cooling to take place via circulation reversal for the heat sources air, ground and groundwater.
4 Product description
4.1 CE label
The CE label shows that the products comply with the basic requirements of the applicable directives as stated on the iden­tification plate.
The declaration of conformity can be viewed at the manufacturer's site.
4.2 Safety devices
4.2.1 Frost protection function
The frost protection function for the system is controlled via the system controller. If the system controller fails, the heat pump guarantees limited frost protection for the heating circuit.
4.2.2 Protection against low heating water pressure
This function continuously monitors the pressure of the heating water in order to prevent a possible loss of heating water.
4.2.3 Brine loss protection system
The brine loss protection system continu­ously monitors the fluid pressure in the environment circuit in order to prevent a possible shortage of fluid.
4.2.4 Freeze protection
This function prevents the evaporator from freezing when the heat source temperat­ure drops below a certain value.
The outlet temperature of the heat source is constantly measured. If the outlet tem­perature of the heat source falls below a certain value, the compressor temporarily switches off and displays a status mes­sage. If this fault occurs three times in a row, it is switched off and a fault message is displayed.
4.2.5 Pump- and valve-blocking protection system
This function prevents the pumps for heat­ing water and brine and all diverter valves from sticking. The pumps and the valves, which were out of operation for 23 hours, are switched on for 10 - 20 seconds, one after the other.
4.2.6 High-pressure pressure switch in the refrigeration circuit
The high-pressure pressure switch shuts down the heat pump if the pressure in the coolant circuit is too high. If the pressure in the heat pump's refrigeration circuit ex­ceeds the maximum pressure, the high­pressure pressure switch temporarily shuts down the heat pump. Following a waiting period, another attempt is made to start the heat pump. After three failed start at­tempts in succession, a fault message is displayed.
– Refrigeration circuit pressure max.: 4.60
MPa (g) (46.00 bar (g))
– Waiting period: 5 minutes (after the first
occurrence)
– Waiting period: 30 minutes
(after the second and every further oc­currence)
The fault counter is reset if both of the following conditions are met:
– Heat requirement without switching off
prematurely
– 60 minutes of uninterrupted operation
Product description 4
0020213396_00 flexoTHERM Operating instructions 9
4.2.7 Hot gas thermostat in the refrigeration circuit
The hot gas thermostat shuts down the heat pump if the temperature in the refri­geration circuit is too high. If the temperat­ure in the heat pump's refrigeration circuit exceeds the maximum temperature, the hot gas thermostat temporarily shuts down the heat pump. Following a waiting period, another attempt is made to start the heat pump. After three failed start attempts in succession, a fault message is displayed.
– Max. refrigeration circuit temperature:
130
– Waiting period: 5 minutes (after the first
occurrence)
– Waiting period: 30 minutes
(after the second and every further oc­currence)
The fault counter is reset if both of the following conditions are met:
– Heat requirement without switching off
prematurely
– 60 minutes of uninterrupted operation
4.2.8 Safety cut-out (SCO) in the heating circuit
If the temperature in the heating circuit of the internal auxiliary electric heating ex­ceeds the maximum temperature, the SCO shuts down the auxiliary electric heating as a securing measure. Following a waiting period, another attempt is made to start the auxiliary electric heating. A fault mes­sage is displayed that can only be reset by pressing the Reset button or by switching the heat pump off and on again.
– Max. heating circuit temperature: 85
4.3 Serial number
The serial number is located on a plate be­hind the front flap. The 7th to 16th digits of the serial number form the article number.
4.4 Product design
1
2
3
4
1
2
3
4
1 Front flap 2 Recessed
handle
3 Control elements
4 Plate showing
the serial num­ber
4.5 Opening the front flap
1. Take hold of the recessed handle in the front flap on the left- or right-hand side.
2. Pull the recessed handle.
4 Product description
10 Operating instructions flexoTHERM 0020213396_00
4.6 Operator control panel
50
d
kWh
reset
1
2
3
4
6
7
8
9
5
1 Displays the
daily environ­mental energy yield
2 Display of the
current as­signment of the right-hand selection button
3 Left- and right-
hand selection buttons
4
and but-
ton
5 Reset button 6 Access to the
menu for addi­tional information
7 Display of the
current configur­ation of the left­hand selection button
8 Displays the
symbols for the current operat­ing status of the heat pump
9 Display
4.7 Basic display
50
d
kWh
Sym­bol
Meaning Explanation
Compressor – Filled: Com-
pressor in op­eration
– Not filled:
Compressor not in operation
bar
Current filling pressure of the heating system The dashed lines show the permit­ted range.
– Permanently
on: Filling pressure in the permitted range.
– Flashing:
Filling pres­sure outside the permitted range.
Pumps – Left continu-
ously on: Brine pump in oper­ation
– Right con-
tinuously on: Heating pump in operation
Auxiliary electric heating
– Flashing: Aux-
iliary electric heating in op­eration
+ : Aux­iliary electric heating act­ive for heating mode
+ : Aux­iliary electric heating active for hot water handling mode
Green iQ mode – Product
equipped with energy-saving technology
Product description 4
0020213396_00 flexoTHERM Operating instructions 11
Sym­bol
Meaning Explanation
Heating mode – Continuously
on: Heating mode active
Cooling mode – Continuously
on: Cooling mode active (active or passive)
Hot water gener­ation
– Continuously
on: Hot water handling mode active
F. X X X
Fault in the product
– Appears in-
stead of the basic display, may be an ex­planatory plain text display
The basic display shows you the product's operating mode. If you press a selection button, the activated function is displayed in the display.
You can switch back to the basic display by:
Pressing to exit the selection levelsNot pressing any button for longer than
15 minutes.
If there is a fault message present, the ba­sic display switches to the fault message.
4.8 Operating concept
Op­erator control element
Function
– Displaying the environmental
energy yield in heating mode, hot water handling mode and cooling mode
– Cancelling a change to a set
value
– Going one selection level
higher
Op­erator control element
Function
Confirm settingGoing one selection level lower
+ at the same time
– Calling up the menu
or
– Reducing or increasing the set
value
– Scrolling through menu entries
The current function of the and selec­tion buttons is shown on the display.
Adjustable values are always displayed as flashing.
You must always confirm a change to a value. Only then is the new setting saved. You can press to cancel a procedure at any time.
4.9 Menu display
Xxxx Xxxxxxxxxxx
Xxxx Xxxxxxx
Xxxxxxxxxx
xxxxxx Xxxxxxx
1
4
3
2
1 Scroll bar 2 Current assign-
ment of the se-
lection buttons
3 Selection level
list entries
4 Selection level
You can find an overview of the menu structure in the appendix.
5 Operating
12 Operating instructions flexoTHERM 0020213396_00
4.10 Operating levels
The product has two operating levels.
The operating level for the operator shows the information and offers set-up options that do not require any special prior know­ledge.
The operating level for the competent per­son is protected by a code.
Overview of the operator's operating level (Page 16)
5 Operating
5.1 Starting up the product
Only start up the product once the cas-
ing has been completely closed.
5.2 Adjusting the target cylinder temperature
In order to achieve energy-efficient hot water generation predominantly from the energy extracted from the environment, the factory setting for the desired hot water temperature must be adjusted on the sys­tem controller.
To do this, adjust the cylinder set target
temperatures (Desired DHW circuit temperature) to between 50 and 55 °C,
for example.
Depending on the source of energy
obtained from the environment, hot water output temperatures of between 55 and 62 °C are reached.
5.3 Yield indicator
Displays the environmental energy yield as a cumulative value for a period of a day, a month and the total for the heating, hot water generation and cooling modes.
Displays the working figure for a period of a month and the total for the heating and hot water generation modes. The work­ing figure is the ratio of thermal energy generated to the operating current used.
Monthly values may vary considerably since, for example, in the summer only hot water generation is used. A large num­ber of factors influence this estimate, e.g. the type of heating installation (direct heat­ing mode = low flow temperature or indir­ect heating mode via buffer cylinder = high flow temperature). This figure may there­fore deviate by up to 20%.
The working figures only record the power consumption of internal components, not of external components such as external heating circuit pumps, valves, etc.
5.4 Displaying the Live Monitor
Menu Live Monitor
– You can use the Live Monitor to display
the current status of the product.
5.5 Displaying the building circuit pressure
Menu Live MonitorBuilding circuit pressure
– Current filling pressure of the heating
system
5.6 Displaying the environment circuit pressure
Menu Live MonitorEnvironment circuit pressure
– Current filling pressure in the environ-
ment circuit
5.7 Reading the operating statistics
Menu Information Heating op. hours
Menu Information DHW operating hours
Menu Information Cooling op. hours
Menu Information Total operating hours
Maintenance and care 6
0020213396_00 flexoTHERM Operating instructions 13
Operating hours for heating mode, hot water handling mode, cooling mode and the overall operation
5.8 Setting the language
Menu Basic settings Language
Setting the desired language
6 Maintenance and care
6.1 Checking and maintaining
6.1.1 Fulfilling requirements for the installation site
The installation site must be dry and frost­proof throughout.
Conditions: Outdoor air heat source
The air/brine collector is designed to be operated with outdoor air. The air intake and blow-off route of the outdoor unit must be kept clear at all times in order to guar­antee that the air can flow unhindered and as intended. Vegetation and, in winter, snowfall, must be cleared.
You are not permitted to make any sub­sequent structural alterations which may result in a reduced room volume or a change to the temperature at the installation site.
6.1.2 Caring for the product
Caution. Risk of material damage
caused by unsuitable clean­ing agents.
Do not use sprays, scouring
agents, detergents, solvents or cleaning agents that con­tain chlorine.
Clean the casing with a damp cloth and
a little solvent-free soap.
6.1.3 Checking the system pressure
Check the filling pressure of the heating
installation every day for a week after initial start-up and maintenance work, and then twice a year. – Filling pressure: 0.07 MPa
( 0.70 bar)
Filling pressure too low
Inform your competent person so
that he can add heating water and increase the filling pressure.
6.1.4 Checking the brine circuit's filling pressure
Check the brine circuit's filling pressure
at regular intervals. Read the brine cir­cuit's filling pressure in the heat pump's display. – Brine fluid operating pressure range:
0.07 … 0.20 MPa (0.70 … 2.00 bar)
7 Troubleshooting
7.1 Fault message
If several faults occur at the same time, the display shows the corresponding fault messages for two seconds each in alterna­tion.
F.714 Environment circuit: Pressure too low
If the filling pressure falls below the min­imum pressure, the heat pump will be switched off automatically.
Minimum brine fluid pressure:
0.05 MPa ( 0.50 bar)
Min. brine fluid operating pressure:
0.07 MPa ( 0.70 bar)
Inform your competent person so that
he can top up the brine fluid.
F.723 Building circuit: Pressure too low
If the filling pressure falls below the min­imum pressure, the heat pump will be switched off automatically.
8 Decommissioning
14 Operating instructions flexoTHERM 0020213396_00
Min. heating circuit pressure:
0.05 MPa ( 0.50 bar)
Min. heating circuit operating pressure:
0.07 MPa ( 0.70 bar)
Inform your competent person so that
he can top up the heating water.
8 Decommissioning
8.1 Switching off the heat pump
8.1.1 Temporarily decommissioning the product
Use the partition that is installed on-
site (e.g. fuses or power switches) to disconnect the product from the power supply.
8.1.2 Protecting the product against frost
Observe the installation site require-
ments for the product. (Page 13)
8.2 Permanently decommissioning the product
1. Have a competent person permanently
decommission the product.
2. Have the product disposed of by a
competent person.
8.3 Recycling and disposal
The competent person who installed
your product is responsible for the dis­posal of the packaging.
If the product is identified with this
symbol:
In this case, do not dispose of the
product with the household waste.
Instead, hand in the product to a collec-
tion centre for old electrical or electronic appliances.
If the product contains batteries that are marked with this symbol, these bat­teries may contain substances that are
hazardous to human health and the envir­onment.
In this case, dispose of the batteries at
a collection point for batteries.
8.3.1 Arranging disposal of the brine fluid
The product is filled with the brine fluid ethylene glycol, although when using ground as the heat source, aqueous solutions of propylene glycol may also be used as an alternative. Ethylene glycol is harmful to health.
Brine fluid must only be disposed of by
a qualified competent person.
8.3.2 Arranging disposal of coolant
The product is filled with R 410 A refriger­ant.
The coolant must not be allowed to escape into the atmosphere.
Coolant must only be disposed of by a
qualified competent person.
9 Guarantee and customer
service
9.1 Guarantee
Applicability: Great Britain
Vaillant provides a full parts and labour guarantee for this appliance for the dura­tion as shown on the enclosed registration card which must be fully completed and returned within 30 days of installation. All appliances must be installed by a suitably competent person fully conversant and in accordance with all current regulations applicable to the appliance type installa­tion. In the case of gas appliances the Gas Safety (Installation and Use) Regulations 1998, and the manufacturer’s instructions. In the UK competent persons approved at the time by the Health and Safety Execut­ive undertake the work in compliance with
Guarantee and customer service 9
0020213396_00 flexoTHERM Operating instructions 15
safe and satisfactory standards. Installers should also be fully conversant with and competent with all necessary electrical and building regulations that may apply to the installation.
In addition all unvented domestic hot water cylinders must be installed by a compet­ent person to the prevailing building regu­lations at the time of installation (G3). All appliances shall be fully commissioned in accordance with our installation manual and Benchmark commissioning check list (this will be included within the installa­tion manual). These must be signed and given to the user for safe keeping during the hand over process. Installers should also at this time advise the user of the an­nual servicing requirements and advise of appropriate service agreement.
Terms and conditions do apply to the guar­antee, details of which can be found on the registration card included with this appli­ance. In order to qualify for guarantee after one year the appliance must be serviced in accordance with our installation manual servicing instructions. The benchmark ser­vice history should be completed. Note ­all costs associated with this service are excluded from this guarantee.
Failure to install and commission this ap­pliance in compliance with the manufac­turer’s instructions will invalidate the guar­antee (this does not affect the customer’s statutory rights).
9.2 Customer service
Applicability: Great Britain
To ensure efficient and reliable operation of your boiler it is recommended that regu­lar servicing is carried out by your service provider:
Vaillant Applied System Sales
Vaillant Ltd. Nottingham Road Belper
Derbyshire DE56 1JT
United Kingdom
VaillantTraining: 845 601 88 85
E-mail: commercial@vaillant.co.uk
Commercial service assistance: 870 850 30 72 (Mon-Fri 8:30am – 5:30pm)
Technical advice: 844 693 31 33 (Mon-Fri 8:30am – 5:30pm, Sat 9:00am - 4:00pm)
E-mail: technical@vaillant.co.uk
Appendix
16 Operating instructions flexoTHERM 0020213396_00
Appendix A Overview of the operator's operating level
Setting level Values Unit Increment, se-
lect
Default setting
Setting
Min. Max.
Yield indicator
Energy yield: Day, Heating
Cumulative value
kWh
Energy yield: Day, Do­mestic hot water
Cumulative value
kWh
Energy yield: Day, Cooling
Cumulative value
kWh
Energy yield: Month, Heating
Cumulative value
kWh
Working figure: Month, Heating
Cumulative value
Energy yield: Total, Heating
Cumulative value
kWh
Working figure: Total, Heating
Cumulative value
Energy yield: Month, Domestic hot water
Cumulative value
kWh
Working figure: Month, Domestic hot water
Cumulative value
Energy yield: Total, Domestic hot water
Cumulative value
kWh
Working figure: Total, Domestic hot water
Cumulative value
Live Monitor
Current status mes­sage(s)
Current value
Building circuit pres­sure
Current value bar
Environment circuit pressure
Current value bar
Switch-on delay Current value min Flow temp. setpoint Current value Current flow temp. Current value
Energy integral Current value °min
Environment circuit inlet temperature
Current value
Environment circuit outlet temperature
Current value
Cooling capacity Current value kW
Appendix
0020213396_00 flexoTHERM Operating instructions 17
Setting level Values Unit Increment, se-
lect
Default setting
Setting
Min. Max.
Electrical power con­sumption
Current value kW Total power
consumption of the heat pump without any ex­ternal compon­ents connected (as-delivered condition).
Heating rod power Current value kW
Information
Contact data Phone number
Serial number Permanent
value
Operating hours total Cumulative
value
h
Hours heating Cumulative
value
h
DHW operating hours Cumulative
value
h
Cooling op. hours Cumulative
value
h
Basic settings
Language Current lan-
guage
01 Deutsch 02 English 03 Francais 04 Italiano 05 Dansk 06 Nederlands 15 Svenska 22 Slovenščina
02 English
Display contrast Current value 1 25
15 40
Resets Reset anti-cycl. time Cancel reset
anti-cycl. time?
Yes/No
0020213396_00   28.07.2015
Vaillant Ltd.
Nottingham Road   Belper   Derbyshire   DE56 1JT Telephone 03 30 100‑34 61   Telephone (renewables) 02 07 022‑09 28 Vaillant Service Solutions 03 30 100‑31 43   Spares Technical Enquiries 017 73 59 66 15 info@vaillant.co.uk   technicalspares@groupservice.co.uk
www.vaillant.co.uk
© These instructions, or parts thereof, are protected by copyright and may be reproduced or distributed only
with the manufacturer's written consent.
Loading...