Vaillant ecoTEC sustain 24, ecoTEC sustain 28, ecoTEC sustain 34, ecoTEC pure VCW 206/7-2, ecoTEC pure VC 146/7-2 Operating Instructions Manual

Operating instructions
ecoTEC sustain
24, 28, 34
GB
Operating instructions
Publisher/manufacturer
Vaillant GmbH
Contents
2 Operating instructions ecoTEC sustain 0020253095_01
Contents
1 Safety ............................................ 3
1.1 Action-related warnings ................. 3
1.2 Intended use .................................. 3
1.3 General safety information............. 4
2 Notes on the documentation ...... 7
2.1 Observing other applicable
documents ..................................... 7
2.2 Storing documents ......................... 7
2.3 Validity of the instructions .............. 7
3 Product description ..................... 7
3.1 Product design ............................... 7
3.2 Control elements............................ 7
3.3 Description of the display............... 8
3.4 Information on the identification
plate ............................................... 8
3.5 Serial number ................................ 9
3.6 CE label ......................................... 9
3.7 Energy Saving Trust Endorsed
Products......................................... 9
4 Function...................................... 10
4.1 Operating concept ....................... 10
4.2 Opening the isolator devices ....... 11
4.3 Switching on the product ............. 11
4.4 Setting the heating flow
temperature ................................. 11
4.5 Setting the hot water
temperature ................................. 11
4.6 Switching off the product's
functions ...................................... 12
4.7 Guaranteeing the correct filling
pressure in the heating circuit...... 12
4.8 Switching the product to
standby mode .............................. 13
4.9 Protecting the heating
installation against frost ............... 14
5 Troubleshooting ........................ 14
5.1 Detecting and rectifying faults...... 14
5.2 Displaying the status codes......... 14
6 Care and maintenance .............. 14
6.1 Maintenance ................................ 14
6.2 Caring for the product .................. 14
6.3 Reading maintenance
messages .................................... 15
6.4 Checking the condensate drain
pipework and tundish................... 15
7 Decommissioning...................... 15
7.1 Temporarily decommissioning
the product ................................... 15
7.2 Permanently decommissioning
the product ................................... 15
8 Recycling and disposal............. 15
9 Guarantee and customer
service ........................................ 16
9.1 Guarantee.................................... 16
9.2 Customer service ......................... 16
Appendix ............................................... 17
A Operator level – overview ......... 17
B Status codes – Overview........... 17
C Troubleshooting and fault
elimination.................................. 18
C.1 Troubleshooting ........................... 18
C.2 Rectifying faults ........................... 18
Safety 1
0020253095_01 ecoTEC sustain Operating instructions 3
1 Safety
1.1 Action-related warnings Classification of action-re-
lated warnings
The action-related warnings are classified in accordance with the severity of the pos­sible danger using the following warning signs and signal words:
Warning symbols and signal words
Danger!
Imminent danger to life or risk of severe personal injury
Danger!
Risk of death from electric shock
Warning.
Risk of minor personal injury
Caution.
Risk of material or envir­onmental damage
1.2 Intended use
There is a risk of injury or death to the user or others, or of dam­age to the product and other property in the event of im­proper use or use for which it is not intended.
The product is intended as a heat generator for closed heat-
ing installations and for hot wa­ter generation.
Intended use includes the fol­lowing:
– observance of the operating
instructions included for the product and any other system components
– compliance with all inspection
and maintenance conditions listed in the instructions.
This product can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervi­sion or instruction concerning use of the product in a safe way and understand the hazards in­volved. Children must not play with the product. Cleaning and user maintenance work must not be carried out by children unless they are supervised.
Any other use that is not spe­cified in these instructions, or use beyond that specified in this document shall be considered improper use. Any direct com­mercial or industrial use is also deemed to be improper.
Caution.
Improper use of any kind is prohibited.
1 Safety
4 Operating instructions ecoTEC sustain 0020253095_01
1.3 General safety information
1.3.1 Danger caused by
improper operation
Improper operation may present a danger to you and others, and cause material damage.
Carefully read the enclosed
instructions and all other ap­plicable documents, particu­larly the "Safety" section and the warnings.
Only carry out the activities
for which instructions are provided in these operating instructions.
1.3.2 Risk of death from
escaping gas
What to do if you smell gas in the building:
Avoid rooms that smell of
gas.
If possible, open doors and
windows fully and ensure adequate ventilation.
Do not use naked flames (e.g.
lighters, matches).
Do not smoke.Do not use any electrical
switches, mains plugs, door­bells, telephones or other communication systems in the building.
If it is safe to do so, close the
emergency control valve or the main isolator.
If possible, close the gas isol-
ator cock on the product.
Warn other occupants in the
building by yelling or banging on doors or walls.
Leave the building immedi-
ately and ensure that others do not enter the building.
Notify the gas supply com-
pany or the National Grid +44 (0) 800 111999 by tele­phone once you are outside of the building.
1.3.3 Risk of death due to a blocked or leaking flue gas pipe
What to do if you smell flue gas in the property:
Open all accessible doors
and windows fully to provide ventilation.
Switch off the product.Inform a competent person.
1.3.4 Risk of death due to explosive and flammable materials
Do not use or store explosive
or flammable materials (e.g. petrol, paper, paint) in the in­stallation room of the product.
Safety 1
0020253095_01 ecoTEC sustain Operating instructions 5
1.3.5 Risk of death due to changes to the product or the product environment
Never remove, bridge or
block the safety devices.
Do not tamper with any of the
safety devices.
Do not damage or remove
any seals on components.
Do not make any changes:
The product itselfto the gas, air, water and
electricity supplies
– to the entire flue gas install-
ation
– to the entire condensate
drain system
to the expansion relief valveto the drain pipeworkto constructional condi-
tions that may affect the operational reliability of the product
1.3.6 Risk of poisoning caused by insufficient supply of combustion air
Conditions: Open-flued opera-
tion
Ensure that there is a suffi-
cient supply of combustion air.
1.3.7 Risk of corrosion damage due to unsuitable combustion and room air
Sprays, solvents, chlorinated cleaning agents, paint, adhes­ives, ammonia compounds, dust or similar substances may lead to corrosion on the product and in the air/flue pipe.
Ensure that the supply of
combustion air is always free of fluorine, chlorine, sulphur, dust, etc.
Ensure that no chemical sub-
stances are stored at the in­stallation site.
1.3.8 Risk of material damage caused by frost
Ensure that the heating in-
stallation always remains in operation during freezing con­ditions and that all rooms are sufficiently heated.
If you cannot ensure the op-
eration, have a competent person drain the heating in­stallation.
1 Safety
6 Operating instructions ecoTEC sustain 0020253095_01
1.3.9 Risk of injury and material damage due to maintenance and repairs carried out incorrectly or not carried out at all
Never attempt to carry out
maintenance work or repairs on your product yourself.
Faults and damage should
be immediately rectified by a competent person.
Adhere to the maintenance
intervals specified.
Notes on the documentation 2
0020253095_01 ecoTEC sustain Operating instructions 7
2 Notes on the
documentation
2.1 Observing other applicable documents
You must observe all operating instruc-
tions enclosed with the system compon­ents.
2.2 Storing documents
Keep this manual and all other applic-
able documents safe for future use.
2.3 Validity of the instructions
These instructions apply only to:
Product article number
ecoTEC sustain 24
VUW 246/7-2 (H-GB)
0010019980
ecoTEC sustain 28
VUW 286/7-2 (H-GB)
0010019981
ecoTEC sustain 34
VUW 346/7-2 (H-GB)
0010019982
Gas Council Numbers
ecoTEC sustain 24
VUW 246/7-2 (H-GB)
47-044-79
ecoTEC sustain 28
VUW 286/7-2 (H-GB)
47-044-80
ecoTEC sustain 34
VUW 346/7-2 (H-GB)
47-044-81
3 Product description
3.1 Product design
3
2
1
1 Product 2 Control elements
3 Plate with serial
number on the rear
3.2 Control elements
3
4
6
5
7
1 2
1 Display 2 On/off button
and reset button
3 Right selection
button
4
button
5
button
6 Left selection
button
7 Access to the
menu for addi­tional inform­ation/installer level
3 Product description
8 Operating instructions ecoTEC sustain 0020253095_01
3.3 Description of the display
1
2
3
1 Operating in-
formation
2 Operating mode,
selecting and confirming the operating mode
3 Display showing
the current heat­ing flow temper­ature, the filling pressure in the heating install­ation, the oper­ating mode or a fault code
Symbol Meaning
Burner operating correctly
– Burner on
Heating installation filling pressure
– Permanently on: Filling
pressure in the permitted range
– Flashing: Filling pres-
sure outside the permitted range, purging function activated
DHW mode
– Permanently on: Hot wa-
ter activated
– Flashing: Burner on in
draw-off mode
Heating mode
– Permanently on: Heating
mode activated
– Flashing: Burner on in
heating mode
Maintenance required Information on maintenance messages in the event of faults
Setting to be confirmed
Navigating through various menus
Symbol Meaning
/ /
Fault in the product
– Appears instead of the
basic display.
S.XX
Status code
OFF – Heating mode is switched
off (summer mode)
– Hot water handling mode
is switched off (product with integrated hot water generation)
– Appears when the
product goes into standby mode.
3.4 Information on the identification plate
The identification plate is mounted on the underside of the product in the factory.
The identification plate keeps record of the country in which the product is to be installed.
Information on the identi­fication plate
Meaning
Condensing technology
Efficiency class of the boiler in accordance with EC Dir­ective 92/42/EEC
Serial number For quality control purposes;
3rd and 4th digits = year of production For quality control purposes; 5th and 6th digits = week of production For identification purposes; 7th to 16th digits = product article number For quality control purposes; 17th to 20th digits = place of manufacture
... ecoTEC ... Product designation
Cat. Approved gas category
Type: Xx3(x) Permissible flue gas connec-
tions
2H / 2E / 3P / 2K...
Gas group and gas connec­tion pressure as set at the factory
Product description 3
0020253095_01 ecoTEC sustain Operating instructions 9
Information on the identi­fication plate
Meaning
Tmax Max. flow temperature
PMS Maximum water pressure in
heating mode
NOx NOx class for the product
V Hz
Electric connection
W Max. electrical power con-
sumption
IP Protection class
Code (DSN) Specific product code
Heating mode
Qn Nominal heating load range
in heating mode
Pn Nominal heat output range
in heating mode
Pnc Nominal heat output range
in heating mode (condensing technology)
Hot water generation
Qnw Nominal heating load range
in hot water handling mode
Pnw Nominal heat output range
in hot water handling mode
D Specific flow rate
PMW Maximum water pressure in
hot water handling mode
Barcode with serial number
GC No. Gas council number
Note
Make absolutely sure that the product is compatible with the gas group at the installation site.
3.5 Serial number
The serial number can be found on the rear of a plastic plate at the bottom of the front casing and on the identification plate.
3.6 CE label
The CE label shows that the products comply with the basic requirements of the applicable directives as stated on the iden­tification plate.
The declaration of conformity can be viewed at the manufacturer's site.
3.7 Energy Saving Trust Endorsed Products
Only the most energy efficient products can carry the ‘Energy Saving Trust En­dorsed Product’ brandmark making it easy for consumers to choose products that have met strict energy performance cri­teria.
Available for: Boilers, Heating controls and chemical inhibitors, the Energy Saving Trust endorsed product brandmark gives consumers confidence that a product will cost less to run, help lower energy bills and reduce carbon emissions.
About the Energy Saving Trust
Energy Saving Trust is an independent and impartial organisation that provides trusted energy saving advice to empower millions of people to lead affordable, low energy lifestyles. For more information visit energysavingtrust.org.uk
4 Function
10 Operating instructions ecoTEC sustain 0020253095_01
4 Function
4.1 Operating concept
The display switches on when you switch on the product or press a button. You can now configure settings by pressing the buttons again.
When you switch the product off using the on/off button, the display goes out (the frost protection function is active for as long as power is supplied).
Button Meaning
– Setting the hot water temperat-
ure
– Cancelling the change to a set
value or activating an operating mode
– Calling up a higher selection
level in the menu
– Setting the heating flow tem-
perature, filling pressure of the heating system or activating the heating mode
– Confirming a set value or activ-
ating an operating mode
– Calling up a lower selection
level in the menu
– Read the system pressure
(press twice)
+
– Calling up the additional func-
tions
or
– Navigating between individual
menu items
– Increasing or decreasing the
chosen set value
– On/off button (press and hold
the button for < 3 s)
– Reset button (press and hold
the button for > 3 s)
Both selection buttons have a soft key function, i.e. their function can change.
If, for example, you press the left-hand selection button in the basic display, the current function switches from (Do­mestic hot water temperature) to (Back).
Adjustable values are always displayed as flashing.
You must always confirm a change to a value. Only then is the new setting saved. You can press to cancel a procedure at any time. If you do not press any buttons for longer 15 minutes, the display returns to the basic display.
4.1.1 Basic display
The basic display shows the current product status.
To return to the basic display, press the
button. If you do not press any buttons within three minutes, the display becomes dark and automatically switches back to the basic display.
If an error message appears, the error code will be shown on the basic display.
The available functions vary depending on whether:
– A room thermostat is connected to the
product or not – A domestic hot water cylinder with tem-
perature sensor is connected to the
product or not
4.1.2 Operating levels
The product has two operating levels:
– The operator level shows the most im-
portant information and offers set-up
options which do not require any special
prior knowledge. – Specialised knowledge is required in or-
der to use the installer level (access for
competent persons). This is therefore
protected by an access code.
Function 4
0020253095_01 ecoTEC sustain Operating instructions 11
4.2 Opening the isolator devices
1. Ask the competent person who in­stalled the product to explain to you where these isolator devices are loc­ated and how to handle them.
2. Open the gas isolator cock installed on-site.
3. Open the gas isolator cock, which is directly below the product or in its im­mediate vicinity.
4. Open the service valves in the heating installation's flow and return.
5. Open the cold water stop valve.
4.3 Switching on the product
1. Only start up the product once the cas­ing has been completely closed.
2. If the display is switched off, press for less than 3 seconds.
The basic display is shown in the
display.
4.4 Setting the heating flow
temperature
Note
If the eBUS room temperature con­trol is connected to the product, the domestic hot water temperat­ure and the heating flow temperat­ure cannot be set via the operating display.
Conditions: The temperature is controlled by the product
Press .
The heating flow temperature
flashes in the display.
Press the or button to set the tem-
perature.
is shown in the display.
Confirm by pressing .
Note
If you press the button again, the heating installation pressure is shown in the display.
Press .
The basic display is shown.
Conditions: Controller-regulated temperature
You cannot set the heating flow tem-
perature.
Note
If you press the button, the heating installation pressure is shown in the display.
4.5 Setting the hot water temperature
Note
If the eBUS room temperature con­trol is connected to the product, the domestic hot water temperat­ure and the heating flow temperat­ure cannot be set via the operating display.
4 Function
12 Operating instructions ecoTEC sustain 0020253095_01
Conditions: The temperature is controlled by the product
Press .
The domestic hot water temperature
now flashes in the display.
Press the or button to set the tem-
perature.
is shown in the display.
Press the button to confirm.Press .
The display switches to the basic
display.
Conditions: Controller-regulated temperature
Set the hot water temperature on the
controller. See the instructions for the controller.
4.6 Switching off the product's functions
4.6.1 Switching off heating mode (Summer mode)
Conditions: The temperature is controlled by the
product
Press .
The heating flow temperature
flashes in the display.
Press and press and hold until
OFF is shown in the display.
is shown in the display.
Confirm by pressing .
Heating mode is switched off.
Press .
The display switches to the basic
display.
Conditions: Controller-regulated temperature
You cannot switch off heating mode on
the product. See the instructions for the controller.
4.6.2 Switching off the hot water handling mode
Conditions: Temperature regulated by the product
or by the room temperature controller
Press .
The domestic hot water temperature
now flashes in the display.
Press and press and hold until
OFF is shown in the display.
is shown in the display.
Press to confirm.
Hot water generation is switched off.
Press .
The display switches to the basic
display.
4.7 Guaranteeing the correct filling pressure in the heating circuit
4.7.1 Checking the system pressure
Note
Your product has a pressure sensor and a digital pressure indicator.
The product switches to fault mode if the pressure falls below the re­quired system pressure (below
0.05 MPa (0.5 bar)). If the heating installation extends over several floors, a higher system pressure may be necessary. Ask your com­petent person for details.
1. Press twice.
The current system pressure is
shown in the display.
Function 4
0020253095_01 ecoTEC sustain Operating instructions 13
2. Check the system pressure on the display.
1 / 2
System pressure: 0.08 … 0.2 MPa (0.80 … 2.0 bar) The system pressure is in the intended pressure range.
2 / 2
System pressure: < 0.08 MPa (< 0.80 bar)
Fill the heating installation.
(Page 13)
When you have reached a suffi-
cient pressure range, the display disappears after 20 seconds.
4.7.2 Filling the heating installation
Caution. Risk of material damage due to heating water that is ex­tremely calciferous or corros­ive or contaminated by chem­icals.
Unsuitable tap water damages the seals and diaphragms, blocks components in the product and heating installation through which the water flows and causes noise.
Only fill the heating install-
ation with suitable heating water.
In case of doubt, ask a com-
petent person for details.
Note
The competent person is respons­ible for filling the heating installa­tion the first time.
1. On-site, connect the filling cock to a cold water pipe, as explained by the competent person.
2. Open all radiator valves (thermostatic radiator valves) of the heating installa­tion.
3. Open the cold water pipe.
4. Turn the filling cock on slowly and al­low water to flow in until the required system pressure has been reached.
5. Close the cold water pipe.
6. Purge all radiators.
7. Check the system pressure on the display. (Page 12)
8. Top up with more water if required.
9. Close the filling cock.
10. Disconnect the filling cock from the
cold water pipe.
4.8 Switching the product to
standby mode
Press the button for less than three
seconds.
Once the requirement currently in
use has finished, the display will show OFF and go out.
The product is now in standby mode.The product's frost protection func-
tion is activated.
The main power supply is not inter-
rupted. The product continues to be supplied with power.
5 Troubleshooting
14 Operating instructions ecoTEC sustain 0020253095_01
4.9 Protecting the heating installation against frost
4.9.1 Frost protection function
Caution. Risk of material damage due to frost.
The frost protection function cannot guarantee flow through the entire heating installation, which means that parts of the heating installation may freeze and therefore become dam­aged.
During a period of frost, en-
sure that the heating installa­tion remains in operation and that all rooms are sufficiently heated, even when you are away.
To keep the frost protection devices active, you should switch your product on and off using the controller, if one is provided.
If the heating flow temperature falls be­low 5 °C when the on/off button is on, the product comes into operation and heats the circulating water to approx. 30 °C on both the heating side and the hot water side (if available).
4.9.2 Draining the heating installation
When the unit is switched off for an exten­ded period, frost protection can be guar­anteed by completely draining the heating installation and the product.
Consult a competent person about this.
5 Troubleshooting
5.1 Detecting and rectifying faults
If faults occur or fault messages (F.XX)
are displayed, proceed as set out in the tables in the appendix.
If the product is not functioning cor-
rectly, contact a competent person.
5.2 Displaying the status codes
1. Press and at the same time.
S.XX is shown in the display, fol-
lowed by the heating flow temper­ature and the internal system pres­sure.
2. Look up the meaning of the status codes. Status codes – Overview (Page 17)
3. Press .
The display switches to the basic
display.
6 Care and maintenance
6.1 Maintenance
An annual inspection of the product carried out by a competent person is a prerequis­ite for ensuring that the product is perman­ently ready and safe for operation, reliable, and has a long working life.
6.2 Caring for the product
Caution. Risk of material damage caused by unsuitable clean­ing agents.
Do not use sprays, scouring
agents, detergents, solvents or cleaning agents that con­tain chlorine.
Clean the casing with a damp cloth and
a little solvent-free soap.
Decommissioning 7
0020253095_01 ecoTEC sustain Operating instructions 15
6.3 Reading maintenance messages
If the symbol is shown in the display, the product requires maintenance work.
The product is not in fault mode but contin­ues to operate.
Consult a competent person about this.If the water pressure is flashing at the
same time, simply add more heating water.
6.4 Checking the condensate drain pipework and tundish
The condensate drain pipework and tun­dish must always be penetrable.
Regularly check the condensate drain
pipework and tundish for faults and, particularly, for blockages.
You must not be able to see or feel any obstructions in the condensate drain pipe­work and tundish.
If you notice a fault, have it rectified by
a competent person.
7 Decommissioning
7.1 Temporarily decommissioning the product
Caution. Risk of material damage due to frost.
The frost protection and mon­itoring devices are only active while the unit is connected to the power mains and switched on via the on/off button, and when the gas isolator cock is open.
Temporarily decommission
the product only if no frost is expected.
Press the on/off button.
The display goes out.
When decommissioning the product
for a prolonged period (e.g. holiday), close the gas isolator cock and also, for combination products, the cold water stop valve.
7.2 Permanently decommissioning the product
Have a competent person permanently
decommission the product.
8 Recycling and disposal
The competent person who installed
your product is responsible for the dis­posal of the packaging.
If the product is identified with this
symbol:
In this case, do not dispose of the
product with the household waste.
Instead, hand in the product to a collec-
tion centre for old electrical or electronic appliances.
If the product contains batteries that are marked with this symbol, these bat­teries may contain substances that are hazardous to human health and the envir­onment.
In this case, dispose of the batteries at
a collection point for batteries.
9 Guarantee and customer service
16 Operating instructions ecoTEC sustain 0020253095_01
9 Guarantee and customer
service
9.1 Guarantee
– One year guarantee for ecoTEC sustain
appliances
Vaillant provides this appliance with a parts and labour guarantee against de­fects that may occur within twelve months of the installation date.
– Registering with us
Registration is simple. Just complete the Guarantee Registration Card and return to Vaillant within 30 days of installation. Your details will then be automatically registered within the Vaillant scheme.
– Immediate help
If your Vaillant boiler develops a fault your first action should be to contact your in­staller, as his professional assessment is needed under the terms of our Guarantee. If you are unable to contact your installer, phone Vaillant Service Solutions:
Telephone: 0330 100 3461
9.2 Customer service
To ensure regular servicing, it is strongly recommended that arrangements are made for a Maintenance Agreement. Please contact Vaillant Service Solutions for further details:
Telephone: 0330 100 3461
Appendix
0020253095_01 ecoTEC sustain Operating instructions 17
Appendix A Operator level – overview
Setting level Values Increment, select, explanation Default set-
ting
Min. Max.
DHW mode
Hot water temperature Current value < 35 = OFF OFF
35 60
Heating mode
Heating flow temperat­ure
Current value < 10 = OFF
Underfloor heating = 35-50 Radiator = 35-80
Note
The temperature range above 75 °C can only be set by a competent per­son.
OFF
10 80
B Status codes – Overview
Note
Since the code table is used for various products, some codes may not be vis­ible for the product in question.
Codes that are not listed here can be found in the installation instructions.
Status code Meaning
Displays in heating mode
S.00 Heating mode: No requirement
S.02 Heating mode: Pump pre-run
S.03 Heating mode: Burner ignition
S.04 Heating mode: Burner on
S.06 Heating mode: Fan overrun
S.07 Heating mode: Pump overrun
S.08 Heating mode: Temporary shutdown after heating procedure
Displays in hot water handling mode
S.10 Hot water handling mode: Requirement
S.14 DHW mode: Burner on
Display in Comfort mode with warm start or hot water handling mode with cylinder
S.20 Hot water handling mode: Requirement
S.22 Hot water handling mode: Pump pre-run
S.24 DHW mode: Burner on
Other displays
S.31 No heating demand: Summer mode, eBUS controller, waiting period
S.34 Frost protection active
Appendix
18 Operating instructions ecoTEC sustain 0020253095_01
Status code Meaning
S.46 Protection mode: Minimum load
C Troubleshooting and fault elimination
C.1 Troubleshooting
Symptom Possible cause Measure
The system pres­sure is flashing on the display
The system pressure is too low: < 0.05 MPa (< 0.50 bar). Low wa­ter pressure in the heating installation.
Fill the heating installation. (Page 13)
The system pressure is too high: > 0.3 MPa (> 3 bar).
Wait until the excess heating water has
flowed out through the expansion relief valve.
Product does not start up (no hot water, heating remains cold)
The gas isolator cock installed on-site and/or the gas isolator cock on the product is closed.
Open both gas isolator cocks.
The cold water stop valve is closed.
Open the cold water stop valve.
The product is switched off.
Switch on the product. (Page 11)
The heating flow tem­perature/hot water temperature has been set too low and/or the heating mode/hot wa­ter generation has been switched off.
1. Set the heating flow temperature.
2. Set the hot water temperature.
There is air in the heating installation.
Have a competent person purge the heating
installation.
Hot water generation functioning correctly; heating does not start up
The external controller is not set correctly.
Set the external controller correctly (Con-
troller operating instructions).
C.2 Rectifying faults
Message Possible cause Measure
F.28 Ignition unsuc­cessful
After three unsuc­cessful ignition at­tempts, the product has switched to fault mode.
1. Check whether the gas isolator cock is open.
2. Press the reset button for longer than three seconds.
3. If you have been unable to eliminate the ignition fault after the fault clearance at­tempt, consult a competent person.
0020253095_01 01.03.2017
Supplier
Vaillant Ltd.
Nottingham Road Belper Derbyshire DE56 1JT Telephone 0330 100 3461 info@vaillant.co.uk www.vaillant.co.uk
© These instructions, or parts thereof, are protected by copyright and may be reproduced or distributed only with the manufacturer's written consent.
We reserve the right to make technical changes.
0020253095_01