Vaillant ecoTEC plus 624, ecoTEC plus 612, ecoTEC plus 630, ecoTEC plus 637, ecoTEC plus 824, ecoTEC plus 831, ecoTEC plus 837, ecoTEC plus 615, ecoTEC plus 618 Instructions For Use Manual
Specifications and Main Features
Frequently Asked Questions
User Manual
For the owner
Instructions for use
ecoTEC
Wall hung room sealed fan assisted condensing boilers
ecoTEC plus 612
ecoTEC plus 615
ecoTEC plus 618
ecoTEC plus 624
ecoTEC plus 630
ecoTEC plus 637
The Vaillant ecoTEC plus and ecoTEC pro models are
compact, wall-mounted condensing appliances.
ecoTEC plus and pro combination boilers provides both
central heating and domestic hot water, with the domestic hot water supplied directly from the boiler. The boiler will operate automatically to provide domestic hot
water whenever a hot water tap is opened, and automatically adjusts to meet the demand for both central
heating and domestic hot water in the most economical
way.
ecoTEC system boilers provides central heating and
domestic hot water where a separate indirect hot water
cylinder is also incorporated to the system.
4.11 Maintenance and customer service . . . . . . . . . . . 14
2Instructions for use ecoTEC
Notes on the documentation 1
Safety 2
1 Notes on these instructions
To ensure clarity of information in instructions a new
European standard of advice and symbols is being introduced. To ensure compliance with this new standard the
following details are included.
The following information is intended to help you
throughout the boilers entire instruction pack.
We assume no liability for any damage caused by
non-observance of these instructions.
Other instruction supplied with this appliance
For the end user
Short operating instructions
(ecoTEC plus only) no. 838404
Warranty card with return envelope no. 802922
For the installer/service engineer:
Instructions for installation and servicing no. 839592
Flue installation instructions no. 835296
The instructions for any accessories and controllers
used also apply.
The Benchmark gas boiler commissioning checklist (in
the installation manual) should be completed by the
installer and/or the commissioning engineer.
If, after reading these instructions, you have any questions on the operation of the boiler, please contact
either your installer or Vaillant Technical Department.
1.1 Storage of the documents
Please store this user manual and all related documents
so that they are available whenever they are required.
If you move please pass on the documents to the buyer.
1.2 Symbols used in this manual
Please observe the safety instructions in this operating
manual for the operation of the appliance.
Danger
Immediate risk of serious injury or death.
These appliances also comply with the requirements of
the directive on operating efficiency (Council directive
92/42/EEC).
Vaillant Ltd. support the Benchmark initiative.
At the rear of the installation manual, you will
find a Benchmark gas boiler commissioning
checklist. It is very important that this is completed correctly at the time of instal lation,
commissioning and handover to the user.
1.4 Data badge
The type plate of the Vaillant ecoTEC is attached at the
factory to the bottom of the appliance.
2 Safety
2.1 Setup and adjustments
Installation and adjustment of the boiler as well as service, maintenance and repair of the boiler may only be
carried out by a competent person in accordance with
the Gas Safety (Installation and Use) Regulations 1998.
(In the U.K. “CORGI”. Registered installers undertake the
work to a safe and satisfactory standard). If the boiler is
installed in a compartment do not obstruct any purpose
provided ventilation openings, and do not use the compartment for storage purposes.
2.2 What to do in an emergency
Danger
Smell of gas. Risk of poisoning and explosion
due to a malfunction
Caution
Potentially dangerous situations for the product and environment.
Note
Useful information and instructions.
• Symbol for a necessary task
1.3 CE marking
The purpose of CE marking is to certify that the boiler
complies with the requirements of the directives
covering gasfired appliances (Council directive 90/396/
EEC) and electromagnetic compatibility (Council directive 89/336/EEC).
If you smell gas or suspect a gas leak:
• Do not switch lights on or off.
• Do not use any other electrical switches.
• Do not use a telephone in the hazardous area.
• Do not use naked flames, such as matches or cigarette
lighters.
• Do not smoke.
• Turn off the gas supply at the gas meter.
• Open the windows and doors.
• Warn other residents.
• Get out of the house.
• Consult your gas supplier, service agent or other competent person.
3Instructions for use ecoTEC
2 Safety
2.3 Safety instructions
Always observe the following safety instructions and
regulations.
Danger
Inflammable mixtures of gas and air may
explode.
Do not use or store explosive or easily flammable substances such as petrol or paint in the
same room as the appliance.
Danger
Risk of poisoning and explosion due to a malfunction.
Never put the safety devices out of operation or
tamper with them so as to impair their function.
2.4 Modifications in and around the boiler
No modifications may be made to the following items:
- The boiler
- The gas, water and electrical supply
- The flue system
- The safety valve for the heating water
- Any structural changes around the appliance that
could affect the operational safety of the boiler.
Caution
Inappropriate modifications can cause damage.
Never tamper with the boiler or other parts of
the system.
Never attempt to perform maintenance or
repairs yourself.
- Do not damage or remove seals on components. Only
authorised engineers or our customer service may
removed sealed components.
Danger
Risk of scalding.
The water coming out of the tap can be very
hot (ecoTEC combination boiler only).
Installation and setting
Important:
The appliance must be installed and serviced by
a Competent Person as stated in the Gas Safety
(Installation and Use) Regulations 1998. In IE,
the installation must be in accordance with the
current edition of I.S.813 ‘Domestic Gas Installations’, the current Building Regulations and
reference should be made to the current ETCI
rules for electrical installation.
Caution
The appliance may only be operated with its
case properly and permanently closed.
Otherwise, in unfavourable conditions, material
damage or even injury or death can result.
Filling pressure of the heating system
Regularly check the filling pressure of the heating system (see 4.3.2).
Leaks (ecoTEC combination boiler only)
If there is a leak in the water pipes between the appliance and the taps, immediately turn off the cold water
service valve and have your engineer repair the leak.
Frost protection
Your boiler is equipped with a frost protection function:
If the heating water temperature drops below 5 °C when
the main switch is ON, then the boiler goes into operation and heats the boiler circuit to approx. 30 °C.
Note
It cannot be guaranteed that water will circulate throughout the entire heating system.
If the boiler is not operated for several hours during
very cold weather there is therefore the possibility of
the system freezing.
Please ensure that if you are absent during a period of
frost the central heating remains in operation and all
rooms are kept above freezing point.
Caution
Risk of damage.
Do not use sprays, solvents, chlorinated cleaning agents, paint, adhesives or similar substances in the vicinity of the appliance. These
substances can cause corrosion, including in
the flue system.
4Instructions for use ecoTEC
It must be remembered, however, that the boiler will be
automatically switched off by the built in monitoring
devices if certain faults occur, e.g. interruption in the gas
or electricity supply or faults in the flue gas system. To
overcome this possibility you can drain both the central
heating system and boiler.
Note
Frost protection and monitoring devices can
only function when the main switch of the unit
is set to the “I” position and the boiler is connected to the electrical supply.
Instructions on operation 3
3 Instructions on operation
3.1 Factory guarantee
3.1.1 Two 2 year guarantee for ecoTEC plus appli-
ances
Vaillant undertakes to rectify any manufacturing defect
that occurs within twenty-four months of the installation
date.
For the 2nd year of the guarantee to be valid an annual
service must be carried out by a CORGI registered installer one year after installation.
The cost of this annual service is not included in the
guarantee.
3.1.2 One year guarantee for ecoTEC pro appliances
Vaillant undertakes to rectify any manufacturing defect
that occurs within twelve months of the installation date.
3.1.3 Registering with us
Registration is simple. Just complete the Guarantee
Registration Card and return to Vaillant within 30 days
of installation. Your details will then be automatically
registered within the Vaillant scheme.
Note
No receipt will be issued.
3.3 Care
• Clean the exterior your appliance with a damp cloth
and a little soap.
Note
Do not use scouring or cleaning agent, which
might damage the housing or plastic fittings.
3.4 Recycling and disposal
Both your Vaillant ecoTEC boiler and its packaging consist mainly of recyclable raw materials.
3.4.1 The appliance
Do not dispose of your Vaillant ecoTEC boiler or any of
its accessories with household waste. Make sure the old
appliance and any existing accessories are disposed of
properly.
3.4.2 Packaging
Please leave the disposal of the transport packaging to
the expert company which installed the appliance.
Note
Please observe the applicable national legal
regulations.
3.1.4 Immediate help
If your Vaillant boiler develops a fault your first action
should be to contact your installer, as his professional
assessment is needed under the terms of our Guarantee.
If you are unable to contact your installer, phone Vaillant
Service Solutions: 0870 6060 777
3.2 Intended use
Vaillant ecoTEC boilers are state-of-the-art appliances
which have been constructed in accordance with recognised safety regulations. Nevertheless, there is a risk of
injury or death to the user or others and damage to the
appliance or other property in the event of misuse or
use for which the appliance is not intended.
The appliances are designed to generate heat for connected hot water central heating systems. Any other use
is considered to be use other than intended. The
manufacturer/supplier is not liable for any resulting
damage. The user alone bears the risk.
Intended use includes the observance of the operating
and installation manual and all other applicable documents, as well as adherence to the maintenance and
inspection conditions.
Caution
Any incorrect use is forbidden.
5Instructions for use ecoTEC