Contents Appliance characteristics
Contents
Appliance characteristics . . . . . . . . . . . . . . . . . . . . . 2
1 Notes on these instructions . . . . . . . . . . . . . . 3
1.1 Storage of the documents . . . . . . . . . . . . . . . . . . . 3
1.2 Symbols used in this manual . . . . . . . . . . . . . . . . . 3
1.3 CE marking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
1.4 Data badge . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
2 Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
2.1 Setup and adjustments . . . . . . . . . . . . . . . . . . . . . . 3
2.2 What to do in an emergency . . . . . . . . . . . . . . . . . 3
2.3 Safety instructions . . . . . . . . . . . . . . . . . . . . . . . . . . 4
2.4 Modifications in and around the boiler . . . . . . . . 4
3 Instructions on operation . . . . . . . . . . . . . . . . 5
3.1 Factory guarantee . . . . . . . . . . . . . . . . . . . . . . . . . . 5
3.1.1 Two 2 year guarantee for ecoTEC plus
appliances . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
3.1.2 One year guarantee for ecoTEC pro appliances . 5
3.1.3 Registering with us . . . . . . . . . . . . . . . . . . . . . . . . . 5
3.1.4 Immediate help . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
3.2 Intended use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
3.3 Care . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
3.4 Recycling and disposal . . . . . . . . . . . . . . . . . . . . . . 5
3.4.1 The appliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
3.4.2 Packaging . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Appliance characteristics
The Vaillant ecoTEC plus and ecoTEC pro models are compact, wall-mounted condensing appliances. ecoTEC plus and pro combination boilers provides both central heating and domestic hot water, with the dome­stic hot water supplied directly from the boiler. The boi­ler will operate automatically to provide domestic hot water whenever a hot water tap is opened, and auto­matically adjusts to meet the demand for both central heating and domestic hot water in the most economical way. ecoTEC system boilers provides central heating and domestic hot water where a separate indirect hot water cylinder is also incorporated to the system.
4 Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
4.1 Overview of controls on ecoTEC plus . . . . . . . . . . 6
4.2 Overview of controls on ecoTEC pro . . . . . . . . . . 7
4.3 Initial checks before turning on . . . . . . . . . . . . . . 8
4.3.1 Opening the service valves . . . . . . . . . . . . . . . . . . 8
4.3.2 Checking the system pressure . . . . . . . . . . . . . . . . 8
4.4 Turning the boiler ON . . . . . . . . . . . . . . . . . . . . . . . 9
4.5 Domestic hot water with ecoTEC combination
boilers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
4.5.1 Setting the water temperature . . . . . . . . . . . . . . . 9
4.5.2 Switching the warmstart function on and off . . . 10
4.5.3 Drawing hot water (ecoTEC combination
boilers only) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
4.6 Heating operation . . . . . . . . . . . . . . . . . . . . . . . . . . 11
4.6.1 Setting the maximum radiator temperature
control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
4.6.2 Switching off heating (summer operation) . . . . . 11
4.6.3 Setting a room- or outside temperature
controller . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
4.7 Status displays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
4.8 Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
4.8.1 Problems due to low system water pressure . . . 13
4.8.2 Ignition problems . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
4.8.3 Flue problems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
4.9 Turning off the boiler . . . . . . . . . . . . . . . . . . . . . . . 13
4.10 Frost protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
4.11 Maintenance and customer service . . . . . . . . . . . 14
2 Instructions for use ecoTEC
Notes on the documentation 1
Safety 2
1 Notes on these instructions
To ensure clarity of information in instructions a new European standard of advice and symbols is being intro­duced. To ensure compliance with this new standard the following details are included. The following information is intended to help you throughout the boilers entire instruction pack.
We assume no liability for any damage caused by non-observance of these instructions.
Other instruction supplied with this appliance For the end user
Short operating instructions (ecoTEC plus only) no. 838404 Warranty card with return envelope no. 802922
For the installer/service engineer:
Instructions for installation and servicing no. 839592 Flue installation instructions no. 835296
The instructions for any accessories and controllers used also apply.
The Benchmark gas boiler commissioning checklist (in the installation manual) should be completed by the installer and/or the commissioning engineer.
If, after reading these instructions, you have any ques­tions on the operation of the boiler, please contact either your installer or Vaillant Technical Department.
1.1 Storage of the documents
Please store this user manual and all related documents so that they are available whenever they are required. If you move please pass on the documents to the buyer.
1.2 Symbols used in this manual
Please observe the safety instructions in this operating manual for the operation of the appliance.
Danger
Immediate risk of serious injury or death.
These appliances also comply with the requirements of the directive on operating efficiency (Council directive 92/42/EEC).
Vaillant Ltd. support the Benchmark initiative.
At the rear of the installation manual, you will find a Benchmark gas boiler commissioning checklist. It is very important that this is com­pleted correctly at the time of instal lation, commissioning and handover to the user.
1.4 Data badge
The type plate of the Vaillant ecoTEC is attached at the factory to the bottom of the appliance.
2 Safety
2.1 Setup and adjustments
Installation and adjustment of the boiler as well as serv­ice, maintenance and repair of the boiler may only be carried out by a competent person in accordance with the Gas Safety (Installation and Use) Regulations 1998. (In the U.K. “CORGI”. Registered installers undertake the work to a safe and satisfactory standard). If the boiler is installed in a compartment do not obstruct any purpose provided ventilation openings, and do not use the com­partment for storage purposes.
2.2 What to do in an emergency
Danger
Smell of gas. Risk of poisoning and explosion due to a malfunction
Caution
Potentially dangerous situations for the prod­uct and environment.
Note
Useful information and instructions.
• Symbol for a necessary task
1.3 CE marking
The purpose of CE marking is to certify that the boiler complies with the requirements of the directives covering gasfired appliances (Council directive 90/396/ EEC) and electromagnetic compatibility (Council directi­ve 89/336/EEC).
If you smell gas or suspect a gas leak:
• Do not switch lights on or off.
• Do not use any other electrical switches.
• Do not use a telephone in the hazardous area.
• Do not use naked flames, such as matches or cigarette lighters.
• Do not smoke.
• Turn off the gas supply at the gas meter.
• Open the windows and doors.
• Warn other residents.
• Get out of the house.
• Consult your gas supplier, service agent or other com­petent person.
3Instructions for use ecoTEC
2 Safety
2.3 Safety instructions
Always observe the following safety instructions and regulations.
Danger
Inflammable mixtures of gas and air may explode. Do not use or store explosive or easily flamma­ble substances such as petrol or paint in the same room as the appliance.
Danger
Risk of poisoning and explosion due to a mal­function. Never put the safety devices out of operation or tamper with them so as to impair their func­tion.
2.4 Modifications in and around the boiler
No modifications may be made to the following items:
- The boiler
- The gas, water and electrical supply
- The flue system
- The safety valve for the heating water
- Any structural changes around the appliance that could affect the operational safety of the boiler.
Caution
Inappropriate modifications can cause damage. Never tamper with the boiler or other parts of the system. Never attempt to perform maintenance or repairs yourself.
- Do not damage or remove seals on components. Only authorised engineers or our customer service may removed sealed components.
Danger
Risk of scalding. The water coming out of the tap can be very hot (ecoTEC combination boiler only).
Installation and setting
Important:
The appliance must be installed and serviced by a Competent Person as stated in the Gas Safety (Installation and Use) Regulations 1998. In IE, the installation must be in accordance with the current edition of I.S.813 ‘Domestic Gas Instal­lations’, the current Building Regulations and reference should be made to the current ETCI rules for electrical installation.
Caution
The appliance may only be operated with its case properly and permanently closed. Otherwise, in unfavourable conditions, material damage or even injury or death can result.
Filling pressure of the heating system
Regularly check the filling pressure of the heating sys­tem (see 4.3.2).
Leaks (ecoTEC combination boiler only)
If there is a leak in the water pipes between the appli­ance and the taps, immediately turn off the cold water service valve and have your engineer repair the leak.
Frost protection
Your boiler is equipped with a frost protection function: If the heating water temperature drops below 5 °C when the main switch is ON, then the boiler goes into operati­on and heats the boiler circuit to approx. 30 °C.
Note
It cannot be guaranteed that water will circula­te throughout the entire heating system.
If the boiler is not operated for several hours during very cold weather there is therefore the possibility of the system freezing. Please ensure that if you are absent during a period of frost the central heating remains in operation and all rooms are kept above freezing point.
Caution
Risk of damage. Do not use sprays, solvents, chlorinated clean­ing agents, paint, adhesives or similar sub­stances in the vicinity of the appliance. These substances can cause corrosion, including in the flue system.
4 Instructions for use ecoTEC
It must be remembered, however, that the boiler will be automatically switched off by the built in monitoring devices if certain faults occur, e.g. interruption in the gas or electricity supply or faults in the flue gas system. To overcome this possibility you can drain both the central heating system and boiler.
Note
Frost protection and monitoring devices can only function when the main switch of the unit is set to the “I” position and the boiler is con­nected to the electrical supply.
Instructions on operation 3
3 Instructions on operation
3.1 Factory guarantee
3.1.1 Two 2 year guarantee for ecoTEC plus appli-
ances
Vaillant undertakes to rectify any manufacturing defect that occurs within twenty-four months of the installation date. For the 2nd year of the guarantee to be valid an annual service must be carried out by a CORGI registered instal­ler one year after installation. The cost of this annual service is not included in the guarantee.
3.1.2 One year guarantee for ecoTEC pro appliances
Vaillant undertakes to rectify any manufacturing defect that occurs within twelve months of the installation date.
3.1.3 Registering with us
Registration is simple. Just complete the Guarantee Registration Card and return to Vaillant within 30 days of installation. Your details will then be automatically registered within the Vaillant scheme.
Note
No receipt will be issued.
3.3 Care
• Clean the exterior your appliance with a damp cloth and a little soap.
Note
Do not use scouring or cleaning agent, which might damage the housing or plastic fittings.
3.4 Recycling and disposal
Both your Vaillant ecoTEC boiler and its packaging con­sist mainly of recyclable raw materials.
3.4.1 The appliance
Do not dispose of your Vaillant ecoTEC boiler or any of its accessories with household waste. Make sure the old appliance and any existing accessories are disposed of properly.
3.4.2 Packaging
Please leave the disposal of the transport packaging to the expert company which installed the appliance.
Note
Please observe the applicable national legal regulations.
3.1.4 Immediate help
If your Vaillant boiler develops a fault your first action should be to contact your installer, as his professional assessment is needed under the terms of our Guarantee. If you are unable to contact your installer, phone Vaillant Service Solutions: 0870 6060 777
3.2 Intended use
Vaillant ecoTEC boilers are state-of-the-art appliances which have been constructed in accordance with recog­nised safety regulations. Nevertheless, there is a risk of injury or death to the user or others and damage to the appliance or other property in the event of misuse or use for which the appliance is not intended. The appliances are designed to generate heat for con­nected hot water central heating systems. Any other use is considered to be use other than intended. The manufacturer/supplier is not liable for any resulting damage. The user alone bears the risk. Intended use includes the observance of the operating and installation manual and all other applicable docu­ments, as well as adherence to the maintenance and inspection conditions.
Caution
Any incorrect use is forbidden.
5Instructions for use ecoTEC
Loading...