Video, Power, Network and Control Extension System over a Single Cat-5e/6 Cable at
distances up to 328’ (100m) featuring HDBaseT™ for use with Cisco® Precision 60 Camera
and SX series codec.
Part Numbers
999-9560-000 OneLINK System for Cisco Precision Cameras (North Ameri ca)
999-9560-001 OneLINK System for Cisco Precision Cameras (International )
Image: OneLINK EZIM Camera Interface with Connector Call-outs ................................................................. 5
Determine Camera Mounting Location ...................................................................................................................... 6
Camera and EZIM Mounting Instructions .................................................................................................................. 6
Image: Precision 60 Wall Mount with EZIM Attached ....................................................................................... 6
Basic System Configuration ...................................................................................................................................... 7
Diagram: Basic Connectivity of the OneLINK System ...................................................................................... 7
Operating the OneLINK: ..................................................................................................................................... 7
The OneLINK Screen Shot Tour ............................................................................................................................... 8
DHCP IP Set-up (Dynamic Host Configuration Protocol) ...................................................................................... 8
Static IP Set-up: ..................................................................................................................................................... 8
Screen Shot: Home Page .................................................................................................................................. 8
Screen Shot - Admin Menu - Help .................................................................................................................... 12
Screen Shot: System Menu ............................................................................................................................. 13
Screen Shot: System Menu - Firmware Update Confirmation ........................................................................ 13
Screen Shot: System Menu - Restore Factory Settings Confirmation ............................................................ 14
General Specifications ............................................................................................................................................. 15
Appendix 1: Connectors and signals ...................................................................................................................... 15
Compliance and CE Declaration of Conformity - OneLINK HDMI Interface ........................................................... 16
Compliance and CE Declaration of Conformity - OneLINK HDMI EZIM ................................................................. 17
Warranty Information ............................................................................................................................................... 18
OneLINK for Precision 60 - Document Number 342-1036 Page 2 of 20
Vaddio OneLINK for Precision 60
OVERVIEW
Vaddio’s OneLINK System is a digital camera
extension system that extends HDMI video, power
network and control on a single Cat-5e/6 cable at
distances of up to 328’ (100m). The OneLINK
system sends and regulates power to the camera,
provides a bi-directional control channel for Ethernet
and transmits/receives uncompressed HDMI digital
video up to 1080p/60 for the Precision 60 camera.
The system consists of the small OneLINK EZIM (EZCamera™ Interface Module) camera interface at the camera
location and the OneLINK HDMI Interface. The EZIM provides the required camera connectivity and is mounted t o
the back of the included wall mount bracket with two 6-32 x .188” black mounting screws. All camera side cables
and codec side cables are provided with the OneLINK system. The wall mount bracket can be mounted directly to
a 2-gang sized electrical box for conduit installations or directly to the dry wall with wall anchors.
From one end to the other, the OneLINK system provides system integrators and end users a simplified product
based on the vast experience Vaddio has in cameras and cable extension systems.
Please use this manual in conjunction with the manual for the camera attached to the OneLINK System.
Intended Use
Before operating the device, please read the entire manual thoroughly. The system was designed, built and
tested for use indoors, and with the provided power supply and cabling. The use of a power supply other than the
one provided or outdoor operation has not been tested and could damage the device and/or create a potentially
unsafe operating condition.
Save These Instructions
The information contained in this manual will help you install and operate your product. If these instructions are
misplaced, Vaddio keeps copies of Specifications, Installation and User Guides and most pertinent product
drawings for the Vaddio product line on the Vaddio website. These documents can be downloaded from
www.vaddio.com free of charge.
Important Safeguards
Read and understand all instructions before using. Do not operate any device if it has been dropped or damaged.
In this case, a Vaddio technician must examine the product before operating. To reduce the risk of electric shock,
do not immerse in water or other liquids and avoid extremely humid conditions.
Use only the power supply provided with the system. Use of any unauthorized power supply will
void any and all warranties.
Please do not use “pass-thru” type RJ-45 connectors. These pass-thru type connectors do not
work well for professional installations and can be the cause of intermittent connections. For
best results please use standard RJ-45 connectors, real crimpers and test all cables for proper
pin-outs prior to use and connection to Vaddio Cat-5e/6 products.
Important Note
OneLINK systems are not compatible with previous versions of OneLINK codec camera extenders. The
specifications are different and will not function if parts from either system are mixed. The older systems are those
with Quick-Connect part number 998-1105-019 and EZIM part number 998-6700-003. Connecting these to a new
OneLINK system may cause failure and void warranty.
Images: OneLINK HDMI Interface
(above) and the OneLINK EZIM
Camera Interface (right),
OneLINK for Precision 60 - Document Number 342-1036 Page 3 of 20
Vaddio OneLINK for Precision 60
Unpacking
Carefully remove the product and all of the included parts from the packaging. Identify the following parts:
OneLINK System for Precision 60 (North America)
Part Number 999-9560-000 Includes:
One (1) 998-1105-043 OneLINK HDMI Interface
One (1) 998-6700-043 OneLINK EZIM Camera Interface
One (1) Vaddio 48 VDC, 1.36 Amp Switching Power Supply with North American AC Cord Set
One (1) 12” (305mm) HDMI M to M Video Cable (camera side)
One (1) 12” (305mm) Cat-5e Network Patch Cable (camera side)
One (1) 12” (305mm) Camera Power Cable (camera side)
One (1) 36” (915mm) Cat-5e Network Control Cable (codec side)
One (1) 36” (915mm) HDMI M to M Cable (codec side)
One (1) Wall Mount Bracket with mounting hardware
Two (2) 6-32 x .188” Black Phillips head screws to mount EZIM to the Wall Mount
One (1) Quick Start Guide
(Camera not included)
OneLINK System for Precision 60 (International)
Part Number 999-9560-000 Includes:
One (1) 998-1105-043 OneLINK HDMI Interface
One (1) 998-6700-043 OneLINK EZIM Camera Interface
One (1) Vaddio 48 VDC, 1.36 Amp Switching Power Supply
One (1) Euro Power Cord
One (1) UK Power Cord
One (1) 12” (305mm) HDMI M to M Video Cable (camera side)
One (1) 12” (305mm) Cat-5e Network Patch Cable (camera side)
One (1) 12” (305mm) Camera Power Cable (camera side)
One (1) 36” (915mm) Cat-5e Network Control Cable (codec side)
One (1) 36” (915mm) HDMI M to M Cable (codec side)
One (1) Wall Mount Bracket with mounting hardware
Two (2) 6-32 x .188” Black Phillips head screws to mount EZIM to the Wall Mount
One (1) Quick Start Guide
(Camera not included)
Image: OneLINK HDMI Interface with Front Panel Feature Call-outs
①
②
1. Blue Backlit Display: A two row, 20 character display displays the IP and MAC addresses for access to internally served
web pages. These web pages are currently used only for easy firmware updates in the unlikely event the OneLINK system
ever requires a firmware update.
2. Power / System Reset: Blue power indicator lamp and recessed momentary reset button indicates presence of power with
a blue LED. Press this recessed button for a system reset if required.
OneLINK for Precision 60 - Document Number 342-1036 Page 4 of 20
Vaddio OneLINK for Precision 60
Image: OneLINK HDMI Interface with Rear Panel Connector Call-outs
②① ③④⑤ ⑥
1. Power Input Jack: Coaxial 5.5mm OD x 2.5mm ID power jack with positive center for use with supplied 48VDC, 1.36A
power supply. This power jack supplies power to both ends of the OneLINK system as well as the camera.
2. OneLINK Interface Port: Shielded RJ-45 jack for connecting a single Cat-5e or better cable for connectivity to the EZIM
(TX) at the camera location to the OneLINK HDMI Interface (Rx). Cat-6 or Cat-7 cabling might provide better performance
in noisier RF or EMF environments - when in doubt, use shielded Cat-6 cable. Cable distance between the OneLINK EZIM
and OneLINK HDMI Interface is a maximum of 328 feet (100 m).
3. HDMI Output: HDMI output to provide camera HDMI signal.
4. RS-232 port:
Shielded RJ-45 jack for connecting a bi-directional RS-232 signal to be transported by the
OneLINK system (if required. This signal will be transported on the OneLINK system simultaneously with the
other signals
5. IR Forwarding: 3-pin Phoenix-style connector for for warded IR signals from the camera EZIM. Modulated and nonmodulated outputs provided. Note: IR Forwarding is not used with the Precision 60 camera and SX series codecs.
6. Network IP Port: Shielded RJ-45 network jack for transport of Ethernet signals for camera control or webserver access.
Image: OneLINK EZIM Camera Interface with Connector Call-outs
⑤
②
③
④
Front View
①
⑥
1. Camera Power Jack: EIAJ-04 coaxial power connection to provide power to the camera. An appropriate
cable is provided to connect the camera to this jack.
2. Ethernet Port: Shielded RJ-45 network jack provided to allow connection of Ethernet control to the camera.
3. RS-232: Shielded RJ-45 jack for bi-directional RS-232 connection to camera.
4. HDMI Connection: HDMI connector for HDMI video signal coming from the camera to be inserted into the EZ IM for
transport.
5. Mounting flange: A convenient mounting flange is pr ovided for mounting the EZIM to the camera’s included wall mount
or to another appropriately located position.
6. OneLINK Interface Port: Shielded RJ-45 jack for connecting a single Cat-5e or better cable for connectivity to the EZIM
(TX) at the camera location to the OneLINK HDMI Interface (Rx). Shielded Cat-6 cabling will provide better performance in
noisier RF or EMI environments - when in doubt, use shielded Cat-6 cable. Cable dista nce between the OneLINK EZIM
and OneLINK HDMI Interface is a maximum of 328 feet (100 m).
OneLINK for Precision 60 - Document Number 342-1036 Page 5 of 20
Vaddio OneLINK for Precision 60
DETERMINE CAMERA MOUNTING LOCATION
When locating the camera, consider viewing angles, lighting conditions, possible line of site obstructions and check
for in-wall or in-ceiling obstructions where the camera is to be mounted. Always pick a mounting location to optimize
the performance of the camera. Please locate the camera to enable easy positioning of the camera body with the
ability to point down and away from the ceiling and a pile of fluorescent lighting cells. Cameras generally don’t like to be swamped with fluorescent light and nobody sits on the ceiling anyway.
After determining the optimum location of the camera system, pull and route the required Cat-6 cable from the
Camera/EZIM location back to the OneLINK Interface location (head-end).
CAMERA AND EZIMMOUNTING INSTRUCTIONS
The wall mount for the HDMI Cameras has two threaded 6-32 inserts on the back of the mount to attach EZIM to
the Mount. The camera platform has four (4) small holes for mounting the camera to the mou nt with the provided
M3 x 6mm pan head screws platform. It also has a slot for a ¼”-20 screw that is not used with the Polycom
camera.
If the wall mount is to be mounted on a 2-gang wall box, use the screws supplied with the wall box cover plate to
attach Thin Profile Wall Mount Bracket. If mounting to drywall with wall anchors, use the four (4) quality wall anchors
and screws provided with the mount. The Thin Profile Wall Mount Bracket’s mounting holes are slotted and are 9 0°
opposing to provide easy leveling. Level the mount and place the camera on the mount.
The OneLINK Kit for the Precision 60 includes two (2) 6-32 x .188” pan head screws. Use these screws to attach
the EZIM to the back of the mount.
Use the provided ¼”-20 mounting screw to attach the camera to the mount. This step is best performed after the
camera and EZIM are cabled (see next page).
Image: Precision 60 Wall Mount with EZIM Attached
Note: The mount may look slightly different than the mount depicted.
EZIM
Slot for ¼”-20
Screw
Two 6-32 Threaded
Holes for 6-32 x
.188” screws
OneLINK for Precision 60 - Document Number 342-1036 Page 6 of 20
(
pply
Vaddio OneLINK for Precision 60
BASIC SYSTEM CONFIGURATION
The OneLINK HDMI EZIM and OneLINK HDMI Interface are connected to each other via one Cat-6 cable plugged
into the purple “OneLINK” ports at either end.
Installation
Step 1: Connect the 1’ (305mm) Mini HDCI to fan-out cable (EIAJ-04 power plug, the RS-232/IR Cat-5e with RJ-
45 plug and HDMI plug) from the OneLINK EZIM to the camera.
Step 2: Connect the OneLINK ports with a quality Cat-5e/6.
shielded Cat-6 cable. Cable distance between the OneLINK EZIM and Interface is a maximum of 328 feet (100 m) on Cat-6.
Step 3: At the codec side, connect HDCI connector to the codec and the HDMI plug, RJ-45 plug for RS-232 and a single cable
whip (for non-modulated IR) to the OneLINK interface. Connect the supplied 48 VDC, 1.36 Amp po wer supply to the OneLIN K
Interface and the codec/camera will boot up and will be ready for operation
Please see the camera manual for setup and configuration of the video and other camera settings.
Diagram: Basic Connectivity of the OneLINK System
OneLINK HDMI - EZIM Camera Interface
Power
Network
Cisco Precision 60 Cameras and Mount
(camera not included)
48 VDC, 1.36 Amp
Power Su
No simulated dolphins were harmed
during the making of this simulated video.
HDMI
Operating the OneLINK:
Power up OneLINK system, then bring up the codec. Camera should function as it would without an
extension system. There are very few points regarding operation, it is designed to be plug-n-play.
In noisier RF or EMF environments - when in doubt, use
HDMI
OneLINK Digital Bus
Video, Power and Control up to
328’
100m) on Cat-6 Cable
OneLINK HDMI Digital Camera Interface
HDMI
Cisco SX-80
Network
OneLINK for Precision 60 - Document Number 342-1036 Page 7 of 20
Vaddio OneLINK for Precision 60
ONELINKDISPLAY
The OneLINK HDMI Interface that has a 2-line LCD that displays the interfaces IP and MAC (HW for hardware)
addresses. This is used to access the embedded web server for future firmware updates in the unlikely event they
are ever required.
Web Page Configuration and Structure
To access the Configuration pages served by the OneLINK, connect the Network port to either a Network or PC.
This Ethernet connection to the Quick-Connect is required and will use the IP address displayed on the front of the
unit. If DHCP is configured on the network, the display will show the assigned address allowing access to the web
pages.
THE ONELINKSCREEN SHOT TOUR
The OneLINK Interface uses a Linux OS and has a built-in web server. The internal web pages will allow
configuration and simple control of the interface via Ethernet network connection. These web pages will allow the
user or administrator to set security passwords, change the IP address, view diagnostics, access the firmware
upgrade page and many more exciting things.
DHCP IP Set-up (Dynamic Host Configuration Protocol)
DHCP Set-up (skip this section if Static IP). If the LAN has a DHCP (dynamic host configuration protocol) server, then the IP address,
gateway and routing information will automatically be assigned. The software is defaulted to DHCP and will attempt to dynamically obtain an
IP address using DHCP, but it will fall back to the default address of (169.254.1.1) if no DHCP server can be found.
Static IP Set-up:
The static IP can be assigned either through the network or directly to a computer using a cross-over cable. Depending on t he age of the
computer, you may not need a cross-over cable. Either way the steps are the same for network or direct connection to a computer. The default
address of the camera is 169.254.1.1 and the Subnet mask is 255.255.0.0. Different computer OS types all have their own way of doing things
(without question), but they are essentially doing the same stuff, changing the IP address so the web pages are accessible
Screen Shot: Home Page
The Home Page Contains the Admin Login tabs and the Vaddio Technical Support contact information. Both the
Admin and the User may access this page.
.
OneLINK for Precision 60 - Document Number 342-1036 Page 8 of 20
Vaddio OneLINK for Precision 60
Screen Shot: Login
By clicking on the Admin tab, the Admin Login password field appears.
By default, the password for the admin account is: password
Screen Shot: Room Labels
The Room Labels menu allows the Admin to label the company name, room name, room phone and help phone
on a per OneLINK Interface basis. The labels appear on every page at the top/middle of the page. Simply enter
the room information and click Save.
OneLINK for Precision 60 - Document Number 342-1036 Page 9 of 20
Vaddio OneLINK for Precision 60
Screen Shot: Networking (DHCP)
Under the Networking menu tab, the Network Configuration and Network Interfaces are displayed. This is where
the Network administrator assigns either DHCP or a Static address and the associated parameters.
Notes: If the LAN has a DHCP (dynamic host configuration protocol) server, then the IP address, gateway and routing information will
automatically be assigned. The software is defaulted to DHCP and will attempt to dynamically obtain an IP address using DHCP, but it will fall
back to the default address of (169.254.1.1) if no DHCP server can be found.
Screen SHOT: Networking (Static IP Configuration)
If Static IP is used, the IP Address, Subnet Mask and Gateway are manually entered. Click on Save to keep the
Static IP information.
OneLINK for Precision 60 - Document Number 342-1036 Page 10 of 20
A
Vaddio OneLINK for Precision 60
Screen SHOT: Security
The Security menu allows the Admin to set the Admin password. In the future there will be a User access password for camera
control with Vaddio PTZ cameras using the OneLINK Systems. The Guest Access function is also a f uture parameter that is
inactive. There is only one Admin password at any given time. If changes are made, click on Save to store the change (it’s best
to write down the password).
FUTURE
FUTURE
CTIVE
Screen SHOT: Security
After clicking the Edit Password button, an Edit Admin Password pop-up menu will appear. Enter and confirm the
new Admin password and click Save to enter.
OneLINK for Precision 60 - Document Number 342-1036 Page 11 of 20
Vaddio OneLINK for Precision 60
Screen Shot: Diagnostics
Diagnostics menu button will display a set of self-diagnostics. These diagnostics may help the Vaddio techn ical support team
diagnose a problem with the camera
. The controls include Download, Refresh, Clear and Restore.
Screen Shot - Admin Menu - Help
Service/Help information can be found under the Help menu. Support phone numbers and e-mail, manuals, FAQ’s
and System information is listed on support@vaddio.com.
OneLINK for Precision 60 - Document Number 342-1036 Page 12 of 20
Vaddio OneLINK for Precision 60
Screen Shot: System Menu
The System Menu is where the System Info is displayed and Firmware Updates are performed. There will be
firmware updates and upgrades over the life of the OneLINK Interface. The file for the firmware update is chosen
in this menu and the update is started here too. A remote system Reboot and Restore to Factory Presets is also
available.
Screen Shot: System Menu - Firmware Update Confirmation
After the firmware update file has been chosen and Begin Firmware Update is clicked, a confirmation message
pop-up is shown. Click on continue or cancel one the content of the pop-up is understood.
OneLINK for Precision 60 - Document Number 342-1036 Page 13 of 20
Vaddio OneLINK for Precision 60
Screen Shot: System Menu - Restore Factory Settings Confirmation
After clicking on Restore Factory Settings, a confirmation message pop-up is shown. Click on continue or cancel
one the content of the pop-up is understood.
Screen Shot: System Menu - Temperature Fault
With HDBaseT technologies, the transmit side (EZIM on the camera end) can tend to run warm, which is very
normal. If the system detects that the temperature is too high, a temperature fault banner will appear and give
direction to reboot or power cycle the system.
This concludes the Screen Shot Tour for the OneLINK HDMI Interface. The General
Specifications, Pin-outs, Declaration of Compliance and Warranty Statement are to follow
and are as breathtaking and stimulating as one would expect.
OneLINK for Precision 60 - Document Number 342-1036 Page 14 of 20
Vaddio OneLINK for Precision 60
GENERAL SPECIFICATIONS
OneLINK System for Precision 60
Part Numbers
Included cables
Video Support
RS-232 Support Pass-through
Ethernet Support Pass-through
Camera Power Support 12 VDC, 3 Amp at EZIM
Cabling Distances Up to 328’ (100m) over Cat-5e/6
OneLINK Interface Power Supply 48 VDC, 1.36 Amp
Connectors on OneLINK Interface
Connectors on OneLINK EZIM OneLINK Port on Shielded RJ-45F, HDMI Input Receptacle, Ethernet on shielded RJ-45F
OneLINK Interface Dimensions 1.72” (43.7mm) H x 8.375” (212.7mm) W x 6.00” (152.4mm) D
OneLINK EZIM Dimensions 3.861” (98.07mm) H x 4.310” (109.47mm) W x 1.24” (31.5mm) D
OneLINK Interface Weight 1.553 lbs. (703.1g)
OneLINK EZIM Weight: 0.553 lbs. (249.5g)
Operating Temperature/Humidity 0°C (32°F) to 40°C (104°F), 20% to 80% Relative Humidity
Storage Temperature -20°C (-4°F) to +60°C (140°F)
Notes: Specifications and pricing are subject to change without prior notice or obligation.
999-9560-000: OneLINK System for Precision 60 Camera (North America)
999-9560-001: OneLINK System for Precision 60 Camera (International)
One (1) 12” (305mm) HDMI cable(camera side)
One (1) 12” (305mm) Cat-5e Patch Cable (camera side)
One (1) 12” (305mm) Camera power cable(camera side)
One (1) 36” (915mm) Cat-5e Patch Cable (codec side)
One (1) 36” (915mm) HDMI cable (codec side)
HDMI resolutions up to 1080p/60 for Precision 60 camera. The OneLINK architecture will
support up to 2160p/30…for the future.
OneLINK Port on Shielded RJ-45F, HDMI Output Receptacle, Ethernet on shielded RJ-45F
with LEDs, RS-232 on shielded RJ-45 connector, Power in on 5.5mm OD x 2.5mm ID Coaxial
connector (positive Center), IR Forward on 3-pin Phoenix-style connector
with LEDs, RS-232 on shielded RJ-45 connector, Power out on EIAJ-04 connector
APPENDIX 1:CONNECTORS AND SIGNALS
OneLINK HDMI EZIM - RS-232 Control Port RJ-45
PIN# Signal
1) Unused
2) Unused
3) Unused
4) IR GND
5) IR (non-mod)
6) GND
7) TX (to RX of camera)
8) RX (from TX of camera)
OneLINK HDMI Interface - RS-232 Control Port (RJ-45)
PIN# Signal
1) Unused
2) Unused
3) Unused
4) Unused
5) Unused
6) GND
7) RX (from TX of controller)
8) TX (to RX of controller)
OneLINK HDMI Interface - Ethernet Network Port (RJ-45)
PIN# Signal
1) TX+_D1
2) TX-_D1
3) RX+_D2
4) BI+_D3
5) BI-_D3
6) RX-_D2
7) BI+_D4
8) BI-_D4
OneLINK HDMI Interface - IR output on Euro style 3-pin:
PIN# Signal
1) Modulated IR
2) Common Ground
3) Non-modulated IR
12345678
12345678
12345678
Not Used with the Cisco
Precision 60 Camera
1 2 3
OneLINK for Precision 60 - Document Number 342-1036 Page 15 of 20
Vaddio OneLINK for Precision 60
COMPLIANCE AND CEDECLARATION OF CONFORMITY -ONELINKHDMIINTERFACE
Compliance testing was performed to the following regulations:
FCC Part 15 (15.107, 15.109), Subpart B Class A
ICES-003, Issue 5: 2012 Class A
EMC Directive 2004/108/EC Class A
EN 55022: December 2010 Class A
EN 55024: November 2010 Class A
KN22 2008 (CISPR 22: 2006) Class A
KN24 2008 (CISPR 24: 1997 + A1: 2000 + A2: 2002) Class A
IEC 60950-1:2005 (2nd Edition); Am 1:2009 + Am 2:2013
EN 60950-1:2006 + A11:2009 + A1:2010 + A12:2011 + A2:2013 Safety
FCC Part 15 Compliance
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15, Subpart B,
of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment
is operated in a commercial environment. This equipment generates, uses, and can radi ate radio frequency energy and, if not
installed and used in accordance with the instruction manual, may cause harmful interference to radio communications.
Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to
correct the interference at his/her own expense.
Operation is subject to the following two conditions: (1) This device may not cause interference, and (2) This device must accept
any interference including interference that may cause undesired operation of the device.
Changes or modifications not expressly approved by Vaddio can affect emission compliance and could void the user’s authority
to operate this equipment.
ICES-003 Compliance
This digital apparatus does not exceed the Class A limits for radio noise emissions from digital apparat us set out in the Radio
Interference Regulations of the Canadian Department of Communications.
Le présent appareil numérique n’emet pas de bruits radioélectriques dépassant les limites applicables aux appareils numeriques
de la classe A préscrites dans le Règlement sur le brouillage radioélectrique édicte par le ministère d es Communications du
Canada.
European Compliance
This product has been evaluated for Electromagnetic Compatibility under the EMC Directive for Emissions and Immunity and
meets the requirements for a Class A digital device. In a domestic environment this product may cause radio interferenc e in
which case the user may be required to take adequate measures.
Standard(s) To Which Conformity Is Declared:
EMC Directive 2004/108/EC
EN 55022: December 2010 Conducted and Radiated Emissions
EN 55024: November 2010 Immunity
EN 61000-4-2: 1995 + Amendments A1: 1998 + A2: 2001 Electrostatic Discharge
EN 61000-4-3: 2006 + A1: 2008 Radiated Immunity
EN 61000-4-4: 2004 + Corrigendum 2006 Electrical Fast Transients
EN 61000-4-5: 2006 Surge Immunity
EN 61000-4-6: 2009 Conducted Immunity
EN 61000-4-8: 2010 Power Frequency Magnetic Field
EN 61000-4-11: 2004 Voltage Dips, Interrupts and Fluctuations
EN 61000-4-2 Electrostatic Discharge
EN 61000-4-3 Radiated Immunity
EN 61000-4-4 Electrical Fast Transients
EN 61000-4-5 Surge Immunity
EN 61000-4-6 Conducted Immunity
EN 61000-4-8 Power Frequency Magnetic Field
EN 61000-4-11 Voltage Dips, Interrupts and Fluctuations
IEC 60950-1:2005 (2nd Edition); Am 1:2009 + Am 2:2013 Safety
EN 60950-1:2006 + A11:2009 + A1:2010 + A12:2011 + A2:2013 Safety
Safety
OneLINK HDMI Interface
P/N: 998-1105-043
OneLINK for Precision 60 - Document Number 342-1036 Page 16 of 20
Vaddio OneLINK for Precision 60
COMPLIANCE AND CEDECLARATION OF CONFORMITY -ONELINKHDMIEZIM
Compliance testing was performed to the following regulations:
FCC Part 15 (15.107, 15.109), Subpart B Class A
ICES-003, Issue 5: 2012 Class A
EMC Directive 2004/108/EC Class A
EN 55022: December 2010 Class A
EN 55024: November 2010 Class A
KN22 2008 (CISPR 22: 2006) Class A
KN24 2008 (CISPR 24: 1997 + A1: 2000 + A2: 2002) Class A
IEC 60950-1:2005 (2nd Edition); Am 1:2009 + Am 2:2013
EN 60950-1:2006 + A11:2009 + A1:2010 + A12:2011 + A2:2013 Safety
FCC Part 15 Compliance
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15, Subpart B,
of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment
is operated in a commercial environment. This equipment generates, uses, and can radi ate radio frequency energy and, if not
installed and used in accordance with the instruction manual, may cause harmful interference to radio communications.
Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to
correct the interference at his/her own expense.
Operation is subject to the following two conditions: (1) This device may not cause interference, and (2) This device must accept
any interference including interference that may cause unde s ired operation of the device.
Changes or modifications not expressly approved by Vaddio can affect emission compliance and could void the user’s authority
to operate this equipment.
ICES-003 Compliance
This digital apparatus does not exceed the Class A limits for radio noise emissions from digital apparat us set out in the Radio
Interference Regulations of the Canadian Department of Communications.
Le présent appareil numérique n’emet pas de bruits radioélectriques dépassant les limites applicables aux appareils numeriques
de la classe A préscrites dans le Règlement sur le brouillage radioélectrique édicte par le ministère d es Communications du
Canada.
European Compliance
This product has been evaluated for Electromagnetic Compatibility under the EMC Directive for Emissions and Immunity and
meets the requirements for a Class A digital device. In a domestic environment this product may cause radio interference in
which case the user may be required to take adequate measures.
Standard(s) To Which Conformity Is Declared:
EMC Directive 2004/108/EC
EN 55022: December 2010 Conducted and Radiated Emissions
EN 55024: November 2010 Immunity
EN 61000-4-2: 1995 + Amendments A1: 1998 + A2: 2001 Electrostatic Discharge
EN 61000-4-3: 2006 + A1: 2008 Radiated Immunity
EN 61000-4-4: 2004 + Corrigendum 2006 Electrical Fast Transients
EN 61000-4-5: 2006 Surge Immunity
EN 61000-4-6: 2009 Conducted Immunity
EN 61000-4-8: 2010 Power Frequency Magnetic Field
EN 61000-4-11: 2004 Voltage Dips, Interrupts and Fluctuations
EN 61000-4-2 Electrostatic Discharge
EN 61000-4-3 Radiated Immunity
EN 61000-4-4 Electrical Fast Transients
EN 61000-4-5 Surge Immunity
EN 61000-4-6 Conducted Immunity
EN 61000-4-8 Power Frequency Magnetic Field
EN 61000-4-11 Voltage Dips, Interrupts and Fluctuations
IEC 60950-1:2005 (2nd Edition); Am 1:2009 + Am 2:2013 Safety
EN 60950-1:2006 + A11:2009 + A1:2010 + A12:2011 + A2:2013 Safety
OneLINK HDMI EZIM
Safety
P/N: 998-6700-043
OneLINK for Precision 60 - Document Number 342-1036 Page 17 of 20
Vaddio OneLINK for Precision 60
WARRANTY INFORMATION
(See Vaddio Warranty, Service and Return Policies posted on vaddio.com for complete details):
Hardware* Warranty: Two (2) year limited warranty on all parts and labor for Vaddio manufactured products. Vaddio warrants
its manufactured products against defects in materials and workmanship for a period of two years from the day of purchase, to
the original purchaser, if Vaddio receives notice of such defects during the warranty. Vaddio, at its option, will repair or replace
products that prove to be defective. Vaddio manufactures its hardware products from parts and components that are ne w or
equivalent to new in accordance with industry standard practices.
Exclusions: The above warranty shall not apply to defects resulting from improper or inadequate maintenance by the customer,
customers applied software or interfacing, unauthorized modifications or misuse, mish andling, operation outside the normal
environmental specifications for the product, use of the incorrect power supply, modified power supply or improper site operation
and maintenance. OEM and Special Order products manufactured by other companies are e xcluded and are covered by the
manufacturer’s warranty.
Vaddio Customer Service: Vaddio will test, repair, or replace the product or products without charge if the unit is under
warranty. If the product is out of warranty, Vaddio will test then repair the product or products. The cost of parts and labor
charge will be estimated by a technician and confirmed by the customer prior to repair. All components must be returned for
testing as a complete unit. Vaddio will not accept responsibility for shipment after it has left the premises.
Vaddio Technical Support: Vaddio technicians will determine and discuss with the customer the criteria for repair costs and/or
replacement. Vaddio Technical Support can be contacted through one of the following resources: e-mail support at
support@vaddio.com or online at vaddio.com.
Return Material Authorization (RMA) Number: Before returning a product for repair or replacement request an RMA from
Vaddio’s technical support. Provide the technician with a return phone number, e-mail address, shipping address, product serial
numbers and original purchase order number. Describe the reas on for r epairs or returns as well as the date of purch ase. See
the General RMA Terms and Procedures section for more information. RMA’s are valid for 30 days and will be issued to Vaddio
dealers only. End users must return products through Vaddio dealers. Include the assigned RMA number in all correspondence
with Vaddio. Write the assigned RMA number clearly on the shipping label of the box when returning the product. All products
returned for credit are subject to a restocking charge without exception. Special Order product are not returnable.
Voided Warranty: The warranty does not apply if the original serial number has be en removed or if the product has been
disassembled or damaged through misuse, accident, modifications, us e of incorrect power supply, use of a modified power
supply or unauthorized repair.
Shipping and Handling: Vaddio will not pay for inbound shipping transportation or insurance charges or accept any
responsibility for laws and ordinances from inbound transit. Vaddio will pay for outbound shipping, transportation, and insurance
charges for all items under warranty but will not assume responsibility for loss and/or damage by the outbound freight carrier. If
the return shipment appears damaged, retain the original boxes and p acking material for inspection by the carrier. Contact
your carrier immediately.
Products not under Warranty: Payment arrangements are required before outbound shipment for all out of warranty products.
Other General Information:
Care and Cleaning
Do not attempt to take this product apart at any time. There are no user-serviceable components inside.
Do not spill liquids in the product
Keep this device away from food and liquid
For smears or smudges on the product, wipe with a clean, soft cloth
Do not use any abrasive chemicals.
Operating and Storage Conditions:
Do not operate or store the device under the following conditions:
Temperatures above 40°C (104°F) or temperatures below 0°C (32°F)
High humi dit y, condensing or wet environments
In inclement weather or in swimming pools
Dry environments with an excess of static discharge
Under severe vibration
In, above or below inclement weather
Haunted locations (ghosting video may result)
In outer space (without star ship)
OneLINK for Precision 60 - Document Number 342-1036 Page 18 of 20
Vaddio OneLINK for Precision 60
Notes:
OneLINK for Precision 60 - Document Number 342-1036 Page 19 of 20
Vaddio OneLINK for Precision 60
2015 Vaddio - All Rights Reserved. Reproduction in whole or in part without written permission is prohibited. Specifications and pricing are subject to
change without notice. Vaddio, OneLINK, EZIM, EZCamera and ProductionVIEW are trademarks of Vaddio. All other trademarks are property of their
respective owners. Document Number 342-1036 Rev A, SD: 69193.3
OneLINK for Precision 60 - Document Number 342-1036Page 20 of 20