Vacon x series Catalog Page

WE ARE DRIVES
®
vacon
x series
rugged drives for the real world
61
x series
®
f2
f1
f0
the toughest ac drives on the planet!
The Vacon X Series Drives are designed for the REAL world - a world that is not gentle or forgiving to electronic devices. They have been designed to keep driving in harsh environments and are built from the ground up to survive hostile conditions and still be simple to use. They are built to be mounted where the work is, not hidden in another enclosure or room that adds costs and space.
®
x series
robust and reliable
The same enclosures that can survive in the harsh industrial world makes them ideal when cleanliness is extremely important, such as the Food and Beverage industry where high pressure washings are needed on a regular basis. The Vacon X Series drives, through 100 HP, exceed the specifications of their rated UL Type 4X / IP66 Indoor and Outdoor rated enclosures, each being able to withstand high pressure washdown of 1000 PSI from 12” away. The Vacon X Series drives are also packed with advanced control and operation features that make them the best choice for ever ything from simple, stand­alone applications to advanced system-level controls.
simple and flexible
The Vacon X Series drives also boast the easiest programming and operation in the industry. The
62
bright, clear, backlit display provides an easy to read and customizable view for operation and programming. The Vacon X Series keypad has large, well marked buttons to control all aspects of the drive operation and programming.
The Vacon X4 has the toughness and features to handle most industrial jobs with ease. If the application is more unique, the X5 accepts option boards, has a USB interface, fully coated PC boards for added protection and other advanced features such as a real-time-clock.
A tough enclosure, an easy to read display, simple programming and the confidence of knowing you can mount the drive almost any where make the Vacon X Series the only choice for the most demanding environments.
f3
f5
f4
new to vacon x series
230vac single phase input
The VACON X4 and VACON X5 now feature a best in class, out-of-the-box, single phase 230VAC input product offering with standard ouput powers of 5HP, 10HP and 15HP (230V 3-Phase AC). These new offerings provide all the benefits of the VACON X Series family including the most robust UL Type 4X, Indoor/Outdoor, rated enclosure with the ease of use and flexibility you’ve come to know and trust.
new enclosure rating for frame 5
Just when you thought the VACON X Series couldn’t possibly stand up to any more of a beating, we go ahead and make the Frame 5 even more robust. From 125HP through 200HP, the VACON X Series can now be placed outside in the elements with the new UL Type 3R, Indoor/ Outdoor rating. For the first time, EVERY VACON X Series can be placed outside in the elements, allowing for even greater mounting flexibility without having to spend even one cent more on installation costs.
vacon x4 / x5
Features Description Benefits
Robust Enclosure The VACON X Series features a best in class
UL Type 4X, Indoor/Outdoor certified enclosure through 100HP
Integrated Brake Resistor Each VACON X Ser ies includes a Brake resistor
allow ing it to better handle high iner tial loads and warm up in cold conditions
Built-in Sequencer The VACON X Series features a built-in multi-
step sequencer that can replace a small PLC in many applications
what’s in it for you
•ReducedInstallationCost
•HighReliability
•ReducedInstallationCosts
•MountinLowTemperatures
•Reducedinvestmentcosts
•Flexibleapplicationprogramming
x series
®
63
standard vacon x series features
toughest packaging
The VACON X Series is the toughest drive on the market today. Featuring an incredibly robust design with (low failure rate), the VACON X Series can truely be mounted where it is needed the most.
Thick injected foam and metal covers protect against bumps and
misuse
Withstands 1,000 PSI washdown from 6 inches away on models though 30 HP
Withstands 1000 PSI washdown from 12 inches away on models through 100HP
Mounts close to the motor to eliminate long motor lead problems
indoor or outdoor
Each drive in the VACON X Series features a built-in braking resistor that not only allows the VACON X Series to handle higher inertial
loads out of the box, but allows it to warm itself up in even the coldest
conditions. Add to this the standard UL-approved Outdoor Rating
found on every frame size and you have a one-two punch that just can’t be beat.
UL Type 4X / IP66 Indoor and Outdoor rated enclosures through 100 HP
UL Type 3R / IP55 Indoor and Outdoor rated enclosures for 125 HP and above
Dynamic Braking resistors included as standard
ARCTIC Mode maintains safe operating temperature in cold
locations
easy to use
The VACON X Series features a user-friendly keypad which makes
operation simple. The easy-to-read display communicates operational status information as well as parameter names and settings in a clear, plain text, format making navigation and programming easier than ever.
Simple intuitive programming with color coded buttons
Multi-language display – no codes to learn
Two parameter levels eases simple application programming
Application Macros make set-up a breeze
®
x series
64
versatile programming
Not only does the VACON X Series feature a robust and reliable
enclosure, it also brings with it a level of versatility to meet almost
any application requirements. By including features such as Modbus RTU, a multi-step PLC-like sequencer and plenty of dedicated and programmable I/O, the VACON X Series helps to reduce the overall
system investment costs.
Operate from keypad, remote I/O, fieldbus communications or any combination
Built-in 9-step PLC functions (25-step with X5)
Modbus RTU as standard fieldbus communications
advanced vacon x5 features
integrated usb port
The VACON X5 control platform includes a USB port as standard for
functions like parameter saving, firmware updating and using the built-in data-logger function.
Parameter Save / Recall
Save parameter set to USB stick and upload to another drive
Stored data easily opened with Microsoft Excel
Ability to define custom file name (numbers or text)
Easy firmware upgrades using standard USB memory stick
Collect real time data and event logs
option card support
In an ever changing world, a drive must be ready to support newer technologies as well as maintain a level of compatibility with
established technology. The VACON X5 easily walks this line through
the addition of support for several communications option cards that include built-in 115V I/O and an encoder input for high demand applications.
DeviceNet, Ethernet IP, Profibus and Modbus TCP option cards are available to supplement the built in Modbus RTU
All option cards include five channels of 115VAC control inputs
and offer a shaft mounted encoder interface
An option card is available with a dedicated encoder interface
real-time clock
By adding a real-time clock to the VACON X5, the information received
from the drive is not only much more useful, but many of the functions in the drive are further expanded for greater time based control.
Time and date stamped Fault Information
Keeper Function — logs time-based data from external or
internal signals
Data read via serial communication or transferred to USB Memory Stick
Control operation based on time-of-day. Separate weekday and
weekend settings available
Signals an event via text on the display or contact closure,
independent of drive operation
x series
®
enhanced program sequencer
The VACON X5 features an enhanced 25-step programmable
sequencer that unlocks even more PLC-like capabilities than the
9-step sequencer of the VACON X4. This allows an unprecedented
level of built-in control that helps to reduce investment costs and increase efficiency.
Create up to 4 independant groups of steps for ultimate flexibility
New loop and branch capabilities available
Real Time Clock — time-of-day (TOD) enable function, allows
programmed operation to specific periods of the day or week
65
x-series i/o
Terminal Description
FWD Run Forward Selection
REV Run Reverse Selection
R/J Run/Jog Selection
DI1 Digital Input 1
DI2 Digital Input 2
DI3 Digital Input 3
DI4 Digital Input 4
DI5 Digital Input 5
MOL External Motor Overload
+24V 24V Bus for Digital Inputs
+10V 10V Bus for Analog Inputs
Vi n1 Analog Input (Voltage)
Acom Analog Common (Ground)
Cin+ Current Input
Cin- Current Input
Imet Analog Output (Current)
product range
vacon x series 115 vac 1-ph
Product Code Motor Shaft Power and Current
Vacon X4 Vacon X5
--- VACONX5C1S010C 0.5 0.37 2.2 1 0.75 4.2 F1A
VACONX4C1S010C VACONX5C1S010C09 0.5 0.37 2.2 1 0.75 4.2 F0
High Overload (150%) Low Overload (120%)
HP kW Amps HP kW Amps
Terminal Description
Acom Analog Common (Ground)
Vmet Analog Output (Voltage)
NO1 Relay 1 Normally Open
RC1 Relay 1 Common
NC1 Relay 1 Normally Closed
NO2 Relay 2 Normally Open
RC2 Relay 2 Common
NC2 Relay 2 Normally Closed
Dcom Digital Common (Ground)
EN Drive Enable Terminal
+24V 24V Bus for Digital Inputs
+24V 24V Bus for Digital Inputs
Dcom Digital Common (Ground)
DO1 Digital Output 1
DO2 Digital Output 2
DOP Pulse Train Digital Output
Frame
Size
Dimensions
W x H x D (mm)
W x H x D (in)
221 x 306 x 216
8.72 x 12.01 x 8.49
165 x 241 x 155
6.5 x 9.47 x 6.08
Weight (kg)
Weight (lbs)
6.35
14
3.85
8.5
vacon x series 200-230 vac 1-ph
Product Code Motor Shaft Power and Current
Vacon X4 Vacon X5
--- VACONX5C2S050C 3 2.2 9.6 5 4 15.2 F1A
--- VACONX5C2S100C 7.5 5.5 22 10 7.5 28 F2A
VACONX4C2S050C --- 3 2.2 9.6 5 4 15.2 F1
VACONX4C2S100C --- 7.5 5.5 22 10 7.5 28 F2
VACONX4C2S150C VACONX5C2S150C 10 7.5 28 15 11 42 F3
®
High Overload (150%) Low Overload (120%)
HP kW Amps HP kW Amps
Frame
Size
Dimensions
W x H x D (mm)
W x H x D (in)
221 x 306 x 216
8.72 x 12.01 x 8.49
273 x 442 x 251
10.75 x 17.38 x 9.89
221 x 306 x 166
8.72 x 12.01 x 6.51
273 x 442 x 201
10.75 x 17.38 x 7.91
286 x 513 x 314
11.19 x 20.19 x 11.73
Weight (kg)
Weight (lbs)
6.35
14
13.38
29.5
6.35
14
13.38
29.5
22.68
50
vacon x series 200-230 vac 3-ph
x series
VACONX4C20010C VACONX5C20010C09 0.5 0.37 2.2 1 0.75 4.2 VACONX4C20020C VACONX5C20020C09 1 0.75 4.2 2 1.5 6.8 VACONX4C20030C VACONX5C20030C09 2 1.5 6.8 3 2.2 9.6 VACONX4C20050C VACONX5C20050C09 3 2.2 9.6 5 4 15.2
VACONX4C20075C VACONX5C20075C09 5 4 15.2 7.5 5.5 22 VACONX4C20100C VACONX5C20100C09 7.5 5.5 22 10 7.5 28 VACONX4C20150C VACONX5C20150C09 10 7.5 28 15 11 42 VACONX4C20200C VACONX5C20200C 15 11 42 20 15 54 VACONX4C20250C VACONX5C20250C 20 15 54 25 18.5 68
Product Code Motor Shaft Power and Current
Vacon X4 Vacon X5
--- VACONX5C20010C 0.5 0.37 2.2 1 0.75 4.2
--- VACONX5C20020C 1 0.75 4.2 2 1.5 6.8
--- VACONX5C20030C 2 1.5 6.8 3 2.2 9.6
--- VACONX5C20050C 3 2.2 9.6 5 4 15.2
--- VACONX5C20075C 5 4 15.2 7.5 5.5 22
--- VACONX5C20100C 7.5 5.5 22 10 7.5 28
--- VACONX5C20150C 10 7.5 28 15 11 42
High Overload (150%) Low Overload (120%)
HP kW Amps HP kW Amps
Frame
Size
F1A
F2A
F0
F1
F2
F3
Dimensions
W x H x D (mm)
W x H x D (in)
221 x 306 x 216
8.72 x 12.01 x 8.49
273 x 442 x 251
10.75 x 17.38 x 9.89
165 x 241 x 155
6.5 x 9.47 x 6.08
221 x 306 x 166
8.72 x 12.01 x 6.51
273 x 442 x 201
10.75 x 17.38 x 7.91
286 x 513 x 314
11.19 x 20.19 x 11.73
Weight (kg)
Weight (lbs)
6.35
14
13.38
29.5
3.85
8.5
6.35
14
13.38
29.5
22.68
50
66
vacon x series 380-480 vac 3-ph
Product Code Motor Shaft Power and Current
Vacon X4 Vacon X5
--- VACONX5C40010C 0.5 0.37 1.1 1 0.75 2.1
--- VACONX5C40020C 1 0.75 2.1 2 1.5 3.4
--- VACONX5C40030C 2 1.5 3.4 3 2.2 4.8
--- VACONX5C40050C 3 2.2 4.8 5 4 7.6
--- VACONX5C40075C 5 4 7.6 7.5 5.5 11
--- VACONX5C40100C 7.5 5.5 11 10 7.5 14
--- VACONX5C40150C 10 7.5 14 15 11 21
--- VACONX5C40200C 15 11 21 20 15 27
--- VACONX5C40250C 20 15 27 25 18.5 34
--- VACONX5C40300C 25 18.5 34 30 22 40 VACONX4C40010C VACONX5C40010C09 0.5 0.37 1.1 1 0.75 2.1 VACONX4C40020C VACONX5C40020C09 1 0.75 2.1 2 1.5 3.4 VACONX4C40030C VACONX5C40030C09 2 1.5 3.4 3 2.2 4.8 VACONX4C40050C VACONX5C40050C09 3 2.2 4.8 5 4 7.6 VACONX4C40075C VACONX5C40075C09 5 4 7.6 7.5 5.5 11 VACONX4C40100C VACONX5C40100C09 7.5 5.5 11 10 7.5 14 VACONX4C40150C VACONX5C40150C09 10 7.5 14 15 11 21 VACONX4C40200C VACONX5C40200C09 15 11 21 20 15 27 VACONX4C40250C VACONX5C40250C09 20 15 27 25 18.5 34 VACONX4C40300C VACONX5C40300C09 25 18.5 34 30 22 40 VACONX4C40400C VACONX5C40400C 30 22 40 40 30 52 VACONX4C40500C VACONX5C40500C 40 30 52 50 37 65 VACONX4C40600C VACONX5C40600C 50 37 65 60 45 77 VACONX4C40750C VACONX5C40750C 60 45 77 75 55 96 VACONX4C41000C VACONX5C41000C 75 55 96 100 75 124 VACONX4C41250K VACONX5C41250K 100 75 124 125 90 156 VACONX4C41500K VACONX5C41500K 125 90 156 150 110 180 VACONX4C42000K VACONX5C42000K 150 110 180 200 132 240
High Overload (150%) Low Overload (120%)
HP kW Amps HP kW Amps
Frame
Size
F1A
F2A
F0
F1
F2
F3
F4
F5
product range
Dimensions
W x H x D (mm)
W x H x D (in)
221 x 306 x 216
8.72 x 12.01 x 8.49
273 x 442 x 251
10.75 x 17.38 x 9.89
165 x 241 x 155
6.5 x 9.47 x 6.08
221 x 306 x 166
8.72 x 12.01 x 6.51
273 x 442 x 201
10.75 x 17.38 x 7.91
286 x 513 x 314
11.19 x 20.19 x 11.73
326 x 745 x 351
12.84 x 29.35 x 13.8
461 x 1334 x 429
18.14 x 52.5 x 16.88
Weight (kg)
Weight (lbs)
6.35
14
13.38
29.5
3.85
8.5
6.35
14
13.38
29.5
22.68
50
43.1
95
138.35
305
vacon x series 575 vac 3-ph
Product Code Motor Shaft Power and Current
Vacon X4 Vacon X5
--- VACONX5C50010C 0.5 0.37 0.9 1 0.75 1.7
--- VACONX5C50020C 1 0.75 1.7 2 1.5 2.7
--- VACONX5C50030C 2 1.5 2.7 3 2.2 3.9
--- VACONX5C50050C 3 2.2 3.9 5 4 6.1
--- VACONX5C50075C 5 4 6.1 7.5 5.5 9
--- VACONX5C50100C 7.5 5.5 9 10 7.5 11
--- VACONX5C50150C 10 7.5 11 15 11 17
--- VACONX5C50200C 15 11 17 20 15 22
--- VACONX5C50250C 20 15 22 25 18.5 27
--- VACONX5C50300C 25 18.5 27 30 22 32 VACONX4C50010C VACONX5C50010C09 0.5 0.37 0.9 1 0.75 1.7 VACONX4C50020C VACONX5C50020C09 1 0.75 1.7 2 1.5 2.7 VACONX4C50030C VACONX5C50030C09 2 1.5 2.7 3 2.2 3.9 VACONX4C50050C VACONX5C50050C09 3 2.2 3.9 5 4 6.1 VACONX4C50075C VACONX5C50075C09 5 4 6.1 7.5 5.5 9 VACONX4C50100C VACONX5C50100C09 7.5 5.5 9 10 7.5 11 VACONX4C50150C VACONX5C50150C09 10 7.5 11 15 11 17 VACONX4C50200C VACONX5C50200C09 15 11 17 20 15 22 VACONX4C50250C VACONX5C50250C09 20 15 22 25 18.5 27 VACONX4C50300C VACONX5C50300C09 25 18.5 27 30 22 32 VACONX4C50400C VACONX5C50400C 30 22 32 40 30 41
VACONX4C50500C VACONX5C50500C 40 30 41 50 37 52 VACONX4C50600C VACONX5C50600C 50 37 52 60 45 62
VACONX4C50750C VACONX5C50750C 60 45 62 75 55 77 VACONX4C51000C VACONX5C51000C 75 55 77 100 75 99 VACONX4C51250K VACONX5C51250K 100 75 99 125 90 125 VACONX4C51500K VACONX5C51500K 125 90 125 150 110 144 VACONX4C52000K VACONX5C52000K 150 110 144 200 132 192
High Overload (150%) Low Overload (120%)
HP kW Amps HP kW Amps
Frame
Size
F1A
F2A
F1
F2
F3
F4
F5
Dimensions
W x H x D (mm)
W x H x D (in)
221 x 306 x 216
8.72 x 12.01 x 8.49
273 x 442 x 251
10.75 x 17.38 x 9.89
221 x 306 x 166
8.72 x 12.01 x 6.51
273 x 442 x 201
10.75 x 17.38 x 7.91
286 x 513 x 314
11.19 x 20.19 x 11.73
326 x 745 x 351
12.84 x 29.35 x 13.8
461 x 1334 x 429
18.14 x 52.5 x 16.88
Weight (kg)
Weight (lbs)
6.35
14
13.38
29.5
6.35
14
13.38
29.5
22.68
50
43.1
95
138.35
305
x series
®
67
vacon x series options
OPTION ORDER TYPECODE NOTE
DeviceNet Option Card X5DNET01
Ethernet IP Option Card X5EIP01
ModBus TCP/IP Option Card X5MBTCP01
ProfiBus Option Card X5PROF01
115 Vac and Encoder Feedback Option Card
Remote Keypad for Panel Mount Drives XRKPM
Remote Keypad for Wall Mount Drives XRKWM VACON X4 and X5 - Frames 0-2
Remote Keypad Mounting Kit XRKMK VACON X4 and X5 - Frames 3-5
DB Connection Kit XDBKITS4 VACON X4 and X5 - Frame 4 Only
DB Connection Kit - Fr ame 5 XDBKITS5 VACON X4 and X5 - Fr ame 4 Only
X5OPT01
VACON X5 Only. Models with “09” suffix will not accept option cards
Includes 12’ Ribbon Cable VACON X4 and X5 - Frames 0-2
vacon x4 and vacon x5 specifications
Environmental
Electrical
®
x series
Control Features
Operating temperature -10°Cto+40°C (14°F to 104°F)
Storage temperature -20°C to 65°C (-4°F to 149°F)
Humidity 0% to 95% non-condensing
Altitude 1,000 m (3,300 ft) without derating
Maximum vibration Per EN50178: Frame Size 0 and 1 5G
Acoustic noise 80 dba sound power at 1 m (3 ft) Cooling 1 - 5 HP models: Natural convection
Protection Level
Agency approvals UL, cUL, CE
Input voltage
Line frequency 50/60Hz+/-2Hz
Source kVA (maximum) 10 times the unit rated kVA (65kA maximum) DC bus voltage for:
Overvoltage trip Dynamic brake activation Normal undervoltage (UV) trip
Control system
Output voltage 0 to 100% of line voltage, 3 phase
Overload capacity
Frequency output Range:0.1–400Hz;Stability:0.1Hz,0.1%analogover24hours+/-10°C
DC holding/injection braking
Current limit Four-quadrant adjustable from 5 to 150%
Speed ramps Primary and alternate adjustable from 0.1 to 3200.0 seconds
Voltage boost Adjustable fixed boost or adjustable auto boost
Voltage characteristic V/Hz - Linear, pump, fan or 2-piece linear; Sensorless Vector
Timed overload Adjustable inverse time trip (shear pin, 30 sec, 60 sec, 5 minutes) for standard or inverter-duty motors
Protective features
Program Sequence Controller
PI and PID Feedback
7.5 - 200 HP: Forced air (temperature controlled external fan) 1 – 100 HP models: UL Type 4X / IP66 Indoor or Outdoor Use (1 – 30 HP models: 1,000 psi water spray at 6 inches) 125 – 200 HP models: UL Type 12 / IP55
115Vac1phase,+/-15% 1HP 200-230Vac,3phase,+/-15% 1-25HP 380-460Vac,3phase,+/-15% 1-200HP 575Vac,3phase,+/-15% 1-200HP
115 Vac models 406 Vdc 388 Vdc 199 Vdc V/Hz or Sensorless Vector Control (SVC) Carrier frequency = 1 to 16 kHz programmable
120% of rated RMS current for 60 seconds (Normal Duty rating) 150% of rated RMS current for 60 seconds (Heavy Duty rating)
At start, stop, by frequency with adjustable current level and time or continuous DC injection by digital input
Overcurrent, Overvoltage fault, ground fault, short circuit, Dynamic Brake overload, drive tempera­ture, power wiring fault. Drive-timed overload, input voltage quality, overvoltage ridethrough
X4: 9-step, PLC-type functionality to control speed, direction and ramp times based on time, analog input, digital input or pulse count. X5: 25-step, PLC-type functionality that can control speed, direction and ramps based on time, analog input,digital input, or pulse input. Conditional branching, addressable outputs and real time operations possible.
X4: PI Process control available with the use of a customer supplied transducer, either 0-10Vdc, 4-20mA or optical encoder input to the drive. X5: Process control available with the use of a customer supplied transducer, either 0-10Vdc, 4-20mA or optical encoder input to the drive. Includes an optional sleep mode, activated when the loop is satisfied.
230 Vac models 406 Vdc 388 Vdc 199 Vdc
460 Vac models 814 Vdc 776 Vdc 397 Vdc
575 Vac models 1017 Vdc 970 Vdc 497 Vdc
68
Loading...