SW Series II
There Are Some Things You Can Always Depend On...
SW Series II
85% AFUE Oil Fired Hot Water Boiler
• Side Wall Vent Oil Boiler with or without Tankless Water Heater,
available in 3 sizes from 91 MBH to 175 MBH.
• Dependable Cast Iron Heat Exchanger with Cast Iron Push Nipples.
The Sections and Push Nipples expand at the same rate when
heated. By using similar materials instead of less expensive gaskets
the boiler maintains a water tight seal over time.
• Honeywell High Limit and Circulator Relay Control.
- Digital temperature display and diagnostics.
- Less Coil: Control monitors water temperature and delays the burner
starting until any residual heat has been transferred. Thermal purge
logic measures rate of temperature change inside the boiler and delays
burner ring accordingly. This maximizes efciency by turning on the
burner only when needed.
- With Coil: The Boiler utilizes a Honeywell non-thermal purge High Limit,
Low Limit and Circulator Relay control.
• Direct Exhaust Vent Pipe Kits and Termination Kits (Sold Separately).
• Optional Tankless Heater Coil.
• Textured paint Jacket.
• Limited Lifetime Warranty (Residential Applications).
• Made in the U.S.A.
Utica SW Series II Residential Oil Fired Water Boiler
(1)
(4)
Tankless Heater Number
(Front of Jacket to Center
Line of Flue Outlet)
Dimensional Diagram Model
SW3065 0.65 91 78 68 85.0%
SW4100 1.00 140 120 104
SW5125 1.25 175 150 130
Front View
(1) AHRI burner capacity is based on an oil heating value of 140,000 Btu/gal and with 13% CO2.
(2) Net AHRI Water Ratings shown are based on a piping and pickup allowance of 1.15.
(3) Consult manufacturer before selecting boiler for installations having unusual piping and pickup requirements, such as intermittent system operation, extensive piping.
(4) For forced hot water heating systems where boiler and all piping are within the area to be heated, select boiler on basis of its Heating Capacity.
General Information (See Installation, Operation and Maintenance Manual for complete instructions)
Clearances
(5) Required
distances
measured from
boiler.
(6) Service,
proper operation
clearence
recommendation.
*For Alcove
installation.
Connections
(All Models)
Electrical 120 Volts AC, 60 hertz, 1 phase, Less than 12 amps (15 amp circuit recommended).
Tankless
Heater
Capacities
Side View
Dimensions/
Weights
Standard
Equipment
Options
AHRI Oil Burner Input
(1)
G.P.H. MBH
Top
Right Side 0” (0mm)
Left Side 0” (0mm)
Front 24” (610 mm)*
Back 6” (152 mm) 6” (152 mm)
Flue Connector 2” (50.8 mm)
Supply Tapping - 2”, Return Tapping 1-1/2” NPT, Oil Line 3/8” O.D. copper tubing for runs of 50 feet or
less, and ½” O.D. for longer runs.
Model
SW3065 0.65 P3 Available on Request 10.5
SW4100 1.00 T3 3-1/4 13.5
SW5125 1.25 T4 3-1/4 16.5
No. of
Sec.
3 17-7/8” 11-1/4” 4” 561 lbs.
4 21-1/2” 12-5/8” 4” 690 lbs.
5 25-1/8” 14-1/4” 4” 819 lbs.
Boiler Controls: Primary Control, High Limit and Circulator Control.
Heat Exchanger: Cast Iron Heat Exchanger with Cast Iron Push Nipples. Swing out Burner Door.
Combustion: Oil Burner, Target Wall/Liner.
Electrical: Wiring Harness, Burner Electrical Disconnect.
Other: Crated Boiler, Flush Jacket, Circulator- 1¼”, Supply Tapping-2”, Return Tapping-1 1/4”, Temperature
Pressure Gauge, Safety Relief Valve, Drain Valve.
For Tankless Heater Units add Tankless Hot Water Coil and Combination High Limit/Low Limit and Circulator
Control.
Taco, Grundfos or Less Pump; Tankless Coil; Side Wall Direct Exhaust (Side Wall Vent Kit sold
separately).
Input Rate
G.P.H.
A
(Depth of Flush
Jacket)
Heating
Capacity
(4)
MBH
Combustible Materials
(Required)
0” (0mm)
B
(5)
Net AHRI
Ratings
(2) (4)
Water MBH
Servicing
(Recommended)
24” (610 mm)
6” (152 mm)
10” (254 mm)
24” (610 mm)
9” (228.6 mm)
Tankless Heater
Capacity
Intermittent Draw
G.P.M.
C
(Flue Outlet
Diameter)
AFUE %
85.0%
85.0%
(6)
Boiler Water
Content
(Gallons)
Weight
Contractor
Assistance: 800.325.5479
Certications
Tested for 75 psi ASME
Working Pressure
Utica, New York 13504
tel: 315.797.1310
www.uticaboilers.com
PN 240009799 Rev. 12/14All ratings and specications subject to change.