Utica Boilers SVB Series II Brochure

SVB Series II
There Are Some Things You Can Always Depend On...
SVB
Up to 84.4% AFUE Gas Fired Hot Water Boiler
Available in 6 sizes from 42 MBH to 225 MBH.
Dependable Cast Iron Heat Exchanger with Cast Iron Push Nipples.
The Sections and Push Nipples expand at the same rate when heated. By using similar materials instead of less expensive gaskets the boiler maintains a water tight seal over time.
Honeywell High Limit/Electronic Ignition Control.
- Recessed under the boiler’s protective jacket
- Digital temperature display and diagnostics
- Plug in connection for the inducer fan
- Plug in connection for the system pump
Control monitors the water temperature and delays the burner
starting until residual heat has been transferred. This maximizes efciency by turning on the burner only when needed.
Induced Draft Fan - allows ue gases to be pulled through the boiler
and exhausted through a chimney or side-wall vent.
Textured paint Jacket. Small compact design is ideal for low
clearance installations.
Limited Lifetime Warranty (Residential Applications)
Made in the USA
Utica SVB Series II Gas Fired Hot Water Boiler
Dimensional
Right Side
29"
Diagram
Front
Left Side
Control Panel
(Internally Located)
231/4"
3"
Model
Input Rate
(MBH)
SVB-2 42.5 36 31 4” 3” 84.4% SVB-3 75 63 55 4” 3” 83.4% SVB-4 112.5 94 82 4” 3” 83.0% SVB-5 150 125 109 4” 3” 82.7% SVB-6 187.5 155 135 4” 4” 82.3% SVB-7 225 186 162 4” 4” 82.0%
1) 1,000 Btuh = British Thermal Unit Per Hour. Boilers are equipped for altitudes up to 2,000 feet only. For altitudes above 2,000 feet, ratings should be reduced at the rate of 4% for each 1,000 feet above sea level. Heating Capacity based on D.O.E. (Department of Energy) test procedure.
2) Net AHRI Water Ratings indicate amount of remaining heat input that can be used to heat the radiation or terminal units. Net AHRI Ratings shown are based on an allowance of 1.15. Selection of boiler size should be based upon “Net AHRI Rating” being equal to or greater than calculated heat loss of building. Manufacturer should be consulted before selecting a boiler for installations having unusual piping and pickup requirements.
(3) Boiler is provided with a 3” x 4” increaser for chimney vent applications. This does not infer that the connection to the chimney will always be 4”. Please refer to IOM, National Fuel Gas Code, ANSI Z223.1/NFPA54, or applicable provisions of the local building codes for details concerning proper chimney connections.
General Information (See Installation, Operation and Maintenance Manual for complete instructions)
Clearances
(4) Required
distances
measured from boiler.
*Denition of Alcove is three
sided space
with no wall in front of boiler.
ANSI standard
for alcove is 18 inches from appliance to leading edge of
side walls as
shown in IOM.
Connections (All Models)
Electrical 120 Volts AC, 60 hertz, 1 phase, Less than 12 amps (15 amp circuit recommended) Water
Content
Dimensions/ Weights
Standard
Equipment
Options
Certications
Top
Rear 6” (152 mm)
Control Side 8” (203 mm)
Opposite Side 6" (152 mm)
Front (Alcove)* 18” (457 mm)
Flue/Vent Connector 6” (152 mm)
Return/Supply Water 1-1/4”, Gas In 1/2” NPT
SVB-2 - 1.75 Gallons, SVB-3 - 3.00 Gallons, SVB-4 - 4.25 Gallons, SVB-5 - 5.50 Gallons, SVB-6 - 6.75 Gallons, SVB-7 - 8.00 Gallons
Boiler Control Module: Recessed Honeywell Control (High Limit/Electronic Ignition Control). User Display Interface: Digital Temperature Display. Heat Exchanger: Cast Iron Sections with Cast Iron Push Nipples. Combustion: Completely Installed and Wired Gas Control System with Titanium Composite Burners and Manifold consisting of: Automatic Redundant Combination Gas Valve, 24 Volt Intermittent Pilot Control, Continuous Retry 100% Shut Off, Combination Pilot Burner/Electrode/Flame Sensor. Electrical: 24 Volt Transformer, Service Switch. Safety: Flame Roll-Out Safety Shut-Off (Fuse Link) and Pressure Switch (vent safety shutoff) with Spare Fuse Link included. Other: Assembled Boiler with Insulated Jacket, Induced Draft Fan, Combination Temperature/Pressure Gauge, Circulator Pump, ¾” Drain Valve, 30lb. ASME Relief Valve.
Natural Gas or Propane, Combustible Floor Plate, Fill-Trol, Thimble, Sidewall Vent Hood
Heating
Capacity
(1)
(MBH)
Model A (Width) B (Height) C (Depth) Weight
SVB-2 11” 29” 23-1/4” 225 lbs.
SVB-3 14-1/4” 29” 23-1/4” 265 lbs.
SVB-4 17-1/2” 29” 23-1/4” 322 lbs.
SVB-5 20-3/4” 29” 23-1/4” 370 lbs.
SVB-6 24” 29” 23-1/4” 431 lbs.
SVB-7 27-1/4” 29” 23-1/4” 480 lbs.
(1)
Net AHRI
Rating,
Water
(MBH)
(2)
Vent Diameter
To Chimney
(Category I)
Combustible Materials (Required)
(3)
Horizontal Vent
(Category III)
6” (152 mm)
AFUE %
(4)
All ratings and specications subject to change.
Contractor Assistance: 800.325.5479
C.S.A. Certified For
Natural Gas Or Propane
tel: 315.797.1310
Tested for 50 psi
ASME Working Pressure
P.O. Box 4729
Utica, New York 13504
fax: 315.797.3762
www.uticaboilers.com
PN 240009708 Rev. 1/15