Starre IV
There Are Some Things You Can Always Depend On...
Starfire Water IV
Up to 86% AFUE Oil Fired Hot Water Boiler
• Available in 9 sizes from 103 MBH to 252 MBH.
• Dependable Cast Iron Heat Exchanger with Cast Iron Push
Nipples. The Sections and Push Nipples expand at the same rate
when heated. By using similar materials instead of less expensive
gaskets the boiler maintains a water tight seal over time.
• Honeywell High Limit and Circulator Relay Control.
- Digital temperature display and diagnostics.
- Less Coil: Control monitors water temperature and delays the burner
starting until any residual heat has been transferred. Thermal purge
logic measures rate of temperature change inside the boiler and
delays burner ring accordingly. This maximizes efciency by turning
on the burner only when needed.
- With Coil: The Boiler utilizes a Honeywell non-thermal purge High
Limit, Low Limit and Circulator Relay control.
• Atmospheric Chimney Vent Boiler.
• Optional Tankless Heater Coil.
• Textured paint Jacket.
• Limited Lifetime Warranty (Residential Applications).
• Made in the U.S.A.
Utica Starre IV Residential Oil Fired Water Boiler
(1)
Heating
Capacity
Tankless Heater
Dimensional Diagram Model
SFH-3085W 0.85 119 103 90 8”x8”x15’
SFH-3100W 1.00 140 119 103 8”x8”x15’
SFH-4100W 1.00 140 122 106 8”x8”x15’
SFH-4125W 1.25 175 151 131 8”x8”x15’
SFH-4145W 1.45 203 173 150 8”x8”x15’
Front View
SFH-5160W 1.60 224 193 168 8”x8”x15’
SFH-5185W 1.85 259 221 192 8”x8”x15’
SFH-6175W 1.75 245 212 184 8”x8”x15’
SFH-6210W 2.10 294 252 219 8”x8”x15’
(1) Oil burner input based on 140,000 Btu per gallon.
2)Net AHRI water ratings shown are based on a piping and pickup allowance of 1.15. Consult manufacturer before selecting a boiler for installation having unusual piping and
pickup requirements, such as intermittent system operation, extensive piping systems, etc.
3) Heating Capacity and AFUE based on 13.0% CO
General Information (See Installation, Operation and Maintenance Manual for complete instructions)
Clearances
Required
distances
measured from
boiler.
Connections
(All Models)
Electrical 120 Volts AC, 60 hertz, 1 phase, Less than 12 amps (15 amp circuit recommended).
Side View
Tankless
Heater
Capacities
Dimensions/
Weights
Standard
Equipment
Options Taco, Grundfos or Less Pump; Tankless Coil.
AHRI Oil Burner Input
G.P.H. MBH Water MBH
with -0.02” W. C. draft over re and #1 smoke or less. Tested in accordance with U.S. Department of Energy test procedures.
2
Top
Sides
Front
Rear 6" (152 mm)
Flue Connector
Supply Tapping - 2", Return Tapping 1-1/2" NPT, Oil Line 3/8" O.D. copper tubing for runs of 50 feet or
less, and ½" O.D. for longer runs.
Model
SFH-3085WT 0.85 T3 3 10.5
SFH-3100WT 1.00 T3 3-1/4 10.5
SFH-4100WT 1.00 T4 3-1/4 13.5
SFH-4125WT 1.25 T4 3-3/4 13.5
SFH-4145WT 1.45 T4 4 13.5
SFH-5160WT 1.60 T4 4 16.5
SFH-5185WT 1.85 T4 4-1/4 16.5
SFH-6175WT 1.75 T4 4-1/4 19.5
SFH-6210WT 2.10 T4 4-1/2 19.5
No. of
Sec.
3 17-7/8" 11-1/4" 6" 534 lbs.
4 21-1/2" 12-5/8" 6" 668 lbs.
5 25-1/8" 14-1/4" 7" 781 lbs.
6 29-1/4" 15-15/16" 8" 901 lbs.
Boiler Controls: Primary Control, High Limit and Circulator Control
Heat Exchanger: Cast Iron Heat Exchanger with Cast Iron Push Nipples. Swing out Burner Door.
Combustion: Oil Burner, Target Wall/Liner.
Electrical: Wiring Harness, Burner Electrical Disconnect.
Other: Crated Boiler, Flush Jacket, Circulator- 1¼", Supply Tapping-2", Return Tapping-1 1/2", Temperature
Pressure Gauge, Safety Relief Valve, Drain Valve.
For Tankless Heater Units add Tankless Hot Water Coil and Triple Combination High Limit/Low Limit/Circulator
Control.
Input Rate
G.P.H.
A
(Depth of Flush Jacket)
Net AHRI
Ratings
(3)
MBH
Number
(Front of Jacket to Center
Line of Flue Outlet)
Tankless Heater Capacity
Intermittent Draw G.P.M.
B
(2)
Min. Natural Draft
Chimney Size
Combustible Materials (Required)
24" (610 mm)
6" (152 mm)
24" (610 mm)
9" (229 mm)
Boiler Water
Content (Gallons)
(Flue Outlet Diameter)
C
AFUE
85.0%
84.0%
86.0%
85.0%
84.0%
85.0%
84.0%
85.0%
84.0%
Weight
(3)
Contractor
Assistance: 800.325.5479
Certications
Tested for 75 psi ASME
Working Pressure
tel: 315.797.1310
PN 240009798 Rev. 12/14All ratings and specications subject to change.