SFE Series IV
There Are Some Things You Can Always Depend On...
SFE IV
82% AFUE Oil Fired Steam Boiler
• Available in 4 sizes from 106 MBH to 247 MBH.
• Dependable Cast Iron Heat Exchanger with Cast Iron Push
Nipples. The Sections and Push Nipples expand at the same rate
when heated. By using similar materials instead of less expensive
gaskets the boiler maintains a water tight seal over time.
• Patented Protective Heat Shield Bafe to protect the casting
above the water line.
• Honeywell Pressure Control, Boiler Water Level Gauge Glass,
and Steam Pressure Gauge.
• Electronic Low Water Cutoff.
• Atmospheric Chimney Vent Boiler.
• Textured paint Jacket with compact footprint.
• Cast Iron swing door and large ueways allow for easy
cleaning and servicing.
• 10 Year Limited Warranty (Residential Applications).
• Made in the U.S.A.
Utica SFE Series IV Residential Oil Fired Steam Boiler
Dimensional
Diagram
Front View
21.7/8”
Elwco
Cycle
Guard
Oil
Burner
Side View
A.S.M.E. Pressure
35.3/4”
16”
9.1/32”
“C”
Relief Valve
“B”
“A”
Model
AHRI Oil
Burner Input
G.P.H. MBH
Htg.
(1)
Cap.
(2)
MBH
SFE-3090S 0.90 126 106 80 333 6" 8”x8”x15’ 150
SFE-4125S 1.25 175 147 11 0 458 6" 8”x8”x15’ 140
SFE-5185S 1.85 259 216 162 675 8" 8”x8”x15’ 150
Without
Tankless
SFE-6210S 2.10 294 247 185 771 8" 8”x8”x15’ 145
SFE-3090ST 0.90 126 106 80 333 6" 8”x8”x15’ 150
SFE-4125ST 1.25 175 147 110 458 6" 8”x8”x15’ 140
With
SFE-5185ST 1.85 259 216 162 675 8" 8”x8”x15’ 150
Tankless
SFE-6210ST 2.10 294 247 185 771 8" 8”x8”x15’ 145
(1) Burner input is based on an oil heating value of 140,000 Btu/gal.
Pressure
Control
(2) MBH = 1000 Btu per hour [Btu = British Thermal Unit].
(3) Net AHRI Steam Ratings based on piping and pick-up allowance of 1.333. Consult manufacturer before selecting boiler for installations having unusual piping and
pick-up requirements, such as intermittent system operation, extensive piping, etc.
(4) Heating Capacity and AFUE based on 13.0% CO2 with -0.02” W.C. draft over re and #1 smoke or less. Tested in accordance with U.S. Department of Energy test
procedures.
General Information (See Installation, Operation and Maintenance Manual for complete instructions)
Top
Clearances
Required
distances
measured from boiler.
Connections
(All Models)
Electrical 120 Volts AC, 60 hertz, 1 phase, Less than 12 amps (15 amp circuit recommended).
Tankless Heater
Capacities
Dimensions/
Weights
Standard
Equipment
Options Tankless Coil.
Left Side
Right Side
Front
Back 24” (610 mm)
Flue Connector
Supply Tapping Two 2”, Return Tapping 1-1/2”, Oil Line 3/8” O.D. copper tubing for runs of 50 feet or less,
and ½” O.D. for longer runs.
Model
Input
Rate
G.P.H.
Tankless
Heater Number
SFE-3090ST 0.90
SFE-4125ST 1.25 41/2 13 9
SFE-5185ST 1.85 41/2 15 10
SFE-6210ST 2.10 41/2 15 10
No. of
Sec.
A
(Length of
Flush Jacket)
3 163/8” 61/2” 6” 534 lbs.
4 201/4” 81/2” 6” 688 lbs.
5 235/8” 101/4” 7” 781 lbs.
6 271/2” 85/16” 8” 901 lbs.
Boiler Controls: Honeywell Pressuretrol, Boiler Water Level Gauge Glass, and Steam Pressure Gauge.
Heat Exchanger: Cast Iron Heat Exchanger with Cast Iron Push Nipples, Swing Door.
Combustion: Beckett Oil Burner, Target Wall/Liner.
Electrical: Wiring Harness, Burner Electric Disconnect.
Safety: Electronic Low Water Cut Off.
Other: Crated Boiler, Flush Jacket, ASME Relief Valve, Drain Valve, Plastic Cover, Two 2” Supply Tappings,
1-1/2” Return Tapping and Skim Port.
For Tankless Heater Units: Add Tankless Hot Water Coil and 4006 Limit Control.
(4)
L-24
Net AHRI
Ratings
Steam
MBH
(Front of Jacket
to Center Line
of Flue Outlet)
Min. Nat. Draft
(3)
Chimney Size
Sq. Ft.
Steam
Round Square
Combustible Materials (Required)
Tankless Heater
Capacity Intermittent
Draw G.P.M.
2 11 8
B
Pump
Press.
PSI
Nozz.
Furn.
0.75-60°B
1.10-60°B
1.50-70°B
1.75-70°B
0.75-60°B
1.10-60°B
1.50-70°B
1.75-70°B
24” (610 mm)
6” (152 mm)
24” (610 mm)
24” (610 mm)
9” (229 mm)
Boiler Water
Content (Gallons)
To Water
Line
(Flue Outlet Diameter)
C
AFUE %
(4)
82.0%
82.0%
82.0%
82.0%
82.0%
82.0%
82.0%
82.0%
To LWCO Line
Weight
Certications
All ratings and specications subject to change.
Contractor
Assistance: 800.325.5479
Tested for 15 psi ASME
Working Pressure
tel: 315.797.1310
P.O. Box 4729
Utica, New York 13504
•
fax: 315.797.3762
www.uticaboilers.com
PN 240009857 Rev. 4/14