PEG Series E
Utica Boilers. Keeping Generations Warm Since 1928.
PEG E
Up to 83.4% AFUE Gas Fired Steam Boiler
•
Classic, low profile, compact design available in 7 sizes
from 75 MBH to 299 MBH.
•
Redesigned textured paint jacket features an easy to remove, one piece
front panel that conceals and protects the electronic ignition control.
•
Dependable Cast Iron Heat Exchanger with Cast Iron Push Nipples. The
Sections and Push Nipples expand at the same rate for a water tight seal
with greater longevity.
•
LWCO (Probe Type) is located on the side of the boiler allowing for quick
inspection and testing.
•
Includes Pressure High Limit Control, Pressure Gauge, Gauge Glass.
•
Atmospheric Chimney Vent Boiler with rear mounted Integral Draft Hood
and Vent Damper. Low profile compact design makes it ideal for low
clearance installations.
•
Easy piping features with 2” Single and dual piping riser options
(depending on boiler size), simplifying replacement piping.
•
Stainless Steel Burners.
•
Brass/copper pig tail siphon for long life.
•
10 Year Non-Prorated Warranty (Residential Applications).
•
Made in the USA.
Utica PEG Series E Residential Gas Fired Steam Boiler
A
2" NPT
½"
NPT
Plug
2" NPT
Safety
Relief
Valve
Floor
B
5½"
Depth C
29"
25"
12⅜"
16 "
13½"
2" NPT
2" NPT
5
/
8
B
Depth C
29"
2" NPT
2" NPT
A
Safety
Relief
Valve
Floor
B
5½"
Depth C
29"
2" NPT
2" NPT
Net AHRI Rating
Steam
(PPF)
Dimensional Diagram Model
Front
A
PEG075EID 75 62 1.33 195 47 3 5” 82.2%
PEG112EID 112 93 1.33 292 70 4
PEG150EID 150 125 1.33 391 94 5 6” 82.6%
PEG187EID 187 156 1.33 488 117 6 7” 82.8%
PEG225EID 225 188 1.33 587 141 7 7” 83.0%
PEG262EID 262 219 1.33 685 164 8 7” 83.2%
PEG299EID 299 250 1.33 782 188 9 7” 83.4%
Heating Capacity and AFUE are based on DOE (Department of Energy) test procedures.
(1) Input rating for sea level to 2,000 ft. above sea level. Altitudes over 2000 ft. above sea level, reduce input rate 4% for every 1000 ft.
(2) Net AHRI steam ratings shown are based on a piping and pickup allowance of 1.333. Consult manufacturer before selecting a boiler for installations having
unusual piping and pickup requirements, such as intermittent system operation, extensive piping systems, etc.
General Information (See Installation, Operation and Maintenance Manual for complete instructions)
Clearances
(3) Required
distances
Left Side
B
Right Side
C
B
Back
measured from
boiler.
*Denition of
Alcove is three
sided space with
no wall in front
of boiler. ANSI
standard for
alcove is 18 inches
from appliance
to leading edge
of side walls as
shown in IOM.
Connections
(All Models)
Electrical 120 Volts AC, 60 hertz, 1 phase, Less than 12 amps (15 amp circuit recommended)
Dimensions/
Weights
Standard
Equipment
Input Rate
(MBH)
(1)
Heating
Capacity
(MBH)
(1)
Top
Rear 6” (152 mm)
Control Side 7” (178 mm)
Opposite Side 6” (152 mm)
Flue/Vent Connector 6” (152 mm)
Return/Supply Tappings 2” NPT, Gas In 075/112/150 1/2” NPT, 187/225/262/299 3/4” NPT
Model A B C Weight
PEG075EID 10-7/8” 35-7/8” 28-3/8” 297 lbs.
PEG112EID 14-1/8” 35-7/8” 28-3/8” 368 lbs.
PEG150EID 17-3/8” 35-7/8” 29-3/8” 440 lbs.
PEG187EID 20-5/8” 35-7/8” 30-3/8” 512 lbs.
PEG225EID 23-7/8” 35-7/8” 30-3/8” 584 lbs.
PEG262EID 27-1/8” 35-7/8” 30-3/8” 659 lbs.
PEG299EID 30-3/8” 35-7/8” 30-3/8” 736 lbs.
Boiler Controls: LWCO (Probe Type), Pressure High Limit Control, Pressure Gauge, Gauge Glass.
Heat Exchanger: Cast Iron Sections with Cast Iron Push Nipples, (2) - 2” Supply Tappings;
(2) - 2” Return Tappings.
Combustion: Stainless Steel Burners, Gas Valve, Intermittent Pilot Control with Continuous Retry and
Combination Pilot Burner/Electrode Flame Sensor, Integral Draft Hood, Vent Damper.
Electrical: 24 Volt, 24VA Transformer.
Safety: Blocked Vent and Rollout Safety Switches, Pop Safety Valve.
Other: Crated Cast Iron Boiler with Insulated Jacket; Boiler Drain.
Steam
(Sq. Ft.)
(2)
Steam
(Mbh)
No. of
Sections
Vent
Pipe
Size
5”
Combustible Materials (Required)
6” (152 mm)
AFUE %
82.4%
(3)
Contractor
Assistance: 800.325.5479
Options
Certications
Both Natural Gas or LP models available. Other options include: Electronic Water Feeder,
Manual Reset Pressure Switch and Low Water Cut-Off, Combustible Floor Plate.
15 psi MAWP
P.O. Box 4729
•
fax: 315.797.3762
Utica, New York 13504
tel: 315.797.1310
www.uticaboilers.com
PN 240009710 Rev. 6/14All ratings and specications subject to change.