Utica Boilers JE Brochure

JE Steam
There Are Some Things You Can Always Depend On...
JE Steam
Commercial Gas Fired Steam Boiler
Electronic Ignition Base Standard Equipment:
Base
Burner Orice
Manifold
Main and Pilot Burner
Electronic Pilot Gas Valve
Intermittent Pilot Module
Complete Jacket Assembly
JE Series Boiler Bases are pre-assembled at the factory with burner manifold, burner orices, gas valves and electronic ignition installed, ready for eld installation of the pre-tested sections and appropriate packages.
Plug ‘N Play Harness and Junction Box
Individual base and junction box controls are designed for easy installation with Plug ‘n Play harnesses. The entire boiler links together in a “snap”. A color-coded factory supplied harness eliminates wiring errors.
CSD1 Option
JE boilers are available with a CSD1 option to comply with CSD1 standards where required by building code. The CSD1 option provides the increased number of controls and safety devices required to meet CSD1 standards.
Steam Trim Package:
Low Water Cut-Off
Glass Gauge Set
Safety Valve
Steam Gauge
Pressure Limit
• Drain Valve
Utica JE Commercial Gas-Fired Steam Boiler
Net AHRI Ratings
Steam
(2)
(PPF)
Steam
(Sq. Ft.)
(3)
Steam
(Mbh)
(2)
Model
Input
(Mbh)
(1)
Gross
Output
(Mbh)
Base Size & Flue Outlet
300 (8")
400
(10")
500 (12") I.D. x Ht.
Chimney
(4)
Size
Vent
Connector
Size to
Chimney
(4)
Thermal
Efciency
JE300S
JE400S
JE500S
300 233 1.333 729 175 1 0 0 8" x 20' 8 77.0
400 310 1.333 971 233 0 1 0 10" x 20' 10 77.0
500 388 1.333 1213 291 0 0 1 12" x 20' 12 77.0
JE600S 600 465 1.333 1454 349 2 0 0 12" x 20' 12 77.0
JE700S 700 543 1.333 1696 407 1 1 0 12" x 20' 12 77.0
JE800S 800 620 1.333 1938 465 0 2 0 14" x 20' 14 77.0
JE900S 900 698 1.333 2183 524 0 1 1 14" x 20' 14 77.0
JE1000S 1000 775 1.333 2421 581 0 0 2 14" x 20' 14 77.0
JE1100S 1100 853 1.333 2667 640 1 2 0 16" x 20' 16 77.0
JE1200S 1200 930 1.333 2908 698 0 3 0 16" x 20' 16 77.0
JE1300S 1300 1008 1.333 3150 756 1 0 2 16" x 20' 16 77.0
JE1400S 1400 1085 1.333 3392 814 0 1 2 18" x 20' 18 77.0
JE1500S 1500 1163 1.333 3633 872 0 0 3 18" x 20' 18 77.0
Right & Left End Tappings Data
Opening Size Steam
A 4” Supply and Return
B 1/2”
D
A
F B
C 3/4” Drain, Left End
G
B
C 3/4” Drain, Right End
Primary LWCO
and Gauge
Glass set
A
E
C
*If opening F is to be used for something other than the Safety Valve or Pressure Relief Valve, or the Safety/Relief Valve is larger than 1”, the Safety/Relief Valve must be installed in the Header Piping as near to the boiler as possible.
D 1/2” Plugged
E 1” Accessories
*F 1” Safety Valve
G 3/4”
Plugged or
Electronic
(Probe Type) LWCO
1. Ratings are at sea level to 2,000 feet. For altitudes above 2,000 feet, reduce all ratings 4% for each 1,000 feet above sea level.
2. Net steam ratings based on piping and pickup allowance of 1.333 (300-1500). Contact Technical Support before selecting boiler for installations having unusual piping and pick-up factors, such as intermittent system operations, extensive piping systems, etc.
3. Ratings in square feet are computed at 240 Btuh/square foot for steam boilers.
4. Chimney sizes shown are one option based on a typical venting system as shown in Figure 6 of the Installation Manual, and sized according to the National Fuel Gas Code, assuming Type B double wall vent and vent connectors, other venting system designs are acceptable as shown on Flue Connection And Venting section of the installation manual. For further chimney design and sizing information, consult the National Fuel Gas Code, ANSI Z223.1/NFPA 54-latest revision, or ASHRAE HVAC Systems and Equipment Handbook, Chimney, Gas Vent, and Fireplace Systems, or the Standard for Chimneys, Fireplaces, Vents, and Solid Fuel Burning Appliances. NFPA 211. Follow standard engineering practice.
Certications
PN 240009442 Rev. 6/14All ratings and specications subject to change.
Contractor Assistance: 800.325.5479
Utica, New York 13504
tel: 315.797.1310
www.uticaboilers.com
P.O. Box 4729
fax: 315.797.3762
Loading...