Utica Boilers CuB Series Submittal Manual

Utica Boilers CHB-100/130 - Submittal
Engineer:____________________________________________
Project Name:________________________________________
Project Location:______________________________________
Contractor:___________________________________________
APPLICATION:
Modulating Gas red water heating boiler for indoor installation. Approved for closet or alcove installations. For use with natural or liqueed petroleum (LP/Propane) fuel gases, LP conversion kits available as option. Wall mounted – optional oor stand available. All boilers are factory assembled with controls and wiring and test red to ensure dependable performance. Boiler shall be certied for Category I and Category III applications.
CERTIFICATION AND APPROVALS:
Copper tube heat exchanger is manufactured and tested in accordance with American Society of Mechanical Engineers (ASME) and certied by Canadian Standards Association (CSA). Copper tube heat exchanger is tested for maximum allowable working pressure of 43.5 psig in accordance with ASME boiler and pressure vessel code, section IV, rules for construction of heating boilers. A 30 psig safety relief valve is shipped standard.
BOILERS INCLUDE:
Wall mount bracket
Boiler has separate dedicated supply & return water connections to supply hot water directly to an Indirect
tank.
Boiler is equipped with an automatic 3 way diverting valve to allow Domestic Hot Water Priority operation.
Boiler includes an internal pressure activated bypass loop to eliminate the need for primary secondary
piping and includes an internal factory installed and wired circulator pump.
Digital Boiler Control:
X Control system is PCB integral controller with LCD digital display that includes graphical interface.
X Control senses supply water temperature and adjusts the boiler ring rate to deliver amount of heat
needed.
X Control can sense and display supply water temperature and indicate by icon when boiler is in central
heating or domestic water mode.
X Control can accept a wired Outdoor Air sensor and has eld selectable reset curves
X Control continuously monitors boiler during operation and standby modes. Control receives input data
from dual temperature sensor, air pressure transducer, and outdoor air temperature sensors (when used) to adjust modulation rate accordingly.
X Control can power and accept input from eld supplied LWCO device.
P/N 240010784 REV C, [02/2015]2201 Dwyer Ave. Utica, NY 13501 www.UticaBoilers.com
Boiler Combustion System:
X The Gas valve is a modulating valve capable of ring from 100% input ring rate to 33% input ring rate.
X Induced draft blower is variable speed. PCB uses air pressure transducer to vary blower speed.
X Burners and manifold shall be constructed of stainless steel.
X Ignition system shall be direct spark single rod ame sensing
Primary Heat Exchanger:
X Boiler’s primary heat exchanger is constructed of copper tube with copper ns, stainless steel support
plates and is covered with a high temperature protective coating.
• Electrical:
X 120 volts AC, 60 Hertz, 1-phase; less than 12 amps.
X Factory wired 6-foot appliance cord with male plug end.
X Low voltage terminal strip for Thermostat, and optional Outdoor Air Sensor,
DHW Indirect tank sensor and LWCO
Optional Equipment:
X Floor mounting stand
X Outdoor Air Sensor
X Direct Vent Termination Kit
X LP Conversion kit
X DHW Sensor kit for Indirect tank
SEA LEVEL RATINGS
NATURAL AND PROPANE GASES
Boiler Input Rate
Size
Maximum Minimum
CHB-100 CHB-130
(1)
1000 Btu/hr (British Thermal Units Per Hour)
(2)
Heating Capacity and AFUE (Annual Fuel Utilization Efciency) are based on DOE (Department of Energy) test procedures.
(3)
Net AHRI Ratings based on piping and pickup allowance of 1.15. Contact Technical Support before selecting boiler for
installations having unusual piping and pickup requirements, such as intermittent system operation, extensive piping systems, etc.
(MBH)
100 31.5 85 73.0 85.0 130 43.5 110 96.0 85.0
(1)
Heating
Capacity
(MBH)
(1)(2)
Net AHRI
Rating, Water
(MBH)
(1)(3)
AFUE
Constructed and hydrostatically tested for maximum allowable working pressure of 43.5 psig (pounds per square inch gauge)
(.30MPa)
in accordance with ASME Boiler and Pressure Vessel
Code, Section IV, Rules for Construction of Heating Boilers.
USA - Input rates are derated 4% for each 1000 ft (300m) above sea level,beyond 2000 ft. (600m).
CANADA - Ratings above used for elevations up to 200 ft (600m) above sea level.
- For elevations between 2000 ft (600m) and 4500 ft (1350m), derate 10% using high altitude kit.
- Contact Provincial authority having jurisdiction for installations above 4500 feet (1350m) above sea level.
(2)
2201 Dwyer Ave. Utica, NY 13501 www.UticaBoilers.com
P/N 240010784 REV C, [02/2015]