Regal Series
Hot Plates
Models:
RHPA-112A RHPA-224A RHPA-424A RHPA-848A
RHPA-212A RHPA-336A RHPA-636A
Item: ______________________________
Quantity: __________________________
Project: ____________________________
Approval: __________________________
Date: ______________________________
Regal Series Hot Plates
• 3/4" gas regulator
• 4" (102mm) legs with
adjustable feet
• Exterior finish - stainless
steel front sides, landing
ledge and valve cover
Optional Features:
Stainless steel stand with
intermediate shelf
Casters on stand - swivel
type
Model RHPA-424A
Standard Features:
• Heavy-dury, removable
drip pan
• 20,000 BTU/hr. per burner - natural gas
• 17,500 BTU/hr. per burner - propane gas
• Individual burner controls
• Standing pilot for instant
lighting
Specification:
Shall be U.S. Range Regal Hot Plate, Model _______
with total BTU/hr rating of _______ when used
with natural/propane gas. Finish is to be stainless
steel front and sides.
TOTAL BTU SHIPPING INFORMATION
Model No. Description
RHPA-112A 1 Open Burner - 12"(305mm) W × 16"(406mm) D 20,000/17,500 50/23 4
RHPA-212A 2 Open Burners - 12"(305mm) W × 28"(711mm) D 40,000/35,000 73/33 4
RHPA-224A 2 Open Burners - 24"(610mm) W × 16"(406mm) D 40,000/35,000 81/37 8
RHPA-336A 3 Open Burners - 36"(914mm) W × 16"(406mm) D 60.000/52,500 123/56 25
RHPA-424A 4 Open Burners - 24"(610mm) W × 28"(711mm) D 80,000/70,000 135/61 8
RHPA-636A 6 Open Burners - 36"(914mm) W × 28"(711mm) D
RHPA-848A) 8 Open Burners - 48"(1`219mm) W × 28"(711mm) D
Natural/
Propane
120,000/105,000
160,000/140,000
Lbs/Kg Cu. Ft.
191/87 25
247/112 33
Garland Commercial
Industries, LLC
185 East South Street
Freeland, PA 18224
Phone: (570) 636-1000
Fax: (570) 636-3903
Garland Commercial Ranges Ltd
1177 Kamato Road,
Mississauga, Ontario
L4W 1X4 CANADA
Phone: 905-624-0260
Fax: 905-624-5669
Enodis UK LTD
Swallowfield Way,
Hayes, Middlesex
UB3 1DQ ENGLAND
Telephone: 081-561-0433
Fax: 081-848-0041
Regal Series Hot Plates
6"
[152mm]
28-1/2”
[724mm]
22-1/2"
[572mm]
10"
[254mm]
4
[102mm]
6"
[152mm]
1" [25mm]
AIR SPACE
27-1/4"
[692mm]
3/4" N.P.T
[19mm]
REAR GAS
INLET
2"
[51mm]
1-1/4"
[32mm]
24-1/2"
[622mm]
2-3/4"
[70mm]
12"
[305mm]
24"
[610mm]
RHPA-424A
36"
[914mm]
RHPA-636A
48"
[1219mm]
RHPA-848A
6"
[152mm]
17-1/4"
[438mm]
12-7/16"
[316mm]
10"
[254mm]
6"
[152mm]
4"
[102mm]
12"
[305mm]
1" [25mm]
AIR SPACE
16"
[406mm]
36" [914mm]
RHPA-336A
3/4" N.P.T
[19mm]
REAR GAS
INLET
2"
[51mm]
1-1/4"
[32mm]
3-3/4"
[95mm]
24" [610mm]
RHPA-224A
12-1/4"
[311mm]
RHPA-212A
RHPA-112A
Model #
Dimensions
Width Depth Height
No. of
Burners
Total Nat.
Gas BTU
RHPA-112A 12"(305mm) 16"(406mm) 10"(254mm) 1 20,000 17,500
RHPA-212A 12"(305mm) 28"(711mm) 10"(254mm) 2 40,000 35,000
RHPA-224A 24"(610mm) 16"(406mm) 10"(254mm) 2 40,000 35,000
RHPA-336A 36"(914mm) 16"(406mm) 10"(254mm) 3 60,000 52,500
RHPA-424A 24"(610mm) 28"(711mm) 10"(254mm) 4 80,000 70,000
RHPA-636A 36"(914mm) 28"(711mm) 10"(254mm) 6 120,000 105,000
RHPA-848A 48"(1219mm) 28"(711mm) 10"(254mm) 8 160,000 140,000
Operating Pressure All Models
Natural Gas Propane
5" WC (12.5 Mbar) 10" WC (25 Mbar)
Gas Manifold 3/4" NPT
Garland/U.S. Range products are not approved or authorized for home or residential use, but are intended for
commercial applications only. Garland / U.S. Range will
not provide service, warranty, maintenance or support
of any kind other than in commercial applications.
Total Pro.
Gas BTU
Many local codes exist and it is the responsibility of the owner and installer to comply with those codes.
Garland Commercial
Industries, LLC
185 East South Street
Freeland, PA 18224
Phone: (570) 636-1000
Fax: (570) 636-3903
Garland Commercial Ranges Ltd
1177 Kamato Road,
Mississauga, Ontario
L4W 1X4 CANADA
Phone: 905-624-0260
Fax: 905-624-5669
Enodis UK LTD
Swallowfield Way,
Hayes, Middlesex
UB3 1DQ ENGLAND
Telephone: 081-561-0433
Fax: 081-848-0041
Form# RHPA (06/07)