Usr EV10i Owner's Manual

Page 1
POWER
EV10i
POWER
Page 2
OWNER'S MANUAL
USR EV10i
The"e-SPEC"mark symbolizes environmentally responsible technologies applied to USR power equipment, which contains our wish to" preserve nature for generations to come."
Page 3
1
Indicates a strong possibility of severe personal injury or
death if instructions are not followed.
Indicates a possibility of personal injury or equipment
damage if instructions are not followed.
The generator is designed to give safe and dependable service if operated according to instructions. Read and understand the Owner's Manual before operating the generator. Failure to do so could result in personal injury or equipment damage.
Thank you for purchasing a our generator.
This manual covers operation and maintenance of the EV10i generator.
All information in this publication is based on the latest product information available at the time of approval for printing.
We reserves the right to make changes at any time
and without incurring any obligation.
No part of this publication may be reproduced without written permission.
This manual should be considered a permanent part of the generator and should remain with it if it is resold.
Pay special attention to statements preceded by the following words:
Gives helpful information.
If a problem should arise, or if you have any questions about the generator, consult an authorized dealer.
The illustration may vary according to the type.
without notice and
Page 4
2
CONTENTS
..................................................................SAFETY INSTRUCTIONS . 3
............................................................SAFETY LABEL LOCATIONS . 6
...................................................Ce mark and noise label locations . 8
.......................................................COMPONENT IDENTIFICATION . 9
................................................................PRE-OPERATION CHECK . 13
.................................................................STARTING THE ENGINE . 18
Carburetor Modification for High Altitude Operation
...........................................................................GENERATOR USE . 22
.................................................................STOPPING THE ENGINE . 34
...............................................................................MAINTENANCE . 36
...........................................................TRANSPORTING/STORAGE . 43
......................................................................TROUBLESHOOTING . 45
.............................................................................SPECIFICATIONS . 47
..........................................................................WIRING DIAGRAM . 49
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
Page 5
ʵ
3
SAFETY INSTRUCTIONS
1.
To ensure safe operation
The engine exhaust system will be heated during operation and remain hot immediately after stopping the engine. To prevent scalding, pay attention to the warning marks attached to the generator.
The muffler becomes very hot during operation and remains hot for a while after stopping the engine. Be careful not to touch the muffler while it is hot. Let the engine cool before storing the generator indoors.
Exhaust gas contains poisonous carbon monoxide. Never run the generator in an enclosed area. Be sure to provide adequate ventilation. When installed inside, adequate ventilation should be provided.
The generator is designed to give safe and dependable service if operated according to instructions. Read and understand the Owner's Manual before operating the generator. Failure to do so could result in personal injury or equipment damage.
Never connect a cable other than the special cable for parallel operation to the parallel operation socket. Electric shocks can result if this instruction is not followed.
Page 6
ʵ
4
To ensure safe operation
Keep away from cigarette, smoke and sparks when refueling the generator. Always refuel in a well-ventilated location. Wipe up spilled gasoline at once.
Gasoline is extremely flammable and explosive under certain conditions. Refuel in a well ventilated area with the engine stopped.
Connections for standby power to a building's electrical system must be made by a qualified electrician and must comply with all applicable laws and electrical codes. Improper connections can allow electrical current from the generator to back feed into the utility lines. Such back feed may electrocute utility company workers or others who contact the lines during a power outage, and when utility power is restored, the generator may explode, burn, or cause fires in the building's electrical system.
Page 7
5
To ensure safe operation
Always make a pre-operation inspection (page ) before you start the engine. You may prevent an accident or equipment damage. Place the generator at least 1 m (3 ft) away from buildings or other equipment during operation. Operate the generator on a level surface. If the generator is tilted, fuel spillage may result.
Keep children and pets away from the generator when it is in operation. Keep away from rotating parts while the generator is running. The generator is a potential source of electrical shocks when misused; do not operate with wet hands. Do not operate the generator in rain or snow and do not let it get wet.
Know how to stop the generator quickly and understand operation of all the controls. Never permit anyone to operate the generator without proper instructions.
13
Page 8
6
SAFETY LABEL LOCATIONS
2.
HOT CAUTION
CONNECT CAUTION
FUEL CAUTION/PARALLEL OPERATION CAUTION
READ OWNER扴 MANUAL
EXHAUST CAUTION
[For European model: G, GW, B, F, W types]
These labels warn you of potential hazards that can cause serious injury. Read the labels and safety notes and precautions described in this manual carefully.
If a label comes off or becomes hard to read, contact your dealer for a replacement.
EV10i
Inverter Generator
Page 9
7
[For Australian model: U type]
SOCKET CAUTION
Page 10
8
Dry weight
NOISE LABEL
Maximum altitude
IP code
Performance class
Maximum ambient temperature
CE mark and noise label locations
CE MARK
[For European model: G, GW, B, F, W types]
Mo de l
EV10i
Inverter Generator
EV10i
Inverter Generator
Page 11
9
COMPONENT IDENTIFICATION3.
CHOKE LEVER
FUEL CAP VENT LEVER
FUEL FILLER CAP
CONTROL PANEL
FRAME SERIAL NUMBER
ENGINE SWITCH
LEFT SIDE MAINTENANCE COVER
MUFFLER
SPARK PLUG MAINTENANCE COVER
STARTER GRIP
Record the frame serial number in the space below. You will need this serial number when ordering parts.
Frame serial number:
Page 12
10
DC CIRCUIT PROTECTOR
DC RECEPTACLE
OIL ALERT INDICATOR LIGHT
ECO THROTTLE SWITCH
OUTPUT INDICATOR LIGHT
OVERLOAD INDICATOR LIGHT
GROUND TERMINAL
AC RECEPTACLE PARALLEL OPERATION SOCKETS
CONTROL PANEL
G, GW, F, W types
Page 13
11
AC RECEPTACLE
AC RECEPTACLE
B type
U type
Page 14
12
Eco Throttle
ECO:
OFF:
OFF
ECO
ECO THROTTLE SWITCH
EECCOO
OOFFFF
Engine speed is kept at idle automatically when the electrical appliance is disconnected and it returns to the proper speed by the electrical load when electrical appliance is connected. This position is recommended to minimize the fuel consumption while in operation.
Eco Throttle system does not operate. Engine speed is kept over rated speed.
Eco Throttle system does not operate sufficiently if the electrical appliance requires the momentary electric power.
In DC operation, turn the eco throttle switch to the OFF position.
When high electrical load appliances is connected simultaneously, turn the Eco Throttle switch to the OFF position to reduce voltage changes.
Page 15
13
PRE-OPERATION CHECK
4.
Be sure to check the generator on a level surface with the engine stopped.
Using nondetergent oil or 2-stroke engine oil could shorten the engine抯 service life.
SAE Viscosity Grades
AMBIENT TEMPERATURE
Check the engine oil level.
Use high-detergent, premium quality 4-stroke engine oil, certified to meet or exceed U.S. automobile manufacturer?s requirements for API Service Classification SG, SF. Select the appropriate viscosity for the average temperature in your area.
1.
Page 16
14
Running the engine with insufficient oil can cause serious engine damage.
OIL FILLER HOLE
OIL FILLER CAP
UPPER LEVEL
DIPSTICK
Loosen the cover screw and remove the left side maintenance cover. (see page ) Remove the oil filler cap, and wipe the dipstick with a clean rag. Check the oil level by inserting the dipstick in the filler hole without screwing it in. If the oil level is below the end of the dipstick, refill with recommended oil up to the top of the oil filler neck.
The Oil Alert System will automatically stop the engine before the oil level falls below the safe limit. However, to avoid the inconvenience of an unexpected shutdown, it is still advisable to visually inspect the oil level regularly.
37
Page 17
15
Avoid repeated or prolonged contact with skin or breathing of vapor. KEEP OUT OF REACH OF CHILDREN.
Be careful not to spill fuel when refueling. Spilled fuel or fuel vapor may ignite. If any fuel is spilled, make sure the area is dry before starting the engine.
Do not overfill the fuel tank (there should be no fuel above the upper limit mark). After refueling, make sure the fuel filler cap is closed properly and securely.
Refuel in a well-ventilated area with the engine stopped. Do not smoke or allow flames or sparks in the area where the engine is refueled or where gasoline is stored.
Gasoline is extremely flammable and is explosive under certain conditions.
FUEL FILLER CAP
OPEN
UPPER LIMIT MARK
Check the fuel level.
If the fuel level is low, refuel the fuel tank until the level as specified. After refueling, tighten the fuel filler cap securely.
Never use stale or contaminated gasoline or an oil/gasoline mixture. Avoid getting dirt or water in the fuel tank.
Use automotive unleaded gasoline with a Research Octane Number of 91 or higher (a Pump Octane Number of 86 or higher).
2.
Page 18
16
Gasolines containing alcohol
If you notice any undersirable operating symptoms while using a gasoline that contains alcohol, or one that you think contains alcohol, switch to a gasoline that you know does not contain alcohol.
Before buying fuel from an unfamiliar station, try to find out if the fuel contains alcohol, if it does, confirm the type and percentage of alcohol used.
USR cannot endorse the use of fuels containing methanol since evidence of their suitability is as yet incomplete.
Fuel system damage or engine performance problems resulting from the use of fuels that contain alcohol is not covered under the warranty.
Do not use gasohol that contains more than 10% ethanol. Do not use gasoline containing methanol (methyl or wood alcohol) that does not also contain cosolvents and corrosion inhibitors for methanol. Never use gasoline containing more than 5% methanol, even if it has cosolvents and corrosion inhibitors.
If you decide to use a gasoline containing alcohol (gasohol), be sure it's octane rating is at least as high as that recommended by USR . There are two types of "gasohol : one containing ethanol, and the other containing methanol.
Gasoline spoils very quicklr depending on factors such as light exposure, temperature and time. In worst cases, gasoline can be contaminated within 1 month. Using contaminated gasoline can seriously damage the engine (caburetor clogged, valve stuck). Such damage due to spoiled fuel is disallowed from coverage by the warrantry. To avoid this please strictly follow these recommendations:
Only use specified gasoline. To slow deterioration, keep gasoline in a certified fuel container. If long storage (more than 1 month) is foreseen, drain fuel tank and carburetor (page ).
43
"
Page 19
17
Never run the engine without the air cleaner element. Rapid engine wear will result from contaminants, such as dust and dirt, being drawn through the carburetor, into the engine.
COVER SCREW
AIR CLEANER ELEMENT
AIR CLEANER BODY
LOWER TAB
LEFT SIDE MAINTENANCE COVER
AIR CLEANER COVER
LATCH TAB
Check the air cleaner.
Check the air cleaner element to be sure it is clean and in good condition. Loosen the cover screw and remove the left side maintenance cover. Press the latch tab on the top of the air cleaner body, remove the air cleaner cover, check the element. Clean or replace the element if necessary. (see page ).
3.
38
Page 20
18
STARTING THE ENGINE
5.
FUEL CAP VENT LEVER
OONN
ON
ON
ON
ENGINE SWITCH
Before starting the engine disconnect any load from the AC receptacle.
Turn the fuel cap vent lever to the OFF position when transporting the generator.
Turn the engine switch to the ON position.
Turn the fuel cap lever fully clockwise to the ON position.1.
2.
Page 21
19
Do not allow the starter grip to snap back. Return it slowly by hand.
CLOSED
CLOSED
STARTER GRIP
CHOKE LEVER
Do not use the choke when the engine is warm or the air temperature is high.
Pull the starter grip lightly until you feel resistance, then pull the starter grip briskly toward the arrow as shown below.
Move the choke lever to the CLOSED position.3.
4.
Page 22
20
OPEN
CHOKE LEVER
OOPPEENN
Move the choke lever to the OPEN position as the engine warms up.
If the engine stops and will not restart, check the engine oil level (see page ) before troubleshooting in other areas.
5.
13
Page 23
21
When the carburetor has been modified for high altitude operation, the air-fuel mixture will be too lean for low altitude use. Operation at altitudes below 1,500 meters (5,000 feet) with a modified carburetor may cause the engine to overheat and result in serious engine damage. For use at low altitudes, have your servicing dealer return the carburetor to original factory specifications.
Carburetor Modification for High Altitude Operation
High altitude performance can be improved by specific modifications to the carburetor. If you always operate your generator at altitudes above 1,500 meters (5,000 feet), have your authorized servicing dealer perform this carburetor modification. This engine, when operated at high altitude with the carburetor modifications for high altitude use, will meet each emission standard throughout its useful life.
Even with carburetor modification, engine horsepower will decrease about 3.5% for each 300-meter (1,000-foot) increase in altitude. The ef­fect of altitude on horsepower will be greater than this if no carburetor modification is made.
At high altitude, the standard carburetor air-fuel mixture will be too rich. Performance will decrease, and fuel consumption will increase. A very rich mixture will also foul the spark plug and cause hard starting. Operation at an altitude that differs from that at which this engine was certified, for extended periods of time, may increase emissions.
Page 24
22
GENERATOR USE6.
Do not exceed the current limit specified for any one receptacle. Do not connect the generator to a household circuit. This could cause the damage to the generator or to electrical appliances in the house. Do not modify or use the generator for other purposes than it is intended for. Also observe the following when using the generator.
In either case, the total wattage of all appliances connected must be considered.
For continuous operation, do not exceed the rated power (see page
).
Connections for standby power to a building抯 electrical system must be made by a qualified electrician and must comply with all applicable laws and electrical codes. Improper connections can allow electrical current from the generator to backfeed into the utility lines. Such backfeed may electrocute utility company workers or others who contact the lines during a power outage, and when utility power is restored, the generator may explode, burn, or cause fires in the building抯 electrical system.
Do not connect an extension to the exhaust pipe. When an extension cable is required, be sure to use a tough rubber sheathed flexible cable (IEC 245 or equivalent). Limit length of extension cables; 60 m for cables of 1.5 mm
and 100
m for cables of 2.5 mm
. Long extension cables will lower usable power due to resistance in the extension cable. Keep the generator away from other electric cables or wires such as commercial power supply lines.
48
EARTH MARK
GROUND TERMINAL
Be sure to ground the generator when the connected equipment is grounded.
Page 25
23
If you use both at the same time, be sure not to exceed the total power for AC and DC. (See page ).
The DC receptacle can be used while the AC power is in use.
Most appliance motors require more than their rated wattage for startup.
48
Page 26
24
AC applications
Be sure that all appliances are in good working order before connecting them to the generator. If an appliance begins to operate abnormally, becomes sluggish, or stops suddenly, turn off the generator engine switch immediately. Then disconnect the appliance, and examine it for signs of malfunction.
Substantial overloading that continuously lights the overload indicator light (red) may damage the generator. Marginal overloading that temporarily lights the overload indicator light (red) may shorten the service life of the generator.
OUTPUT INDICATOR LIGHT (GREEN)
OVERLOAD INDICATOR LIGHT (RED)
PLUG
Start the engine and make sure the Output indicator (green) comes on. Confirm that the appliance to be used is switched off, and plug in the appliance.
1.
2.
Page 27
25
Output and Overload Indicators
OUTPUT INDICATOR LIGHT (GREEN)
OUTPUT INDICATOR LIGHT (RED)
The Output indicator (green) will remain ON during normal operating conditions.
Stop the engine if the Overload indicator (red) comes ON and investigate the overload source.
When an electric motor is started, both the Overload indicator (red) and the Output indicator (green) may go on simultaneously. This is normal if the Overload indicator (red) goes off after about five (5) seconds. If the Overload indicator (red) stays on, consult your generator
dealer.
If the generator is overloaded (in excess of 1.0 kVA), or if there is a short in the connected appliance, the output indicator light (green) will go OFF, the overload indicator light (red) will go ON and current to the connected appliance will be shut off.
Before connecting an appliance to the generator, check that it is in good order, and that its electrical rating does not exceed that of the generator. Then connect the power cord of the appliance, and start the engine.
Page 28
26
Parallel operation
In either case, the total wattage of all appliances connected must be considered.
For continuous operation, do not exceed the rated power.
Limit operation requiring maximum power to 30 minutes.
PARALLEL OPERATION SOCKETS
SPECIAL CABLE FOR PARALLEL OPERATION (SOLD SEPARATELY)
Rated power in parallel operation is:
Maximum power in parallel operation is:
1.8 kVA
2.0 kVA
Please read the item "GENERATOR USE" before connecting any equipment to be used.
A max output of 2.0 kVA can be obtained by using two units (EV10i) in parallel operation (connection in parallel).
There are the terminals into which the special cable is inserted for parallel operation. Always use only the special cable for parallel operation
Please order the special cable from the shop where you purchased the unit or from a service station.
(sold separately).
Page 29
27
Never connect the different generator models and types. Never connect a cable other than the special cable for parallel operation. Connect and remove the special cable for parallel operation with the engine stopped. For single operation, the special cable for parallel operation must be removed.
UNIT
UNIT
SPECIAL CABLE FOR PARALLEL OPERATION (SOLD SEPARATELY)
Depending on the equipment to be used, an overload may be caused, the overload indicator light (red) may light, and it may become impossible to take out any more electric power. Motors generally require two to three times of their power consumption for starting.
Connect the special cable for parallel operation to the two generators.
1.
Page 30
28
Confirm that the use equipment to be connected is switched off. When the equipment to be used is switched on, it will operate suddenly, and injuries or accidents may be caused.
OUTPUT INDICATOR LIGHT (GREEN)
OVERLOAD INDICATOR LIGHT (RED)
PLUG
GROUND TERMINALGROUND TERMINAL
Start each engine according to" STARTING THE ENGINE".
When the output indicator light (green) does not light and the overload indicator light (red) lights instead, set the engine switch to STOP, stop the engine once, and then start the engine again.
Confirm that the equipment to be used is switched off, and insert the plug of the equipment to be used into the AC receptacle of unit or unit .
Be sure to ground the generator when the connected equipment is grounded.
2.
3.
4.
Page 31
29
OUTPUT INDICATOR LIGHT (GREEN)
In case of normal operation In case of overload operation or short-circuit
OVERLOAD INDICATOR LIGHT (RED)
Switch on the equipment to be used. The output indicator light (green) will light.
At this time, the engine will not stop, so that the engine must be stopped by setting the respective engine switch to STOP.
In case of overload operation (refer to page ) or when trouble occurs for the equipment being used, the output indicator light (green) will go out, the overload indicator light (red) will light continuously, and no power will be put out.
6.
26
Page 32
30
When equipment requiring a large starting power, like a motor etc., is used, the overload indicator light (red) and the output indicator light (green) may light together for a short time (about 4 sec), but this is no abnormality. After start of the equipment, the overload indicator light (red) will go out and the output indicator light (green) will stay lit. When the operation of one generator is to be stopped after start of the equipment, the special cable for parallel operation also must be removed at the same time.
When electric power is to be taken again from the generator, switch off the equipment to be used and remove the plug from the AC receptacle. Confirm that the equipment and the connection are normal and that not too much power is to be taken, and then start the engine.
7.
Page 33
31
DC Application
To prevent the possibility of creating a spark near the battery, connect charging cable first to the generator, then to the battery. Disconnect cable first at the battery. Before connecting charging cable to a battery that is installed in a vehicle, disconnect the vehicles grounded battery cable. Reconnect the vehicle抯 grounded battery cable after the charging cables are removed. This procedure will prevent the possibility of a short circuit and sparks if you make accidental contact between a battery terminal and the vehicle抯 frame or body.
Do not attempt to start an automobile engine with the generator still connected to the battery. The generator may be damaged. Connect the positive battery terminal to the positive charging cord. Do not reverse the charging cables, or serious damage to the generator and/or battery may occur.
CHARGING CABLE (SOLD SEPARATELY: G, B, F, W types)
In DC operation, turn the eco throttle switch to the OFF position.
Connect the charging cable to the DC receptacle of the generator and then to the battery terminals.
The DC receptacle may be used for charging 12 volt automotive-type batteries only.
1.
Page 34
ʵ ʵ
32
Batteries produce explosive gases: If ignited, and explosion can cause serious injury or blindness. Provide adequate ventilation when charging.
Keep flames and sparks away, and do not smoke in the area. ANTIDOTE: If electrolyte gets into your eyes, flush thoroughly with warm water for at least 15 minutes and call a physician immediately. POISON: Electrolyte is poison. ANTIDOTE
KEEP OUT OF REACH OF CHILDREN.
External: Flush thoroughly with water. Internal: Drink large quantities of water or milk. Follow with milk of magnesia or vegetable oil, and call a physician immediately.
CHEMICAL HAZARD: Battery electrolyte contains sulfuric acid. Contact with eyes or skin, even through clothing, may cause severe burns. Wear a faceshield and protective clothing.
DC CIRCUIT PROTECTOR
OFFON
Start the engine.
The C type cannot be used for both AC and DC simultaneously. An overload DC circuit will trip the DC circuit protector (push button comes out). If this happens, wait a few minutes before pushing in the circuit protector to resume operation.
The DC receptacle can be used while the AC power is in use.
2.
Page 35
33
Oil alert system
OIL ALERT INDICATOR LIGHT (RED)
The Oil Alert system is designed to prevent engine damage caused by an insufficient amount of oil in the crankcase. Before the oil level in the crankcase falls below a safe limit, the Oil Alert system will automatically shut down the engine (the engine switch will remain in the ON position).
If the Oil Alert system shuts down the engine, the Oil Alert indicator (red) will come on when you operate the starter, and the engine will not run. If this occurs, check the engine oil level (see page ).
13
Page 36
34
STOPPING THE ENGINE7.
IN NORMAL USE:
OFF
ENGINE SWITCH
OFF
PLUG
To stop the engine in an emergency, turn the engine switch to the OFF position.
Switch off the connected equipment and pull the inserted plug.
Turn the engine switch to the OFF position.
1.
2.
Page 37
35
Be sure the fuel cap vent lever and the engine switch are "OFF" when stopping, transporting and/or storing the generator.
OFF
OFF
FUEL CAP VENT LEVER
SPECIAL CABLE FOR PARALLEL OPERATION (SOLD SEPARATERY)
Turn the fuel cap vent lever fully counterclockwise to the "OFF" position.
When parallel operation has been executed, pull the special cable for parallel operation.
3.
4.
Page 38
36
MAINTENANCE8.
Shut off the engine before performing any maintenance. If the engine must be run, make sure the area is well ventilated. The exhaust contains poisonous carbon monoxide gas.
Use genuine USR parts or their equivalent. The use of replacement parts which are not of equivalent quality may damage the generator.
Maintenance Schedule
The purpose of the maintenance and adjustment schedule is to keep the generator in the best operating condition. Inspect or service as scheduled in the table below.
REGULAR SERVICE PERIOD (3) Item Performed at every indicated month or operating hour interval, whichever comes first.
Each use Every
3 months
or
50 hrs.
(1)
Engine oil
Air cleaner
Spark plug
Spark arrester Valve Clearance Combustion chamber Fuel tank & filter Fuel line
Check level Change Check Clean Check-adjust Replace Clean Check-adjust Clean
Clean Check
After every 300 hrs (2)
Every year (2)
Every 2 years (Replace if necessary) (2)
Every
6 months
or
100 hrs.
Service more frequently when used in dusty areas. These items should be serviced by your servicing dealer, unless you have the proper tools and are mechanically proficient. Refer to dealer shop manual for service procedures. For commercial use, log hours of operation to determine proper maintenance intervals.
First
month
or
10 hrs.
Every
2 years
or
300 hrs.
(2)
(1) (2)
(3)
Page 39
37
CHANGING OIL
Make sure to turn the engine switch and the fuel cap vent lever OFF before draining.
1.
ENGINE OIL CAPACITY:
OIL FILLER CAP
UPPER LEVEL
COVER SCREW
LEFT SIEDE MAINTENANCE COVER
OIL FILLER HOLE
Please dispose of used motor oil in a manner that is compatible with the environment. We suggest you take it in a sealed container to your local service station for reclamation. Do not throw it in the trash or pour it on the ground.
Wash your hands with soap and water after handling used oil.
Reinstall the left side maintenance cover and tighten the cover screw securely.
Refill with the recommended oil (see page ) and check the oil level.
Drain dirty oil into a container thoroughly.
Remove the oil filler cap.
Loosen the cover screw and remove the left side maintenance cover.
0.25
(0.26 US qt , 0.22 Imp qt)
Drain the oil while the engine is still warm to assure rapid and complete draining.
1.
2.
3.
4.
5.
13
Page 40
38
AIR CLEANER SERVICE
Do not use gasoline or low flash point solvents for cleaning. They are flammable and explosive under certain conditions.
Never run the generator without the air cleaner. Rapid engine wear may result.
2.
AIR CLEANER COVER
COVER SCREW
AIR CLEANER ELEMENT
LATCH TAB
LOWER TAB
ELEMENT
LEFT SIDE MAINTENANCE COVER
A dirty air cleaner will restrict air flow to the carburetor. To prevent carburetor malfunction, service the air cleaner regularly. Service more frequently when operating the generator in extremely dusty areas.
Loosen the cover screw and remove the left side maintenance cover. Press the latch tab on the top of the air cleaner body, and remove the air cleaner cover. Wash the element in a non-flammable or high flash point solvent and dry it thoroughly. Soak the element in clean engine oil and squeeze out the excess oil. Reinstall the air cleaner element and the cover. Reinstall the air cleaner cover by inserting the lower tabs, and the latch tab. Reinstall the left side maintenance cover and tighten the cover screw securely.
3.
1.
2.
4.
5.
6.
7.
Page 41
39
SPARK PLUG SERVICE
RECOMMENDED SPARK PLUG:
3.
HANDLE BAR
PLUG WRENCH
SPARK PLUG CAP
SPARK PLUG MAINTENANCE COVER
To ensure proper engine operation, the spark plug must be properly gapped and free of deposits.
Remove the spark plug cap. Clean any dirt from around the spark plug base. Use a spark plug wrench to remove the spark plug.
CR4HSB (NGK) U14FSR-UB (DENSO)
Remove the spark plug maintenance cover.1.
2.
3.
4.
Page 42
ʵ ʵ
ʵ
ʵ
40
The spark plug must be securely tightened. An improperly tightened plug can become very hot and possibly damage the generator. Never use a spark plug with an improper heat range.
0.60 0.70 mm (0.024 0.028 in)
Visually inspect the spark plug. Discard it if the insulator is cracked or chipped. Clean the spark plug with a wire brush if it is to be reused. Measure the plug gap with a feeler gauge. Correct as necessary by carefully bending the side electrode. The gap should be:
After a new spark plug has been seated by hand, it should be tightened 1/2 turn with a wrench to compress its washer. If a used plug is being reinstalled, it should only require 1/8 to 1/4 turn after being seated.
Install the spark plug carefully, by hand, to avoid cross-threading.
Reinstall the spark plug cap on the spark plug securely. Reinstall the spark plug maintenance cover.
0.60 0.70 mm (0.024 0.028 in)
5.
6.
7.
8.
9.
10.
Page 43
41
SPARK ARRESTER MAINTENANCE
The spark arrester must be serviced every 100 hours to maintain its efficiency.
If the generator has been running, the muffler will be very hot. Allow it to cool before proceeding.
4. (Equipped type)
6 mm BOLTS
MUFFLER PROTECTOR
5 mm SCREW
MUFFLER GASKET
SPARK ARRESTER
MUFFLER
Remove the three 6 mm bolts, and remove the muffler, the spark arrester and the muffler gasket.
Remove the four 5 mm screws, and remove the muffler protector.1.
2.
Page 44
42
Use a brush to remove carbon deposits from the spark arrester screen. Inspect the spark arrester screen for holes or tears. Replace if necessary.
Check the muffler gasket; replace if damaged. Reinstall the muffler gasket, the spark arrester, the muffler and the muffler protector in the reverse order of removal.
3.
4.
Page 45
43
TRANSPORTING/STORAGE
9.
Do not drive on a rough road for an extended period with the generator on board. If you must transport the generator on a rough road, drain the fuel from the generator beforehand.
Avoid a place exposed to direct sunlight when putting the generator on a vehicle. If the generator is left in an enclosed vehicle for many hours, high temperature inside the vehicle could cause fuel to vaporize resulting in a possible explosion.
Do not operate the generator while it is on a vehicle. Take the generator off the vehicle and use it in a well ventilated place.
Do not overfill the tank (there should be no fuel in the filler neck).
When transporting the generator:
Gasoline is extremely flammable and is explosive under certain conditions. Perform this task in a well ventilated area with the engine stopped. Do not smoke or allow flames or sparks in the area during this procedure.
To prevent fuel spillage when transporting or during temporary storage, the generator should be secured upright in its normal operating position, with the engine switch OFF. The fuel cap vent lever is turned fully counterclockwise to the" OFF" position.
Drain the fuel.
Be sure the storage area is free of excessive humidity and dust.
Before storing the unit for an extended period:
Drain all gasoline from the fuel tank into an approved gasoline container.
1.
2.
a.
Page 46
ʵ
˓
44
STARTER GRIP
SCREW DRIVER
Turn the engine switch ON, and loosen the carburetor drain screw and drain the gasoline from the carburetor into a suitable container. With the drain screw loosened remove the spark plug cap, and pull the starter grip 3 to 4 times to drain the gasoline from the fuel pump. Turn the engine switch to the OFF position, and tighten the drain screw securely. Reinstall the spark plug cap on the spark plug securely.
Change the engine oil. Remove the spark plug and pour about a tablespoon of clean engine oil into the cylinder. Crank the engine several revolutions to distribute the oil, then reinstall the spark plug. Slowly pull the starter grip until resistance is felt. At this point, the piston is coming up on its compression stroke and both the intake and exhaust valves are closed. Storing the engine in this position will help to protect it from internal corrosion.
3.
4.
5.
b.
c.
d.
e.
Page 47
45
TROUBLESHOOTING
10.
When the engine will not start:
Is there fuel in the tank?
Refill the fuel tank.
Is the enough oil in the engine?
Is the engine switch on?
Turn the engine switch on.
Add the recommended oil.
Is the spark plug in good condition?
Clean, readjust gap and dry the spark plug. Replace it if necessary.
If the engine still does not start, take the generator to an authorized
dealer.
NO
NO
NO
YES
YES
YES
NO
YES
Page 48
46
Appliance does not operate:
No electricity at the DC receptacle:
Is the Output indicator ON?
Is the DC circuit protector on?
Take the generator to an authorized dealer.
Turn the DC circuit protector on.
Take the generator to an authorized
dealer.
Is the Overload indicator ON?
Check the electrical appliance or equipment for any defects.
Take the generator to an authorized dealer.
Replace the electrical appliance or equipment. Take the electrical appliance or equipment to an electrical shop for repair.
Stop and restart the engine.
NO
NO
NO
YES
YES
YES
NO DEFECTS
DEFECTS
Page 49
ʷ ʷʷ
47
SPECIFICATIONS11.
Dimensions and Weight
Engine
450 mm (17.7 in)
Model Description code Length Width Height Dry weight
EZGA
240 mm (9.4 in)
380 mm (15.0 in)
13 kg (29 lbs)
GXH50
4-stroke, overhead valve, single cylinder
50 cm
(3.1 cu-in)
41.8 36.0 mm (1.64 in 1.42 in)
8.0:1
Forced air
Full transistor
0.25
(0.26 US qt , 0.22 Imp qt)
EV10i
5,500 rpm (with eco throttle switch OFF)
2.3
(0.61 US gal , 0.51 Imp gal)
Model Engine type Displacement Bore Stroke Compression ratio Engine speed Cooling system Ignition system Oil capacity Fuel tank capacity Spark plug CR4HSB (NGK)
U14FSR-UB (DENSO)
Page 50
48
Generator
Noise
CONTROL PANEL
Center
1.60 m
1.0 m
Microphone point
EV10i
G, GW, B, F, W U
230 240
50 50
3.9 3.8 900
1,000
EU10i
G, GW, B, F, W U
72 dB
87 dB
Model
Type Sound pressure level (Lp ) According to 98/37/EC
Guaranteed sound power level (L ) Tested by 2000/14/EC
Model
Type
AC output
DC rated output
Only for charging 12 V
automotive batteries.
12 V, 8 A
Rated voltage (V) Rated frequency (Hz) Rated Ampere (A) Rated Output (VA) Max Output (VA)
Specifications are subject to change without notice.
A
W
Page 51
49
WIRING DIAGRAM12.
AC Noise Filter AC Output Receptacle Capacitor Composite Socket Control Panel Block DC Diode DC Noise Filter DC Output Receptacle DC Winding Eco throttle switch Engine Block Engine Ground Engine Switch Exciter Winding Frame Block Frame Ground Generator Block Ground Terminal Ignition Coil Inverter Unit Main Winding Oil Alert Indicator Overload Indicator Oil Level Switch Pulser Coil Output Indicator Spark Plug Spark Unit Stepping Motor Sub Winding
AC, NF ACOR Ca Cot CPB DC, D DC, NF DCOR DC, W EcoSw EgB EgG ESw ExW FrB FrG GeB GT IgC IU MW OAL Ol OLSw PC PL SP SpU StpM SW
Page 52
50
BLACK YELLOW BLUE GREEN RED WHITE BROWN LIGHT GREEN GRAY LIGHT BLUE ORANGE PINK
Bl Y Bu G R W Br Lg Gr Lb O P
ECOTHROTTLE SWITCH
ENGINE SWITCH
OFF ON
OFF
ON
G Bl
R/W R/Y ECO
OFF
ON
Page 53
51
G, GW, B, F, W type
Page 54
52
U type
Page 55
53
RECEPTACLE
Shape
Type
B
W
F
U
G, GW
Loading...