UROVO TECHNOLOGY I9100 User Manual

0 (0)

FCC WARNING

Declaration

This device (FCC ID: SWSI9100) complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) the device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

This equipment has been tested and found to comply with the limits for a Class B digital d evice, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasona ble protection against harmful

interference in a residential installation. This equipment generates, uses and can radiate r adio frequency and, if not installed and used in accordance with the instructions, may cau se harmful interference to radio

communications. However, there is no guarantee that interference will not occur in a partic ular installation. If this equipment does cause harmful interference to radio or television re ception, which can be determined by

turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

--Reorient or relocate the receiving antenna.

--Increase the separation between the equipment and receiver.

--Connect the equipment into an outlet on a circuit different from that to which the receive r is connected.

--Consult the dealer or an experienced radio/TV technician for help.

Warning:

Changes or modifications made to this equipment not expressly approved by unitech may void the FCC authorization to operate this equipment.

The device complies with the RF Exposure requirements when the devices. If use near th e body is maintained at a minimum separation distance of 1.0 cm using a device holster/c ase which is not composed of mental components or is operated at more than

1.0cm from the body.

The Specific Absorption Rate (SAR) is the unit of measurement for the amount of radio fre quency energy absorbed by the body when using a device. The SAR value is determined at the highest certified power level in laboratory conditions, but the actual SAR level of the device when being operated can be well below the value.

This is because the device is designed to use the minimum power required to reach the n etwork. The SAR limit adopted by USA and Canada is 1.6 watts/kilogram (W/kg) averaged over one gram of tissue. The Highest SAR value reported under this

standard product certification for use close to the body is 1.407 W/kg, hotspot mode is 1.436W/kg