![](/html/9c/9ca8/9ca89932d3b6d616e6599058225b7949c0b53041103fabd213aff4a3097975e4/bg1.png)
INSTRUCTION MAN UAL
L
ow
B
attery
LO NORM HI
Certified J2791
Mute
Sens.
R
LD15
Display # Leak Size
(oz/yr)
1-3 < 0.1
4-6 0.1 to 0.5
7-9 > 0.5
8
L
E
A
K
S
I
Z
E
REFRIGERANT DETECTOR
™
L
ow
B
attery
LO NORM HI
Certified J2791
8
L
E
A
K
S
I
Z
E
Mute
Sens.
8
L
E
A
K
S
I
Z
E
Mute
Sens.
8
L
E
A
K
S
I
Z
E
Mute
Sens.
D
isplay # Leak Size
8
L
E
A
K
S
I
Z
E
Replace w/
New Filter
Remove
O
ld (Dirty) Filter
U
nscrew
Sensor Tip
Unscrew
Sensor Tip
F
ilter
P
ull Straight Apart
DO NOT TWIST!
1.)
2.)
S
crew On
S
ensor Tip
Filter
Push Straight Together
DO NOT TWIST!
DO NOT
T
W
IST
!
A
lign New Sensor With Tip
And Push Straight On.
RLD15
FEATURES
LEAK SIZE INDICATOR
he digital leak size indicator remains off
T
until a leak is detected, a number from 1 - 9
will be displayed for all HFC and HCFC refrigerants.
Regardless of the sensitivity settings.
: Refrigerant Leak Detector
AGENT
The number will increase or decrease
depending on the amount of refrigerant
sensed. The maximum value will be displayed
once the leak source has been located.
FILTER REPLACEMENT
1. Replace Filter: Unscrew sensor tip as
hown to replace filter. Replace filter
s
whenever it becomes visibly dirty or every
2 to 3 months depending on use.
1-800-547-5740 • Fax: (503) 643-6322
www.ueitest.com
email: info@ueitest.c
INTRODUCTION
The AGENT RLD15 features a long life
heated sensor technology that is designed to
detect the more current and difficult HFC
refrigerants such as R134a, R410A, R404A,
R407C, in additiion to all HCFC (R22) and CFC
(R12) refrigerants including SNAP approved
hydrocarbon blends.
GETTING STARTED
1. TURN ON:
Press
Power Button
2. WARM UP:
Allow 20 sec.
to warm up.
(Indicator will
blink and alarm
will beep)
3. READY:
When the flashing
“8” stops and the
green sensitivity
indicator LED
turns on
LEAK TEST VIAL
The Leak detector comes with a Leak Test
Vial that allows the user to make sure the
detector is performing properly. To test: Turn
the detector on and allow the unit to warm-up.
1. Remove Seal Cap
The beep rate should
3.
increase and the Digital
Leak Size Indicator
should display a number
from 4 - 6 indicating that
the sensor and electronics are working properly
4. Replace Seal Cap
replace plastic seal cap after leak
test is completed. Replace Test
Vial when the blue color is no
longer visible.
NOTE: Always remember to
2. Place Sensor tip close to
open vile.
Approximate Size Indications
Maximum # Displayed
1-3
4-6
7-9
Leak Size (oz/yr)
< 0.1
0.1 - 0.5
> 0.5
1.) Remove sensor by unscrewing sensor tip
nd pulling out the socket.
a
AUDIO MUTE FUNCTION
SENSOR REPLACEMENT
2.) Install the new sensor by aligning the mark
on the sensor cover with that on the probe and
pressing together.
om
ress Mute
1.P
Button to
Mute Speaker.
SENSITIVITY LEVEL
1. Press Sens.
utton to
B
Change / Scroll
Sensitivity
Levels.
(Indicated
By LED)
LOW BATTERY INDICATOR
Replace batteries when flashing
BATTERY REPLACEMENT:
1. Remove battery cover on back of
instrument. (Fig1)
2. Replace batteries (4 AA) with correct
polarity.
Misalignment can damage the sensor pins.
WARNING
FORCE
OR
DO NOT
SENSOR INTO THE SOCKET.
TWIST
THE
(Fig1)
SPECIFICATIONS
Model #
Name
Sensitivity
Sensor Life
Response Time
Power Supply
Battery Life
LIMITED WARRANT Y
RLD15
The AGENT is warranted to be free from defects in
materials and workmanship for a period of three years
from the date of purchase. If within the warranty period
your instrument should become inoperative from such
defects, the unit will be repaired or replaced at UEi’s
option. This warranty covers normal use and does not
cover damage which occurs in shipment or failure which
results from alteration, tampering, accident, misuse,
abuse, neglect or improper maintenance. Batteries and
consequential damage resulting from failed batteries are
not covered by warranty.
Any implied warranties, including but not limited
to implied warranties of merchantability and fitness for
a particular purpose, are limited to the express
. UEi shall not be liable for loss of use of the
warranty
instrument or other incidental or consequential dam
ages, expenses, or economic loss, or for any claim or
claims for such damage, expenses or economic loss.
A purchase receipt or other proof of original purchase
date will be required before warranty repairs will be
rendered. Instruments out of warranty will be repaired
(when repairable) for a service charge. Return the unit
postage paid and insured to:
-
Probe Length
Numerical Display
eight, lbs
W
arranty
W
Cross Sensitivity to Automotive Chemicals
Some Automotive solvents and chemicals
have similar hydrocarbon properties as R134a
and may elicit a positive response (< 30 seconds)
from the AGENT. Before leak detecting, clean
up any chemicals in the list below that elicit a
response.
Dextron Transmission Fluid heated to 160˚F
Quaker State motor oil heated to 160˚F
Rain-X Windshield wash fluid
Ford silicone lubricant
Ford Gasket adhesive (when wet)
Ford rust inhibitor (when wet)
Loctite Natural Blue Degreaser (undiluted)
Ford brake parts cleaner (when wet)
Ford silicone rubber (when uncured)
Motorcraft antifreeze heated to 160˚F
Gunk liquid wrench (when wet)
ime
arm-Up T
W
Ford spot remover (when wet)
UEi
PLEASE
8030 SW Nimbus A
Copyright © 2009 UEi RLD15-MAN 3/09
Beaverton, OR 97008
ve.
RECYCLE
Ford pumice lotion (with mineral solvent)
Ford motorcraft brake fluid
Ford carburetor cleaner (when wet)
RLD15
AGENT 1
.05 oz/yr R134a
.025 oz/yr R22
> 300 Hours
≤ 1sec
4 AA Alkaline
8 Hrs. Continuous
<20 Seconds
17 inches
7 Segment Digital (1-9)
1.5 Lbs
3yr (Includes Sensor)