Safety advice, standards and guidelines3
General Information4
Applications5
Build6
Characteristics6
Technical data7
Dimensions compact device8
Dimensions transformers and chokes8
Dimensions multiple-axes combination9
Connections11
Connection diagram12
EMC - advice13
Connections - isolating transformer, compact device X314
Connections - mains module X10, motor power15
Connection advice16
Command value17
Current limiting18
Actual value connections19
Signals - drive ready BTB, analog parameter measurement20
Terminal connections21
Components22
Circuit diagram23
Adjustments25
Adjustment advice26
Command value integrator27
Speed actual value29
Current limiting30
Speed control loop circuit31
Adjustment without measurement equipment31
Standard set-up32
Commissioning33
Faults34-35
Signals36
Protocol37
Guarantee38
Encoder connections39
Page
2
1 Basic - Information
Electronic equipment is not fault proof. This fact should be borne in mind for all possible
operating conditions.
ATTENTION -High voltage
AC 140V~, DC 220V=
Before installation or commissioning begins, this manual must be thoroughly read and
understood by the technical staff involved.
If any uncertainty arises, the manufacturer or dealer should be contacted.
TVD3.2 devices are power electric parts used for regulating energy flow for power plants.
Protection rating IP00.
Standards and Guidelines
The device and its associated components can only be installed and switched on where
the local regulations and technical standards have been strictly adhered to:
EU Guidelines89/392/EWG, 84/528/EWG, 86/663/EWG, 72/23/EWG
- loss of regulation or control
the axis will be safely de-activated.
It must also be ensured that the machine or equipment are fitted with device independent
monitoring and safety features.
Setting Adjustments
- should only be carried out by suitably trained personnel
- should only be carried out in accordance with health and safety guidelines
Installation
- should only be carried out when all voltages have been removed.
QS
Test results are archived with the device serial number by the manufacturer.
CE
The device adheres to the following: Guideline EU 89/336/EWG. EMV standards
EN61000-2 and EN61000-4.
TVD3.2bl3
Servo - Drive TVD3.2 -xx- bl
General Information
General Information
The transistor 3-phase current servo amplifier SERVO-TVD3.2 in combination with the
brushless dc motor (ac synchro servo motor, EC motor provide a drive solution free of
maintenance and with a wide dynamic control range.
The drive displays the well-known good control characteristics of dc drives without the
disadvantages of the carbon brushes’ wear and the commutation limits.
The rotor moment of inertia is notably lower and the limit power is greater than with
equally constructed dc motors. This results in up to 5 times higher acceleration values.
The generated heat in the motor only occurs in the stator (cold shaft).
The motors always have the protection rating IP 65.
From the electrical view, the ac synchro motor is a synchro motor with a permanent
magnet rotor and a three-phase current stator.
The physical characteristics correspond to those of dc motors, that is, the current is
proportional to the torque and the voltage is proportional to the speed.
Current and voltage are precisely measured. The analogue circuits are simply
constructed.
It is possible to control the speed via the motor voltage, however, in order to achieve the
best control precision, always the tacho control is used.
The speed actual value is generated in the rotor position encoder plus bl-tacho.
The difference of the command value and the actual value is amplified in the speed
control loop circuit (P-I-controller) of the servo drive. This results in the current command
value, which is transferred to the three phase current controllers by means of the rotor
position signal. In the course of this the stator magnetic field leads the rotor magnetic
field by 90° electrically.
This field frequency is not controllable, it is automatically adjusted.
The motor currents are trapezoidal.
For dc and ac synchro servo amplifiers which are supplied by a dc bus, it must be
checked that the energy is fed back into the bus during brake operation (winding
machines, lifts, great centrifugal masses).
The ballast circuitry is rated for 3% duty cycle. An extended operating time can be
achieved by additional external resistors. (Option)
Information:
For motors
with incremental encoderUNITEK TVD3-2-xx-IN
with resolverUNITEK TVD3-2-xx-RS
with rotor position encoderUNITEK TVD3-2-xx-bl
For low-voltage applicationsUNITEK TVD3-230-xx-bl,IN,RS
For high powerUNITEK TVD6-2 -bl,IN,RS
200V/400V up to 25/40A
For digital servo controllersUNITEK DS 400
200V/400V up to 50/100A
4
1 Basic - Information
Applications
Machines and installations for all types with a drive power of up to 0.8kW.
Especially as 4Q-servo-drive for feed axes where the following is required:
- high dynamic acceleration and braking cycles
- a wide control range
- high efficiency
- small motor dimensions
- highly repeatable, accurate and quiet moves
- ‘cold shaft’
For speed or torque control or combined speed/torque control incorporated within or
independent of position control loops.
Drives with constant speed as in conveyors, spindle drives, pumps, transversal or
longitudinal pitch drives.
AC synchro-servo-drives are more compact than other electric drives.
Applications
Particularly suitable for:
component equipment inserting machines, sheet-metal working machines,
machine tools, plastic working machines, assembly machines,
knitting and sewing machines, textile working machines, grinding machines,
wood and stone working machines, metal working machines, food processing machines,
robots and handling systems, conveyors, extruders, calenders, and
many other machines and installations.
Note
Use bl-drives where braking operations are predominant, e.g. when
deceleration is mainly required:
- winding machines, lifts, great centrifugal masses
The braking energy is annihilated in the ballast circuitry or fed into the
mains through the use of an external dc bus converter.
Energy compensation is possible for drives with several axes.
Motor features
- protection rating IP 65
- compact
- suitable for rough surroundings
- suitable for high dynamic overload
- free of maintenance
TVD3.2bl5
Servo - Drive TVD3.2 -xx- bl
Build
Build
- Switch cabinet mounting or 3HE plug-in device
according to the VDE, DIN and EU regulations
- Standard analog control electronics
- Power electronics for 5A and 10A
- No galvanic isolation between the power connection and device
ground (GND)
GND = -UB = PE - housing
Components
- IGBT power semiconductors, comfortably over-dimensioned
- Only components customary in trade and industrially standardised are used
- SMD basic equipment
- LED displays
- 4 position binary switches for system set-up
- Precision potentiometers for fine adjustment
Characteristics
*Connection using an isolating transformer nom. 115V~ (max. 140V~)
*Differential command value input
*Speed and torque control
*Static and dynamic current limiting
*Current command value output
*Measurement points for current and speed
*Enable logic
*Emergency stop
*Braking in case of a mains failure
*Temperature watchdog for the motor and the device
6
1 Basic - Information
Technical Data
Power connection
- Compact device
with transformernominal115V~ (max. 140V~),20V~/24V=
with transformer + rectifiernominal180V= (max. 200V=),20V~/24V=
- For a multiple axes mounting with mains module
transformer1x or 3x115V~ (max.140V~) plus
Power supplyV~1x or 3x 115V~ plus 1x 20V~/24V=
Output voltageV=max.200
Output currentA=max.30
Regen circuit withV=220
Ballast powerW100%50
WS6000
Technical Data
Common specification
Protection ratingIP 00
FormatVDE 0100 group C, VDE 0160
Humidity ratingclass F acc. to DIN 40040
Site of installation< 1000m above sea level
Operating temperature range0 ... 45°C
Extended operating temp. rangeup to 60°C reduced by 2%/°C
Storage temperature range-30°C to + 80°C
Speed control loop circuit
- control precision without actual value error± 0.5%
- control range1: 1000
Caution: The maximum connection voltages 140V~, 200V=
must not be exceeded even for short times.
The regen circuit may be destroyed.
TVD3.2bl7
Servo - Drive TVD3.2 -xx- bl
Compact device
Compact device dimensions
Transformer dimensions
Transf.
typ
e
TE 8/210085x 89x 822.0
TE 12/1250120x101x1154.3
TE 12/3400120x133x1156.8
TE 15/1500108x132x1228.2
TE 15/3800150x150x13213.5
TE 74/21300175x140x16015.4
TE 74/31600175x150x16018.5