CONTENTS
A. Introduction
B. Safety Rules
C. International Electrical Symbols
D. Feature
E. Specification
F. Operation Plate
G. Make Measurement
H. Fuse and battery replacement
I. Accessories
Remark:
The model of UT30B,UT30C,UT30D will be marked as UT30BL,UT30CL
UT30DL,if they have backlight function.
1
Model UT30B/C/D/F: OPERATING MANUAL

Summary of UT30 Series DMM
A.Introduction
UT30 series Multimeter is 3 1/2 digits with steady operations,fashionable
structure and highly reliable hand-held measuring instrument. The meter
can measure DC/AC voltage, DC/AC current, Resistance, Frequency,
Temperature, Diode, Transistor hFE, and Continuity. It is an ideal tool for
maintenance.
2
Model UT30B/C/D/F: OPERATING MANUAL

B. Safety Rules(1)
CAUTION-FOR CONTINUED PROTECTION AGAINST FIRE, REPLACE
ONLY WITH FUSE OF THE SPECIFIED VOLTAGE AND CURRENT
RATINGS.
l Do not operate the meter unless the bottom case has been closed as
terminal can carry voltage.
l Inspect the insulation of the test leads and make sure there is no
damage to the test leads before using the meter.
l As soon as the battery indicator’s” “±appear, replace the battery to
ensure accurate readings.
l Set the meter to suitable function and range before each measurement.
l Tested values over the maximum range of each measurement can
cause damages to the meter or electric shock to users.
l To avoid damages of the meter, do not turn the rotary switch during
measurement.
l When measuring voltage higher than DC 60V or AC 30Vrms, pay
extra attention to avoid electric shock.
3
Model UT30B/C/D/F: OPERATING MANUAL

l Make sure to replace right type and right rating fuse.
l Do not operate or store the Meter under high temperature or humid
condition.
l Do not change internal circuit to avoid damages to the meter and
danger to the user.
l Periodically wipe the case with damp cloth and mild detergent. Do not
use abrasives and solvents.
l The meter is designed to withstand the stated maximum voltages.
If it’s not possible to exclude, without doubts, that impulses, transients,
disturbance or for other reasons these voltages are exceeded, a
suitable prescaler (1:10) must be used.
B. Safety Rules(2)
4
Model UT30B/C/D/F: OPERATING MANUAL

C. International Electrical Symbols
Low Battery Earth Ground
Warning
Double Insulation
AC current
Diode
DC current
Buzzer
Fuse
AC or DC
5
Model UT30B/C/D/F: OPERATING MANUAL

D.General Specifications(1)
1. The maximum voltage, between any terminal and earth, is 600Vrms.
A . The“COM”input terminal is always connected with the black test
lead.
B . The“V,ohm, mA”input terminal is always connected with the red
test lead and is used to measure voltage up to 500V,resistance
and current up to 200mA.
C . The“10A MAX”input terminal is always connected with the red test
lead and is used to measure current greater than 200mA but no
more than 10A.
2.
10A Terminal: non-fused
3.
mA Terminal Fuse: ø5x20-0.3A 250V.(Fast)
4. Maximum Display is 1999,and updates two or three times every second.
5. Over range display is “1” or “OL”. (Only UT30F).
6
Model UT30B/C/D/F: OPERATING MANUAL

D.General Specifications(2)
6. Temperature:
Operating: 0
o
C-40oC (32 oF-104 oF)
Storing:-10
o
C-50oC (14 oF -122 oF)
7. Altitude:
Operating:2000m
Storage:10000m
8 Relative humidity:Max.relative humidity 80% for temperature up to
31
o
C decreasing linearly to 50% relative humidity at 40oC.
9. Battery: 9V NEDA 1604 or 6F22 or 006P.
10. Low Battery Indication: Display “ ”.on LCD.
11. Dimension:75mmx130mmx36mm
12. Weight: approx. 150g(Test Leads not included)
7
Model UT30B/C/D/F: OPERATING MANUAL

E.Specification(1)
Accuracy: (a% reading + b digit), which guarantee one year.
Environmental Temperature:23
o
C 5oC
Relative Humidity: <75%
Input Impedance:10MΩ for all the ranges.
Overload protection: At 200mV range, it’s protected at 230V(AC / DC
Current), others are protected at 500V(AC or DC).
Range
Resolution
Accuracy
200mV
2000mV(2V)
20V
200V
500V
100µV
1mV
10mV
100mV
1V
UT30B UT30C UT30D UT30F
(0.5%+2)
(0.8%+2)
1. DC Voltage
8
Model UT30B/C/D/F: OPERATING MANUAL

E.Specification(2)
2. AC Voltage
Input Impedance: (approx. 5MΩ ) of UT30B\C\D, but all ranges of
UT30F are 10MΩ .
Frequency: 40-400Hz
Display: RMS of Sine Wave Value (Average Value)
Overload protection: At 200mV range, it is protected at 230V(AC / DC
Current), others are protected at 500V(AC or DC )
Range Resolution
Accuracy
200mV
2V
20V
200V
500V
100µV
1mV
10mV
100mV
1V
UT30B UT30C UT30D UT30F
(1.2%+10)
(1.2%+3)
(1.2%+3)
(1%+3)
9
Model UT30B/C/D/F: OPERATING MANUAL

E.Specification(3)
Range Resolution
Accuracy
200µA
2000µA(2mA)
20mA
200mA
10A
100nA
1µA
10µA
100µA
10mA
UT30B UT30C UT30D UT30F
(1.2%+2)
(2%+5)
(1%+2)
Overload Protection: 0.3A/250V fuse, No fuse at 10A,measuring time
limit is equal to or less than 10 seconds, and time interval should be equal
to or over 15 minutes.
Measuring voltage drop: Full range is 200m V.
3. DC Current
10