UNI-T UT232 Operating Manual

Page 1
Model UT232
OPERATING MANUAL
Page 2
TABLE OF CONTENTS TITLE PAGE
Model UT232: OPERATING MANUAL
1
3 3 4 4 6 7 7 8 9 12 14 14 16 18 25 27 29 31 32
Page 3
2
32 33 34 34 34 35 35 36 37 38 38 39 39 39 40
Model UT232: OPERATING MANUAL
TABLE OF CONTENTS TITLE PAGE
A. General Specifications B. Environmental Requirements Accuracy Specifications A. AC Voltage B. Frequency C. AC Current D. Active Power E. Apparent Power F. Reactive Power G. Power Factor H. Phase Angle I. Active Energy Maintenance A. General Service B. Replacing the Battery
Page 4
3
Model UT232: OPERATING MANUAL
This Operating Manual covers information on safety and cautions. Please read the relevant information carefully and observe all the Warnings and Notes strictly.
Warning
To avoid electric shock or personal injury, read the ìSafety Informationî and ìRules for Safe Operationî carefully before using the Meter.
Model UT232 is a three phase intelligent handheld
digital power clamp meter (hereafter referred to as ìthe Meterî) which has both the features of digital current meter and also power measurement meter.
The Meter can measure Voltage, Current, Active Power , Apparent Power, Reactive Power , Power Factor, Phase Angle, Frequency, Active Energy and etc.
Open the package case and take out the Meter. Check the following items carefully to see any missing or damaged part:
Item
1 2 3 4 5 6 7 8 9 10 11 12 13
Description
English Operating Manual Red Test Lead Black Test Lead Blue Test Lead Yellow Test Lead Red Alligator Clip Black Alligator Clip Blue Alligator Clip Yellow Alligator Clip USB Interface Cable Software Tool Box
1.5V Battery (LR6)
Qty
1 piece 1 piece 1 piece 1 piece 1 piece 1 piece 1 piece 1 piece 1 piece 1 piece 1 piece 1 piece 4 pieces
In the event you find any missing or damage, please contact your dealer immediately.
Overview Unpacking Inspection
Page 5
4
Model UT232: OPERATING MANUAL
Safety Information
This Meter complies with the standards IEC61010: in pollution degree 2, overvoltage category (CAT. III 600V, CAT IV 300V) and double insulation.
CAT. III: Distribution level, fixed installation, with smaller transient overvoltages than CAT. IV CAT.IV: Primary supply level, overhead lines, cable systems etc.
Use the Meter only as specified in this operating manual, otherwise the protection provided by the Meter may be impaired.
In this manual, a Warning identifies conditions and actions that pose hazards to the user, or may damage the Meter or the equipment under test.
A Note identifies the information that user should pay attention to.
International electrical symbols used on the Meter and
l
l
l l
in this Operating Manual are explained on page 6.
Rules For Safe Operation
Warning
To avoid possible electric shock or personal injury, and to avoid possible damage to the Meter or to the equipment under test, adhere to the following rules:
Before using the Meter inspect the case. Do not use the Meter if it is damaged or the case (or part of the case) is removed. Look for cracks or missing plastic. Pay attention to the insulation around the connectors. Inspect the test leads for damaged insulation or exposed metal. Replace damaged test leads with identical model number or electrical specifications before using the Meter. Do not apply more that the rated voltage, as marked on the Meter. When measurement has been completed, disconnect the connection between the test leads and the circuit under test, remove the
Page 6
5
Model UT232: OPERATING MANUAL
l
l l l
l l l
testing leads away from the input terminals of the Meter and turn the Meter power off. Do not carry out the measurement when the Meterís back case and / or battery door is opened to avoid electric shock. When the Meter working at an effective voltage over 30V in AC, special care should be taken. Use the proper terminals and function for your measurements. Do not use or store the Meter in an environment of high temperature, humidity, explosive, inflammable and strong magnetic field. The performance of the Meter may deteriorate after dampened. Do not use the Meter if the surface of it is wet or the userís hands are wet. When using the test leads, keep your fingers behind the finger guards. Replace the battery as soon as the battery indicator appears. With a low battery, the Meter might produce false readings that can lead to electric shock and personal injury.
l l
l
l
l l
l
When opening the battery door, must make sure the Meter is power off. When servicing the Meter, use only the same model number or identical electrical specifications replacement parts. The internal circuit of the Meter shall not be altered at will to avoid damage of the Meter and any accident. Soft cloth and mild detergent should be used to clean the surface of the Meter when servicing. No abrasive and solvent should be used to prevent the surface of the Meter from corrosion, damage and accident. The Meter is suitable for indoor use. Turn the Meter off when it is not in use and take out the battery when not using for a long time. Constantly check the battery as it may leak when it has been using for some time, replace the battery as soon as leaking appears. A leaking battery will damage the Meter.
Page 7
6
Model UT232: OPERATING MANUAL
International Electrical Symbols
AC (Alternating Current) Grounding Double Insulated Warning. Refer to the Operating Manual Deficiency of Built-In Battery Danger of High Voltage Conforms to Standards of European Union
Page 8
7
Model UT232: OPERATING MANUAL
Figure 1
1
2
3 4 5 6 7
8 9
10
11 12 13
Transformer Jaw: designed to pick up the AC and DC current flowing through the conductor. It could transfer current to voltage. The tested conductor must vertically go through the Jaw center. Hand Guards: to protect userís hand from touching the dangerous area. Power button Max/ button MENU button LOAD button (recall data) SELECT button (press to select alternate function and sum of Watts measurement) MIN/ button V3 Input Terminal (Third phase measurement) V2 Input Terminal (Second phase measurement) V1 Input Terminal (First phase measurement) COM Input Terminal CLEAR button (maximum and minimum)
Black Red Blue Yellow
The Meter Structure
A. The Meter Front Structure (see figure 1)
Page 9
8
Model UT232: OPERATING MANUAL
1 Infrared slot 2 USB Interface Cable
Figure 2
14 15 16 17 18 19 20
button (Sum) SAVE button (data store button) USB button LIGHT button (auto display backlight button) HOLD button LCD Display Testing Leads (Red, Black, Blue and Yellow)
B. The Meter Back and Bottom Structure
(see figure 2)
Page 10
9
Model UT232: OPERATING MANUAL
Functional Buttons
Below table indicated for information about the functional button operations.
Button POWER
HOLD
LIGHT
MENU
Operation Performed
Press and hold POWER for 1 second to turn the Meter on. Press POWER again to turn the Meter off. Press HOLD to enter the Hold mode in any mode,
appears and
the Meter beeps. Press HOLD again to exit the Hold mode to return to measurement mode, the Meter beeps and
disappears. Press LIGHT to turn the display backlight on. The display backlight will be off automatically after 30 seconds. Press MENU to display the following functions in sequence: AC V oltage (main display) + Frequency
Button MENU
MAX/
Operation Performed
(secondary display) AC Current (main display) + AC V oltage (secondary display) Active power (main display) + Phase angle (secondary display) Apparent power (main display) + Reactive power (secondary display) Power factor (main display) + Phase angle (secondary display) Active Energy (main display) + Time (secondary display) Press to start recording of maximum value, it valid at voltage, current, active power and apparent power ranges only. Press once at LOAD mode, MR icon shown, the Meter displays the next stored reading, the left secondary display showing the index increase one. Press once at mode, CAL icon shown,
Page 11
10
Model UT232: OPERATING MANUAL
Button MAX/
USB
LOAD
Operation Performed
the Meter steps through sum of active power (main display) + sum of reactive power (secondary display) and sum of power factor (main display) + sum of apparent power. Press USB once to turn the USB interface on, USB appears and the Meter beeps. Press USB again to turn the USB interface off, USB disappears and the Meter beeps. It is invalid at active energy mode Press once to enter LOAD mode, MR appears and the Meter beeps. Press again to exit LOAD mode, MR disappears and the Meter beeps. Press and hold LOAD for 1 second to display the stored data quickly. At Active power (main display) + Phase angle (secondary display) mode, press
once button to sum up the current
Button
Operation Performed
first phase of 3 phase measurement result. Then carry out second phase power measurement. Press
again to sum up the second phase power measurement result, then carry out third phase power measurement. Press
again to sum up the third phase power measurement result, then press SELECT to enter the measurement of sum of the watts mode, the display shows the 3 phase sum of the watts value. Press once to store single reading, MEM appears and the Meter beeps. Press and hold for over 1 second to continuous store reading, MEM blinks and the Meter beeps. The index number shown on the left secondary display keep on increasing. Press SAVE again
SAVE
Page 12
11
Model UT232: OPERATING MANUAL
Button
At active power (main display) + phase angle (secondary display) mode, press SELECT button to step through first phase, second phase, third phase and sum of watts. At other mode, press SELECT to step through first phase, second phase and the third phase. Press to start recording of minimum value, it valid at voltage, current, active power and apparent power ranges only. Press once at LOAD mode, MR icon shown, the Meter displays the previous stored reading, the left secondary display showing the index decrease one. Press once at mode, CAL icon shown,
SELECT
MIN /
Button
the Meter steps through sum of active power (main display) + sum of reactive power (secondary display) and sum of power factor (main display) + sum of apparent power.
CLEAR
Operation Performed
to exit. The maximum number of data store is 99, when it achieves 99, the Meter shows FUL. Press CLEAR to clear the stored reading in order to store next reading.
Operation Performed
At active energy range, press to reset time the zero, then restart the timing. At all other ranges, press to clear stored readings.
Page 13
12
Model UT232: OPERATING MANUAL
Display Symbols (see figure 3)
Figure 3
1 2 3 4 5 6 7 8 9
10
11
Meaning
Data Output is in progress
Indicator for DC measurement
First phase symbol
Second phase symbol
Third phase symbol
Unit for hour
Unit for minute
Watt: Sum of Watt
The battery is low.
Warning: To avoid false readings, which could lead to possible electric shock or personal injury, replace the battery as soon as the battery indicator appears.
Unit for second Symbol of Unit. Hz: Hertz.The unit of frequency. PG: The unit of phase angle KVAr. The unit of reactive power
Symbol USB DC
1 2 3
h mm
W
s
Hz, PG, KVAr
Number
Page 14
13
Model UT232: OPERATING MANUAL
Number
12 13 14 15 16 17
18 19 20 21
22
23 24 25 26
Meaning
Minimum reading Analogue Bar Graph Overloading Ruler Maximum reading Indicator for clear the stored reading Ruler negative symbol High voltage symbol Indicates negative reading Indicator for AC voltage or current Indicator for recall the stored reading Frequency symbol Indicator for data store Indicator for data stored is full Data hold is active
Symbol MIN
MAX CLR
AC
MR
FREQ MEM FUL
Page 15
14
Model UT232: OPERATING MANUAL
Figure 4
Black
Red
Blue
Yellow
Measurement Operation
Preparation
Press and hold POWER for one second to turn the Meter on. The default range is the last measurement range when you turned off the Meter. Replace the battery as soon as the battery indicator ì î appears on the display.
A. AC Voltage (main display) + Frequency (secondary display) Measurement (see figure 4)
Page 16
15
Model UT232: OPERATING MANUAL
The AC Voltage ranges are:15V , 100V, 300V and 600V The frequency range is:20Hz~500Hz To measure AC voltage + frequency, connect the Meter
as follows:
1.
2.
3.
4.
Insert the red test lead into the V1 terminal, blue test lead into the V2 terminal, yellow test lead to V3 input terminal and black test lead to the COM input terminal. Press the MENU to select Voltage (main display) + Frequency (secondary display) range. Connect the red test leads (V1 input terminal), blue test leads (V2 input terminal) and yellow test leads (V3 input terminal) to the corresponding three phases loaded live wire. Black test lead (COM input terminal) to the corresponding three phases loaded neutral wire. Press SELECT to select phase location, the display shows the corresponding phase symbol. V1 means the first phase 1, V2 means the first phase 2, V3 means the first phase 3.
5.
6.
7.
8.
The display shows the corresponding True RMS voltage value and frequency value of each phase. Press MAX/ , the LCD displays MAX, it starts recording the maximum AC voltage T rue RMS value. Press MAX/ again to show the current AC voltage True RMS value. Press MIN/ the LCD displays MAX, it starts recording the minimum AC voltage T rue RMS value. Press MAX/ again to show the current AC voltage True RMS value. The display shows OL when the input voltage is higher than 600V rms.
Note
When the measurement has been completed, disconnect the connection between the testing leads and the circuit under test and remove testing leads from the input terminals.
Page 17
16
Model UT232: OPERATING MANUAL
B. AC Current (main display) + AC Voltage (secondary display) Measurement (see figure 5)
Figure 5
The AC current ranges are: 40A, 100A, 400A and 1000A The AC Voltage ranges are: 15V , 100V, 300V and 600V T o measure AC current + AC voltage, connect the Meter
as follows:
1.
2.
3.
4.
5.
Press the MENU to select AC Current (main display) + AC Voltage (secondary display) range.
Press the lever to open the transformer jaw. Center the conductor within the transformer jaw, then release the Meter slowly until the trasnformer jaw is completely closed, Make sure the conductor to be tested is placed at the center of the transformer jaw, otherwise it will casue deviation. The Meter can only measure one conductor at a time, to meausre more than one condutor at a time will cause deviation. The double display shows the AC current True RMS value and AC voltage True RMS value.
Press MAX/ , the LCD displays MAX, it starts recording the maximum AC current T rue RMS value. Press MAX/ again to show the present AC
Page 18
6.
7.
True RMS value. Press MIN/ , the LCD displays MAX, it starts recording the minimum AC current T rue RMS value. Press MAX/ , again to show the present AC current True RMS value. The display shows OL when the current of the tested conductor is higher than 1000A rms.
17
Model UT232: OPERATING MANUAL
Note
When the measurement has been completed, disconnect the connection between the conductor under test and the jaw, and remove the conductor away from the transformer jaw of the Meter.
Page 19
18
Model UT232: OPERATING MANUAL
C. Active Power (main display) + Phase Angle (secondary display) Measurement
The active power ranges are: 40A, 100A, 400A and 1000A
The phase angle ranges are: 0∞ ~360∞
Warning
To avoid damages to the Meter or harms to you, do you measure higher than AC voltage 600 v.r.s. and AC current 1000A v.r.s.
To measure active power + phase angle, connect the Meter as follows:
1.2.Press the MENU to select Active power (main display) + Phase angle (secondary display) range. Press the lever to open the transformer jaw, and clamp them to the corrresponding phase of tested conductor. If user needs to mesaure any phase of the 3 phase, then clamp them to that phaseís conductor.
3. Connecting method (see figure 6, 7, 8):
Page 20
Figure 6
Model UT232: OPERATING MANUAL
19
Black
Red
Blue
Yellow
Insert red test leads to V1 input terminal. Insert blue test leads to V2 input terminal Insert yellow test leads to V3 input terminal and connecting it to every live wire of the 3 phase. Insert black test leads to COM input terminal and connect it to the neutrual wire of the 3 phase. You must specify that this connection is used only when the main transformer have STAR connection.
Page 21
Figure 7
Model UT232: OPERATING MANUAL
20
Insert red test leads to V1 input terminal. Insert blue test leads to V2 input terminal Insert yellow test leads to V3 input terminal and connect it to every live wire of the 3 phase.
Red
Blue
Page 22
21
Model UT232: OPERATING MANUAL
Figure 8
Insert red test lead to V1, V2 or V3 input terminal corresponding to one of 1, 2 or 3 phase Insert black test leads to COM input terminal. Connecting the two test leads to live and neutual wires.
Black
Red
Page 23
22
Model UT232: OPERATING MANUAL
Figure 9
Figure 10
Figure 11
Figure 12
4. When measuring 3 phases 4 wires or 3 phases
3wires:(see figure 9, 10, 11, 12, 13, 14, 15)
Press SELECT to choose first phase 1, see figure 9. The double displays show the acitve power kW value and also the PG value of 1.
If necessary, press to get the sum of watts as figure 10.
After sum up the current power measurement value of the first phase, then press SELECT to choose the second phase 2, as figure 11
The double display shows the value of acitve power kW and PG of 2. If ncessary, press to get the sum of watts as figure
12.
Page 24
Model UT232: OPERATING MANUAL
23
Figure 14
Figure 15
Figure 13
After sum up the current power meaursuremnt value of the second phase, then press SELECT again to choose the third phase 3, as figure 13.
The double display shows the value of acitve power KW and PG of 3. If ncessary, press to get the sum of watts as figure
14.
After sum up the current power measurement value of the third phase, finally press SELECT again to display the 3 phase sum of acitve power value and reactive power value. Press MAX/ or MIN/ as figure 15 to step through in sequence three phase sum of active power+three phase sum of reacitve power, and three phase sum of power factor + 3 phase sum of apparent power.
Page 25
Model UT232: OPERATING MANUAL
24
active power, OL will be displayed when it is over than that. Press MAX/ , the display shows MAX, it starts recording the maximum active power value. Press again to display the current active power value. Press MIN/ , the display shows MIN, it starts recording the minimum active power value. Press again to display the current active power value.
6.
7.
The maximum power is 600kW of single phase, OL will be displayed when it is over than that. The maximum range is 1800kW of three phase sum of
5.
When there is no input or single phase, the Meter displays OL. button is not valid. It can only sum up the current measurement value. The maximum and minimum value cannot be summed up. Only at this range can carry out sum of watts measurement, other ranges cannot carry out this measurement. When testing has been completed, disconnect the connection between the testing leads and the circuit under test and remove testing leads from the input terminals.
Note
Page 26
Figure 17
Figure 18
25
Model UT232: OPERATING MANUAL
D. Apparent Power (main display) + Reactive Power (secondary display) Measurement
To avoid damages to the Meter or harms to you, do you measure higher than AC voltage 600V rms and AC current 1000A rms.
Warning
To test for Apparent power (main display) + Reactive power (secondary display), connect the Meter as follows:
1.
2.
3.
Press the MENU to select Apparent power (main display) + Reactive power (secondary display) range. Press the lever to open the transformer jaw, and clamp them to the corrresponding phase of tested conductor. If user needs to mesaure any phase of the 3 phase, then clamp them to that phaseís conductor. The connecting method of 3 phases 4 wires, 3 phases 3 wires or single phase 2 wires, see figure 6, 7 a nd 8
4. When measuring 3 phase 4 wires: (see figure 17, 18, 19)
Press SELECT to choose the first phase 1, see figure 17.
The double display shows the first phase value of apparent power kVA and reactive power Kvar. Then press SELECT again to choose the second phase 2, see figure 18.
Page 27
Figure 19
26
Model UT232: OPERATING MANUAL
The double display shows the second phase value of apparent power kVA and reactive power Kvar. Press SELECT again to choose the third phase 3, see figure 19.
The double display shows the third phase value of apparent power kVA and reactive power Kvar.
When measuring 3 phase 3 wires: The first phase and secodn phase operating method is same as three phase 4 wires. Jump over the third phase measurement. The maximum measuring range is 600kW when measuring single phase apparent power kVA and reactive power Kvar, OL wil be displayed when it is over than that. Press MAX/ , the display shows MAX, it starts recording the maximum apparent power value. Press again to display the current apparent power value. Press MIN/ , the display shows MIN, it starts recording the minimum apparent power value. Press again to display the current apparent power value.
5.
6.
7.
8.
Note
When testing has been completed, disconnect the connection between the testing leads and the circuit under test and remove testing leads from the input terminals.
Page 28
Figure 20
Figure 21
Model UT232: OPERATING MANUAL
27
E. Power Factor (main display) + Phase Angle (secondary display) Measurement
To avoid damages to the Meter or harms to you, do you measure higher than AC voltage 600V rms and AC current 1000A rms.
Warning
To test for Power factor (main display) + Phase angle (secondary display), connect the Meter as follows:
Press the MENU to select Power factor (main display) + Phase angle (secondary display) range. Press the lever to open the transformer jaw, and clamp them to the corrresponding phase of tested conductor. If user needs to mesaure any phase of the 3 phase, then clamp them to that phaseís conductor. The connecting method of 3 phases 4 wires, 3 phases 3 wires or single phase 2 wires, see figure 6, 7 and 8 When measuring 3 phase 4 wires: (see figure 20, 21, 22)
1.
2.
3.
4.
Press SELECT to choose the first phase 1, see figure 20.
The double display shows the first phase value of power factor PF and phase angle PG. Then press SELECT again to choose the second phase 2, see figure 21.
Page 29
Figure 22
Model UT232: OPERATING MANUAL
28
The double display shows the second phase value of power factor PF and phase angle PG. Press SELECT again to choose the third phase 3, see figure 22.
The double display shows the third phase value of power factor PF and phase angle PG.
5. When measuring 3 phase 3 wires: The first phase and second phase operating
method is same as three phase 4 wires. Jump over the third phase measurement.
6. MAX/ and MIN/ are not valid when measuring
power factor.
When testing has been completed, disconnect the connection between the testing leads and the circuit under test and remove testing leads from the input terminals.
Note
Page 30
29
Model UT232: OPERATING MANUAL
Figure 23
F. Active Energy (main display) + Time (secondary display) Measurement
Warning
To avoid damages to the Meter or harms to you, do you measure higher than AC voltage 600V rms and AC current 1000A rms.
To test for Active Energy (main display) + Time (secondary display), connect the Meter as follows:
1.
2.
3.
4.
Press the MENU to select Power factor (main display) + Phase angle (secondary display) range. Press the lever to open the transformer jaw, and clamp them to the corrresponding phase of tested conductor. If user needs to mesaure any phase of the 3 phase, then clamp them to that phaseís conductor. The connecting method of 3 phase 4 wires, 3 phases 3 wires or single phase 2 wires, see figure 6, 7 and 8 Press SELECT to choose one of the three phases ( 1, 2, 3), see figure 23.
The double display shows the value of tested objectís active engergy kWh value and the measuring time of the corresponding phase. The measuring reading gets increasing along with the time increases. Press HOLD to read a particular time kWh value. Then the reading and time are locked, but still continuous accumulate measuring time. After read the data, press HOLD again to continous measurement. kWh value continous accumulate and the measuring time jumps to the present measuring time. When the measuring time is over 24 hours or the Meter is switched to other measuring ranges, active energy measuring will stop.
Page 31
30
Model UT232: OPERATING MANUAL
The maximum readinng of acitve energy is 9999kWh. OL will be displayed when the reading is over than that.
5. MAX/ and MIN/ are not valid when measuring active energy.
6. Press CLEAR to reset the time.
Note
When there is no input signal, it cannot carry out active energy measurement. When there is input signal, the maximum waiting time is around 10s before timing. When testing has been completed, disconnect the connection between the testing leads and the circuit under test and remove testing leads from the input terminals.
Page 32
Model UT232: OPERATING MANUAL
31
True RMS Measurement and A verage Value Measurement
The True RMS measurement method can measure accurately the effective value of non-sine wave input signal.
Average value measurement method can measure the mean value of one sine wave input signal, and then displays it as RMS value
When the input waveform has distortion, measuring tolerance will be included. The total tolerance depends on the total distortion. Below table 1 shows the waveform coefficient and the relationship and the requested changing factor of sine wave, square wave, pulse rectangle wave, sawtooth triangle wave, RMS value and average value.
Input Wave PK-PK 0-PK RMS AVG
Sine
PK
0
PK-PK
sine commute (whole wave)
PK
0
PK-PK
sine commute (half wave)
PK
0
PK-PK
square wave
PK 0
PK-PK
commuted square wave
PK 0
PK-PK
pulse rectangle
X
0
PK-PK
Y
D=X/Y
sawtooth triangle
PK 0
PK-PK
2.828
1.414
2.828
1.800
1.800
0.9/D
3.600
1.414
1.414
2.828
0.900
1.800
0.9/ D
1.800
1.000
1.000
1.414
0.900
1.272
0.9D/2
1.038
0.900
0.900
0.900
0.900
0.900
0.9/D
0.900
Page 33
Model UT232: OPERATING MANUAL
32
Specifications
A. General Specifications
Maximum Voltage between any Terminals and grounding: Refer to different range input protection voltage. Display: Multi LCD displays, Maximum display 9999. Ranges: Auto Overloading: Display OL. Battery Deficiency: Display . Data Holding: Display Data Logging: Maximum 99, Single or Continuous records Data Recall Maximum and Minimum value display: Voltage, Current, Active Power and Apparent Power ranges Display Backlight: White colour Computer connection: USB Calibration Feature Sleep Mode: To preserve battery life, the Meter automatically turns off if you do not turn press any button for around 15 minutes., except at active factor range.
Sampling: 3 times per second. Max. Jaw Size: 55mm diameter. Analogue Bar Graph Power: 4 x 1.5V battery (LR6) Dimensions: 303mm x 112mm x 39mm Weight: Approximate 601g
Page 34
33
Model UT232: OPERATING MANUAL
B. Environmental Requirements
The Meter is suitable for indoor use. Altitude: Operating: 2000m Storage: 10000m Temperature and humidity:
Operating:
0
~ 30 ( 85%R.H)
30
~ 40 ( 75%R.H)
40
~ 50 ( 45%R.H)
Storage:
-10
~ +60 ( 85%R.H) Safety/ Compliances: IEC 61010 CAT.III 600V, CAT.IV 300V overvoltage and double insulation standard, pollution degree 2. Certification:
Page 35
34
Model UT232: OPERATING MANUAL
Accurate Specifications
Accuracy: (a% reading + b digits), guarantee for 1 year. Operating temperature: 23
5
Operating humidity: 45~75%R.H
A. AC Voltage (True RMS)
Range 15V 100V 300V 600V
Resolution
0.1V
Accuracy
(1.2%+5)
Allowable Maximum overload protection voltage
600 RMS
Input Impedance
10M
B. Frequency
Range 20Hz~500Hz
Resolution 1Hz
Accuracy
(0.5%+5)
Page 36
Model UT232: OPERATING MANUAL
35
D. Active Power ( W=V x A x COS )
Current / Voltage
Current Range
40A 100A 400A 1000A
15V
0.60kW
1.50kW
6.00kW
15.00kW
100V
4.00kW
10.00kW
40.00kW
100.0kW
300V
12.00kW
30.00kW
120.0kW
300.0kW
600V
24.00kW
60.00kW
240.0kW
600.0kW
Voltages Range
Accuracy Resolution
(3%+5)
<1000kW: 0.01kW
100kW: 0.1kW
Remarks:
Allowable maximum overload protection voltage: 600V RMS Allowable maximum overload protection current: 1000A RMS
C. AC Current (True RMS)
Range 40A 100A 400A 1000A
Resolution
0.1A
1A
Accuracy
(2%+5)
Allowable Maximum overload protection current
1000A RMS
Page 37
Model UT232: OPERATING MANUAL
36
E. Apparent Power (VA = V x A)
Current / Voltage
Current Range
40A 100A 400A 1000A
15V
0.60kVA
1.50kVA
6.00kVA
15.00kVA
100V
4.00kVA
10.00kVA
40.00kVA
100.0kVA
300V
12.00kVA
30.00kVA
120.0kVA
300.0kVA
600V
24.00kVA
60.00kVA
240.0kVA
600.0kVA
Voltages Range
Accuracy Resolution
(3%+5)
<1000kVA: 0.01kVA
100kVA: 0.1kVA
Remarks:
Allowable maximum overload protection voltage: 600V RMS Allowable maximum overload protection current: 1000A RMS
Page 38
37
Model UT232: OPERATING MANUAL
F. Reactive Power (Var = V x A x SIN )
Current / Voltage
Current Range
40A 100A 400A 1000A
15V
0.60kVar
1.50kVar
6.00kVar
15.00kVar
100V
4.00kVar
10.00kVar
40.00kVar
100.0kVar
300V
12.00kVar
30.00kVar
120.0kVar
300.0kVar
600V
24.00kVar
60.00kVar
240.0kVar
600.0kVar
Voltages Range
Accuracy Resolution
15V/1000A Range: (4%+10) Other Ranges: (4%+5) <1000kVar: 0.01kVar
100kVar: 0.1kVar
Remarks:
Allowable maximum overload protection voltage: 600V RMS Allowable maximum overload protection current: 1000A RMS
Page 39
38
Model UT232: OPERATING MANUAL
G. Power Factor (PF = W / VA)
Range
0.3~1 (capacitive or inductive)
0.3~1 (capacitive or inductive)
Accuracy
0.022
Resolution
0.001
Measuring Condition The minimum measuring current 10A The minimum measuring voltage 45V Measuring current less than 10A OR Measuring voltage less than 45V
For reference only
H. Phase Angle (PG=acos (PF))
Range 0∞ ~360∞
0∞ ~360∞
Accuracy
1∞
Resolution 1∞
Measuring Condition The minimum measuring current 10A The minimum measuring voltage 45V Measuring current less than 10A OR Measuring voltage less than 45V
For reference only
Remarks:
Allowable maximum overload protection voltage: 600V RMS Allowable maximum overload protection current: 1000A RMS
Page 40
Model UT232: OPERATING MANUAL
39
I. Active Energy (kWh)
Range 1~9999kWh
Accuracy
(3%+2)
Resolution
0.001kWh
Remarks:
Allowable maximum overload protection voltage:
600V RMS
Allowable maximum overload protection current:
1000A RMS
MAINTENANCE
This section provides basic maintenance information including battery replacement instruction.
Do not attempt to repair or service your Meter unless you are qualified to do so and have the relevant calibration, performance test, and service information.
To avoid electrical shock or damage to the Meter, do not get water inside the case.
Warning
A. General Service
Periodically wipe the case with a damp cloth and mild detergent. Do not use abrasives or solvents. To clean the terminals with cotton bar with detergent, as dirt or moisture in the terminals can affect readings. Turn the Meter power off when it is not in use. Take out the battery when it is not using for a long time. Do not use or store the Meter in a place of humidity,
Page 41
Figure 24
Model UT232: OPERATING MANUAL
40
high temperature, explosive, inflammable and strong magnetic field.
B. Replacing the Battery (see figure 24)
To avoid false readings, which could lead to possible electric shock or personal injury, replace the battery as soon as the battery indicator ì î appears.
Make sure the transformer jaw and the tests leads are disconected from the circuit being tested before opening the case bottom.
Warning
To replace the battery:.
1.
2.
3.
4.
5.
Press POWER to turn the Meter off and remove all the connections from the input terminals Turn the Meterís front case down. Remove the screw from the battery door, and separate the battery door from the case bottom. Take out the old battery and replace with 4 x 1.5V battery (LR6). Rejoin the case bottom and the battery compartment, and reinstall the screw.
Page 42
Model UT232: OPERATING MANUAL
41
This operating manual is subject to change without notice.
*END*
Page 43
Model UT232: OPERATING MANUAL
42
Copyright 2007 Uni-Trend Group Limited.
All rights reserved. Manufacturer:
Uni-Trend Technology (Dongguan) Limited Dong Fang Da Dao Bei Shan Dong Fang Industrial Development District Hu Men Town, Dongguan City Guang Dong Province China Postal Code: 523 925
Headquarters: Uni-Trend Group Limited Rm901, 9/F, Nanyang Plaza 57 Hung To Road Kwun Tong Kowloon, Hong Kong Tel: (852) 2950 9168 Fax: (852) 2950 9303 Email: info@uni-trend.com http://www.uni-trend.com
Loading...