UNI-T UT209 Operating Manual

Model UT209
OPERATING MANUAL
Table of Contents Title Page
Overview Unpacking Inspection Safety Information Rules For Safe Operation International Electrical Symbols The Meter Structure Functional Buttons The Effectiveness of Functional Buttons Display Symbols Measurement Operation A. DC/AC Voltage Measurement B. Measuring Resistance C. Testing Diodes D. Testing for Continuity E. Frequency Measurement F. DC Current Measurement
3 4 5 6 9 10 11 13 14 17 17 19 21 23 25 27
Model UT209: OPERATING MANUAL
1
Title Page
30 32 33 33 34 35 35 36 37 38 38 39 40 40 41 41 42
G. AC Current Measurement Sleep Mode Specifications A. General Specifications B. Environmental Requirements Accuracy Specifications A. DC Voltage B. AC Voltage C. Resistance D. Diode Test E. Continuity Test F. Frequency G. DC Current H. AC Current Maintenance A. General Service B. Replacing the Battery
Model UT209: OPERATING MANUAL
2
Overview
This Operating Manual covers information on safety and cautions. Please read the relevant information carefully and observe all the Warnings and Notes strictly.
Warning
To avoid electric shock or personal injury, read the “Safety Information” and “Rules for Safe Operation” carefully before using the Meter.
Digital Clamp Multimeter Model UT209 (hereafter referred to as “the Meter”) are 3 3/4 digits with steady operations, fashionable structure and highly reliable measuring instrument. The Meter uses large scale of integrated circuit with double integrated A/D converter as its core and has full range overload protection.
The Meter can measure AC/DC Voltage, AC/DC Current, Frequency, Resistance, Diodes, Continuity and etc.
Model UT209: OPERATING MANUAL
3
Item Description Qty
1 2 3 4
English Operating Manual Test Lead Tool Box 9V Battery (NEDA1604A or 6LF22)
1 piece 1 pair 1 piece 1 piece
Unpacking Inspection
Open the package case and take out the Meter. Check the following items carefully to see any missing or damaged part:
In the event you find any missing or damage, please contact your dealer immediately .
Model UT209: OPERATING MANUAL
4
Safety Information
This Meter complies with the standards IEC61010: in pollution degree 2, overvoltage category (CAT. II 600V, CAT. III 300V) and double insulation.
CAT. II: Local level, appliance, PORTABLE EQUIPMENT etc., with smaller transient overvoltages than CAT. III. CAT. III: Distribution level, fixed installation, with smaller transient overvoltages than CAT. IV
Use the Meter only as specified in this operating manual, otherwise the protection provided by the Meter may be impaired.
In this manual, a Warning identifies conditions and actions that pose hazards to the user, or may damage the Meter or the equipment under test.
A Note identifies the information that user should pay attention to. International electrical symbols used on the Meter and in this Operating Manual are
explained on page 9.
Model UT209: OPERATING MANUAL
5
Rules For Safe Operation
To avoid possible electric shock or personal injury, and to avoid possible damage to the Meter or to the equipment under test, adhere to the following rules:
Warning
Before using the Meter inspect the case. Do not use the Meter if it is damaged or the case (or part of the case) is removed. Look for cracks or missing plastic. Pay attention to the insulation around the connectors. Inspect the test leads for damaged insulation or exposed metal. Check the test leads for continuity. Replace damaged test leads with identical model number or electrical specifications before using the Meter. Do not apply more that the rated voltage, as marked on the Meter , between the terminals or between any terminal and grounding. When measurement has been completed, disconnect the connection between the test leads and the circuit under test, remove the testing leads away from the input terminals of the Meter and turn the Meter power off. The rotary switch should be placed in the right position and no any
Model UT209: OPERATING MANUAL
6
changeover of range shall be made during measurement is conducted to prevent damage of the Meter. Do not carry out the measurement when the Meter’s back case and battery compartment are not closed to avoid electric shock. Do not input higher than 600V between the two Meter’s input terminal to avoid electric shock and damages to the Meter. When the Meter working at an effective voltage over 70V in DC or 33V rms in AC, special care should be taken for there is danger of electric shock. Use the proper terminals, function, and range for your measurements. Do not use or store the Meter in an environment of high temperature, humidity , explosive, inflammable and strong magnetic field. The performance of the Meter may deteriorate after dampened. When using the test leads, keep your fingers behind the finger guards. To avoid electric shock, do not touch the bare wires, connectors, unused input terminals or the circuit under testing during measurement. Disconnect circuit power and discharge all high-voltage capacitors before testing resistance, continuity and diode. Replace the battery as soon as the battery indicator appears. With a low battery , the Meter might produce false readings that can lead to electric shock and personal injury.
Model UT209: OPERATING MANUAL
7
When servicing the Meter, use only the same model number or identical electrical specifications replacement parts. The internal circuit of the Meter shall not be altered at will to avoid damage of the Meter and any accident. Soft cloth and mild detergent should be used to clean the surface of the Meter when servicing. No abrasive and solvent should be used to prevent the surface of the Meter from corrosion, damage and accident. The Meter is suitable for indoor use. Turn the Meter off when it is not in use and take out the battery when not using for a long time. Constantly check the battery as it may leak when it has been using for some time, replace the battery as soon as leaking appears. A leaking battery will damage the Meter.
Model UT209: OPERATING MANUAL
8
International Electrical Symbols
AC (Alternating Current) DC (Direct Current) AC or DC Grounding Double Insulated Warning. Refer to the Operating Manual Deficiency of Built-In Battery Continuity Test Diode Danger of High Voltage Conforms to Standards of European Union
Model UT209: OPERATING MANUAL
9
Figure 1
The Meter Structure (see figure 1)
Hand Guards: to protect user’s hand from touching the dangerous area. Trigger: press the lever to open the transformer jaws. When the pressure on the lever is released, the jaws will close. Functional Buttons Input Terminals LCD Display Rotary Switch Transformer Jaw: designed to pick up the AC and DC current flowing through the conductor. It could transfer current to voltage. The tested conductor must vertically go through the Jaw center.
1.
2.
3.
4.
5.
6.
7.
Model UT209: OPERATING MANUAL
10
Press SELECT button to select the alternate functions including V
, and
Button Operation Performed SELECT
PMAX/PMIN
Press HOLD to enter the Hold mode in any mode, the Meter beeps. Press HOLD again to exit the Hold mode to return to measurement mode, the Meter beeps.
HOLD
Functional Buttons
Below table indicated for information about the functional button operations.
Press and hold for 2 seconds to enter that function internal calibration. Press the button once to start recording of maximum peak value. Press the button again to start recording of minimum peak value. Press and hold for one second to exit PMAX/PMIN mode.
Press once to turn the display backlight on. It will automatically off after around 15 seconds.
Model UT209: OPERATING MANUAL
11
Button Operation Performed
HOLD
Hz
ZERO
Press ZERO to display the present value as stored value and display zero. After that, all the measurement result displayed will automatically subtract the stored value. Press ZERO again to display the stored value. Press and hold ZERO to exit and back to normal operation.
Turn the rotary switch or press SELECT button can also exit Hold mode. Press HOLD button for 2 seconds when turning on the Meter to display full icon.
When the Meter is at V , A and A
, press the button to measure frequency. But the frequency readings obtained from these ranges are only for reference,
Model UT209: OPERATING MANUAL
12
SELECT MAX/MIN
HOLD
Hz
ZERO
%Hz
44A
1000A
40A
1000A
N/A
N/A
N/A
N/A
N/A N/A
N/A
Rotary Switch Positions
V
Functional Buttons
N/A N/A
The Effectiveness of Functional Buttons
Not every functional buttons can be used on every rotary switch positions. Below table describe which functional buttons can be used on which rotary switch positions
Model UT209: OPERATING MANUAL
13
Loading...