Uniflame Sv3501c Owner's Manual

OWNER’S MANUAL

Outdoor LP Gas Mosquito Exterminator

Model No. SV3501C

Domestic

Registration No. 28452 Pest Control Products Act

WARNING

FOR YOUR SAFETY:

For Outdoor Use Only

(outside any enclosure)

WARNING

FOR YOUR SAFETY:

Keep out of reach of Children

WARNING

FOR YOUR SAFETY:

Read the label and these instructions before using.

WARNING

FOR YOUR SAFETY:

1.Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage.

2.Read the installation, operation, and maintenance instructions thoroughly before installing or servicing this equipment.

3.Failure to follow these instructions could result in fire or explosion, which could cause property damage, personal injury, or death.

Please retain owner’s manual for future reference. If you are assembling this unit for someone else, give this manual to him or her to read and save for future reference.

Made from 70% Bagasse

(Environmentally Friendly Sugar

Cane Pulp By-product)

 

 

 

 

 

 

 

Table of Contents

 

 

 

 

 

Important Safeguards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 2

 

 

Exploded View & Hardware . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . .

3

 

 

 

Assembly Instructions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . .

4

 

 

 

Installing LP Gas Tank . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . .

6

 

 

 

Insert LP Gas Tank. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . .

6

 

 

 

Secure LP Gas Tank. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . .

6

 

 

 

Connect LP Gas Tank. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . .

7

 

 

 

Disconnect LP Gas Tank . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . .

7

 

 

 

Important Mosquito Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . .

7

 

 

 

Important Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . .

7

 

 

 

Important Information about Octenol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . .

7

 

 

 

Important Information About Ultraviolet Light . . . . . . . . . . . . . . . . . . . . . . . . .

. . .

7

 

 

 

Mosquito Facts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . .

7

 

 

 

Controlling Mosquitoes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . .

7

 

 

 

Helpful Links . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . .

7

 

 

 

Operating Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . .

8

 

 

 

Checking for Leaks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . .

8

 

 

 

Placement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . .

8

 

 

 

FineTune®: Customizing the Lure Output . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . .

8

 

 

 

Lighting. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . .

8

 

 

 

Turning Off . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . .

8

 

 

 

Cleaning and Care . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . .

8

 

 

 

Before each use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . .

8

 

 

 

Cleaning Instructions / Routine Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . .

8

 

 

 

Replacing Igniter Battery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . .

8

 

 

 

End of Season Storage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . .

9

 

 

 

Product Registration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . .

9

 

 

 

Limited Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . .

9

 

 

 

Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . .

9

 

 

 

The use and installation of this product must conform to local codes. In absence

 

 

 

 

of local codes, use the National Fuel Gas Code, ANSI Z223.1/NFPA 54, Storage and

 

 

 

 

Handling of Liquefied Petroleum Gases, ANSI/NFPA 58 or CAN/CGA-B149.1, Natural

 

 

 

 

Gas and Propane Installation Code.

 

 

 

 

 

 

 

 

 

Manufactured in China for:

 

 

 

 

Blue Rhino Global Sourcing, Inc.

 

 

 

 

Winston-Salem, NC USA

 

 

 

 

1.888.753.7137, www.bluerhino.com

 

 

 

 

© 2007 Blue Rhino Global Sourcing, Inc. All Rights Reserved

 

 

 

 

SkeeterVac® and FineTune® are registered trademark of Blue Rhino Global Sourcing, Inc.

 

 

 

 

WaveDrawer™ and TacTrap™ are trademarks of Blue Rhino Global Sourcing, Inc. All Rights Reserved.

SV3501C-OM-103 EF

Outdoor LP Gas Mosquito Exterminator Model No. SV3501C

DANGER

If you smell gas -

1.Shut off gas to appliance.

2.Extinguish any open flame.

3.If odor continues, keep away from the appliance immediately and call your gas supplier or your fire department.

WARNING

FOR YOUR SAFETY

1.Do not store or use gasoline or other flammable liquids or vapors in the vicinity of this or any other appliance.

2.An LP cylinder not connected for use shall not be stored in the vicinity of this or any other appliance.

DANGER: Failure to follow the dangers, warning and cautions in this manual may result in serious bodily injury or death, or in a fire or an explosion causing damage to property.

WARNING:

This SkeeterVac® is for outdoor use only, and shall not be used in a building, garage, or any other enclosed area.

Do NOT operate, light or use this appliance within 8 feet of walls, structures, buildings or combustible materials.

It is a violation of Federal law to use this product in a manner inconsistent with its labeling.

This SkeeterVac® is NOT for commercial use.

This SkeeterVac® is for use with liquid propane (LP) gas only. The conversion to or attempted use of natural gas in this LP gas SkeeterVac® is dangerous and will void your warranty.

LP gas Characteristics:

a.LP gas is flammable and hazardous if handled improperly. Become aware of the characteristics before using any LP gas product.

b.LP gas is explosive under pressure, heavier than air, and settles and pools in low areas.

c.LP gas in its natural state has no odor. For your safety, an odorant is added that smells like rotten cabbage.

d.Contact with LP gas can cause freeze burns to skin.

LP gas tank needed to operate. Only tanks marked “propane” may be used.

a.The LP gas supply tank must be constructed and marked in accordance with the Specifications for LP gas Cylinders of the U.S. Department of Transportation (DOT) or the National Standard of Canada, CAN/CSA-B339, Cylinders, Spheres and Tubes for the Transportation of Dangerous Goods; and Commission.

b.LP gas tank must be arranged for vapor withdrawal.

c.The LP gas tank must have a listed overfilling prevention device (OPD).

d.Only use 20-pound cylinders equipped with a cylinder connection device compatible with the connection for outdoor cooking appliances.

e.The LP gas tank must have a tank collar to protect the tank valve.

f.Never use an LP gas tank with a damaged body, valve, collar, or footing.

g.Dented or rusted LP gas tanks may be hazardous and should be checked by your LP gas supplier prior to use.

h.The LP gas tank should not be dropped or handled roughly.

i.Tanks must be stored outdoors out of the reach of children and must not be stored in a building, garage, or any other enclosed area. Your tank must never be stored where temperatures can reach over 125°F.

j.Never keep a filled LP gas tank in a hot car or car trunk. Heat will cause the gas pressure to increase, which may open the relief valve and allow gas to escape.

k.Place dust cap on cylinder valve outlet whenever the cylinder is not in use. Only install the type of dust cap on the cylinder valve outlet that is provided with the cylinder valve. Other types of caps or plugs may result in leakage of propane.

l.Do not store a spare LP gas tank under or near this appliance.

m.Never fill the tank beyond 80 percent full.

n.A fire causing, serious injury or damage to property may occur if the above is not followed exactly.

o.Always transport your tank in a secure, well-ventilated location in your vehicle. LP gas tank should be upright with valve turned off. LP gas tank should be taken directly to and from place of use.

Never attempt to attach this SkeeterVac® to the self-contained LP gas system of a camper trailer, motor home, or house.

The use of alcohol, or prescription or non-prescription drugs may impair the consumer’s ability to properly assemble or safely operate the appliance.

Your SkeeterVac® has been checked at all factory connections for leaks. Recheck all connections, as movement in shipping can loosen connections.

Check for leaks even if your unit was assembled for you by someone else.

Do not operate if gas leak is present. Gas leaks may cause a fire or explosion.

You must follow all leak-checking procedures before operating. To prevent fire or explosion hazard when testing for a leak:

a.Always perform leak test before lighting the SkeeterVac® and each time the tank is connected for use.

b.No smoking. Do not use or permit sources of ignition in the area while conducting a leak test.

c.Conduct the leak test outdoors in a well-ventilated area.

d.Do not use matches, lighters, or a flame to check for leaks.

e.Do not use SkeeterVac® until any and all leaks are corrected.

If you are unable to stop a leak, disconnect the LP gas supply. Call a gas appliance serviceman or your local LP gas supplier.

Do not store or use gasoline or other flammable liquids or vapors within 25 feet (7.62 m) of this appliance.

Do not use in an explosive atmosphere. Keep SkeeterVac® area clear and free from combustible materials, gasoline and other flammable vapors and liquids.

Minimum clearance from sides and back of unit to combustible construction, 21 inches from side and 21 inches from back. Do not use this appliance under overhead combustible surfaces.

It is essential to keep the SkeeterVac®’s valve compartment, burners, and circulating air passages clean. Inspect SkeeterVac® before each use.

Do not alter SkeeterVac® in any manner.

Do not use the SkeeterVac® unless it is COMPLETELY assembled and all parts are securely fastened and tightened.

This SkeeterVac® should be thoroughly cleaned and inspected on a regular basis. Clean and inspect the hose before each use of the

appliance. If there is evidence of abrasion, wear, cuts, or leaks, the hose must be replaced prior to the appliance being put into operation.

Use only the regulator and hose assembly provided. The replacement regulator and hose assembly shall be that specified by the manufacturer.

Use only Blue Rhino Global Sourcing, Inc. factory authorized parts. The use of any part that is not factory authorized can be dangerous. This will also void your warranty.

Do not use this appliance without reading “Operating Instructions” in this manual.

Do not install or use in or on boats or recreational vehicles.

Product performance can vary due to weather, wind and other environmental conditions.

Never lean over the SkeeterVac® when lighting.

Do not attempt to move SkeeterVac® when in use. Allow the SkeeterVac® to cool before moving or storing.

Storage of SkeeterVac® indoors is permissible only if the tank is disconnected, removed from the SkeeterVac® and properly stored outdoors.

Do not attempt to disconnect the gas regulator from the tank or any gas fitting while the SkeeterVac® is in use.

Do not use SkeeterVac® for indoor cooking or heating. TOXIC fumes can accumulate and cause asphyxiation.

After a period of storage and/or nonuse, check for leaks, burner obstructions and inspect for any abrasion, wear, cuts to the hose.

If SkeeterVac® is not in use, the gas must be turned off at the supply tank.

Keep air intake areas clear of dust, dirt and debris

Do not allow children to operate or play near a SkeeterVac® device when it is in use.

Inspect for damage and wear during each maintenance cycle.

It is recommended to use only FineTune® mosquito attractant in your SkeeterVac®. The use of other attractants has not been tested with your product, and void your warranty.

Maximum inlet gas supply pressure is 11 inch water column

Deaths, serious injury or damage to property may occur if the above is not followed exactly.

Contact 1.888.753.7137 for assistance. Do not return to place of purchase.

Parts List

1

Lure Cover

57-07-110

 

 

 

2

FineTune® Lure

CPSX000052

3

TacTrap™

CPSX000069

 

 

 

4

Engine Assembly

55-07-105

 

 

 

5

WaveDrawer®

57-07-118

6

Regulator/Hose

57-07-116

Assembly

 

 

 

 

 

7

Handle

57-07-119

 

 

 

8

Battery Cover

57-07-103

 

 

 

9

LP Gas Tank Cover

57-07-109

 

 

 

10

Post

57-07-128

 

 

 

11

LP Gas Tank (Not Included)

 

 

 

 

12

LP Gas Tank Retainer

57-07-120

Chain

 

 

 

 

 

13

Wheel (2)

57-07-121

 

 

 

14

Hub Cap (2)

57-07-122

 

 

 

15

Base Assembly

57-07-123

Exploded View

1

2

3

5

4

7

6

8

10

9

12

11

13

14

15

13

14

page no.

3

Hardware

A

Bolt

M8x63 Nickel Plated

1 pc

 

 

 

 

 

 

 

B

Bolt

M8x83 Nickel Plated

2 pcs

 

 

 

 

 

 

 

C

Stake

ø8x180 Nickel Plated

2 pcs

 

 

 

 

 

 

 

D

Wing Nut

 

3 pcs

E

Washer

ø8 Stainless Steel

3 pcs

 

 

 

 

 

 

 

F

AA Battery

 

1 pc

Outdoor LP Gas Mosquito Exterminator Model No. SV3501C

Assembly Instructions

1

DO NOT RETURN PRODUCT TO STORE.

2

Attach Post

For assistance call 1.888.753.7137 toll free. Please have

 

your owner’s manual and serial number available for

 

reference.

For Easiest Assembly:

To avoid losing any small components or hardware, assemble your product on a hard level surface that does not have cracks or openings.

Clear an area large enough to layout all components and hardware.

When applicable, tighten all hardware connections by hand first. Once the step is completed go back and fully tighten all hardware.

Follow all steps in order to properly assemble your product.

To complete assembly you will need:

(1) Leak Detection Solution (Instructions on how to make solution are included in “Operating Instructions” section)

(1) precision-filled standard grill LP gas tank (20 lbs. / 9 kgs.) with external valve threads.

Note: You must follow all steps to properly assemble your SkeeterVac®.

Typical assembly: approximately 30 minutes.

A

x 1

D

x 1

 

 

 

3 Attach Handle

4 Insert Battery

B

x 2

D

x 2

E

x 2

 

 

 

 

F

x 1

 

page no.

Contact 1.888.753.7137 for assistance. Do not return to place of purchase.

5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

Attach Engine Assembly

6

Insert FinueTune® Lure and Attach Lure Cover

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7

Insert WaveDrawer™

8

Attach TacTrap™

 

 

 

CAUTION: Do not operate SkeeterVac® with WaveDrawer® cover on the

WaveDrawer®. Cover is only used when emptying or inspecting trap.

Uniflame Sv3501c Owner's Manual

Outdoor LP Gas Mosquito Exterminator Model No. SV3501C

Assembly Instructions (continued)

9

Insert Stakes

Note: Move SkeeterVac® to the final location before inserting stakes into ground.

C x 2

10 Operate WaveDrawer® Cover

CAUTION: Do not operate SkeeterVac® with WaveDrawer® cover on the WaveDrawer®. Cover is only used when emptying or inspecting trap.

Installing LP Gas Tank

To operate you will need (1) precision-filled standard grill LP gas tank (20 lbs.) with external valve threads. Use only Transport Canada approved 9 kg (20 lbs.) cylinders with collar fully intact.

Note: An empty standard grill LP gas tank weighs approximately 18 lbs. A precision-filled standard grill LP gas tank should weigh no more than 38 lbs.

Place LP Gas Tank Cover

Place the LP gas tank cover onto the LP gas tank.

Insert LP Gas Tank

Place precision filled LP gas tank upright into hole in SkeeterVac® body so it is arranged for vapor withdrawal.

Secure LP Gas Tank

Secure tank by wrapping the LP gas tank retainer chain over collar of the LP gas tank.

Place WaveDrawer® Cover

Loading...
+ 14 hidden pages