Intro
Safety
Safety and Warning Disposal and Recycling
Installation
Environmental Requirements Electrical Cutout Dimensions Product Dimensions Water Hookup General Installation Grille / Plinth Installation Door Swing Door Adjust
Service Extended
Wire Diagram Product Liability Warranty Claims Parts Ordering Replacement Parts System Diagnosis Guide Compressor Specifications Troubleshooting Extended Defrost Replace Ice Maker
Door Latch
Operating Instructions
First Use Ice Airflow and Product Loading
Maintenance
Cleaning Cleaning Condenser Extended Non-Use
Service
Troubleshooting Warranty
USER GUIDE
u-line.com
WELCOME TO U-LINE
Congratulations on your U-Line purchase. Your product comes from a company with over five decades of premium modular
ice making, refrigeration, and wine preservation experience. U-Line continues to be the American leader, delivering versatility
and flexibility for multiple applications including residential, light commercial, outdoor and marine use. U-Lines complete
product collection includes Wine Captain
Door Refrigerators, Drawer Models, Freezers, Combo® Models, and more.
U-Line has captivated those with an appreciation for the finer things with exceptional functionality, style, inspired innovations
and attention to even the smallest details. We are known and respected for our unwavering dedication to product design,
quality and selection. U-Line is headquartered in Milwaukee, Wisconsin and has shipped product to five continents for over
two decades and is proud to have the opportunity to ship to you.
PRODUCT INFORMATION
Looking for additional information on your product? User Guides, Spec Sheets, CAD Drawings, Compliance Documentation,
and Product Warranty information are all available for reference and download at u-line.com.
®
Models, Beverage Centers, Clear Ice Machines, Crescent Ice Makers, Glass & Solid
PROPERTY DAMAGE / INJURY CONCERNS
In the unlikely event property damage or personal injury is suspected related to a U-Line product, please take the following
steps:
1. U-Line Customer Care must be contacted immediately at +1.800.779.2547.
2. Service or repairs performed on the unit without prior written approval from U-Line is not permitted. If the unit has been
altered or repaired in the field without prior written approval from U-Line, claims will not be eligible.
GENERAL INQUIRIES
U-Line Corporation
8900 N. 55th Street
Milwaukee, Wisconsin 53223 USA
Monday - Friday 8:00 am to 4:30 pm CST
T: +1.414.354.0300
F: +1.414.354.7905
Email: sales@u-line.com
u-line.com
SERVICE & PARTS ASSISTANCE
Monday - Friday 8:00 am to 4:30 pm CST
T: +1.800.779.2547
F: +1.414.354.5696
Service Email: onlineservice@u-line.com
Parts Email: onlineparts@u-line.com
CONNECT WITH US
Designed, engineered and assembled in WI, USA
Introduction 1
USER GUIDE
NOTICE
SAFETY INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE
u-line.com
Safety and Warning
PLEASE READ all instructions before installing,
operating, or servicing the appliance.
SAFETY ALERT DEFINITIONS
Throughout this guide are safety items labeled with a
Danger, Warning or Caution based on the risk type:
DANGER
!
Danger means that failure to follow this safety
statement will result in severe personal injury or
death.
WARNING
!
Warning means that failure to follow this safety
statement could result in serious personal injury
or death.
that they do not play with this appliance. Cleaning and
user maintenance shall not be performed by children
without supervision.
DANGER
!
Do not use electrical appliances inside the food
storage compartment of this appliance.
WARNING
!
Keep ventilation openings in the appliance
enclosure or in the built in structure clear of
obstruction.
WARNING
!
Do not store explosive substances such as
aerosol cans with flammable propellant in this
appliance.
CAUTION
!
Caution means that failure to follow this safety
statement may result in minor or moderate
personal injury, property or equipment damage.
GENERAL PRECAUTIONS
Use this appliance for its intended purpose only and follow
these general precautions with those listed throughout this
guide.
This appliance is not intended for use by persons
(including children) with reduced physical, sensory or
mental capabilities, or lack of experience or knowledge,
unless they have been given supervision or instruction
concerning use of the appliance by a person responsible
for their safety. Children should be supervised to ensure
WARNING
!
Requirement for an external switch in the fixed
wiring is specified.
WARNING
!
To avoid a hazard due to instability of the
appliance, it must be fixed in accordance with
the instructions.
Safety and Warning 1
USER GUIDE
NOTICE
SAFETY INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE
Staff kitchen areas in shops, office and other working
CAUTION
!
environments.
u-line.com
Use care when moving and handling the unit.
Use gloves to prevent personal injury from sharp
edges.
If your model requires defrosting, DO NOT use
medical devices or other means to accelerate the
defrosting process. DO NOT use an ice pick or
other sharp instrument to help speed up
defrosting. These instruments can puncture the
inner lining or damage the cooling unit. DO NOT
use any type of heater to defrost. Using a heater
to speed up defrosting can cause personal injury
and damage to the inner lining.
Do not lift unit by door handle.
Never install or operate the unit behind closed
doors. Be sure front grille (plinth strip/base
fascia) is free of obstruction. Obstructing free
airflow can cause the unit to malfunction and
will void the warranty.
Farm houses and by clients in hotels, motels and other
residential type environments.
Bed and breakfast type environments.
Catering and similar non-retail applications.
Failure to clean the condenser every six months
can cause the unit to malfunction. This could
void the warranty.
Allow unit temperature to stabilize for 24 hours
before use.
Do not block any internal fans.
Use only genuine U-Line replacement parts.
Imitation parts can damage the unit, affect its
operation or performance and may void the
warranty.
This appliance is intended to be used in household and
similar applications such as:
Safety and Warning 2
USER GUIDE
u-line.com
SAFETY INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE
Disposal and Recycling
DANGER
!
RISK OF CHILD ENTRAPMENT. Before you throw
away your old refrigerator or freezer, take off
the doors and leave shelves in place so children
may not easily climb inside.
If the unit is being removed from service for disposal,
check and obey all federal, state and local regulations
regarding the disposal and recycling of refrigeration
appliances, and follow these steps completely:
1. Remove all consumable contents from the unit.
2. Unplug the electrical cord from its socket.
3. Remove the door(s)/drawer(s).
Disposal and Recycling 1
USER GUIDE
u-line.com
SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE
Environmental Requirements
This model is intended for indoor/interior applications only
and is not to be used in installations that are open/
exposed to natural elements.
This unit is designed to operate between 50°F (10°C) and
100°F (38°C). Higher ambient temperatures may reduce
the unit’s ability to reach low temperatures and/or reduce
ice production on applicable models.
For best performance, keep the unit out of direct sunlight
and away from heat generating equipment.
In climates where high humidity and dew points are
present, condensation may appear on outside surfaces.
This is considered normal. The condensation will
evaporate when the humidity drops.
CAUTION
!
Damages caused by ambient temperatures of
40°F (4°C) or below are not covered by the
warranty.
Environmental Requirements 1
USER GUIDE
NOTICE
u-line.com
SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE
Electrical
Electrical installation must observe all state and
WARNING
!
SHOCK HAZARDElectrical Grounding
Required. Never attempt to repair or perform
maintenance on the unit until the electricity has
been disconnected.
Never remove the round grounding prong from
the plug and never use a two-prong grounding
adapter.
Altering, cutting or removing power cord,
removing power plug, or direct wiring can cause
serious injury, fire, loss of property and/or life,
and will void the warranty.
local codes. This unit requires connection to a
grounded (three-prong), polarized receptacle
that has been placed by a qualified electrician.
The unit requires a grounded and polarized 230 VAC,
50 Hz, 8A power supply (normal household current). An
individual, properly grounded branch circuit or circuit
breaker is recommended. A GFCI (ground fault circuit
interrupter) is usually not required for fixed location
appliances and is not recommended for your unit because
it could be prone to nuisance tripping. However, be sure
to consult your local codes.
See CUTOUT DIMENSIONS for recommended receptacle
location.
Never use an extension cord to connect power to
the unit.
Always keep your working area dry.
If the detachable type electric supply cord is damaged, it
must be replaced by an equivalent cord available from the
manufacturer or its service agent.
Electrical 1
USER GUIDE
NOTICE
Typical
Counter
Height
34-1/4"
(870 mm)
to
35-1/8"
(892 mm)
Cutout Height
25-1/16"
(637 mm)
Filler Panel (Not Provided by U-Line) –
May Be Added Above or Below Unit
to Enclose for a Built-In Look
14-1/4"
(362 mm)
18-1/2" (470 mm) Minimum
4"
(102 mm)
7"
(178 mm)
5/8" (16 mm)
Preferred location for water line and eletrical outlet is in adjacent cabinet.
u-line.com
SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE
Cutout Dimensions
PREPARE SITE
Your U-Line product has been designed for either free-
standing or built-in installation. When built-in, your unit
does not require additional air space for top, sides, or
rear. However, the front grille must NOT be obstructed,
and clearance is required for an electrical and water
connection in the rear.
CAUTION
!
Units can NOT be installed behind a closed
cabinet door.
CUTOUT DIMENSIONS
It is extremely important that this unit sits on a
level surface, as it does not have feet levelers. If
it is not level, the ice mold will not fill evenly.
Cutout Dimensions 1
USER GUIDE
17" (432 mm) *
9" (229 mm)
*Add 1-1/2" For Water Line Clearance
25-1/16"
(637 mm)
14"
(356 mm)
u-line.com
SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE
Product Dimensions
Product Dimensions 1
USER GUIDE
u-line.com
SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE
Water Hookup
PREPARE PLUMBING
The water valve uses a standard 1/4" (6.35 mm)
compression fitting. U-Line recommends using accessory
water hook up kit – part # WATERHOOKUP. The kit
includes a 10' (3 m) braided flexible water supply line and
a brass hose fitting. When using a 1/4" (6.35 mm) O.D.
soft copper supply line use the brass nut and sleeve
included with the unit.
CAUTION
!
Plumbing installation must observe all state and
local codes. All water and drain connections
MUST BE made by a licensed/qualified plumbing
contractor. Failure to follow recommendations
and instructions may result in damage and/or
harm.
CAUTION
!
Do not use any plastic water supply line. The line
is under pressure at all times. Plastic may crack
or rupture with age and cause damage to your
home.
Do not use tape or joint compound when
attaching a braided flexible water supply line
that includes a rubber gasket. The gasket
provides an adequate seal – other materials
could cause blockage of the valve.
Failure to follow recommendations and
instructions may result in damage and/or harm,
flooding or void the product warranty.
Use new hose set. Do not reuse old hose set.
Water Supply Connection
When connecting the water supply, please note the
following:
Before installing the unit and connecting to the cold
water supply, review the local plumbing codes.
The water pressure should be between 20 and 120 psi
(138 and 827 kPa).
The water line MUST have a shut-off valve in the
supply line.
The water line should be looped into 2 coils. This will
allow the unit to be removed for cleaning and servicing.
Make certain that the tubing is not pinched or damaged
during installation.
CAUTION
!
Turn off water supply and disconnect electrical
supply to unit prior to installation.
Use caution when handling back panel. The
edges could be sharp.
1. Turn off water supply and disconnect electrical supply
to product prior to attempting installation.
2. Remove the grille (plinth strip/base fascia) and access
panel (if equipped) along with back panel.
WARNING
!
Connect to potable water supply only.
Water Hookup 1
USER GUIDE
NOTICE
Remove
ZLWKɠDW
screwdriver
u-line.com
SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE
3. Locate water
valve in the front
of the unit and
thread water
supply line
through.
Route the water
supply line
through the unit so it does not come into contact
with any internal components other than the
solenoid valve. Normal operation creates some
vibration. A water supply line contacting an
internal component or cabinet wall can cause
excessive noise during operation or damage to
the line.
4. On the back panel,
break away filler feature
in bushing with flat
screwdriver.
6. Turn on water supply and check for leaks.
7. Reinstall the grille (plinth strip/base fascia) and access
panel (if equipped) along with the back panel.
8. Install retaining clip.
5. Thread water line
through back panel hole
(with bushing).
Water Hookup 2
USER GUIDE
NOTICE
1
u-line.com
SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE
General Installation
LEVELING INFORMATION
Because these units do not have leveling legs, it
is extremely important that they sit on a level
surface. If they are not level, the ice mold will
not fill evenly.
Use a level to confirm
the unit is level. Level
should be placed along
top edge and side edge
as shown.
INSTALLATION
1. Plug in the power/electrical cord.
2. Gently push the unit into position. Be careful not to
entangle the cord and water line.
3. Re-check the leveling, from front to back and side to
side. Make any necessary adjustments.
4. Remove the interior packing material and wipe out the
inside of the unit with a clean, water-dampened cloth.
General Installation 1
USER GUIDE
1
2
u-line.com
SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE
Grille - Plinth Installation
REMOVING AND INSTALLING GRILLE
WARNING
!
Disconnect electric power to the unit before
removing the grille.
When using the unit, the grille (plinth strip/base
fascia) must be installed.
WARNING
!
DO NOT touch the condenser fins. The condenser
fins are SHARP and can be easily damaged.
Removing the grille
1. Disconnect power to the unit.
2. Loosen the screw (1) in the center.
3. Remove grille (2) from unit.
Installing the grille
1. Align cabinet and grille holes and secure, but do not
over tighten grille screw (1).
2. Reconnect power to the unit.
Grille - Plinth Installation 1
USER GUIDE
3/4" (19 mm) Min.
Wall
90°
Door Swing
u-line.com
SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE
Door Swing
All units have a zero clearance for the door to open 90°.
U-Line recommends a minimum door clearance of 3/4"
(19 mm) to accommodate the handle if the unit is
installed next to a wall or similar type of structure.
Door Swing 1
Loading...
+ 35 hidden pages