U-Line WH95FC, MarineSS1095 User Manual

USER GUIDE
RIGHT PRODUCT. RIGHT PLACE. RIGHT TEMPERATURE. SINCE 1962.
SAFETY INSTALLATION & INTEGRATION OPERATING INSTRUCTIONS MAINTENANCE SERVICE
Marine Series WH95FC 14" Crescent Ice Maker
SAFETY INSTALLATION & INTEGRATION OPERATING INSTRUCTIONS MAINTENANCE SERVICE
Intro
Safety
Safety and Warning Disposal and Recycling
Installation
Environmental Requirements Electrical Cutout Dimensions Product Dimensions Water Hookup General Installation Grille / Plinth Installation Door Swing Door Adjust
Service Extended
Wire Diagram Product Liability Warranty Claims Ordering Replacement Parts System Diagnosis Guide Compressor Specifications Troubleshooting Extended Defrost Replace Ice Maker
Door Latch
Operating Instructions
First Use Ice Airflow and Product Loading
Maintenance
Cleaning Cleaning Condenser Extended Non-Use
Service
Troubleshooting Warranty
USER GUIDE
u-line.com
WELCOME TO U-LINE
Congratulations on your U-Line purchase. Your product comes from a company with over five decades and three generations
of premium modular ice making, refrigeration, and wine preservation experience. U-Line continues to be the American
leader, delivering versatility and flexibility for multiple applications including residential, light commercial, outdoor and marine
use. U-Line’s complete product collection includes modular Wine Captain
Crescent Ice Makers, Glass & Solid Door Refrigerators, Drawer Models, Freezers, and Combo® Models.
U-Line has captivated those with an appreciation for the finer things with exceptional functionality, style, inspired innovations
and attention to even the smallest details. We are known and respected for our unwavering dedication to product design,
quality and selection. U-Line is headquartered in Milwaukee, Wisconsin with a west coast office located in Laguna Beach,
California and European support in Dublin, Ireland. U-Line has shipped product to five continents for over two decades and is
proud to have the opportunity to ship to you.
PRODUCT INFORMATION
Looking for additional information on your product? User Guides, Quick Reference Guides, CAD Drawings, Compliance
Documentation, and Product Warranty information are all available for reference and download at u-line.com under
Documentation.
®
Models, Beverage Centers, Clear Ice Machines,
PROPERTY DAMAGE / INJURY CONCERNS
In the unlikely event property damage or personal injury is suspected related to a U-Line product, please take the following
steps:
1. U-Line Customer Care must be contacted immediately at +1.800.779.2547.
2. Service or repairs performed on the unit without prior written approval from U-Line is not permitted. If the unit has been
altered or repaired in the field without prior written approval from U-Line, claims will not be eligible.
SERVICE INFORMATION
Answers to Customer Frequently Asked Questions are available at u-line.com under Customer Care or you may contact our
Customer Care group directly, contact information below.
GENERAL INQUIRIES
U-Line Corporation
8900 N. 55th Street
Milwaukee, Wisconsin 53223 USA
Monday - Friday 8:00 am to 4:30 pm CST
T: +1.414.354.0300
F: +1.414.354.7905
Email: sales@u-line.com
u-line.com
SERVICE & PARTS ASSISTANCE
Monday - Friday 8:00 am to 5:30 pm CST
T: +1.800.779.2547
F: +1.414.354.5696
Service Email: onlineservice@u-line.com
Parts Email: onlineparts@u-line.com
CONNECT WITH US
Designed, engineered and assembled in WI, USA
Introduction 1
USER GUIDE
NOTICE
u-line.com
SAFETY INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE
Safety and Warning
Please read all instructions before installing,
operating, or servicing the appliance.
Use this appliance for its intended purpose only and follow
these general precautions with those listed throughout this
guide:
SAFETY ALERT DEFINITIONS
Throughout this guide are safety items labeled with a
Danger, Warning or Caution based on the risk type:
DANGER
!
Danger means that failure to follow this safety
statement will result in severe personal injury or
death.
WARNING
!
Warning means that failure to follow this safety
statement could result in serious personal injury
or death.
CAUTION
!
Caution means that failure to follow this safety
statement may result in minor or moderate
personal injury, property or equipment damage.
Safety and Warning 1
USER GUIDE
u-line.com
SAFETY INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE
Disposal and Recycling
DANGER
!
RISK OF CHILD ENTRAPMENT. Before you throw
away your old refrigerator or freezer, take off
the doors and leave shelves in place so children
may not easily climb inside.
If the unit is being removed from service for disposal,
check and obey all federal, state and local regulations
regarding the disposal and recycling of refrigeration
appliances, and follow these steps completely:
1. Remove all consumable contents from the unit.
2. Unplug the electrical cord from its socket.
3. Remove the door(s)/drawer(s).
Disposal and Recycling 1
USER GUIDE
u-line.com
SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE
Environmental Requirements
This model is intended for indoor/interior applications only
and is not to be used in installations that are open/
exposed to natural elements.
This unit is designed to operate between 50°F (10°C) and
100°F (38°C). Higher ambient temperatures may reduce
the unit’s ability to reach low temperatures and/or reduce
ice production on applicable models.
For best performance, keep the unit out of direct sunlight
and away from heat generating equipment.
In climates where high humidity and dew points are
present, condensation may appear on outside surfaces.
This is considered normal. The condensation will
evaporate when the humidity drops.
CAUTION
!
Damages caused by ambient temperatures of
40°F (4°C) or below are not covered by the
warranty.
Environmental Requirements 1
USER GUIDE
NOTICE
u-line.com
SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE
Electrical
WARNING
!
SHOCK HAZARDElectrical Grounding
Required. Never attempt to repair or perform
maintenance on the unit until the electricity has
been disconnected.
Never remove the round grounding prong from
the plug and never use a two-prong grounding
adapter.
Altering, cutting or removing power cord,
removing power plug, or direct wiring can cause
serious injury, fire, loss of property and/or life,
and will void the warranty.
Never use an extension cord to connect power to
the unit.
Always keep your working area dry.
Electrical installation must observe all state and
local codes. This unit requires connection to a
grounded (three-prong), polarized receptacle
that has been placed by a qualified electrician.
The unit requires a grounded and polarized 115 VAC,
60 Hz, 15A power supply (normal household current). An
individual, properly grounded branch circuit or circuit
breaker is recommended. A GFCI (ground fault circuit
interrupter) is usually not required for fixed location
appliances and is not recommended for your unit because
it could be prone to nuisance tripping. However, be sure
to consult your local codes.
See CUTOUT DIMENSIONS for recommended receptacle
location.
Electrical 1
USER GUIDE
NOTICE
Cutout Height
25-1/8"
(638 mm)
Filler Panel (Not Provided by U-Line) –
Needed to Attach Mounting Flange on Unit
18-1/2" (470 mm) Minimum
Preferred location for water line and eletrical outlet is in adjacent cabinet.
14-1/4"
(362 mm)
Cutout Width
3/4"
(19 mm)
Minimum Flange
Mounting Area
3/4"
(19 mm)
Minimum Flange
Mounting Area
5/8" (16 mm)
4"
(102 mm)
7"
(178 mm)
u-line.com
SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE
Cutout Dimensions
PREPARE SITE
Your U-Line product has been designed for either free-
standing or built-in installation. When built-in, your unit
does not require additional air space for top, sides, or
rear. However, the front grille must NOT be obstructed,
and clearance is required for an electrical and water
connection in the rear.
CAUTION
!
Units can NOT be installed behind a closed
cabinet door.
CUTOUT DIMENSIONS
It is extremely important that this unit sits on a
level surface, as it does not have feet levelers. If
it is not level, the ice mold will not fill evenly.
Cutout Dimensions 1
USER GUIDE
17" (432 mm)*
25-1/16"
(637 mm)
14" (356 mm)
8 15/16"
(227 mm)
*Add 1-1/2" For For Water Line Clearance
u-line.com
SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE
Product Dimensions
Product Dimensions 1
USER GUIDE
u-line.com
SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE
Water Hookup
PREPARE PLUMBING
The water valve uses a standard 1/4" (6.35 mm)
compression fitting. U-Line recommends using accessory
water hook up kit – part # WATERHOOKUP. The kit
includes a 10' (3 m) braided flexible water supply line and
a brass hose fitting. When using a 1/4" (6.35 mm) O.D.
soft copper supply line use the brass nut and sleeve
included with the unit.
CAUTION
!
Plumbing installation must observe all state and
local codes. All water and drain connections
MUST BE made by a licensed/qualified plumbing
contractor. Failure to follow recommendations
and instructions may result in damage and/or
harm.
CAUTION
!
Do not use any plastic water supply line. The line
is under pressure at all times. Plastic may crack
or rupture with age and cause damage to your
home.
Do not use tape or joint compound when
attaching a braided flexible water supply line
that includes a rubber gasket. The gasket
provides an adequate seal – other materials
could cause blockage of the valve.
Failure to follow recommendations and
instructions may result in damage and/or harm,
flooding or void the product warranty.
Use new hose set. Do not reuse old hose set.
Water Supply Connection
When connecting the water supply, please note the
following:
Before installing the unit and connecting to the cold
water supply, review the local plumbing codes.
The water pressure should be between 20 and 120 psi
(138 and 827 kPa).
The water line MUST have a shut-off valve in the
supply line.
The water line should be looped into 2 coils. This will
allow the unit to be removed for cleaning and servicing.
Make certain that the tubing is not pinched or damaged
during installation.
CAUTION
!
Turn off water supply and disconnect electrical
supply to unit prior to installation.
Use caution when handling back panel. The
edges could be sharp.
1. Turn off water supply and disconnect electrical supply
to product prior to attempting installation.
2. Remove the grille (plinth strip/base fascia) and access
panel (if equipped) along with back panel.
WARNING
!
Connect to potable water supply only.
Water Hookup 1
USER GUIDE
NOTICE
Remove
ZLWKɠDW
screwdriver
u-line.com
SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE
3. Locate water
valve in the front
of the unit and
thread water
supply line
through.
Route the water
supply line
through the unit so it does not come into contact
with any internal components other than the
solenoid valve. Normal operation creates some
vibration. A water supply line contacting an
internal component or cabinet wall can cause
excessive noise during operation or damage to
the line.
4. On the back panel,
break away filler feature
in bushing with flat
screwdriver.
6. Turn on water supply and check for leaks.
7. Reinstall the grille (plinth strip/base fascia) and access
panel (if equipped) along with the back panel.
8. Install retaining clip.
5. Thread water line
through back panel hole
(with bushing).
Water Hookup 2
USER GUIDE
NOTICE
1
u-line.com
SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE
General Installation
LEVELING INFORMATION
Because these units do not have leveling legs, it
is extremely important that they sit on a level
surface. If they are not level, the ice mold will
not fill evenly.
Use a level to confirm
the unit is level. Level
should be placed along
top edge and side edge
as shown.
INSTALLATION
1. Plug in the power/electrical cord.
2. Gently push the unit into position. Be careful not to
entangle the cord and water line.
3. Re-check the leveling, from front to back and side to
side. Make any necessary adjustments.
4. Remove the interior packing material and wipe out the
inside of the unit with a clean, water-dampened cloth.
General Installation 1
USER GUIDE
1
2
4
u-line.com
SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE
Grille - Plinth Installation
REMOVING AND INSTALLING GRILLE
WARNING
!
Disconnect electric power to the unit before
removing the grille.
When using the unit, the grille (plinth strip/base
fascia) must be installed.
WARNING
!
DO NOT touch the condenser fins (4). The
condenser fins are SHARP and can be easily
damaged.
Removing the grille
1. Disconnect power to the unit.
2. Loosen the screw (1).
3. Remove grille (2) from unit.
Installing the grille
1. Align cabinet and grille holes and secure, but do not
over tighten grille screw (1).
2. Reconnect power to the unit.
Grille - Plinth Installation 1
USER GUIDE
3/4" (19 mm) Min.
Wall
90°
Door Swing
u-line.com
SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE
Door Swing
All units have a zero clearance for the door to open 90°.
U-Line recommends a minimum door clearance of 3/4"
(19 mm) to accommodate the handle if the unit is
installed next to a wall or similar type of structure.
Door Swing 1
USER GUIDE
NOTICE
Hinge screws
u-line.com
SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE
Door Adjustments
CHECKING DOOR ALIGNMENT
The units door is aligned at the factory before shipment.
However, its alignment could have been disturbed during
shipment.
Properly aligned, the door’s gasket should be
firmly in contact with the cabinet all the way
around the door (no gaps).
1. Carefully examine the door’s gasket to ensure that it is
firmly in contact with the cabinet.
2. When inspecting door alignment, make sure the door
gasket is not pinched on the hinge side of the door.
To reverse the door mounting, perform the following:
1. Remove grille (see GRILLE-PLINTH INSTALLATION).
2. Remove top hinge from cabinet (three screws). Hold
door to keep it from falling.
3. Lift the door off the bottom hinge.
ALIGNMENT AND ADJUSTMENT
1. Loosen (do not remove) top and bottom hinge screws.
2. Align door squarely with cabinet. Make sure gasket is
firmly in contact with cabinet all the way around the
door (no gaps).
3. Tighten bottom hinge screws.
4. Tighten top hinge screws.
REVERSING THE DOOR
Location of the unit may make it desirable to mount the
door on the opposite side of the cabinet.
The hinge hardware will be removed and reinstalled on the
opposite side of the cabinet.
4. Remove bottom hinge from cabinet (two screws).
5. Remove screws on opposite side of cabinet.
Door Adjustments 1
Loading...
+ 34 hidden pages