U-Line H-6521 User Manual

π H-6521
HYDRONIC PORTABLE BASEBOARD HEATER
H- 6521 120 V 150 0 12.5 5120
1-800-295 -5510
uline.com
SPECIFICATIONS
WARNING
When using electrical appliances, basic precautions should always be followed to reduce the risk of fire, electric shock and injury to persons, including the following:
• Read all instructions before using the heater.
• Use this heater only as described in the following instructions. Any other use not recommended by the manufacturer may cause fire, electric shock or injury to persons.
• Always plug heaters directly into a wall outlet or receptacle.
• Never use with an extension cord or power strip.
• Do not operate any heater with a damaged cord or plug, after the heater malfunctions or has been dropped or damaged in any manner. Discard heater or contact Uline Customer Service at 1-800-295-5510.
• Do not run cord under carpeting. Do not cover cord with throw rugs, runners or similar coverings. Do not route cord under furniture or appliances. Arrange cord away from traffic areas and where it will not be tripped over.
• Always unplug heater when not in use.
• To disconnect, rotate thermostat to the LO set point or flip ON-OFF switch to off. Then, grip plug (not cord) and pull from outlet.
• A heater has hot and arcing or sparking parts inside. Do not use in areas where gasoline or flammable liquids are used or stored.
• This heater is hot when in use. To avoid burns, do not let bare skin touch hot surfaces. Keep combustible materials away from heater.
• To prevent a possible fire, do not block air intakes or exhaust in any manner. Do not use on soft surfaces, like a bed, where openings may become blocked.
• Do not insert or allow foreign objects to enter any ventilation or exhaust opening, as this may cause an electric shock or fire, or damage the heater.
• This heater is not intended for use in wet locations.
• Do not operate heater without support legs installed. See Assembly on page 2.
PAGE 1 OF 3 0217 IH-6521
ASSEMBLY
1. After removing the heater from its carton, carefully inspect it for possible shipping damage. Return damaged units to Uline Customer Service.
2. Remove one plastic support leg and thermostat knob from packaging in bottom of heater. The right hand support leg is pre-assembled to the power cord and requires only to be snapped into place. (See Figure 1)
3. Fit left hand support leg onto heater and snap into position. (See Figure 1)
4. Position thermostat knob onto thermostat shaft. (See Figure 1)
NOTE: The knob will only fit onto shaft in one way.
OPERATION
IMPORTANT! This heater is a major electrical appliance and requires adequate electrical
power. The outlet in use must be a 120 volt circuit protected by a 15 or 20 amp fuse or circuit breaker. No other major electrical appliance should be operated in the same circuit as the heater.
Use care when choosing the location and using the heater. Do not block the heater in any way to prevent air to flow freely through the heater. Keeping the heater clean will also
improve the efficiency and prevent overheating. See Maintenance on page 3 for cleaning information.
WARNING! The heater plug must fit tightly into outlet. A loose fitting or worn outlet may cause
plug connection to heat, damage plug or outlet and cause a fire. If outlet is loose or worn, discontinue using heater until the outlet can be
replaced.
CAUTION! High Temperature. Keep electrical cords, drapes and furnishings away from
heater. Do not allow curtains or other furnishing to contact heater. Maintain at least 6" clearance around the heater at all times.
To reduce the risk of fire, do not store or use gasoline or other flammable substances near
heater.
Figure 1
Thermostat
Knob
Support Legs
Do not operate heater without support legs attached as shown in Figure 1.
Do not allow heater to operate in any position except shown in operating instructions.
Do not use heater near water or in humid environment.
Heater is to be used on the floor only. Do not use on a shelf, table or any location except the floor.
NOTE: Heater is provided with a pilot light ON/OFF switch and a temperature control thermostat.
NOTE: Heater has automatic-resetting thermal safety switch that will disconnect power to the heating element should the heater be placed into an abnormal condition (such as a blockage) to prevent a fire. When the heater cools, the safety switch will reset allowing the heater to return to normal operation.
1. Plug heater power supply cord into 120 volt outlet.
2. Push ON/OFF switch to ON position.
NOTE: ON/OFF switch will illuminate when in the ON position.
3. Rotate thermostat knob in a clockwise direction until it stops.
PAGE 2 OF 3 0217 IH-6521
Loading...
+ 1 hidden pages