GENERAL INFORMATION
RECOMMENDED HUMIDITY LEVELS
• Spring/Summer: 35% - 50%
• Fall/Winter: 35% - 40%
During operation your dehumidifier will exhaust warm air
from the side of the unit. This is normal operation.
EMPTYING THE BUCKET
The more moisture your dehumidifier removes from the air, the more often you may have to empty the
bucket (unless you are using the continuous drainage option). The number of times the bucket will be emptied depends on the dehumidifier model.
The chart below shows how many pints removed and
how many times to empty bucket in a 24-hour period.
MODEL NO. PINTS REMOVED BUCKETS EMPTIED
H-6369 45 PINTS 6 TIMES H-6370 70 PINTS 5 TIMES
LESS MOISTURE BEING REMOVED OVER TIME IS NORMAL
Using a dehumidifier will cause your area to maintain a more comfortable humidity level. Over time, this
humidity level will become more and more stable. Due to the stable humidity level in the area, the dehumidifier will need to remove less and less moisture over time.
Please do not be concerned if the dehumidifier is removing less moisture from the air or the bucket
is taking longer to fill. This is a direct result of your dehumidifier creating a more stable humidity level in your area.
WATER IN THE BUCKET
There might be a small amount of water present in the bucket before using the dehumidifier for the first time, which is normal. This is caused by the preliminary testing done by the factory.
IMPORTANT!
• Always place the unit on a level surface.
• Never use or store gasoline or other flammable vapor or liquid near this unit unless instructed by this manual.
• Maintain at least 12-18 inches clearance space around unit. Do not block or cover air inlet or outlet grills.
• The unit must be connected to a correctly grounded power supply.
• Do not start or stop the unit by inserting or pulling out the power plug.
• Do not use an adapter plug or extension cord.
• Do not use the unit in the immediate surroundings of a bath, a shower or a swimming pool.
• Do not insert anything into the air outlet. Do not obstruct air inlet or outlet grills unless instructed by this manual.
• Do not let children play near this unit.
• Always inspect the cord for signs of damage before use. If the power cord is damaged, it must be replaced by the manufacturer or a qualified service technician.
• When cleaning the unit, always turn off the unit and unplug the power cord.
PAGE 1 OF 7 0217 IH-6369
SPECIFICATIONS
• Noise level is measured at a distance of 3.28 feet away from the front of the unit.
MODEL NO. H-6369 H-6370
Dehumidifying Capacity 45 Pints per day 70 Pints per day Power Consumption (Watts) 460 Watts 730 Watts Air Flow Volume (High/Med/Low) 135/125/105 CFM 205/190/165 CFM Power Source 115 V/60 Hz 115 V/60 Hz Rated Current (Amps) 4 A 6.3 A Sound Pressure Level (High/Med/Low) 53/51/49 dB(A) 53/51/49 dB(A) Weight 34.2 lbs 47. 4 l bs Dimensions (W x D x H) 13.375" W x 10" D x 19.5" H 15.25" W x 11.25" D x 24.875" H Energy Star Bucket Capacity 8.5 Pints 16.9 Pint s
These specifications are for reference only. For actual data, please refer to the rating label on the back of the unit.
®
Yes Yes
CASTER INSTALLATION
1. Remove casters from the bucket.
2. For H-6369, please check if the casters are under the lid of the bucket. If so, please remove lid to access casters, then replace the lid before operation.
For H-6370, the four casters can be taken out from the side of the bucket directly.
• Power consumption is measured when the fan runs at the highest speed setting.
NOTE: Verify the plastic float on the top of the bucket is still securely installed and swinging properly before placing bucket back in the dehumidifier.
3. Tilt the dehumidifier no more than 45° and forcibly insert the casters. Make sure the ring around the caster is flush against the bottom of the dehumidifier.
CONTROL PANEL
Digital
Power ON
LED Indicator
POWER CLEAN FILTER HIGH
POWER
PAGE 2 OF 7 0217 IH-6369
Clean Filter
LED Indicator
FILTER TIMER
Fan Speed
LED Indicators
MEDIUM
LOW
FAN SPEED MODE
Increase/Decrease Room
Humidistat
Display
HUMIDITY %
Humidity Level
MyHome Mode
LED Indicators
SLEEPING SPACE
LIVING SPACE
BASEMENT
CONTINUOUS
Child-Lock
LED Indicator
LED Indicator
LOCK BUCKET FULL
TIMER
Timer
Bucket Full
LED Indicator
OPERATION
1. When first operating the dehumidifier, run it in continuous mode for 24 hours.
2. Power On and Off – Press the POWER button once to manually turn the unit on. Press the POWER button once more to turn the unit off.
3. Humidity Selection – Press the or buttons to choose the desired relative humidity in the room. Each press of the button will change the desired room humidity by 5%. The room humidity is selectable from 35%-80% or continuous. The unit will cycle on and off to maintain the humidity level chosen on the digital display. If you want the dehumidifier to operate continuously regardless of the room humidity, press the MODE button until you see "CO" on the digital display. This will enable continuous operation and the "Continuous" indicator will light up on the control panel.
4. Fan Speed Control – Press the FAN SPEED button to cycle through the different fan speeds: high, medium and low. The fan speed can be visually distinguished by the fan speed indicators on the control panel.
5.
Timer Auto On – To program the unit to automatically turn on, press the TIMER button when the unit is off. Press or to increase or decrease the timer in 30 minute increments (.5 hours) up to 10 hours. After 10 hours, each press of the button will increase the timer in 1 hour increments up to 24 hours. Once the desired time is reached, the unit will automatically turn on.
Timer Auto Shut-Off – To program the unit to automatically turn off, press the TIMER button when the unit is on. Each press of the or buttons will change the timer setting in 30 minute increments (.5 hours) up to 10 hours. After 10 hours, each press of the or buttons will increase or decrease the timer in 1 hour increments up to 24 hours. Once the desired time is over, the unit will automatically power off.
NOTE: Fan will continue to run even when the compressor is off. This is normal and allows the unit to circulate air and operate more efficiently
6. Bucket Full – When the water bucket is full of water, the unit will automatically shut off, make a beeping noise and the Bucket Full Indicator will light up. The dehumidifier will not function until the water bucket is emptied and placed back inside the unit. The bucket should be cleaned every few weeks to prevent the growth of mold, mildew and bacteria. Use a mild detergent to clean the bucket. Once clean, completely dry the bucket and place it back inside the dehumidifier. (See Figure 1)
Figure 1
NOTE: When the bucket is full or removed from the machine, the compressor will turn off, but the fan will continue to run for a few minutes. This is completely normal. The dehumidifier will not be removing moisture from the air at this time.
NOTE: When removing moisture from the air, the dehumidifier will exhaust warm air from the side exhaust vent.
NOTE: Do not place a full bucket on the floor, because the bottom is uneven.
7. Clean Filter – When the filter needs to be cleaned, the filter indicator will light up (after 250 hours of use). Remove the filter from the back of the unit by using your thumbs to press down on the filter tabs directly above the filter. (See Figure 2) Clean the filter with warm, soapy water. Dry thoroughly before replacing the filter. Once the filter is completely dry, place the filter back in the unit and press the FILTER button to reset the filter indicator.
Figure 2
CAUTION! Do not operate the dehumidifier without the included filter.
PAGE 3 OF 7 0217 IH-6369