π H-6369, H-6370
DEHUMIDIFIER
1-800 -295 - 5510
uline.com
GENERAL INFORMATION
RECOMMENDED HUMIDITY LEVELS
• Spring/Summer: 35% - 50%
• Fall/Winter: 35% - 40%
WARM AIR EXHAUST IS NORMAL
During operation your dehumidifier will exhaust warm air
from the side of the unit. This is normal operation.
EMPTYING THE BUCKET
The more moisture your dehumidifier removes from
the air, the more often you may have to empty the
bucket (unless you are using the continuous drainage
option). The number of times the bucket will be emptied
depends on the dehumidifier model.
The chart below shows how many pints removed and
how many times to empty bucket in a 24-hour period.
MODEL NO. PINTS REMOVED BUCKETS EMPTIED
H-6369 45 PINTS 6 TIMES
H-6370 70 PINTS 5 TIMES
LESS MOISTURE BEING REMOVED OVER TIME IS
NORMAL
Using a dehumidifier will cause your area to maintain
a more comfortable humidity level. Over time, this
humidity level will become more and more stable. Due
to the stable humidity level in the area, the dehumidifier
will need to remove less and less moisture over time.
Please do not be concerned if the dehumidifier is
removing less moisture from the air or the bucket
is taking longer to fill. This is a direct result of your
dehumidifier creating a more stable humidity level in
your area.
WATER IN THE BUCKET
There might be a small amount of water present in the
bucket before using the dehumidifier for the first time,
which is normal. This is caused by the preliminary testing
done by the factory.
IMPORTANT!
• Always place the unit on a level surface.
• Never use or store gasoline or other flammable
vapor or liquid near this unit unless instructed
by this manual.
• Maintain at least 12-18 inches clearance
space around unit. Do not block or cover air
inlet or outlet grills.
• The unit must be connected to a correctly
grounded power supply.
• Do not start or stop the unit by inserting or
pulling out the power plug.
• Do not use an adapter plug or extension cord.
• Do not use the unit in the immediate
surroundings of a bath, a shower or a
swimming pool.
• Do not insert anything into the air outlet. Do not
obstruct air inlet or outlet grills unless instructed
by this manual.
• Do not let children play near this unit.
• Always inspect the cord for signs of damage
before use. If the power cord is damaged, it
must be replaced by the manufacturer or a
qualified service technician.
• When cleaning the unit, always turn off the unit
and unplug the power cord.
PAGE 1 OF 7 0217 IH-6369

SPECIFICATIONS
• Noise level is measured at a distance of 3.28 feet
away from the front of the unit.
MODEL NO. H-6369 H-6370
Dehumidifying Capacity 45 Pints per day 70 Pints per day
Power Consumption (Watts) 460 Watts 730 Watts
Air Flow Volume (High/Med/Low) 135/125/105 CFM 205/190/165 CFM
Power Source 115 V/60 Hz 115 V/60 Hz
Rated Current (Amps) 4 A 6.3 A
Sound Pressure Level (High/Med/Low) 53/51/49 dB(A) 53/51/49 dB(A)
Weight 34.2 lbs 47. 4 l bs
Dimensions (W x D x H) 13.375" W x 10" D x 19.5" H 15.25" W x 11.25" D x 24.875" H
Energy Star
Bucket Capacity 8.5 Pints 16.9 Pint s
These specifications are for reference only. For actual data, please refer to the rating label on the back of the unit.
®
Yes Yes
CASTER INSTALLATION
1. Remove casters from the bucket.
2. For H-6369, please check if the casters are under
the lid of the bucket. If so, please remove lid
to access casters, then replace the lid before
operation.
For H-6370, the four casters can be taken out from
the side of the bucket directly.
• Power consumption is measured when the fan runs
at the highest speed setting.
NOTE: Verify the plastic float on the top of the
bucket is still securely installed and swinging
properly before placing bucket back in the
dehumidifier.
3. Tilt the dehumidifier no more than 45° and forcibly
insert the casters. Make sure the ring around the
caster is flush against the bottom of the dehumidifier.
CONTROL PANEL
Digital
Power ON
LED Indicator
POWER CLEAN FILTER HIGH
POWER
PAGE 2 OF 7 0217 IH-6369
Clean Filter
LED Indicator
FILTER TIMER
Fan Speed
LED Indicators
MEDIUM
LOW
FAN SPEED MODE
Increase/Decrease Room
Humidistat
Display
HUMIDITY %
Humidity Level
MyHome Mode
LED Indicators
SLEEPING SPACE
LIVING SPACE
BASEMENT
CONTINUOUS
Child-Lock
LED Indicator
LED Indicator
LOCK BUCKET FULL
TIMER
Timer
Bucket Full
LED Indicator

OPERATION
1. When first operating the dehumidifier, run it in
continuous mode for 24 hours.
2. Power On and Off – Press the POWER button once to
manually turn the unit on. Press the POWER button
once more to turn the unit off.
3. Humidity Selection – Press the or buttons
to choose the desired relative humidity in the
room. Each press of the button will change the
desired room humidity by 5%. The room humidity
is selectable from 35%-80% or continuous. The
unit will cycle on and off to maintain the humidity
level chosen on the digital display. If you want the
dehumidifier to operate continuously regardless
of the room humidity, press the MODE button until
you see "CO" on the digital display. This will enable
continuous operation and the "Continuous" indicator
will light up on the control panel.
4. Fan Speed Control – Press the FAN SPEED button
to cycle through the different fan speeds: high,
medium and low. The fan speed can be visually
distinguished by the fan speed indicators on the
control panel.
5.
Timer Auto On – To program the unit to automatically
turn on, press the TIMER button when the unit is off.
Press or to increase or decrease the timer in 30
minute increments (.5 hours) up to 10 hours. After 10
hours, each press of the button will increase the
timer in 1 hour increments up to 24 hours. Once the
desired time is reached, the unit will automatically
turn on.
Timer Auto Shut-Off – To program the unit to
automatically turn off, press the TIMER button when
the unit is on. Each press of the or buttons will
change the timer setting in 30 minute increments
(.5 hours) up to 10 hours. After 10 hours, each press of
the or buttons will increase or decrease the timer
in 1 hour increments up to 24 hours. Once the desired
time is over, the unit will automatically power off.
NOTE: Fan will continue to run even when the
compressor is off. This is normal and allows
the unit to circulate air and operate more
efficiently
6. Bucket Full – When the water bucket is full of water,
the unit will automatically shut off, make a beeping
noise and the Bucket Full Indicator will light up. The
dehumidifier will not function until the water bucket
is emptied and placed back inside the unit. The
bucket should be cleaned every few weeks to
prevent the growth of mold, mildew and bacteria.
Use a mild detergent to clean the bucket. Once
clean, completely dry the bucket and place it back
inside the dehumidifier. (See Figure 1)
Figure 1
NOTE: When the bucket is full or removed from
the machine, the compressor will turn off, but
the fan will continue to run for a few minutes. This
is completely normal. The dehumidifier will not
be removing moisture from the air at this time.
NOTE: When removing moisture from the air,
the dehumidifier will exhaust warm air from the
side exhaust vent.
NOTE: Do not place a full bucket on the floor,
because the bottom is uneven.
7. Clean Filter – When the filter needs to be cleaned,
the filter indicator will light up (after 250 hours of use).
Remove the filter from the back of the unit by using
your thumbs to press down on the filter tabs directly
above the filter. (See Figure 2) Clean the filter with
warm, soapy water. Dry thoroughly before replacing
the filter. Once the filter is completely dry, place the
filter back in the unit and press the FILTER button to
reset the filter indicator.
Figure 2
CAUTION! Do not operate the dehumidifier
without the included filter.
PAGE 3 OF 7 0217 IH-6369