Uline H5802 User manual

0 (0)

Para Español, vea páginas 5-8. Pour le français, consulter les pages 9-12.

H-5802

TEMPERATURE GUN

1-800-295-5510 uline.com

SAFETY

WARNING! Read all safety warnings and instructions. Failure to follow the warnings and instructions may result in electric shock, fire and serious injury. Save these instructions, as they contain important safety and operating instructions. Before using, read this manual and all labels on the temperature gun thoroughly.

LASER LIGHT

Do not stare into beam or view directly with optical instruments. Do not point laser light at others. Laser light can cause eye damage.

Avoid exposure to laser radiation. Laser may emit hazardous radiation.

Do not point laser at reflective surfaces. Unpredictable results may occur.

BATTERY USE AND CARE

This tool is designed to be powered by one 9V battery properly inserted into the temperature gun. Do not attempt to use with any other voltage or power supply.

Do not leave battery within reach of children.

Install battery according to polarity (+/–) diagrams.

Properly dispose of used battery immediately.

Do not incinerate or dismantle battery.

Under abusive conditions, liquid may be ejected from the battery – avoid contact. If contact accidentally occurs, flush with water. If liquid contacts eyes, seek medical help. Liquid ejected from battery may cause irritation or burns.

WORK AREA

Keep children and bystanders away while operating temperature gun. Store idle temperature gun out

of the reach of children, and do not allow persons unfamiliar with the tool or these instructions to operate the temperature gun.

Avoid dangerous environments. Do not use in rainy, snowy, damp or wet locations. Do not use in the presence of explosive atmospheres (i.e., gaseous fumes, dust or flammable materials) because sparks may be generated when inserting or removing battery, possibly causing fire.

PERSONAL

Stay alert, watch what you are doing and use common sense when operating temperature gun. Do not use while you are tired or under the influence of alcohol or medication. A moment of inattention may result in serious personal injury.

Do not overreach. Keep proper footing and balance at all times. This enables better control in unexpected situations.

SERVICE

Have your temperature gun serviced by a qualified repair person using only identical replacement parts. This will ensure that the safety of the tool is maintained.

Do not disassemble. Incorrect reassembly may result in the risk of electric shock or fire. If damaged, call Uline Customer Service at 1-800-295-5510.

Store in a cool, dry place. Do not store where temperatures may exceed 140°F (60°C), such as in direct sunlight, a vehicle or a metal building during the summer.

Do not remove or deface labels. Maintain labels and nameplates. These carry important information. If unreadable or missing, contact Uline Customer Service at 1-800-295-5510.

PAGE 1 OF 12

0621 IH-5802

Uline H5802 User manual

DIAGRAM

1

 

 

 

 

 

3

 

 

 

2

8

9

10

4

 

 

 

 

 

 

 

7

 

 

11

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

 

HOLD

 

12

 

 

 

 

 

 

 

 

 

6

MAX

 

 

13

 

 

 

 

 

 

 

 

 

 

 

MIN

 

 

 

 

 

 

15

AVG

 

 

14

 

 

 

OFF

 

 

 

 

 

SPECIFICATIONS

 

 

 

 

#

DESCRIPTION

Laser Type

Class II

 

 

 

 

1

Laser Window

Max Power

<1mW

 

 

 

 

2

Trigger

Wavelength

630-670 nm

 

 

 

 

3

Display

IR Temperature Range

-22° to 752°F

 

 

 

 

4

Mode/Set/Alarm Buttons

IR Accuracy

-22° to 0°F: ± 4°F + 0.2°/2°F

 

 

 

 

5

Battery Door Lock

 

0° to 32°F: ± 5°F

 

 

 

 

6

Battery Door

 

 

 

 

 

 

 

 

32° to 752°F ± 4°F or 2% of reading, whichever is greater.

7

Battery Indicator

 

8

Hold Indicator

 

Assume ambient operating temperature of 70° to 77°F

 

9

Laser Active Indicator

Minimum Measuring Distance

2" < 122°F; 4" > 122°F

 

 

 

 

 

 

 

 

10

Trigger Lock Indicator

Temperature Display Resolution

0.1°F in Primary and Secondary

 

 

 

 

 

 

11

Alarm Indicator

 

 

 

 

 

 

Emmissivity

0.95

 

 

 

 

12

Celsius or Fahrenheit Indicator

 

 

 

 

 

 

Response Time

<500 msec

 

 

 

 

13

Primary Measurement

 

 

 

 

 

 

Spectral Response

8 to 14µm

 

 

 

 

14

Secondary Measurement

 

 

 

 

 

 

Distance to Spot

10 to 1

 

 

 

 

15

Mode Indicator

 

 

 

 

 

 

Drop

2 meters

 

 

 

 

 

 

Repeatability

±0.8% or ±2°F (whichever is greater)

 

 

 

 

Operating Temperature

32° to 122°F

 

 

 

 

 

 

Storage Temperature

-4° to 140°F without battery

 

 

 

 

 

 

Relative Humidity

10 to 85% at 77°F, decreasing linearly to 10 to 45% at 122°F

 

 

Voltage

9 DC (one 9V battery)

 

 

 

 

 

 

Battery Life

>12 hours with all functions

 

 

 

 

 

 

PAGE 2 OF 12

0621 IH-5802

ASSEMBLY

LOADING/CHANGING THE BATTERY

1.Using a flathead screwdriver, rotate the battery

 

door lock to the unlocked position and

 

 

open the battery door.

 

2.

Connect one 9V battery to the

 

 

connector block. Fit the battery

 

 

into the compartment.

 

 

(See Figure 1)

 

3.

Close the battery door. Turn the

Figure 1

 

battery lock to the locked position.

 

 

SELECTING CELSIUS OR FAHRENHEIT

To set the temperature scale, pull the trigger, then press the SET button three times. Press the buttons above the up and down arrows to toggle between "C" and "F." Wait five seconds for the setting to save and exit.

SETTING THE LASER LOCK

To turn the laser on and off, pull the trigger, then press the SET button four times. Press the buttons above the up and down arrows to toggle between ON and OFF. Wait five seconds for the setting to save and exit.

OPERATION

SCANNING OBJECT TEMPERATURE

1.Pull and hold the trigger for at least two seconds and scan the surface temperature of an object. A laser pointer is used for aiming on the area being scanned.

NOTE: The object should be larger than the spot being scanned. If not, readings will be affected. See Figure 2 for necessary object size.

2.As you continue to hold the trigger, the icon is displayed along with the primary measurement (surface temperature) and secondary measurement (maximum, minimum, average or differential temperature) readings.

3.Release the trigger. HOLD is displayed until the screen shuts off in about ten seconds.

1560

MAX 2183

15HOLD60 MAX 2183

NOTE: A quick change in temperature (>10°F) affects the meter’s readings. Allow the meter to reach ambient temperature before use (5 to 30 minutes, depending on temperature change).

DISTANCE TO SPOT – 10:1

Figure 2

—— Center of Spot

– – – Laser pointer (approx. 3/4" above center of spot) Spot size at distance indicated

 

 

At 1' away,

 

At 3' away,

spot is 1½"

At 5' away,

spot is 3.6"

in diameter

in diameter

 

spot is 6"

 

 

in diameter

 

 

PAGE 3 OF 12

 

 

SETTING THE TRIGGER LOCK

1.To turn the trigger lock on and off, pull the trigger, then press the SET button five times. Press the buttons above the up and down arrows to toggle between ON and OFF. Wait five seconds for the setting to save and exit.

TEMPERATURE ALARM

1.Press the ALARM button to turn on the alarm function.

2.The bell icon is displayed. If the temperature reading is outside the preset range, the temperature reading will flash and an alarm will sound.

SETTING PRESET RANGE FOR THE ALARM

1.To set the alarm range, pull and hold the trigger, then press the SET button. Repeat to toggle between LO and HI settings.

2.Press the up or down arrow soft keys to toggle between temperatures. Wait five seconds for the ranges to save and exit.

LOW BATTERY

1560

MAX 2183

2169

MAX HI

321

LO

1560

MAX 2183

When the low battery icon is displayed, change the battery.

WARNING! Always remove battery before changing or removing accessories. Only use accessories specifically recommended for this tool. Others may be hazardous.

Mode

Description

 

 

MAX

Displays maximum temperature measured during a

continuous reading.

 

 

 

MIN

Displays minimum temperature measured during a

continuous reading.

 

 

 

AVG

Displays average temperature of last 20 measurements

during a continuous reading.

 

 

 

DIF

Displays the difference between MAX and MIN during a

continuous reading.

 

 

 

 

0621 IH-5802

MAINTENANCE

WARNING! To reduce the risk of injury, always remove the battery from the tool before performing any maintenance. Never

disassemble the tool. Contact Uline Customer Service at 1-800-295-5510 for all repairs.

MAINTAINING TOOL

Keep your tool in good condition by adopting a regular maintenance program.

If the tool does not start or operate at full power with new battery, clean the contacts on the battery door.

If the tool still does not work properly, contact Uline Customer Service at 1-800-295-5510.

CLEANING THE LENS

1.Blow off loose particles with clean compressed air.

2.Carefully wipe the surface with a cotton swab moistened with water.

3.Using a second cotton swab, dry completely.

WARNING! To reduce the risk of personal injury and damage, never immerse your tool in liquid or allow a liquid to flow inside it.

CLEANING

Clean dust and debris from tool.

Keep tool handle clean, dry and free of oil or grease.

Use only mild soap and a damp cloth to clean the tool, since certain cleaning agents and solvents are harmful to plastics and other insulated parts. Some of these include gasoline, turpentine, lacquer thinner, paint thinner, chlorinated cleaning solvents, ammonia and household detergents containing ammonia.

Never use flammable or combustible solvents around tools.

REPAIRS

For repairs, contact Uline Customer Service at 1-800-295-5510.

1-800-295-5510

PAGE 4 OF 12

uline.com

0621 IH-5802