WARNING! Read all safety warnings and
instructions. Failure to follow the warnings and
instructions may result in electric shock, fire
and serious injury. Save these instructions, as
they contain important safety and operating
instructions. Before using, read this manual and
all labels on the temperature gun thoroughly.
1-800-295-5510
uline.com
LASER LIGHT
• Do not stare into beam or view directly with optical
instruments. Do not point laser light at others. Laser
light can cause eye damage.
• Avoid exposure to laser radiation. Laser may emit
hazardous radiation.
• Do not point laser at reflective surfaces.
Unpredictable results may occur.
SAFETY
BATTERY USE AND CARE
• This tool is designed to be powered by one 9V
battery properly inserted into the temperature gun.
Do not attempt to use with any other voltage or
power supply.
• Do not leave battery within reach of children.
• Install battery according to polarity (+/–) diagrams.
• Properly dispose of used battery immediately.
• Do not incinerate or dismantle battery.
• Under abusive conditions, liquid may be ejected
from the battery – avoid contact. If contact
accidentally occurs, flush with water. If liquid
contacts eyes, seek medical help. Liquid ejected
from battery may cause irritation or burns.
WORK AREA
• Keep children and bystanders away while operating
temperature gun. Store idle temperature gun out
of the reach of children, and do not allow persons
unfamiliar with the tool or these instructions to
operate the temperature gun.
• Avoid dangerous environments. Do not use in rainy,
snowy, damp or wet locations. Do not use in the
presence of explosive atmospheres (i.e., gaseous
fumes, dust or flammable materials) because sparks
may be generated when inserting or removing
battery, possibly causing fire.
PERSONAL
• Stay alert, watch what you are doing and use
common sense when operating temperature gun.
Do not use while you are tired or under the influence
of alcohol or medication. A moment of inattention
may result in serious personal injury.
• Do not overreach. Keep proper footing and
balance at all times. This enables better control in
unexpected situations.
SERVICE
• Have your temperature gun serviced by a qualified
repair person using only identical replacement
parts. This will ensure that the safety of the tool is
maintained.
• Do not disassemble. Incorrect reassembly may result
in the risk of electric shock or fire. If damaged, call
Uline Customer Service at 1-800-295-5510.
• Store in a cool, dry place. Do not store where
temperatures may exceed 140°F (60°C), such as in
direct sunlight, a vehicle or a metal building during
the summer.
• Do not remove or deface labels. Maintain labels
and nameplates. These carry important information.
If unreadable or missing, contact Uline Customer
Service at 1-800-295-5510.
PAGE 1 OF 12 0621 IH-5802
DIAGRAM
1
3
9
HOLD
10
11
12
13
1415
2
8
7
5
6
MAX
MIN
AVG
OFF
SPECIFICATIONS
Laser TypeClass II
Max Power<1m W
Wavelength630-670 nm
IR Temperature Range-22° to 752°F
IR Accuracy-22° to 0°F: ± 4°F + 0.2°/2°F
0° to 32°F: ± 5°F
32° to 752°F ± 4°F or 2% of reading, whichever is greater.
Assume ambient operating temperature of 70° to 77°F
Minimum Measuring Distance2" < 122°F; 4" > 122°F
Temperature Display Resolution 0.1°F in Primary and Secondary
Emmissivity0.95
Response Time<500 msec
Spectral Response8 to 14µm
Distance to Spot10 to 1
Drop2 meters
Repeatability±0.8% or ±2°F (whichever is greater)
Operating Temperature32° to 122°F
Storage Temperature-4° to 140°F without battery
Relative Humidity10 to 85% at 77°F, decreasing linearly to 10 to 45% at 122°F
Voltage9 DC (one 9V battery)
Battery Life>12 hours with all functions
4
#DESCRIPTION
1Laser Window
2Trigger
3Display
4Mode/Set/Alarm Buttons
5Battery Door Lock
6Battery Door
7Battery Indicator
8Hold Indicator
9Laser Active Indicator
1. Using a flathead screwdriver, rotate the battery
door lock to the unlocked position and
open the battery door.
2. Connect one 9V battery to the
connector block. Fit the battery
into the compartment.
(See Figure 1)
3. Close the battery door. Turn the
battery lock to the locked position.
Figure 1
OPERATION
SCANNING OBJECT TEMPERATURE
1. Pull and hold the trigger for at least two seconds
and scan the surface temperature of an object. A
laser pointer is used for aiming on the area being
scanned.
NOTE: The object should be larger than the
spot being scanned. If not, readings will be
affected. See Figure 2 for necessary object size.
2. As you continue to hold the trigger, the
icon is displayed along with the
primary measurement (surface
temperature) and secondary
measurement (maximum, minimum,
average or differential temperature)
readings.
3. Release the trigger. HOLD is displayed
until the screen shuts off in about ten
seconds.
NOTE: A quick change in temperature (>10°F)
affects the meter’s readings. Allow the meter to
reach ambient temperature before use (5 to 30
minutes, depending on temperature change).
DISTANCE TO SPOT – 10:1
—— Center of Spot
– – – Laser pointer (approx. 3/4" above center of spot)
Spot size at distance indicated
516
MAX
HOLD
516
MAX
Figure 2
0
3
0
3
SELECTING CELSIUS OR FAHRENHEIT
To set the temperature scale, pull the trigger, then press
the
SET
button three times. Press the buttons above the
up and down arrows to toggle between "C" and "F." Wait
five seconds for the setting to save and exit.
SETTING THE LASER LOCK
To turn the laser on and off, pull the trigger, then press
the
SET
button four times. Press the buttons above the up
and down arrows to toggle between ON and OFF. Wait
five seconds for the setting to save and exit.
SETTING THE TRIGGER LOCK
1. To turn the trigger lock on and off, pull the trigger, then
press the
the up and down arrows to toggle between ON and
OFF. Wait five seconds for the setting to save and exit.
SET
button five times. Press the buttons above
TEMPERATURE ALARM
1. Press the
alarm function.
2. The bell icon is displayed. If the
temperature reading is outside the preset
range, the temperature reading will flash
and an alarm will sound.
ALARM
button to turn on the
516
MAX
MAX
812
16
0
3
9
HI
SETTING PRESET RANGE FOR THE ALARM
1. To set the alarm range, pull and hold the
trigger, then press the
toggle between LO and HI settings.
2. Press the up or down arrow soft keys to
toggle between temperatures. Wait five
seconds
for the ranges to save and exit.
LOW BATTERY
When the low battery icon is displayed, change the battery.
WARNING! Always remove battery before
changing or removing accessories. Only use
accessories specifically recommended for this
tool. Others may be hazardous.
SET
button. Repeat to
32
LO
516
MAX
0
1
ModeDescription
MAX
At 1' away,
At 3' away,
At 5' away,
spot is 6"
in diameter
PAGE 3 OF 12 0621 IH-5802
spot is 3.6"
in diameter
spot is 1½"
in diameter
AVG
Displays maximum temperature measured during a
continuous reading.
Displays minimum temperature measured during a
MIN
continuous reading.
Displays average temperature of last 20 measurements
during a continuous reading.
Displays the difference between MAX and MIN during a
DIF
continuous reading.
MAINTENANCE
1
0
uline.com
WARNING! To reduce the risk of injury,
always remove the battery from the tool
before performing any maintenance. Never
disassemble the tool. Contact Uline Customer
Service at 1-800-295-5510 for all repairs.
MAINTAINING TOOL
• Keep your tool in good condition by adopting a
regular maintenance program.
• If the tool does not start or operate at full power with
new battery, clean the contacts on the battery door.
• If the tool still does not work properly, contact Uline
Customer Service at 1-800-295-5510.
CLEANING THE LENS
1. Blow off loose particles with clean compressed air.
2. Carefully wipe the surface with a cotton swab
moistened with water.
3. Using a second cotton swab, dry completely.
WARNING! To reduce the risk of personal injury
and damage, never immerse your tool in liquid
or allow a liquid to flow inside it.
CLEANING
• Clean dust and debris from tool.
• Keep tool handle clean, dry and free of oil or
grease.
• Use only mild soap and a damp cloth to clean the
tool, since certain cleaning agents and solvents
are harmful to plastics and other insulated parts.
Some of these include gasoline, turpentine, lacquer
thinner, paint thinner, chlorinated cleaning solvents,
ammonia and household detergents containing
ammonia.
• Never use flammable or combustible solvents
around tools.
REPAIRS
For repairs, contact Uline Customer Service
at 1-800-295-5510.
-800-295-551
PAGE 4 OF 12 0621 IH-5802
Loading...
+ 8 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.