Congratulations on your U-Line purchase. Your product comes from a company with over five decades and three generations
of premium modular ice making, refrigeration, and wine preservation experience. U-Line continues to be the American
leader, delivering versatility and flexibility for multiple applications including residential, light commercial, outdoor and marine
use. U-Line’s complete product collection includes modular Wine Captain
Crescent Ice Makers, Glass & Solid Door Refrigerators, Drawer Models, Freezers, and Combo® Models.
U-Line has captivated those with an appreciation for the finer things with exceptional functionality, style, inspired innovations
and attention to even the smallest details. We are known and respected for our unwavering dedication to product design,
quality and selection. U-Line is headquartered in Milwaukee, Wisconsin and has shipped product to five continents for over
two decades and is proud to have the opportunity to ship to you.
PRODUCT INFORMATION
Looking for additional information on your product? User Guides, Quick Reference Guides, CAD Drawings, Compliance
Documentation, and Product Warranty information are all available for reference and download at u-line.com.
®
Models, Beverage Centers, Clear Ice Machines,
PROPERTY DAMAGE / INJURY CONCERNS
In the unlikely event property damage or personal injury is suspected related to a U-Line product, please take the following
steps:
1. U-Line Customer Care must be contacted immediately at +1.800.779.2547.
2. Service or repairs performed on the unit without prior written approval from U-Line is not permitted. If the unit has been
altered or repaired in the field without prior written approval from U-Line, claims will not be eligible.
SERVICE INFORMATION
Answers to Customer Frequently Asked Questions are available at u-line.com under Customer Care or you may contact our
Customer Care group directly, contact information below.
GENERAL INQUIRIES
U-Line Corporation
8900 N. 55th Street
Milwaukee, Wisconsin 53223 USA
Monday - Friday 8:00 am to 4:30 pm CST
T: +1.414.354.0300
F: +1.414.354.7905
Email: sales@u-line.com
u-line.com
SERVICE & PARTS ASSISTANCE
Monday - Friday 8:00 am to 4:30 pm CST
T: +1.800.779.2547
F: +1.414.354.5696
Service Email: onlineservice@u-line.com
Parts Email: onlineparts@u-line.com
CONNECT WITH US
Designed, engineered, and assembled in WI, USA
Page 3
QUICK START GUIDE
plus
eligible
1
warrantywarranty
u-line.com
This Quick Start Guide covers the basics of installation and general use of your product. For more details, see the
complete User Guide & Service Manual on u-line.com.
Contents
1Safety and Warning
1Environmental Requirements
2Electrical
2Water Hookup
6Drain
7Door Swing
8General Installation
8Integrated Panel Installation
10Control Operation
10First Use
10Ice
12Sabbath Mode
13Warranty
This product is eligible for an additional one-year warranty at no charge when you register your product on
u-line.com. See complete warranty for details.
Page 4
QUICK START GUIDE
NOTICE
u-line.com
Safety and Warning
Please read all instructions before installing,
operating, or servicing the appliance.
Use this appliance for its intended purpose only and follow
these general precautions with those listed throughout this
guide:
SAFETY ALERT DEFINITIONS
Throughout this guide are safety items labeled with a
Danger, Warning or Caution based on the risk type:
DANGER
!
Danger means that failure to follow this safety
statement will result in severe personal injury or
death.
WARNING
!
Warning means that failure to follow this safety
statement could result in serious personal injury
or death.
This unit is designed to operate between 50°F (10°C) and
100°F (38°C). Higher ambient temperatures may reduce
the unit’s ability to reach low temperatures and/or reduce
ice production on applicable models.
For best performance, keep the unit out of direct sunlight
and away from heat generating equipment.
In climates where high humidity and dew points are
present, condensation may appear on outside surfaces.
This is considered normal. The condensation will
evaporate when the humidity drops.
CAUTION
!
Damages caused by ambient temperatures of
40°F (4°C) or below are not covered by the
warranty.
OUTDOOR UNITS
This unit is designed to operate between 50°F (10°C) and
100°F (38°C). Higher ambient temperatures may reduce
the unit’s ability to reach low temperatures and/or reduce
ice production on applicable models.
For best performance, keep the unit out of direct sunlight
and away from heat generating equipment.
CAUTION
!
Caution means that failure to follow this safety
statement may result in minor or moderate
personal injury, property or equipment damage.
Environmental Requirements
115 V UNITS
This model is intended for indoor/interior applications only
and is not to be used in installations that are open/
exposed to natural elements.
In climates where high humidity and dew points are
present, condensation may appear on outside surfaces.
This is considered normal. The condensation will
evaporate when the humidity drops.
CAUTION
!
Damages caused by ambient temperatures of
40°F (4°C) or below are not covered by the
warranty.
1
Page 5
QUICK START GUIDE
NOTICE
u-line.com
Electrical
WARNING
!
SHOCK HAZARD — Electrical Grounding
Required. Never attempt to repair or perform
maintenance on the unit until the electricity has
been disconnected.
Never remove the round grounding prong from
the plug and never use a two-prong grounding
adapter.
Altering, cutting or removing power cord,
removing power plug, or direct wiring can cause
serious injury, fire, loss of property and/or life,
and will void the warranty.
Never use an extension cord to connect power to
the unit.
Always keep your working area dry.
Water Hookup
PREPARE PLUMBING
The water valve uses a standard 1/4" (6.35 mm)
compression fitting. A 10' (3 m) braided flexible water
supply line is included with the unit.
WARNING
!
Prior to installation, determine if this product
contains a gravity style drain or factory installed
drain pump. Products without a drain pump may
only use a gravity style drain. Failure to connect
water supply or drain line connections properly
may result in water leakage, personal injury,
and/or property damage. Disconnect power and
turn off water to the unit before attempting to
alter these connections. These connections are
the responsibility of the owner and must be
connected per local plumbing code. If you are
uncertain of how to safely and properly install
this product, contact a licensed plumber.
Electrical installation must observe all state and
local codes. This unit requires connection to a
grounded (three-prong), polarized receptacle
that has been placed by a qualified electrician.
The unit requires a grounded and polarized 115 VAC,
60 Hz, 15A power supply (normal household current). An
individual, properly grounded branch circuit or circuit
breaker is recommended. A GFCI (ground fault circuit
interrupter) is usually not required for fixed location
appliances and is not recommended for your unit because
it could be prone to nuisance tripping. However, be sure
to consult your local codes
Water Supply Connection
WARNING
!
Connect to potable water supply only.
CAUTION
!
Review, obey, and understand the local
plumbing codes before you install your unit.
Connect to the cold water supply. The water
pressure should be between 20 and 120 psi (138
and 827 kPa). The water line MUST
off valve on the supply line.
have a shut-
2
Page 6
QUICK START GUIDE
Remove
ZLWKɠDW
screwdriver
CAUTION
!
Do not use any plastic water supply line. The line
is under pressure at all times. Plastic may crack
or rupture with age and cause damage to your
home.
Do not use tape or joint compound when
attaching a braided flexible water supply line
that includes a rubber gasket. The gasket
provides an adequate seal – other materials
could cause blockage of the valve.
Failure to follow recommendations and
instructions may result in damage and/or harm,
flooding or void the product warranty.
u-line.com
3. Locate water
valve in the front
of the unit and
thread water
supply line
through.
Route the water
supply line
through the unit
so it does not
come into contact with any internal components
other than the solenoid valve. Normal operation
creates some vibration. A water supply line
contacting an internal component or cabinet wall
can cause excessive noise during operation or
damage to the line.
CAUTION
!
Turn off water supply and disconnect electrical
supply to unit prior to installation.
Use caution when handling back panel. The
edges could be sharp.
1. Turn off water supply and disconnect electrical supply
to product prior to attempting installation.
2. Remove the grille/access panel in the front and the
back panel.
4. On the back panel,
break away filler feature
in bushing with flat
screwdriver.
5. Thread water line
through back panel hole
(with bushing) and
connect to cold water
supply line.
6. Turn on water supply and check for leaks.
7. Reinstall back panel and grille/front access panel.
3
Page 7
QUICK START GUIDE
u-line.com
8. Install retaining clip.
OUTDOOR MODELS
PREPARE PLUMBING
The water valve uses a standard 1/4" (6.35 mm)
compression fitting. U-Line recommends using accessory
water hook up kit – part # WATERHOOKUP. The kit
includes a 10' (3 m) braided flexible water supply line and
a brass hose fitting. When using a 1/4" (6.35 mm) O.D.
soft copper supply line use the brass nut and sleeve
included with the unit.
WARNING
!
Water Supply Connection
WARNING
!
Connect to potable water supply only.
CAUTION
!
Review, obey, and understand the local
plumbing codes before you install your unit.
Connect to the cold water supply. The water
pressure should be between 20 and 120 psi (138
and 827 kPa). The water line MUST
off valve on the supply line.
CAUTION
!
Do not use any plastic water supply line. The line
is under pressure at all times. Plastic may crack
or rupture with age and cause damage to your
home.
Do not use tape or joint compound when
attaching a braided flexible water supply line
that includes a rubber gasket. The gasket
provides an adequate seal – other materials
could cause blockage of the valve.
have a shut-
Prior to installation, determine if this product
contains a gravity style drain or factory installed
drain pump. Products without a drain pump may
only use a gravity style drain. Failure to connect
water supply or drain line connections properly
may result in water leakage, personal injury,
and/or property damage. Disconnect power and
turn off water to the unit before attempting to
alter these connections. These connections are
the responsibility of the owner and must be
connected per local plumbing code. If you are
uncertain of how to safely and properly install
this product, contact a licensed plumber.
Failure to follow recommendations and
instructions may result in damage and/or harm,
flooding or void the product warranty.
CAUTION
!
Turn off water supply and disconnect electrical
supply to unit prior to installation.
Use caution when handling back panel. The
edges could be sharp.
4
Page 8
QUICK START GUIDE
NOTICE
Remove
ZLWKɠDW
screwdriver
u-line.com
1. Turn off water supply and disconnect electrical supply
to product prior to attempting installation.
2. Remove the
grille/access
panel in the front
and the back
panel.Locate
water valve in the
front of the unit
and thread water
supply line
through.
Route the water supply line through the unit so
it does not come into contact with any internal
components other than the solenoid valve.
Normal operation creates some vibration. A
water supply line contacting an internal
component or cabinet wall can cause excessive
noise during operation or damage to the line.
7. Install retaining clip.
3. On the back panel,
break away filler feature
in bushing with flat
screwdriver.
4. Thread water line
through back panel hole
(with bushing).
5. Turn on water supply and check for leaks.
6. Reinstall back panel and grille/front access panel.
5
Page 9
QUICK START GUIDE
NOTICE
Normal
Proper Drain
With Trap
Poor Drainage, Water Will Back Up
With Trap and Vent
Proper Drain
u-line.com
Drain
Model numbers including “-00” or “-07” do not include a
factory installed drain pump.
Model numbers including “-40” or “-47” include a factory
installed drain pump.
DRAIN CONNECTION
CAUTION
!
If your U-Line unit did not come with a factory
installed drain pump you must use a gravity
style drain connection. For assistance in
determining if your unit has a pump please
contact U-Line. The floor drain must be large
enough to accommodate drainage from all
attached drains. Follow these guidelines when
installing drain lines to prevent water from
flowing back into the ice maker storage bin and/
or potentially flowing onto the floor, which may
result in personal injury or property damage.
GRAVITY DRAIN
A gravity drain may be used if:
Drain line has at least a 1" drop per 48" (approximately
2 cm drop per 100 cm) of run.
Drain line does not create traps and is vented per local
code.
1. Cut the pre-installed drain tube to length.
Drain can NOT be located directly below the unit.
Unit has a solid base that will not allow the unit
to drain below itself.
There is a possibility that hose connections may
have loosened during shipment.
Verify all connections and fittings are free from
leaks.
2. Connect to your local plumbing per the local code.
3. If necessary, insulate drain line to prevent
condensation.
CAUTION
!
Failure to connect water supply or drain line
connections properly can result in personal
injury and property damage. Gravity drain
connections must be routed downward from the
rest of the unit at the rate of 1/4" per foot (1 cm
per 50 cm).
6
Page 10
QUICK START GUIDE
NOTICE
Cold
Water
Hot
Water
Waste
Waste
6KXW2ɞ
Valve
Stand Pipe
P60 Pump Required
Air Gap
(Optional Hook-Up)
Cold
Water
Hot
Water
Waste
6KXW2ɞ
Valve
Disposal Assembly
P60 Pump Required
Cold
r
6KXW2ɞ
Valve
Hot
Water
Air Gap
(Optional Hook-Up)
P60 Pump Required
WallWall
90°
Door Swing
90°
Door Swing
2-1/8" Min.
(54 mm)
1/4" Min.
(6 mm)
u-line.com
FACTORY INSTALLED DRAIN PUMP
If your drain line will run up to a stand pipe, disposal or
spigot assembly, or does not otherwise meet the
requirements for a gravity drain, you may have ordered a
pre-installed U-Line P60 drain pump.
If you need to install a P60 drain pump into your unit, see
DRAIN PUMP section in the User Manual.
See below for typical installations requiring a drain pump.
Y-Branch Tailpiece
Waste
Wate
The maximum lift for the P60 drain pump is
10 feet. This must be done as close to the rear of
the unit as possible.
Door Swing
Units have a zero clearance for the door to open 90°,
when installed adjacent to cabinets.
Stainless Steel and black and white models require 2-1/8"
(54 mm) door clearance to accommodate the handle if
installed next to a wall.
Integrated models require 1/4" (6 mm) clearance if
installed next to a wall. Allow for additional space for any
knobs or pulls installed on the integrated panel/frame.
7
Page 11
QUICK START GUIDE
Turn to Adjust
u-line.com
General Installation
LEVELING INFORMATION
1. Use a level to
confirm the unit is
level. Level should
be placed along top
edge and side edge
as shown.
1
2. If the unit is not level, adjust the legs on the corners of
the unit as necessary.
INSTALLATION
1. Plug in the power/electrical cord.
2. Gently push the unit into position. Be careful not to
entangle the cord or water and drain lines.
3. Re-check the leveling, from front to back and side to
side. Make any necessary adjustments. The unit’s top
surface should be approximately 1/8" (3 mm) below
the counter top.
4. Install the anti-tip bracket.
5. Remove interior packing material and wipe out the
inside of the unit with a clean, water-dampened cloth.
Integrated Panel Installation
1. Fully open door/drawer.
3. Confirm the unit is level after each adjustment and
repeat the previous steps until the unit is level.
INSTALLATION TIP
If the room floor is higher than the floor in the cutout
opening, adjust the rear legs to achieve a total unit rear
height of 1/8" (3 mm) less than the opening’s rear height.
Shorten the unit height in the front by adjusting the front
legs. This allows the unit to be gently tipped into the
opening. Readjust the front legs to level the unit after it is
correctly positioned in the opening.
2. Starting at corner, pull
gasket away from door/
drawer.
3. Continue to pull gasket
free from gasket channel.
4. Upon removal, lay gasket
down on a flat surface.
5. Partially loosen the 3 screws, securing the top hinge to
the cabinet.
6. Align the panel with the outside edge (opposite the
hinge) and high enough to align with the highest point
in the door/drawer.
7. Insert panel underneath top hinge and apply upward
pressure while bringing the lower portion of the panel
flush to the door inside the lower hinge. The panel will
fit snuggly
8
Page 12
QUICK START GUIDE
Align Panel
Against
Door/Drawe
Edge First
Align Top Of Panel With Highest Point Of Door/Drawer
Door
Panel
Integrated Panel
Integrated Panel
u-line.com
8. Align door with cabinet. Tighten the top 3 screws,
securing the top hinge to the cabinet.
Due to differences in floor construction or
surrounding cabinetry, the panel may not sit
flush with the top of the door/drawer.
It is important to ensure that all drilled holes are
drilled to the correct depth in order to avoid
splits in the wood when hardwood is installed.
11.Locate 6 of the #6x 1-1/4" (32 mm) screws provided
with your unit.
12.Using a Phillips screwdriver, place one screw into each
of the 6 pilot holes and screw down. Do not overtighten
screws.
13.Be sure the screws force their way past the opening on
the gasket channel and sit flush against the bottom of
the channel.
9. Secure integrated
panel to door/drawer
Clamp
using clamps. A
robust tape may also
be used. U-Line
recommends the use
of bar clamps to
Door/Drawer
secure the panel to
the door/drawer. If
using tape, be
Wood
Panel
certain the tape will
not damage panel
finish upon removal.
10.Using a 7/64" (3 mm)
Clamp
drill bit, drill 6 pilot
holes into the wood
panel 1/2" (12 mm)
deep using the holes in the door/drawer frame as a
guide.
Bar
Bar
14.Remove clamps from door/drawer.
If panel requires additional adjustment after
removing clamps, slightly loosen each screw and
adjust panel as necessary. Tighten screws upon
completion.
15.Starting at the corners, re-install the gasket into the
gasket channel in the frame. Make sure the gasket is
fully seated. This may take some force.
9
Page 13
QUICK START GUIDE
NOTICE
NOTICE
Up DownLight Power Clean
LED
and
and
Control Operation
CONTROL FUNCTION GUIDE
FUNCTIONCOMMANDDISPLAY/OPTIONS
ON/OFFPress and releaseUnit will immediately turn ON or OFF.
Adjust ice thicknessSee “Ice” section
u-line.com
View temperature in unitPress together and release
Toggle between F/CHold for five secondsThe display will beep and display unit temperature.
Sabbath ModeSee “Sabbath Mode” section
Silent Mode (ice
production suspended for
3 hours)
Clean ModeHold for five seconds
Hold
and Display will show “OFF”.
First Use
All U-Line controls are preset at the factory. Initial startup
requires no adjustments.
U-Line recommends discarding the ice produced
during the first two to three hours of operation
to avoid possible dirt or scale that may dislodge
from the water line.
When plugged in, the unit will begin operating under the
factory default settings. If the unit was turned off during
installation, simply press and the unit will immediately
switch on. To turn the unit off, press and hold for
5 seconds and release.
The display will flash and then toggle from set point
to temperature in unit.
Ice
ICE CUBE THICKNESS ADJUSTMENT
Ice thickness adjustment should only be made
one increment at a time. Allow ice maker
production to stabilize for 24 hours before
rechecking ice thickness.
Ice is produced in layers resulting in a clear cube. Ice in
bin may develop surface frost which disappears when cube
is placed in liquid.
Ice cubes in any given batch will vary, so it is necessary
to choose cubes from the sample area for comparison
when making adjustments.
10
Page 14
QUICK START GUIDE
DIMPLES
ICE BRIDGE
7/8"
(22 mm)
7/8"
(22 mm)
THINNER BRIDGE
THICKER BRIDGE
DEEPER DIMPLE
SHALLOWER DIMPLE
1/4" TO 1/2"
(6.4 mm to 12.7 mm)
DIMPLE
1/16" TO 1/8"
(1.6 mm to 3.2 mm)
ICE BRIDGE
Cube Details
Factory Default Setting - 0
< 0
SETTING
> 0
SETTING
u-line.com
The ice cube thickness is factory set for best overall
performance. The factory setting is designed to maintain
an ice bridge of approximately 1/16" to 1/8" (1.6 mm to
3.2 mm) under normal conditions, resulting in a dimple of
approximately 1/4" to 1/2" (6.4 mm to 12.7 mm) in
depth. A fuller cube with less of a dimple results in a
thicker ice bridge. As the ice bridge becomes thicker, the
tendency for the cubes to stay together as a slab
increases. A bridge thicker than 1/8" (3.2 mm) may cause
cubes to overfill the ice bucket.
32 ice cubes are formed on a 4 x 8 slab during each cycle.
Each cycle takes approximately 15-20 minutes at the
default cube thickness (0).
Your clear ice machine is pre-set to produce ice between
the optimal dimensions illustrated below:
Ice thickness adjustments are made using the control
panel as follows:
1. To enter the thickness adjustment mode:
• Press and hold for 5 seconds.
• The display will switch to “0” to confirm the
thickness adjustment mode has been selected.
The factory setting is “0”. Use to raise the setting and
thicken the ice bridge, or to lower the setting to thin
the ice bridge.
Ice cubes in any given batch will vary, so it is necessary
to choose cubes from the sample area for comparison
U-Line Clear Ice Machine models are Star-K certified and
can be used during the Sabbath. View a full list of Star-K
certified U-Line units at www.star-k.org.
To prepare the unit for the Sabbath:
1. Press and hold the until the unit turns off.
2. No new ice will form when the unit is off, but previously
made ice will still be accessible/present for over 24
hours. Pump equipped models will continue to remove
water as needed even if the unit is off.
Sabbath Mode remains active until is pressed again
and the unit turns on.
12
Page 16
U-Line Corporation (U-Line) Limited Warranty
One Year Limited Warranty
For one year from the date of original purchase, this U-Line product warranty covers all parts and labor to repair or replace
any part of the product that proves to be defective in materials or workmanship. For products installed and used for normal
residential use, material cosmetic defects are included in this warranty, with coverage limited to 60 days from the date of
original purchase. All service provided by U-Line under the above warranty must be performed by U-Line factory authorized
service, unless otherwise specified by U-Line. Service provided during normal business hours.
Available Second Year Limited Warranty
Beyond the standard one year warranty outlined above, U-Line offers an extension of the one year warranty coverage for an
additional second year from the date of purchase, free of charge. To take advantage of this second year warranty, you must
register your product with U-Line within two months from the date of purchase at u-line.com providing proof of purchase.
Five Year Sealed System Limited Warranty
For five years from the date of original purchase, U-Line will repair or replace the following parts, labor not included, that
prove to be defective in materials or workmanship: compressor, condenser, evaporator, drier, and all connecting tubing. All
service provided by U-Line under the above warranty must be performed by U-Line factory authorized service, unless
otherwise specified by U-Line. Service provided during normal business hours.
Ter ms
These warranties apply only to products installed in any one of the fifty states of the United States, the District of Columbia,
or the ten provinces of Canada. The warranties do not cover any parts or labor to correct any defect caused by negligence,
accident or improper use, maintenance, installation, service, repair, acts of God, fire, flood or other natural disasters. The
product must be installed, operated, and maintained in accordance with the U-Line User Guide.
The remedies described above for each warranty are the only ones that U-Line will provide, either under these warranties or
under any warranty arising by operation of law. U-Line will not be responsible for any consequential or incidental damages
arising from the breach of these warranties or any other warranty, whether express, implied, or statutory. Some states do
not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not
apply to you. These warranties give you specific legal rights, and you may also have other rights which vary from state to
state.
Any warranty that may be implied in connection with your purchase or use of the product, including any warranty of
merchantability or any warranty fit for a particular purpose is limited to the duration of these warranties, and only extends to five
years in duration for the parts described in the section related to the five year limited warranty above. Some states do not allow
limitations on how long an implied warranty lasts, so the above limitations may not apply to you.
• The warranties only apply to the original purchaser and are non-transferable.
• The second year and five year warranties cover products installed and used for normal residential or designated marine
use only.
• The warranties apply to units operated outside only if designed for outdoor use by model and serial number.
• Replacement water filters, light bulbs, and other consumable parts are not covered by these warranties.
• The start of U-Line’s obligation is limited to four years after the shipment date from U-Line.
• In-home instruction on how to use your product is not covered by these warranties.
• Food, beverage, and medicine loss are not covered by these warranties.
• If the product is located in an area where U-Line factory authorized service is not available, you may be responsible for
a trip charge or you may be required to bring the product to a U-Line factory authorized service location at your own
cost and expense.
• Units purchased after use as floor displays are covered by the limited one year warranty only and no coverage is
provided for cosmetic defects.
• Signal issues related to Wi-Fi connectivity are not covered by these warranties.
For parts and service assistance, or to find U-Line factory authorized service near you, contact U-Line:
8900 N. 55
th
Street, Milwaukee, WI 53223 • u-line.com • onlineservice@u-line.com • +1.800.779.2547
Warranty 30379 Rev K 04.01.2017
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.