INTRODUCTION

Congratulations on your purchase of your U-Line drawer unit. A pioneer in the field for more than 40 years, U-Line is the world’s number one man­ufacturer of built-in, under-counter ice making and specialty refrigeration products. U-Line dedicates 100% of its research and development to these products. The result: U-Line technology leads the market with inno­vation, design, depth of product line and performance.
U-Line also backs customers with a strong dealer network. U-Line’s commitment to quality even extends to environmentally safe packaging. U-Line products are making life more convenient in homes, businesses, and hotels around the world.
PLEASE READ all instructions completely before attempting to install or operate the unit.
The icons 2075DWRR refrigerator unit, CO2075DWR
refrigerator/ice maker combination and 2075DWRWC Wine Captain
®
drawer units are used throughout this manual to help you identify the specifics to your U-Line product. Once you have your unit installed, we suggest you keep this manual in a safe place for future reference. Should any prob­lems occur, refer to the TROUBLESHOOTING section of this manual. This information will help you quickly identify a problem and get it remedied. In the event you require assistance, please contact the dealer where you purchased your unit.
1
PLEASE RECORD YOUR MODEL’S INFORMATION
Whenever you call to request information or service, you will need to know your model number and serial number. You can find this informa­tion on the serial plate located on the inside wall of your unit and on the product registration card.
PRODUCT REGISTRATION CARD
The package containing this manual also includes your product registra­tion information. Warranty coverage begins at the time your unit was purchased.
NOTE
Complete and mail the Product Registration Card as soon as possible to validate the registration date. You may also reg­ister the product online at www.U-LineService.com.
If you do not return your Product Registration Card, U-Line will use the date of sale to the U-Line distributor as the first date of warranty for your unit. Please also record the purchase date of your U­Line unit and your dealer’s name, address and telephone number.
Model Number: ______________________________________ Serial Number: ______________________________________ Purchase Date: ______________________________________ Dealer Name: ______________________________________ Dealer Address: ______________________________________ Dealer Telephone: ______________________________________
Keep this manual and the sales receipt together in a safe place for further reference.
User’s Manual
2
TABLE OF CONTENTS
INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
SAFETY PRECAUTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
LEVELING THE UNIT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
CONNECTING THE WATER SUPPLY . . . . . . . . . . . . . . . . . . . . . .11
BUILT-IN INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
CUSTOM DRAWER PANELS . . . . . . . . . . . . . . . . . . . . . . . . . .14
INITIAL START-UP AND ADJUSTING THE
TEMPERATURE CONTROL . . . . . . . . . . . . . . . . . . . . . . . . . . . .22
TEMPERATURE CONTROLLER . . . . . . . . . . . . . . . . . . . . .23
TEMPERATURE CONTROLLER . . . . . . . . . . . . . . . . . . . . .24
TEMPERATURE CONTROLLER . . . . . . . . . . . . . . . . . . . . .26
OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30
ICE MAKER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .36
CLEANING & MAINTENANCE . . . . . . . . . . . . . . . . . . . . . . . . . .38
STAINLESS STEEL MODELS . . . . . . . . . . . . . . . . . . . . . . . . .38
STORAGE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .41
TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .42
TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . .43
TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . .44
TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . .45
IF SERVICE IS REQUIRED . . . . . . . . . . . . . . . . . . . . . . . . . . . . .46
REPLACEMENT PARTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .46
3
User’s Manual

SAFETY PRECAUTIONS

Do not attempt to install or operate your unit until you have read the safe­ty precautions in this manual. Safety items throughout this manual are labeled with a Danger, Warning or Caution based on the risk type.
DEFINITIONS
This is the safety alert symbol. It is used to alert you to poten­tial personal injury hazards. Obey all safety messages that fol­low this symbol to avoid possible injury or death.
DANGER indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury.
WARNING indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury.
CAUTION indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury.
CAUTION
CAUTION used without the safety alert symbol indicates a potentially hazardous situation which, if not avoided, may result in property damage.
Indicates installation, operation or mainenance information which is important but not hazard related.
!
WARNING
DANGER
! !
!
4
CAUTION
!
GENERAL PRECAUTIONS
RISK OF CHILD ENTRAPMENT. Before you throw away your old refrigerator or freezer, take off the doors and leave shelves in place so that children may not easily climb inside.
• Never attempt to repair or perform maintenance on the unit until the electricity has been disconnected.
•Altering, cutting of power cord, removal of power cord, removal of power plug, or direct wiring can cause serious injury, fire and/or loss of property and/or life and will void the warranty.
• The anti-tip kit must be installed on this unit before it is used. Never use the drawers as steps or a shelf to sup­port more than the drawers’ content.
CAUTION
•Do not lift unit by drawer’s handle.
•Use care when moving the unit. Some edges are sharp and may cause personal injury. Wear gloves when moving or repositioning the unit.
• Allow unit temperature to stabilize for 24 hours before use.
• Failure to clean the condenser every three months can cause the unit to malfunction. This could void the warranty.
• Never install the unit behind closed doors. Be sure front grille is free of obstruction. Obstructing free air flow can cause the unit to malfunction, and may void the warranty.
CAUTION
•Use only genuine U-Line replacement parts. Imitation parts can damage the unit, and may void the warranty.
!
WARNING
DANGER
! !
5
User’s Manual

INSTALLATION

SITE PREPARATION
Your U-Line drawer unit must be installed under a counter or in a wall. These units are designed so they can be installed next to a wall. The
crisper in the and the caddy in the can be accessed from either side.
1. Position the unit on a flat, level surface, capable of supporting the entire weight of the unit. Remember the unit will be significantly heavier once it is fully loaded.
2. This unit requires grounded and polarized 115 VAC, 60Hz, 15A cir­cuit (normal household current).
ELECTROCUTION HAZARD! Electrical Grounding Required. This appliance
is equipped with a three prong (grounding) polarized plug for your protection against pos­sible shock hazards.
• NEVER remove the round grounding prong from the plug.
•NEVER use a two-prong grounding adapter.
•NEVER use an extension cord to connect power to the
unit.
Where a two-prong wall receptacle is encountered or a longer power cord is required, contact a qualified electrician to have it replaced in accordance with applicable electrical codes.
DANGER
! !
66
Your U-Line Drawer unit is designed so it can be installed next to the wall on either side (Figures 1, 2).
Figure 1 – Right wall installation
The anti-tip kit must be installed on this unit before it is used. Never use the drawers as steps or a shelf to support more than the drawers’ content.
3. These units must be installed in a wall or under a counter top to allow for the installation of the anti-tip kit. The drawer unit can be installed with an appliance or fixture located in front of it, as long as there is adequate clearance for the drawer to be opened and removed when servicing (Figure 3).
U-Line recommends you consider additional clearance in front of the open drawer for convenience.
!
WARNING
7
DWR001A
8
User’s Manual
Figure 2 – Left wall installation
Figure 3 – Front Clearance
CABIN
ET
R WA
LL
O
DWR002A
DWR003A
5. Position the unit to allow free air flow through the front grille (Figure 4).
Figure 4
6. Wipe inside of unit and all inside drawer components with a clean, water dampened cloth only.

LEVELING THE UNIT

It is important that the unit is level. All Échelon™ Series units are equipped with adjustable feet for leveling and height adjustment (Figure 5).
To level the unit:
1. Adjust all four leveling feet evenly so that the top of the cabinet is at the desired installation height.
2. Using a level of at least two feet in length, measure the level of the floor where the unit is to be installed. Measure back-to-front and side-to-side and note the measurements.
3. With the unit on a level surface, adjust the feet, as appropriate, to compensate for the floor level measurements noted in Step 2.
OFF
ON
DWR004
INTAKE
EXHAUST
9
10
User’s Manual
4. Place the unit in position where it is to be installed. Re-check cabi­net height and levelness (Figure 6) and adjust if necessary.
Figure 5
Figure 6
5. - Gently push unit into position to prepare for built-in installation.
10
RAISE
LEVEL TWO PLACES
LOWER
DWR005
DWR021
11

CONNECTING THE WATER SUPPLY

Install a 1/4 inch outside diameter copper water line (not supplied with unit) from the nearest COLD water pipe. When connecting the water supply, follow these guidelines:
• Review the local plumbing codes before you install the unit.
• In most instances, the cold water supply will come from the base­ment through a hole in the floor.
• The water pressure should be between 15 and 150 psi.
• Install a shut-off valve in the 1/4 inch outside diameter supply line (not supplied with unit).
• Connect sufficient tubing to the unit to allow the unit to be moved for cleaning and servicing. However, make certain that the tubing is not pinched or damaged during installation.
• U-Line recommends the use of copper tubing for installation.
1. Locate the compression fitting and ferrule packed in the unit. Slide the compression fitting and ferrule over the 1/4 inch outside diameter water supply line. Do not use thread seal- ing compound or tape. Using two wrenches, tighten the compression fitting on the supply line (see Figure 7). Do
not overtighten.
Figure 7
2. Carefully bend the water supply line into position and connect the line to the solenoid valve (see Figure 8). Avoid kinking the water supply line.
Figure 8
UL134_CO
WATER
CONNECTION
UL103_CO
12
User’s Manual
12
3. For recessed installations, allow extra water supply line length to provide slack for easy removal from the recessed area (see Figure 9). This will also safeguard against kinking the line.
Figure 9
CAUTION
If you are not intending to use the ice maker and do not con­nect the water supply (or turn the supply valve off), it is imperative to raise the bucket arm of the ice maker (see Figure 10). Failure to raise the bucket arm may result in damage to the water valve.
Figure 10
NOTE
After completing the installation, turn on the water and recheck water connection for leaks. Apply additional tighten­ing if needed. Do not use thread sealing compound or tape.
4. Plug in the power cord.
5. Gently push the unit into position to prepare for built-in installation.
UL002A_CO
DWR033
13

BUILT-IN INSTALLATION

Your U-Line product is designed for built-in installation only. When built-in, it does not require additional air space for the top, sides, or rear. However, the front grille must NOT be obstructed.
NOTE
Required for ease of installation and door opening, you must
allow an additional 1/4" to width of unit.
Unit Dimensions
* For full overlay drawer panels, add 3/4".
NOTE
The additional depth required for full overlay drawer panels only
applies to the and . The is not designed to accept full overlay drawer panels.
Once the unit is leveled and placed into the wall or under a cabinet, it is ready to be secured to the wall or cabinet with the anti-tip system (Figure 11).
Follow the instructions included with the anti-tip kit.
The anti-tip kit must be installed on this unit before it is used. Never use the drawers as steps or a shelf to support more than the drawers’ content.
!
WARNING
Width Height Depth*
23-15/16" 34-1/8" 24"
14
User’s Manual
Figure 11

CUSTOM DRAWER PANELS

NOTE
The is not designed to accept custom drawer panels.
Two types of custom drawer panels can be installed on your U-Line unit to harmonize with or accent the surrounding decor.
FULL OVERLAY DRAWER PANEL
Full overlay drawer panels completely cover the drawer frames and han­dle to give a built-in appearance. See Table 1 for full overlay drawer panel dimensions (Figure 15, see page 15).
Table 1. Full Overlay Panel Dimensions
A
1
B
2
C
1
Top panel with 1/2" gap
11-13/16" 14-3/4" 1"
between drawers
All bottom panels 11-13/16" 14-3/4" 1"
1
Screw hole location
2
Overall panel height
B
A
C
COUNTER TOP
C
OR WALL HEADER
ATK001a
15
OVERLAY PANEL KIT PARTS
• The total weight of both drawer panels must not weigh more than 20 lbs.
• The thickness of the drawer panel must be 3/4".
Remove existing drawer front from cabinet:
1. Open drawer. Pull door gasket (Figure 12) out of the groove (top edge of door only). Start in the mid­dle and pull outward, moving toward the edge. This may take some force.
2. Remove the two screws located on both sides of the lower handle. Remove the handle (Figure 13).
3. Slide the existing drawer panel and cardboard spacer out of the drawer frame. Discard the spacer.
Attaching the full overlay panel:
4. If required, attach optional cabinet handle hardware to the overlay panel at this time. If an optional cabinet handle is installed, make sure the mounting screw heads are counter­sunk.
Part Number Description Quantity
42120 Spacer Nylon 3/8 OD x .19 ID 10 42121 Screw #10 x 5/8 Round Head 10
1
Figure 13
Figure 12
HANDLE
SCREW
GASKET
DWR_OL_00
DWR_OL_002