Contents
Exterior Cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Cut-Out Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Product Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Door Swing/Clearances Information . . . . . . . . . . . . . . 5
Reversing the Door. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Other Site Requirements . . . . . . . . . . . . . . . . . . . . . . . . 6
Side-By-Side Installation Instructions . . . . . . . . . . . . . . 7
Custom 1/4'' Door Panel Insert . . . . . . . . . . . . . . . . . . . 7
Full Overlay Door Panel . . . . . . . . . . . . . . . . . . . . . . . . . 8
Checking Door Alignment . . . . . . . . . . . . . . . . . . . . . . 12
Adjusting Door Alignment . . . . . . . . . . . . . . . . . . . . . . 12
Drain Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Water Supply Connection . . . . . . . . . . . . . . . . . . . . . . . 15
Electrical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . 16
Leveling Information . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Installation Tip . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Installation of the CLRCO2175 . . . . . . . . . . . . . . . . . . . 18
Relocating the Shelves . . . . . . . . . . . . . . . . . . . . . . . . . 18
Installation Troubleshooting . . . . . . . . . . . . . . . . . . . . . 18
Initial Start-Up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Start-Up Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . 20
Service Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
1 Follow Safety Precautions
IMPORTANT
PLEASE READ all instructions completely before attempting to install or operate the unit.
• This unit requires connection to the water supply. Improper hook-up can result in substantial property damage! If you are unsure of your ability to safely connect the water supply to the unit, consult a licensed plumber for assistance.
• This unit requires connection to a drain. Improper connection can result in substantial property damage! If you are unsure of your ability to safely connect the unit to a drain, consult a licensed plumber for assistance.
• This unit requires connection to a grounded (three­prong), polarized receptacle that has been placed by a qualified electrician in accordance with applicable electrical codes.
Safety Alert Definitions
Safety items throughout this guide are labeled with a Danger, Warning or Caution based on the risk type:
DANGER
Danger means that failure to follow this safety statement will result in severe personal injury or death.
WARNING
Warning means that failure to follow this safety statement could result in serious personal injury, or death.
CAUTION
Caution means that failure to follow this safety statement may result in minor or moderate personal injury, property or equipment damage.
www.U-LineService.com 2 08/2006
Page 3
CLRCO2175 Combo®— Clear Ice Maker/Refrigerator
General Precautions
Use this appliance for its intended purpose only and follow these general precautions along with those listed throughout this guide:
WARNING
SHOCK HAZARD — Electrical Grounding Required.
• Keep the unit unplugged throughout installation except during testing.
• Never remove the round grounding prong from the plug and never use a two-prong grounding adapter.
• Never use an extension cord to connect power to the unit.
• Always keep your working area dry.
CAUTION
• Use care when moving and handling the unit. Use gloves to prevent personal injury from sharp edges.
• Do not lift the unit by the door or door handle.
• Do not install the unit behind closed doors or in any way that would obstruct airflow to the front grille, which may cause the unit to malfunction.
2 Inspect and Plan
You have received a carton containing your CLRCO2175 Clear Ice Maker/Refrigerator with a package inside containing a Use and Care Guide, a Product Registration Card and water connection parts. Complete and mail the Product Registration Card or register online at www.U-LineService.com. Once your unit is installed, keep the Use and Care Guide and this Installation Guide in a safe place for future reference.
Your unit is Black, White or Stainless Steel. Black and White units have a reversible door with a slightly contoured handle across the top. They come with a flush mounted door panel that, when removed, will accept a custom 1/4-inch thick door panel or a 3/4-inch thick full overlay door panel. Stainless Steel units are covered with a protective coating and have been ordered left- or right­hand hinged. The Stainless doors are not reversible and do not accept custom panels. CLRCO2175 Clear Ice Maker/ Refrigerators may be ordered with or without a factory­installed drain pump. Please carefully follow the directions that apply to your unit and your intended design.
Tools/Materials Required
• Screwdrivers — slotted and Phillips head
• 1/4-inch OD copper tubing and shut-off valve for water supply line
• 5/8-inch ID drain line
• P60 Drain Pump (if required and not already factory installed, see Page 13)
• 1/4-inch thick door panel material and cutting tools (Black or White units) (If installing a 1/4”Panel)
• Full Overlay Door Panel Kit (part number U-OL2175B — Black or part number U-OL2175W — White), 3/4-inch door panel overlay, cutting tools, drill and bits (Black or White units) (If installing a 3/4” Full Overlay)
08/2006 3 www.U-LineService.com
Inspection
Unwrap and inspect the unit on a flat, level surface capable of supporting its entire weight.
Removing Protective Coating
(Stainless Steel Units Only)
When inspecting/installing a Stainless Steel unit, the protective coating covering the unit must be removed first. Start at a corner of the unit/door and pull back the protective coating to remove it from the unit/door.
Page 4
CLRCO2175 Combo®— Clear Ice Maker/Refrigerator
After all the protective coating has been removed from the unit/door, clean all Stainless Steel surfaces with Claire Stainless Steel Polish and Cleaner or comparable product or a mild detergent and warm water solution and soft cloth. Do NOT use abrasive cleaning agents.
Note: If cleaning with mild detergent and warm water solution and soft cloth, the unit MUST be treated with Claire Stainless Steel Polish and Cleaner or comparable product to prevent discoloration.
Exterior Cleaning
(As Required)
Black and White Models:
• The door, grille and cabinet may be cleaned with a mild detergent and warm water solution. Do not use solvent-based or abrasive cleaners. Use a soft sponge and rinse with clean water. Wipe with a soft, clean towel to prevent water spotting.
Stainless Steel Models:
• Stainless steel models can discolor when exposed to chlorine gas, pool chemicals, salt water or cleaners with bleach.
• Keep your stainless steel unit looking new by cleaning with a good quality all-in-one stainless steel cleaner/ polish on a monthly basis. For best results use Claire Stainless Steel Polish and Cleaner, which can be purchased from U-Line Corporation. (The part number is 173348.) Comparable products are acceptable. Frequent cleaning will remove surface contamination that could lead to rust. Some installations may require cleaning on a weekly basis.
• Do not clean with steel wool pads.
• Do not use cleaners that are not specifically intended for stainless steel (this includes glass, tile and counter cleaners).
• If any surface discolors or rusting appears, clean it quickly with Bon-Ami or Barkeepers Friend Cleanser and a non-abrasive cloth. Always clean in the direction of the grain. Always finish this process with Claire Stainless Steel Polish and Cleaner or comparable product to prevent further problems.
• Use of abrasive pads such as Scotchbrite will cause the graining in the stainless to become blurred.
• Rust that is allowed to linger can penetrate into the surface of the stainless steel and complete removal of the rust may not be possible.
3 Prepare Site
Your U-Line product has been designed for either free­standing or built-in installation. When built-in, your unit does not require additional air space for top, sides or rear. However, the front grille must NOT be obstructed and clearance is required for water, drain and electrical connections in the rear.
Note: Unit can NOT be installed behind a closed cabinet door.
Cut-Out Dimensions
See Electrical
Specifications
34-1/4"
to
35-1/8"
8"
for Power Supply
24-3/16"
Figure 1
Follow the cut-out drawing in Figure 1. The 24-3/16" width allows 1/4" for ease in installation and removal of the unit. The 24" depth is the cabinet depth in most installations. The unit is 24" deep including the handle on Black and White models and 24" deep including the door and not the handle on Stainless Steel models (see
Figure 2).
IMPORTANT
If you would like to align the face of the unit with other adjacent cabinet doors in certain installations, you may need to alter the wall just behind the drain connection on the unit to accommodate the drain. The actual amount of alteration will be determined by your actual drain connection components.
24"
www.U-LineService.com 4 08/2006
Page 5
CLRCO2175 Combo®— Clear Ice Maker/Refrigerator
Product Dimensions
24"
Including
Handle
34-1/8"
23-15/16"
Black and White Stainless Steel
Figure 2
Please note that the unit has adjustable feet that can add one additional inch to height during leveling or to match adjacent cabinets (see Figure 44 on Page 17).
26-1/8"
Including
Handle
34-1/8"
23-15/16"
Door Swing/Clearances Information
Black and White units have a zero clearance for the door to open 90° (see Figure 3). Stainless Steel models require a minimum of 2-1/8" door clearance to accommodate the handle if the unit is installed next to a wall or similar type of structure.
Reversing the Door
(Black and White Units Only)
All U-Line units (except Stainless Steel models) may be left- or right-hand opening. The door opening is easily reversed by moving the hinge hardware to the opposite side. The top hinge hardware will be used on the bottom of the other side and the bottom hinge hardware will be used on the top of the other side (see Figure 4).
To reverse the door:
Remove top hinge screw
1. pin from door (Phillips screwdriver) (see
).
Remove
5
Figure
door by tilting
forward and lifting off bottom hinge pin.
Remove plastic screw plugs (3 each, top and bottom)
2. from new hinge location. Do not discard (see
Figure 4
Figure 6
ULIN_0015_A
).
90°
Door Swing
Figure 3
Wall Wall
1/4" Min.
21-3/4"
25-1/2"
90°
Door Swing
Black and White
2-1/8" Min.
Stainless Steel
21-3/4"
25-1/2"
Screw Plugs
Figure 6
Figure 5
ULIN_0133_A
3. Remove top hinge (3 screws), reinstall hinge screw pin, and remount on opposite side BOTTOM (see
Figure 7
).
08/2006 5 www.U-LineService.com
Page 6
CLRCO2175 Combo®— Clear Ice Maker/Refrigerator
4. Remove the two door closer inserts from the existing bottom hinge and install as shown on the new bottom hinge (see
1
Figure 7
Figure 8
2
).
ULIN_0003_A
Door
Closer
Inserts
Figure 8
5. Remove existing bottom hinge (3 screws) and remount on opposite side TOP. Remove hinge screw pin.
6. Remove the plastic hole plug from the top of the door to allow the pivot pin to be inserted in the new location. Install the plug into the vacated hole on the opposite side.
7. With bottom of door facing up, remove pivot plate (2 screws), flip over, and remount on opposite side of door (see
Figure 9
). Be sure notch in plate faces center.
Figure 9
8. Holding door upright with top of door tilted forward, place hole of door pivot plate on bottom hinge screw pin (see
Figure 10
).
9. Tilt top of door into position in top hinge and install top hinge screw pin.
Other Site Requirements
Power Supply
The unit requires a grounded and polarized 115 VAC, 60 Hz, 15A circuit (normal household current). See Electrical Specifications on Page 16.
Water Supply
The unit requires a 1/4-inch OD water supply line and a shut-off valve. For more information see Page 15.
Drain
The unit’s generous 7-inch drain connection height extends the distance the unit can be located from a gravity drain. For more information see Page 13.
IMPORTANT
Drain can NOT be located directly below unit. Unit has a solid base that will not allow unit to drain below itself.
Environmental Requirements
Many U-Line models are designed to operate in harsh outdoor/marine environments. Special considerations include the following:
• The units are designed to operate between 50°F (10°C) and 110°F (40°C). High ambient temperatures (110°F [40°C] or higher) may reduce the unit’s ability to reach low temperatures and may also reduce the ice production rate for those models with icemakers.
• If the ambient temperature is expected to drop below 45°F (7°C), drain all water from the unit to prevent freezing damage not covered by the warranty.
• For best performance, keep the unit out of direct sunlight and away from heat generating equipment.
• For best performance and life outdoors, place under a counter or provide shelter of some kind.
• In climates where high humidity and dew points are present, condensation may appear on outside surfaces. This is considered normal. The condensation will disappear when the humidity drops.
10. Install plastic screw plugs removed in Step 2 in old hinge holes (3 each, top and bottom).
Figure 10
www.U-LineService.com 6 08/2006
Page 7
CLRCO2175 Combo®— Clear Ice Maker/Refrigerator
Side-By-Side Installation Instructions
For a complete refreshment center, install your CLRCO2175 Clear Ice Maker/Refrigerator beside a U-Line Drawer or Wine Captain Model (see Figure 11 for typical cut-out). Note that each Side-By-Side Installation will be different.
• Cut-out width for a side-by-side installation is the total
of the widths listed under Cut-Out Dimensions in each unit’s Installation Guide.
For example:
Placing a CLRCO2175 Clear Ice Maker/Refrigerator next to a 2115 series unit would require a cut-out width of: 24-3/16" + 15-3/16" = 39-3/8"
Placing a CLRCO2175 Clear Ice Maker/Refrigerator next to a 2175 series unit would require a cut-out width of: 24-3/16" + 24-3/16" = 48-3/8"
No trim kit is required. However, 1/4-inch space needs to
be maintained unobstructed door swing.
• Units must operate from separate, properly grounded
electrical receptacles placed according to each unit’s Electrical Specifications.
between the units to ensure
4 Prepare and Install Door Panel
(Black and White Units Only)
Two types of custom door panels can be installed on your Black or White unit to harmonize with or accent the surrounding décor: a Custom 1/4" Insert or a Full Overlay. If no custom door panel is used, go on to 5 Adjust Door.
Custom 1/4'' Door Panel Insert
Door Panel Preparation
A custom door panel can be inserted into the doorframe. Custom door panels can be flat or raised, as long as the maximum panel thickness where inserted into the door reveal (channel) is 1/4"-thick. For raised panels, the depth of the reveal is 1/4" on all four sides.
IMPORTANT
Raised panels will reduce the door’s 90° swing/zero clearance if the unit is installed next to a wall or similar type of structure.
For 2175 models cut the panel insert to the following dimensions.
Custom 1/4" Dimensions:
Typical Side-By-Side Cut-Out
34-1/4"
to
35-1/8"
24"
1/4" Space
Between
Appliances
Figure 11
Width: 23-1/32" Height: 27-11/16"
For 2115 & CLR2160 models cut the panel insert to the following dimensions.
Acceptable
Location
7"
Preferred Location for CLRCO2175
Receptacle
Custom 1/4" Dimensions:
Width: 14-1/32" Height: 27-11/16"
The door panel must not weigh more than 20 lbs.
1-1/2"
Door Panel Installation
Install the insert as follows:
CAUTION
Use care when handling the insert. Insert edges may be sharp.
1. Remove top hinge screw pin (using a Phillips screwdriver, see Figure 12). Remove door by tilting forward and lifting off bottom hinge pin.
08/2006 7 www.U-LineService.com
Page 8
CLRCO2175 Combo®— Clear Ice Maker/Refrigerator
A
ULIN_0133a_
Figure 12 Figure 13
2. Pull door gasket out of groove (top edge of door only). Start in the middle and pull outward, moving toward the edge (see
Figure 13
). This may take some force.
3. Remove two outside screws holding door handle. Slightly separate door handle from door (see
Figure 14
).
4. Pull handle up and off.
5. Remove and discard existing panel and cardboard spacer.
6. Slide custom door panel insert into 1/4-inch channel in door front.
7. Holding door gasket out of the way, replace handle
Figure 14
on door, making sure it is seated properly on insert and that screw holes line up.
8. Install two small screws removed in Step 3.
9. Starting at the corners and working inward, push door gasket into place on door.
Full Overlay Door Panel
Door Panel Preparation
A full overlay door panel completely covers the doorframe and handle to give a built-in appearance. See your U-Line dealer for the optional Full Overlay Door Panel Kit.
2175 Models:
P/N U-OL2175B -- Black P/N U-OL2175W -- White
2115 & CLR2160 Models:
P/N U-OL2115B -- Black P/N U-OL2115W --White
Appropriate hardware, Modified Handle, Replacement Hinges and a copy of these instructions will be included in the kit.
1. Cut the overlay to the following dimensions (see Figure 15).
Full Overlay Dimensions:
2175 Models: 2115 & CLR2160 Models:
Width: 23-3/4" Width: 14-3/4" Height: 29-3/4" Height: 29-3/4"
The door panel must not weigh more than 20 lbs.
31/32"
Relief Notch
for Pivot Plate
3/4"
1/8"
10. Place door on bottom hinge pin and install upper hinge screw.
www.U-LineService.com 8 08/2006
Figure 15
Rear View
of
Wood Panel
Width
ULIN_0400_A
Height
IMPORTANT
Rear View of wood panel for right-hand hinge shown. Use mirror image for left-hand hinges.
Page 9
CLRCO2175 Combo®— Clear Ice Maker/Refrigerator
2. Create a relief (
Figure 15
) for pivot plate by cutting
notch in top corner of overlay panel. Refer to
16
for exact specifications.
15/32"
ø 0.177" (#16 Drill)
11/16" Deep
3/8"
31/32"
Ref
3/4" Min Ref
.125"
11/16"
1/4" Ref
3/8"
SIDE VIEW
13/32"
Figure 16
Figure
TOP VIEW
BACK VIEW
BOTTOM VIEW
x
ø 5/16"
1/4" Deep
Chamfer 1/32" x 45°
ULIN_0401_A
Installation Instructions
Removing Existing Door
1. Remove the door shelves by first pulling shelves up at a 45° angle, then straight out.
2. Remove top hinge screw pin (Phillips screwdriver). Remove the door by tilting forward and lifting off the bottom hinge pin.
3. Pull door gasket out of the groove (top edge of door only). Start in the middle and pull outward, moving toward the edge (see
Figure 17
force.
Figure 17 Figure 18
). This may take some
Old Handle
New Handle
ULIN_0403_A
Route notch in top corner of overlay panel as shown (see Top and Side Views). Top of notch is entire depth of panel, front to back.
Width: 31/32"
Depth: 1/8"
CAUTION
Be careful not to drill too deep! Drilling holes too deep may destroy your door panel.
3. Drill hole for upper door hinge (top of panel) (see
Figure 16
, Top View).
0.177" diameter (#16 drill) x 11/16" deep
4. Drill hole for lower door hinge (see
Figure 16
, Bottom
View).
5/16" diameter x 1/4" deep
CAUTION
It is important to ensure that all drilled holes are drilled to the correct depth in order to avoid splits in the wood when hardware is installed.
4. Remove the two screws located on both sides of the handle.
5. Remove the handle and discard. (This handle will be replaced with the Overlay Handle included in the Full Overlay Door Panel Kit.)
6. Slide the existing door panel out of the doorframe.
Attaching the Full Overlay Panel
1. Place and tape the existing door panel on the back of the overlay panel (see Figure 19) and drill holes through both panels according to Figure 20. Remove tape adjoining the panels and enlarge the six holes in the steel (black/white vinyl color) panel using a 0.201" (#7) drill.
2. If a user-supplied cabinet handle will be used, attach its hardware to the overlay panel at this time.
08/2006 9 www.U-LineService.com
Page 10
CLRCO2175 Combo®— Clear Ice Maker/Refrigerator
Back of
Wood Panel
1-3/4" Top
Wood Panel
Figure 19
Tape
Top of
Drill ø 5/32" x 3/8" Deep
6 places Model 2115 and CLR2160
7 Places Model 2175
For use with #10 x 5/8"
Wood Screw and Nylon Spacer
3/8"
Both Sides
2-5/8"±1/4"
15-9/16"±1/4"
Removed
Door Panel
Side of
Wood Panel
Typical
Wood Panel
Figure 21
Door Panel
Plastic Spacer
Seven Required
#10 x 5/8"
Round Head Screw
Seven Required
4. Remove the existing bottom pivot plate and replace with the Full Overlay pivot plate (see
Existing
Door
Existing Bottom Pivot Plate
(Remove and Discard)
Figure 22
Wood Panel Bottom Pivot Plate
(5/8" Longer Than
Existing Bottom Pivot Plate,
Flush Side Facing Out)
#8-32 x 3/8" SEMS Hex Screw
Two Places
).
±
28-7/8"
1/4"
1"
11-7/8±1/32
For use on
Model 2175 Only
1"
ULIN_0402_A
Figure 20
3. Attach the door panel to the overlay panel using #10 x 5/8" wood screws and nylon spacers. The nylon spacers fit between the overlay panel and the door panel as shown in
Figure 21
door panel to slide back into the
. The spacers
allow the original
1/4"-thick door
reveal (channel).
Figure 22
IMPORTANT
Door panel and overlay panel must be aligned properly or the door will not operate correctly.
Assembling the Door
1. Install the assembled panel by sliding the original door panel back into the doorframe.
2. Replace the Overlay Handle and secure with the two screws removed in Step 4 under Removing Existing Door.
3. Attach Overlay cap to door, opposite side of where hinges will be (see
3/4" Wood Panel
Figure 23
).
Overlay Cap
Replacement Handle
www.U-LineService.com 10 08/2006
Figure 23
Page 11
CLRCO2175 Combo®— Clear Ice Maker/Refrigerator
4. Attach Top Pivot Plate to door handle, on side where hinges will be. Use the two #8-32 x 1/2" Flat Head Phillips screws (Black) supplied with kit (see
#8-32 x 1/2" Flat Head Screws
Black, Two Places
Figure 24
).
3/4" Wood Overlay
Top Pivot Plate
Screw to attach Handle
Removed in step 4
Figure 24
5. Starting at the corners and working toward the center, push the door gasket back into place.
Installing the Door
1. Remove the existing hinges from the unit, saving the door closure assembly.
2. Install the new Replacement Top Hinge onto the unit (see
Figure 25
Wood Panel Top Hinge Plate
(5/8" Longer than Existing Top Hinge Plate)
).
Pivot Post
Door Closure Top
Door Closure
Bottom
Boss
Pivot Post
Boss
Existing Door
#8-32 x 1/2" Flat Head Screw
Three Places
Wood Panel Bottom Hinge Plate
(5/8" Longer than Existing Bottom Hinge Plate)
Figure 26
IMPORTANT
Pivot posts must be cleaned. Closers must also be clean and greased to ensure proper operation.
5. Place the modified door onto the pivot post.
6. Position door and install the pivot post into the top hinge (using the Phillips screwdriver).
7. Adjust door as needed for proper closure.
8. Check to see that light goes off when the door closes.
9. Reinstall the door shelves by lining up the bosses and first pushing straight in, then down at a 45° angle.
#8-32x 1/2"
Flat Head Screw
Three Places
Top Pivot Plate
Figure 25
Door Panel
ULIN_0405
3. Install the pivot post into the new Replacement Bottom Hinge (using the Phillips screwdriver) and install the hinge onto the unit.
4. Replace the door closure assembly onto the bottom pivot post (see
Figure 26
). Be sure that bosses on
closers align with holes in hinge and hinge plate.
08/2006 11 www.U-LineService.com
Page 12
CLRCO2175 Combo®— Clear Ice Maker/Refrigerator
5 Adjust Door
Checking Door Alignment
The unit’s door is aligned at the factory before shipment. However, its alignment could have been disturbed during shipment or during door panel installation.
IMPORTANT
Properly aligned, the door should be 1/8" below the top of the unit’s cabinet, NOT flush with the top (see
1/8"
Figure 27
).
Figure 27
1. Compare the top edge of the door to the top edge of the cabinet.
2. If the door edge is 1/8" below and parallel to the top of the cabinet, go on to
6 Prepare Plumbing
. If it is not, note whether the side opposite the hinge needs to be moved UP or DOWN, and use the following procedure.
Note: If door is adjusted correctly, but panel is not square with the adjacent cabinets, slight adjustments can be made by drilling the holes in the vinyl coated steel panel slightly oversized. See Figure 21 on Page 10.
Adjusting Door Alignment
1. Remove top hinge screw pin (Phillips screwdriver, see Figure 28). Remove door by tilting forward and lifting off bottom hinge pin.
2. With door upside-down, loosen but do not remove the two screws on the door’s bottom hinge plate.
Slotted
Mounting
Holes
Outside
Door Edge
Raise
Lower
Outside
Door Edge
Notch
Figure 29
3. See
Figure 29
. If the top far edge of the door needs to move UP, move the hinge plate toward the outside of the door and retighten screws. If the top far edge of the door needs to move DOWN, move the hinge plate toward the inside of the door and retighten screws.
4. Mount the door to recheck alignment and repeat Steps 2 and 3 if further adjustment is necessary.
5. When top edge of door is parallel to top edge of cabinet, remove the door and ensure the two screws are secure.
6. Remove the door closers from the bottom hinge, clean thoroughly and lubricate the mating surfaces with petroleum jelly.
7. Reinstall the closers, lining up the bosses with holes in hinge and hinge plate (see
Figure 30
8. Mount the door, install top hinge pivot pin and go on
6 Prepare Plumbing
to
).
Door
Closer
Inserts
.
Boss
Figure 30
Figure 28
www.U-LineService.com 12 08/2006
ULIN_0133_A
Page 13
CLRCO2175 Combo®— Clear Ice Maker/Refrigerator
6 Prepare Plumbing
CAUTION
Plumbing installation must observe all state and local codes. All water and drain connections MUST BE made by a licensed/qualified plumbing contractor. Failure to follow recommendations and instructions may result in damage and/or harm.
Drain Connection
IMPORTANT
Drain can NOT be located directly below unit. Unit has a solid base that will not allow unit to drain below itself.
The CLRCO2175 can be installed using a Gravity Drain, a Factory-Installed Drain Pump (U-Line P60) or a Locally­Installed (U-Line P60) Drain Pump. Drain lines must have a 5/8-inch inside diameter. The floor drain must be large enough to accommodate drainage from all attached drains.
Follow these guidelines when installing drain lines to prevent water from flowing back into the ice maker storage bin and/or potentially flowing onto the floor, causing water damage:
Gravity Drain
Waste
Shut-Off
Valve
Cold
Water
Figure 32
Waste
Hot
Water
If using a Gravity Drain:
1. Attach the 5/8-inch ID drain connection on the back of the unit to a 5/8-inch OD rigid tube, using a worm clamp.
2. Attach the other end of the rigid tube to your 5/8-inch ID drain line with a worm clamp.
3. Insulate the drain line, if necessary to prevent condensation. Go on to Water Supply Connection.
Gravity Drain
A Gravity Drain may be used if:
• Drain line has at least a 1-inch drop per 48 inches of run (1/4 inch per foot).
• Drain line does not create traps or created traps are vented (see Figure 31).
Normal
Proper Drain
Poor Drainage, Water Will Back Up
Figure 31
See Figure 32 for a typical Gravity Drain installation.
With Trap
With Trap and Vent
Proper Drain
Factory-Installed Drain Pump
If your drain line will run up to a stand pipe, disposal assembly or spigot assembly or does not otherwise meet the requirements for a Gravity Drain, you may have ordered the CLRCO2175 with a U-Line P60 Drain Pump. See Figures 33, 34 and 35 for typical installations requiring a Drain Pump. If you need to install a P60 Drain Pump into your unit, see Locally-Installed Drain Pump on
Page 15.
Stand Pipe
Waste
Shut-Off
Valve
Cold
Water
Hot
Water
Figure 33
Waste
08/2006 13 www.U-LineService.com
Page 14
CLRCO2175 Combo®— Clear Ice Maker/Refrigerator
Disposal Assembly
Air Gap
(Optional Hook-Up)
Waste
Cold
Water
Hot
Water
Shut-Off
Valve
Figure 34
Spigot Assembly
Air Gap
(Optional Hook-Up)
Waste
Shut-Off
Valve
Cold
Water
Hot
Water
Figure 35
IMPORTANT
Before installing your U-Line CLRCO2175 with Factory­Installed U-Line P60 Pump, it is extremely important to check and test all hose connections at the drain pump. There is a possibility that hose connections may have loosened during shipment.
To check and test hose connections:
1. Make certain the unit is not plugged into an electrical outlet.
2. Carefully push the power cord grommet through the hole in the back panel (see
Screws
Grommet
Power
Cord
Figure 36
Drain
Fitting
).
Water
Connection
Back
Panel
Figure 36
3. Remove 12 screws and back panel.
WARNING
Back panel serves as a guard. DO NOT put your hands inside the ice maker cabinet or attempt to touch any components except the discharge tube during testing. Failure to follow this warning could result in serious personal injury or death.
4. Check that the clamps and hose connections are tight at the following areas (see
• Discharge tube (A)
• Drain tube (B)
• Vent tube (C)
Figure 37
):
WARNING
To prevent accidental electrocution, make certain that the floor surfaces surrounding the unit are dry whenever power is removed from, or applied to, the unit.
www.U-LineService.com 14 08/2006
Figure 37
C
C
A
Back View Side View
BB
Page 15
CLRCO2175 Combo®— Clear Ice Maker/Refrigerator
5. Place a suitable container beneath the pump’s discharge tube. (The bucket must be able to hold a minimum of one gallon.)
6. Plug the ice maker power cord into a properly grounded, polarized electrical outlet.
7. Verify pump operation by pouring one gallon of water into the ice storage bin of the ice maker. The pump should energize and pump the water into the container.
8. At this time, verify that all tube and clamp connections are tight and leak free.
9. Unplug unit power cord from electrical outlet.
10. Reinstall back panel.
To connect to drain:
1. Attach the 5/8-inch ID drain connection on the back of the unit to a 5/8-inch OD rigid tube, using a worm clamp.
2. Attach the other end of the rigid tube to your 5/8-inch ID drain line with a worm clamp.
3. Insulate the drain line, if necessary to prevent condensation. Go on to Water Supply Connection.
Locally-Installed Drain Pump
If a gravity drain connection is not possible, and you have not purchased the CLRCO2175 with factory-installed pump, we strongly recommend the use of the U-Line P60 drain pump. The U-Line P60 drain pump is available through your Dealer, or direct from U-Line with complete installation instructions. If a pump other than the U-Line P60 drain pump is to be used, it must meet the following specifications:
CAUTION
In the event of a power outage, restricted drain or pump failure, the failure to use the U-Line P60 drain pump or a pump with the above listed specifications, could result in substantial water leakage and pooling with severe and costly water damage and related consequential damages and harm.
Water Supply Connection
When connecting the water supply, follow these guidelines:
• Review the local plumbing codes before you install the unit.
• Connect to the cold water supply.
• The water pressure should be between 20 and 120 psi.
• Install a shut-off valve in the 1/4 inch Outside Diameter water supply line.
• Connect sufficient tubing to the unit so that tubing may be looped, allowing the unit to be removed for cleaning and servicing (see Figure 40). However, make certain that the tubing is not pinched or damaged during installation.
Note: U-Line recommends the use of copper tubing for installation. The use of other types of tubing is not
recommended due to potential aftertaste & deterioration over time.
To connect to water supply:
1. Install the 1/4 inch Outside Diameter copper water line
from the main water source (see Figure 38).
It must be UL listed and have a UL listed, 120 VAC,
• 3-wire grounded power cord.
It must have overall maximum outside dimensions of
• 8-3/4" wide x 5-3/4" deep x 7-3/4" high.
• It must have a minimum flow rate of 1.5 gallons per minute at 10 feet of lift.
• It must have a sealed sump which does not allow water leakage in the case of a power outage, restricted drain or pump failure.
• It must have a check valve in the discharge line to prevent waste water return to the pump.
• It must have an overflow protection control which will shut off power to the ice maker in the event of a pump failure.
• It must have an operating temperature range of 50°F to 110°F (10°C to 40°C).
Water
Connection
Figure 39Figure 38
2. Locate the compression fitting and ferrule packed with the unit. Slide the compression fitting and ferrule over the 1/4-inch Outside Diameter water supply line. Do not use thread sealing compound or tape. Using two wrenches, tighten the compression fitting on the supply line (see Figure 39).
08/2006 15 www.U-LineService.com
Page 16
CLRCO2175 Combo®— Clear Ice Maker/Refrigerator
3. Carefully bend the water supply line into position and connect the line to the solenoid valve (see
Figure 40
).
Avoid kinking the water supply line.
Figure 40
IMPORTANT
Normal operation creates some vibration. A water supply line contacting cabinet wall may cause excessive noise during operation or damage to the line.
4. For recessed installations, allow extra water supply line length to provide slack for easy removal from the recessed area (see against kinking the line.
5. Go on to
7 Prepare Power Supply
Figure 40
). This will also safeguard
.
7 Prepare Power Supply
Electrical Specifications
CAUTION
Electrical installation must observe all state and local codes. This unit requires connection to a grounded (three­prong), polarized receptacle that has been placed by a qualified electrician.
The unit requires a grounded and polarized 115 VAC, 60 Hz, 15A power supply (normal household current). An individual, properly grounded branch circuit or circuit breaker is recommended. GFCI (ground fault circuit interrupter) is usually not required for fixed location appliances and is not recommended for your unit because a GFCI could be prone to nuisance tripping. However, be sure to consult your local codes.
See Figure 41 for recommended receptacle location. Plugging the unit into a receptacle located behind an adjacent cabinet will allow the CLRCO2175 to be more easily serviced with self-diagnostics without disturbing your installation.
Preferred
Acceptable
Location
24"
Location
for CLRCO2175
Receptacle
7"
1-1/2"
Figure 41
WARNING
SHOCK HAZARD — Electrical Grounding Required.
• Never remove the round grounding prong from the plug and never use a two-prong grounding adapter.
• Never use an extension cord to connect power to the unit.
Go on to 8 Level the Unit.
www.U-LineService.com 16 08/2006
Page 17
CLRCO2175 Combo®— Clear Ice Maker/Refrigerator
8 Level the Unit
Leveling Information
IMPORTANT
It is extremely important that the unit is level. If it is not level, the ice mold will not fill evenly.
A unit that is not level can cause a reduction in ice rate, uneven sized cubes or water spilling into the storage area, which will cause the ice in the bin to melt prematurely (see Figure 42).
Remember that floors near drains have a tendency to slope towards the drain.
1. Use a level to check the levelness of the ice maker from front to back and from side to side. Level should be placed along top edge and side edge as shown (see Figure 43).
Figure 42
1
2. If the ice maker is not level, adjust the feet on the corners of the unit as necessary (see
Turn Foot to Adjust
Figure 44
3. Check the levelness after each adjustment and repeat the previous steps until the unit is level. Go on to
9 Install the Unit
.
Figure 44
).
Installation Tip
If the room floor is higher than the floor in the cut-out opening, adjust the rear feet to achieve a total unit rear height of 1/8" less than the opening’s rear height. Shorten the unit height in the front by adjusting the front feet. This allows the unit to be gently tipped into the opening. Readjust the front feet to level the unit after it is correctly positioned in the opening.
Figure 43
ULIN_0193_A
08/2006 17 www.U-LineService.com
Page 18
CLRCO2175 Combo®— Clear Ice Maker/Refrigerator
A
A
A
9 Install the Unit
Installation of the CLRCO2175
1. Open the water supply valve in the main water source.
2. Plug in the power cord.
3. Open the door and press the POWER icon (see
47, 1
) on the display until OFF is displayed..
Note: If the unit is NOT turned OFF, water will immediately start flowing into the unit when it is first plugged into the electrical outlet.
4. Gently push the unit into position. Be careful not to kink the drain or water supply line or entangle the electrical cord.
5. Re-check the leveling, from front to back and side to side. Make any necessary adjustments. The unit’s top surface should be approximately 1/8" below the countertop.
6. Test the drain system by pouring one gallon of water into the ice bin. The water should drain freely and there should be no leakage.
7. Remove the tape from the glass shelves and wipe out the inside of the unit with a clean, water-dampened cloth.
Figure
Relocating the Shelves
Both the glass shelves in the refrigerator and the inner door shelves can be moved to accommodate your bottles, cans and containers.
Glass Shelves on Right-Hand Hinge Units
Door Shelves
1. First pull shelf up at a 45° angle, then straight out (see Figure 46).
2. Choose new location and line up on bosses. First push straight in, then down at a 45° angle.
Figure 46
Notch
Boss
Installation Troubleshooting
Problem
:
Water is leaking under the unit.
Solution
:
A water leak under the unit is most likely caused by a bad connection in the water supply line. Make sure the water line’s brass fitting is screwed tight to its valve and threaded correctly. Make sure the fill tube’s connection to the water line is also tight. Check drain line to make sure it has not been disconnected from drain connection on back of the unit or disconnected from the drain.
Problem
:
The door remains open unless it is pushed closed.
1. Open door fully, grasp shelf firmly, lift front edge slightly, and pull straight out.
2. Choose new location and slide shelf onto the appropriate rib.
Glass Shelves on Left-Hand Hinge Units
1. See Figure 45. Pull shelf out about 6” to clear the wall’s molded protrusion.
2. Tilt right-hand edge of shelf up.
3. Keeping at this angle and hugging the right wall, pull the shelf out.
4. Choose new location and insert over ribs, tilting right-hand edge up. Push in, then lower shelf onto ribs.
www.U-LineService.com 18 08/2006
1. Pull Out 6"
3. Pull
2. Tilt
Figure 45
Solution
:
The hinges should be self-closing when the door is open
"
approximately 8 closers (at the bottom of the hinge pin) are clean, greased and installed correctly. Also, re-check leveling from front to back of the unit and readjust if necessary. Make sure that pivot plate is installed correctly.
Problem
:
The custom overlay door was designed to align with the rest of the cabinet doors, but the unit has crept forward.
Solution
:
First, make sure that the electrical cord and water supply line are not obstructing the installation. If they are not, there is mostly likely not enough room allowed for the drain connection on the rear of the unit. You may need to alter the wall behind the unit to accommodate the drain connection.
. If this is not the case, make sure the
Page 19
CLRCO2175 Combo®— Clear Ice Maker/Refrigerator
10 Start-Up for the First Time
Initial Start-Up
Once installation and leveling is complete, the unit is ready for initial start-up and operation. The Display panel is located inside the unit, on the top of the refrigerator side(see Figure 47, 1).
The LED display shows the temperature set point and is calibrated in degrees Fahrenheit. The controller is factory programmed for a set point of 38°F which will show when the unit is first powered up
123 54
Figure 47
1. Open the door and remove the cover in front of the evaporator by gently compressing and pulling forward. This will enable you to observe the water flow over the evaporator.
2. Check that the overflow tube is inserted securely into the water trough.
ULIN_0058_A
Other Settings
Other settings for the Clear Ice Maker side of the CLRCO2175 are factory preset. No adjustments should be necessary at this time. For information about Ice Cube Thickness, or additional settings, see the Use and Care Guide.
3. Press the POWER icon aproximately five seconds until the and release the water reservoir. The water fill valve shuts off after approximately 180 seconds (3 minutes). The compressor begins to operate.
4. Watch the water flow over the evaporator assembly (ice cube tray) to familiarize yourself with the operation. Upon initial start-up, water flow over the evaporator may be uneven. This may cause uneven sized cubes or water spilling into the ice storage bin. This is a normal situation and will correct itself within the first 24 hours of operation.
5. Replace the evaporator cover. Note that after the first slab of ice is produced, ice production will stop until the refrigerator side of the CLRCO2175 reaches the set point temperature. Then, ice production will begin again.
6. Allow unit to run for at least 24 hours to stabilize before making any temperature or ice adjustments.
. The water fill valve will energize and fill
(see Figure 47, 1)
°F symbol flashes
and hold for
IMPORTANT
It is possible that dirt or scale will dislodge in the water line. Always throw away all ice cubes made during the first two to three hours of operation.
.
08/2006 19 www.U-LineService.com
Page 20
CLRCO2175 Combo®— Clear Ice Maker/Refrigerator
A
A
A
Start-Up Troubleshooting
Problem
:
Unit does not appear to turn on when POWER icon is pressed.
Solution
:
Remember that the compressor will not operate until the water has been filling for about 3 minutes. Make sure unit is plugged in and outlet has power (circuit breaker has not tripped). If the unit is equipped with a drain pump, check that the drain line is not obstructed, unit will shut down due to the safety design of the pump if water cannot drain.
Problem
:
Water does not appear to be flowing into unit.
Solution
:
Check that the water is connected and turned on, the line is not obstructed and the overflow tube is inserted securely into water trough.
Problem
:
The unit has been operating for 24 hours and water is still not flowing evenly over evaporator.
Solution
:
Level unit for even water flow. Uneven water flow will reduce ice rate and cause water to spill in ice bin.
IMPORTANT
See the Use and Care Guide’s Troubleshooting Guide for more solutions.
www.U-LineService.com 20 08/2006
Page 21
Who to Call
Service Information
If the need for service arises, call the U-Line Customer Care Center directly @ 800-779-2547. To ensure accurate assistance, please have your Model Number and Serial Number and an explanation of the problem. The Model and Serial Number plate is located inside unit at upper right hand corner.
If you need to locate a service company, you can go online at www.U-LineService.com and search for a service company by zip code.
For more than four decades, U-Line has distinguished itself as the leader in built-in
undercounter ice making, refrigeration and wine storage appliances.
U-Line Corporation, located in Milwaukee, WI, is a family operated manufacturer of built-in
undercounter icemakers, Combo
refrigerators, refrigerated drawers and refrigerator/freezers.
©2006 U-Line Corporation Publication No. 30141E 08/2006 Rev. B
®
icemaker/refrigerators, Wine Captain® wine storage units,
Loading...