U-Line Echelon CLRCO2175B40, Echelon CLRCO2175S40, Echelon CLRCO2175S41, Echelon CLR2160, Echelon CLRCO2175 Use And Care Manual

Use and Care Guide
Clear Ice Maker Model: CLR2160
Clear Combo® Ice Maker/Refrigerator Model: CLRCO2175
CLRCO2175
Introduction
Congratulations on your purchase of a U-Line refrigeration product. A pioneer in the field for more than 40 years, U-Line Corporation is the world’s number one manufacturer of built-in, under-counter, specialty refrigeration and ice making products. U-Line dedicates 100% of its research and development to these products. The result: U-Line technology consistently leads the market with innovation, design, depth of product line and performance.
U-Line products are making life more convenient in homes, businesses, and hotels around the world. U-Line supports its products with a strong dealer network, and its commitment to quality even extends to environmentally safe packaging.
IMPORTANT
READ all of the instructions in this guide completely before operating the unit for the first time.
For future reference, keep this guide in a safe, accessible location. If you need additional information or assistance, please contact U-Line Corporation directly. Contact information appears on the rear cover of this guide.
If you have a problem with the operation of this product, the SERVICE section of this guide will assist you in quickly identifying common problems and provide information on possible causes and remedies. If your product needs service, contact U-Line directly.
Warranty Registration
Your U-Line Corporation Limited Warranty is located on the inside rear cover of this guide. To validate your warranty, the product and its original purchase date must be registered. A Warranty Registration Card has been included for this purpose in the package containing this manual. Complete and mail the Warranty Registration Card, or register your product online at www.U-LineService.com as soon as possible after purchase.
If your product registration is not on file and a request for warranty coverage is received, the date of sale to the U-Line Selling Dealer or Distributor will be established as the first date of warranty coverage for your product.
Please Record Your Model Information
When you request additional information or service, you will be asked for your products model and serial numbers. You can find this information on the serial plate located on the upper right or rear wall in the interior of your unit. This information also appears on the warranty registration card.
Model Number
ULIN_0023_A
Serial Plate
Please record the model number and serial number, date of purchase, and dealer contact information for your U-Line product below:
Model Number:
_____________________________________________________
Serial Number:
_____________________________________________________
Purchase Date:
Dealer Name:
_____________________________________________________
Dealer Address:
_____________________________________________________
Dealer Telephone:
Serial Number
_____________________________________________________
_____________________________________________________
CLR2160, CLRCO2175
TABLE OF CONTENTS
Introduction .................................................................................................. Inside Front Cover
Warranty Registration .................................................................................. Inside Front Cover
Please Record Your Model Information ...................................................... Inside Front Cover
1-Safety Precautions ..................................................................................................................2
Safety Alert Definitions .....................................................................................................2
General Precautions ...........................................................................................................2
2-Product Features ......................................................................................................................3
3-Service ......................................................................................................................................3
Before Calling for Service ..................................................................................................3
If Service is Required ..........................................................................................................3
4-Replacement Parts ..................................................................................................................3
5-Installation ...............................................................................................................................4
Prepare Plumbing ..............................................................................................................4
Water Supply Connection ..................................................................................................4
Drain Connection ................................................................................................................5
Final Water/Drain Connection............................................................................................8
6-Electrical Specifications ..........................................................................................................9
7-Initial Startup ...........................................................................................................................9
8-Operation ..............................................................................................................................10
Turn Unit On/Off ..............................................................................................................10
Temperature Digital Display ...........................................................................................10
Interior Lighting
- Model CLRCO2175 Only ................................................................................................10
9-Normal Operating Sounds.....................................................................................................11
10-Outdoor Usage.....................................................................................................................11
11-Storage, Vacation or Moving .............................................................................................11
12-Product Disposal .................................................................................................................12
13-Maintenance and Cleaning ................................................................................................12
Exterior Cleaning (As Required) ......................................................................................12
Defrosting .........................................................................................................................12
Condenser Cleaning .........................................................................................................13
Clear Ice Maker Cleaning .................................................................................................14
Ice Cube Thickness Adjustment .......................................................................................15
Leveling ............................................................................................................................16
Door Alignment Check and Adjustment ........................................................................17
Door Reversal - Black and White Models Only ...............................................................18
Door Shelf Removal/Insertion .........................................................................................19
Glass Shelf Removal/Installation .....................................................................................19
Light Bulb Replacement - Model CLRCO2175 Only ........................................................19
14-Troubleshooting Guide .......................................................................................................20
15-Electronic Control Quick Guide ..........................................................................................22
Warranty.......................................................................................................... Inside Back Cover
CLR2160, CLRCO2175 1
1
SAFETY PRECAUTIONS
IMPORTANTIMPORTANT
PLEASE READ all instructions completely before attempting to install operate or service your unit.
• Proper installation procedures must be followed if this unit is being initially installed, or is moved to a new location after being in service. An INSTALLATION GUIDE for your unit, providing complete installation information is available from U-Line Corporation directly, and must be consulted before any installation is begun. U-Line contact information appears on the rear cover of this guide.
• This unit requires connection to a grounded (three-prong), polarized receptacle that has been placed by a qualified electrician in accordance with applicable electrical codes.
Safety Alert Definitions
Safety items throughout this guide are labeled with a Danger, Warning or Caution based on the risk type:
DANGER
Danger means that failure to follow this safety statement will result in severe personal injury or death.
WARNING
Warning means that failure to follow this safety statement could result in serious personal injury or death.
CAUTION
Caution means that failure to follow this safety statement may result in minor or moderate personal injury, property or equipment damage.
General Precautions
Use this appliance for its intended purpose only and follow these general precautions along with those listed throughout this guide:
DANGER
RISK OF CHILD ENTRAPMENT. Before you throw away your old refrigerator or freezer, take off the doors and leave shelves in place so that children may not easily climb inside.
WARNING
SHOCK HAZARD - Electrical Grounding Required.
• Never attempt to repair or perform maintenance on the unit until the electricity has been disconnected.
• Never remove the round grounding prong from the plug and never use a two-prong grounding adapter.
• Altering, cutting of power cord, removal of power cord, removal of power plug, or direct wiring can cause serious injury, fire and/or loss of property and/or life and will void the warranty.
• Never use an extension cord to connect power to the unit.
• Always keep your working area dry.
CAUTION
• Use care when moving and handling the unit. Use gloves to prevent personal injury from sharp edges.
• If your model requires defrosting, DO NOT use any type of heater to defrost. Using a heater to speed up defrosting can cause personal injury and damage to the inner lining.
IMPORTANTIMPORTANT
• Do not lift unit by door handle.
• Never install or operate the unit behind closed doors. Be sure front grille is free of obstruction. Obstructing free air flow can cause the unit to malfunction and may void the warranty.
• Failure to clean the condenser every three months can cause the unit to malfunction. This could void the warranty.
• Allow unit temperature to stabilize for 24 hours before use.
• If your model requires defrosting, never use an ice pick or other sharp instrument to help speed up defrosting. These instruments can puncture the inner lining or damage cooling unit.
• Use only genuine U-Line replacement parts. Imitation parts can damage the unit, affect its operation or performance and may void the warranty
2 CLR2160, CLRCO2175
2
PRODUCT FEATURES
CLR2160 Clear Ice Maker
• This model produces up to 60 lbs (27.2 kg) of ice per day, will store 30 lbs (13.6 kg).
• Stainless steel model is deemed suitable for outdoor use by UL.
• An electronic control panel with digital display allows you to control all operating functions.
CLRCO2175 Clear Ice Maker/ Refrigerator
• This model produces up to 40 lbs (18.1 kg) of ice per day, will store 15 lbs (6.8 kg), and provides 2.5 cu ft (71 L) of refrigeration capacity.
• An electronic control panel with digital display allows you to display the interior refrigerator temperature and adjust the setting to your preference.
• Automatic (cycle) defrost eliminates the need for manual defrosting.
• Three fully encapsulated, contoured shelves contain spills and are easy to clean.
• Recessed shelf channels, supporting the encapsulated shelves, provide a sleek, clean appearance to the interior of the cabinet by eliminating protruding shelf supports.
• Two contoured, inner door “pick-off” shelves are adjustable for storage of a variety of different bottle, can, and container sizes and shapes.
• An interior light will illuminate automatically as the cabinet door is opened. However, you can easily select another mode of operation. A blackout/Sabbath mode (not Star K certified) allows you to darken both interior light and the LED display, while maintaining complete temperature control in the unit.
EXCLUSIVE FEATURES OF ÉCHELON
• An easy, self-cleaning process for the clear ice maker eliminates complicated procedures.
• Black and white models feature a slightly contoured, across the top, integrated door handle design that permits the door to be easily reversed. The door comes standard with a factory-installed flush panel. These models can accommodate a 1/4 in. (0.64 cm) thick custom panel to achieve a custom, built-in look by matching surrounding cabinets.
• An optional full overlay door panel kit for black and white units, using a customer provided 3/4" (1.9 cm) thick panel, is available that provides a fully integrated appearance with surrounding cabinets. The overlay panel is easily attached to the door.
• Stainless steel model doors are not field-reversible.
• All stainless steel models have a stainless steel full wrap cabinet, door and sculpted handle that distinguishes
the Echelon™ stainless steel units from other heavier “commercial” looks.
• An optional commercial handle is available through the dealer to further customize your unit.
• Black and white models have vinyl clad steel cabinets that feature a rich textured look, and resist scratching, peeling, or flaking.
• Self-closing door hinges engage when the door is open approximately 8-10 in. (20-25 cm), ensuring a positive door seal and preventing door bounce back.
Features and specifications are subject to change without notice.
3
SERVICE
Before Calling for Service
If your U-Line product appears to be malfunctioning, read through the OPERATION section of this guide to ensure that the function of all controls are clearly understood. If the malfunction persists, the TROUBLESHOOTING GUIDE in this guide will assist you in quickly identifying common problems, and provide information on possible causes and remedies. Most often, this will resolve the problem without the need to call for service.
If Service is Required
If you do not understand a troubleshooting remedy, or your product needs service, contact U-Line Corporation directly at 1-800-779-2547. Additional contact information appears on the rear cover of this guide.
You will be asked for your product Model and Serial Numbers. This information should be recorded inside the front cover of this guide, following the products original purchase. It also appears on the Model and Serial number plate located on the upper right or rear wall of the interior of your product.
4
REPLACEMENT PARTS
When you need replacement parts, always request that genuine U-Line replacements be used. U-Line products have been designed and engineered using components that work efficiently, and provide superior service life and performance. The use of aftermarket parts or components may affect the safety, operation, performance or durability of your product, and may also void its warranty.
CLR2160, CLRCO2175 3
5
INSTALLATION
Prepare Plumbing
CAUTION
Plumbing installation must observe all state and local codes. All water and drain connections MUST BE made by a licensed/qualified plumbing contractor. Failure to follow recommendations and instructions may result in damage and/or harm.
Water Supply Connection
When connecting the water supply, follow these guidelines:
• Review the local plumbing codes before you install the unit.
• Connect to the cold water supply.
• The water pressure should be between 20 and 120 psi.
• The water line MUST have a shut-off valve in the 1/4” O.D. supply line.
• Leave approximately 8’ of water line to be coiled behind the appliance (Figure 1). The water line should be looped into 2 coils. This will allow the unit to be removed for cleaning and servicing. However, make certain that the tubing is not pinched or damaged during installation.
IMPORTANTIMPORTANT
U-Line recommends the use of copper tubing for installation or using flexible water supply kit from U-Line, Part No. WATERHOOKUP.
If using the flexible water supply kit, follow the instructions included with the kit.
To connect to 1/4” copper line water supply:
1. Locate the desired cold water supply location. Attach a
1/4” copper line to this location and route the tubing to the appliance. Leave approximately 8’ of water line to be coiled behind the appliance. The water line should be looped into 2 coils. This will allow the line to flex when removing the unit for cleaning and servicing (Figure 1).
ULIN_S_165
Figure 1
2. Locate the U-Line supplied garden hose fitting. Ensure the end of the copper tubing has been cut straight and free of burrs. Slide the compression nut and ferrule onto the copper tubing as shown (
Figure 2
). Push the assembly completely into the the garden hose fitting and tighten using the two wrenches. Wait to connect this assembly to the appliance until the drain connection is ready.
9/16" Wrench
1/4" Copper Water
Supply Line
7/16" Wrench
From Water Supply
to Ice Maker
ULIN_S_0168_A
4 CLR2160, CLRCO2175
Figure 2
Drain Connection
IMPORTANTIMPORTANT
Drain can NOT be located directly below unit. Unit has a solid base that will not allow unit to drain below itself.
The CLR2160 or CLRCO2175 can be installed using a Gravity Drain, a Factory-Installed Drain Pump (U-Line P60) or a Locally-Installed (U-Line P60) Drain Pump. Drain lines must have a 5/8” inside diameter. The floor drain must be large enough to accommodate drainage from all attached drains.
Note: We strongly recommend the use of the U-Line CLRDRAINKIT for both gravity & pump installations. Depending on your model, your unit may have been packaged with this kit. A complete drain kit containing all the items needed to connect your unit is available from your dealer if your unit was not packaged with this. Order Part No. U-CLRDRAINKIT.
Note: Longer drain connections may require additional drain hose lengths. Additional drain line can be purchased from your dealer or directly from McMaster-Carr. (McMaster-Carr # 52375K35)
Follow these guidelines when installing drain lines to prevent water from flowing back into the ice maker storage bin and/or potentially flowing onto the floor, causing water damage:
Gravity Drain
A Gravity Drain may be used if:
• Drain line has at least a 1-inch drop per 48 inches of run (1/4 inch per foot).
• Drain line does not create traps or created traps are vented (Figure 3).
If using a Gravity Drain:
1. Slide 2 hose clamps onto the drain connection on the rear of the appliance.
2. Insert the barbed fitting halfway into this connection.
3. On the other end of this barbed fitting attach the 5/8” braided tubing.
4. Slide a clamp on each side of the barbed fitting as
(Figure 5).
shown
5. Insulate the drain line, if necessary to prevent condensation. Go on to Final Water/Drain Connection
Page 8.
Gravity Drain
Waste
Shut-Off
Valve
Cold
Water
ULIN_0570_A
Waste
Hot
Water
Figure 4
Drain Fitting from
Back of Unit
Normal
Proper Drain
Poor Drainage, Water Will Back Up
With Trap
With Trap and Vent
Proper Drain
Figure 3
See Figure 4 for a typical Gravity Drain installation.
5/8" x 5/8"
ULIN_0569_A
Barb Connector
Figure 5
Worm Clamps
Drain Line
ULIN_S_0166b2_A
CLR2160, CLRCO2175 5
Factory-Installed Drain Pump
If your drain line will run up to a stand pipe, disposal assembly or spigot assembly or does not otherwise meet the requirements for a Gravity Drain, you may have ordered the CLR2160 or CLRCO2175 with a U-Line P60 Drain Pump. See Figures 8, 9 and 10 for typical installations requiring a Drain Pump. If you need to install a P60 Drain Pump into your unit, see Locally-Installed Drain Pump on Page 6.
4. Check that the clamps and hose connections are tight at the following areas (
Figure 7
):
• Discharge tube (A)
• Drain tube (B)
• Vent tube (C)
CC
BB
IMPORTANTIMPORTANT
Before installing your U-Line CLR2160 or CLRCO2175 with Factory-Installed U-Line P60 Pump, it is extremely important to check and test all hose connections at the drain pump. There is a possibility that hose connections may have loosened during shipment.
To check and test hose connections:
1. Make certain the unit is not plugged into an electrical outlet.
2. Carefully push the power cord grommet through the hole in the back panel (
Screws
Grommet
Power
Cord
Figure 6
, CLRCO2175 shown).
Drain
Fitting
Water
Connection
Back
Panel
ULIN_0574_A
Figure 6
3. Remove 12 screws and back panel.
WARNING
Back panel serves as a guard. DO NOT put your hands inside the ice maker cabinet or attempt to touch any components except the discharge tube during testing. Failure to follow this warning could result in serious personal injury or death.
A
Back View Side View
ULIN_0575_A
Figure 7
5. Place a suitable container beneath the pump’s discharge tube. (The bucket must be able to hold a minimum of one gallon.)
6. Plug the ice maker power cord into a properly grounded, polarized electrical outlet.
7. Place the unit into OFF mode by holding power key for 10 seconds. Not doing this will cause the unit to start the fill cycle which will run for 3 minutes.
8. Verify pump operation by pouring one gallon of water into the ice storage bin of the ice maker. The pump should energize and pump the water into the container.
9. At this time, verify that all tube and clamp connections are tight and leak-free.
10. Unplug unit power cord from electrical outlet.
11. Reinstall back panel.
Locally-Installed Drain Pump
If a gravity drain connection is not possible, and you have not purchased a CLR2160 or CLRCO2175 with factory­installed pump, we strongly recommend the use of the U-Line P60 drain pump. The U-Line P60 drain pump is available through your Dealer, with complete installation instructions. If a pump other than the U-Line P60 drain pump is to be used, it must meet the following specifications:
It must be UL listed and have a UL listed, 120 VAC,
3-wire grounded power cord.
It must have overall maximum outside dimensions of 8-3/4" wide x 5-3/4" deep x 7-3/4" high.
• It must have a minimum flow rate of 1.5 gallons per
minute at 10 feet of lift.
• It must have a sealed sump which does not allow water
leakage in the case of a power outage, restricted drain or pump failure.
6 CLR2160, CLRCO2175
• It must have a check valve in the discharge line to prevent waste water return to the pump.
• It must have an overflow protection control which will shut off power to the ice maker in the event of a pump failure.
• It must have an operating temperature range of 50°F to 110°F (10°C to 40°C).
IMPORTANTIMPORTANT
In the event of a power outage, restricted drain or pump failure, the failure to use the U-Line P60 drain pump or a pump with the above listed specifications, could result in substantial water leakage and pooling with severe and costly water damage and related consequential damages and harm.
Y-Branch Tailpiece P60 Pump Required
Air Gap
(Optional Hook-Up)
Figure 10
Shut-Off
Valve
Hot
Water
ULIN_0573a_A
Waste
Cold
Water
Stand Pipe P60 Pump Required
Disposal Assembly P60 Pump Required
Waste
Figure 8
Air Gap
(Optional Hook-Up)
Shut-Off
Valve
Hot
Water
ULIN_0571a_A
Waste
Cold
Water
WARNING
To prevent accidental electrocution, make certain that the floor surfaces surrounding the unit are dry whenever power is removed from, or applied to, the unit.
Drain Fitting from
Back of Unit
5/8" x 5/8"
Barb Connector
Figure 11
Worm Clamps
Drain Line
ULIN_S_0166b2_A
Figure 9
Waste
To connect to drain:
1. Slide 2 hose clamps onto the drain connection on the
Hot
Water
Shut-Off
ULIN_0572a_A
Cold
Water
Valve
rear of the appliance.
2. Insert the barbed fitting halfway into this connection.
3. On the other end of this barbed fitting attach the 5/8” braided tubing.
4. Slide a clamp on each side of the barbed fitting as
(Figure 11).
shown
5. Insulate the drain line, if necessary to prevent condensation. Go on to Final Water/Drain Connection.
Page 8.
CLR2160, CLRCO2175 7
Loading...
+ 19 hidden pages